• Title/Summary/Keyword: Braking effects

Search Result 89, Processing Time 0.025 seconds

Estimation about Application Effects of Energy Storage System at AC Electric Railway (교류전기철도에서의 에너지저장시스템 적용효과 예측)

  • Lee, Chang-Mu;Lee, Han-Min;Kim, Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1849-1854
    • /
    • 2010
  • Energy Storage System(ESS) is installed at feeding line of railway substation. ESS will absorb regenerative energy when train braking and also charge electric energy when feeding line is no load condition. Absorbed and charged energy will be supplied when train is accelerating condition. Due to ESS the energy variation will be minimized and this effect is estimated.

  • PDF

Finite Element Analysis of Temperature Distribution and Thermally Caused Deformation in Ventilated Disk Brakes

  • Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.150-155
    • /
    • 1995
  • In order to analyze the thermal effects of the rotor models, the finite element technique was used in this study. The length of the hat was investigated as a design parameter. At the start of each brake application the disk surface temperature rapidly increases to a maximum value and then decays due to external cooling and thermal conduction to the hat. The calculated results indicate that the long length of the hat shows the minimum deformation in axial direction, which is related to the thermal problems, coned wear, vibration and noise.

A Fault Detection Method for Solenoid Valves in Urban Railway Braking Systems Using Temperature-Effect-Compensated Electric Signals (도시철도차량 제동장치의 솔레노이드 밸브에 대한 전류기반 고장진단기법 개발)

  • Seo, Boseong;Lee, Guesuk;Jo, Soo-Ho;Oh, Hyunseok;Youn, Byeng D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.835-842
    • /
    • 2016
  • In Korea, urban railway cars are typically maintained using the strategy of predictive maintenance. In an effort to overcome the limitations of the existing strategy, there is increased interest in adopting the condition-based maintenance strategy. In this study, a novel method is proposed to detect faults in the solenoid valves of the braking system in urban railway vehicles. We determined the key component (i.e., solenoid valve) that leads to braking system faults through the analysis of failure modes, effects, and criticality. Then, an equivalent circuit model was developed with the compensation of the temperature effect on solenoid coils. Finally, we presented how to detect faults with the equivalent circuit model and current signal measurements. To demonstrate the performance of the proposed method, we conducted a case study using real solenoid valves taken from urban railway vehicles. In summary, it was shown that the proposed method can be effective to detect faults in solenoid valves. We anticipate the outcome from this study can help secure the safety and reliability of urban railway vehicles.

3D Finite Element Analysis of Skew and Overhang Effects of Permanent Magnet Linear Synchronous Motor (PMLSM의 Skew 와 Overhang 효과에 대한 3D 유한 요소 해석)

  • Lee, Dong-Yeup;Hwang, In-Cheol;Kang, Gyu-Hong;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.10
    • /
    • pp.505-510
    • /
    • 2006
  • This paper deals with skew and overhang effects of permanent magnet linear synchronous motor(PMLSM). The detent force and thrust characteristics considering skew and overhang effects of permanent magnet are analyzed by 3D finite element method and the results are compared to experimental values. As skew and overhang are applied to permanent magnet, the thrust is almost the same value but the detent force is reduced remarkably. By harmonic analysis, the distortion ratio of thrust is remarkably reduced from 4.29[%] to 2.3[%]. and, the ripple ratio of thrust is decreased from 8.2[%] to 3.56[%] at the same time. But, the lateral force which operate as the perpendicular direction of skew direction is generated. The lateral force and normal force acts by braking force between mover and LM-guide.

A Study on Ride Quality Due to Deterioration Effects for the Coupler Types of Urban EMUs (도시철도차량의 연결기 종류별 노후화가 승차감에 미치는 영향 연구)

  • Kim, Jun Woo;Cho, Byung Jin;Han, Eun Kwang;Koo, Jeong Seo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2017
  • In this study, we studied the ride quality considering the deterioration effects of the three type couplers (single, double, and ring types) for EMUs. In order to know the impact occurred when an urban transit vehicle is under breaking, we tested the conditions of the service brake and the emergency brake. Normal coupler models without any slack showed similar dynamic performance results under all breaking conditions. But if the couplers become old, the initial pre-stresses are removed because of permanent compressive deformation in rubber. For three types of the old coupler models without the initial pre-stress, we evaluated dynamic performances of each type. As the results, the maximum and average acceleration levels of the double type and the ring type were similarly low in all conditions. But the accelerations of the single type coupler was high when compared to those of the double and ring types. In addition, Jerk value of the single type model associated with ride quality was high up to 15 times to the ring type in condition of the service braking in empty vehicle weight. Jerk value of the double type model was high up to 6 times to the ring type.

Evaluation of temperature effects on brake wear particles using clustered heatmaps

  • Shin, Jihoon;Yim, Inhyeok;Kwon, Soon-Bark;Park, Sechan;Kim, Min-soo;Cha, YoonKyung
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.680-689
    • /
    • 2019
  • Temperature effects on the generation of brake wear particles from railway vehicles were generated, with a particular focus on the generation of ultrafine particles. A real scale brake dynamometer test was repeated five times under low and high initial temperatures of brake discs, respectively, to obtain generalized results. Size distributions and temporal patterns of wear particles were analyzed through visualization using clustered heatmaps. Our results indicate that high initial temperature conditions promote the generation of ultrafine particles. While particle concentration peaked within the range of fine sized particles under both low and high initial temperature, an additional peak occurred within the range of ultrafine sized particles only under high initial temperature. The timing of peak occurrence also differed between low and high initial temperature conditions. Under low initial temperature fine sized particles were generated intensively at the latter end of braking, whereas under high initial temperature both fine and ultrafine particles were generated more dispersedly along the braking period. The clustered correlation heatmap divided particle sizes into two groups, within which generation timing and concentration of particles were similar. The cut-off point between the two groups was approximately 100 nm, confirming that the governing mechanisms for the generation of fine particles and ultrafine particles are different.

Effects of the Irradiated Current Mode PWM Controller of DC/DC Power Converter (DC/DC 전력 컨버터의 전류모드 PWM 제어기의 방사선 영향)

  • Lho, Young-Hwan;Hwang, Eui-Sung;Lho, Kyeoung-Su;Phouphanonh, Phouphanonh;Khamphoungeun, Khamphoungeun;Han, Chang-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.685-692
    • /
    • 2011
  • DC/DC switching power converters produce DC output voltages from different DC input sources. The converters can be used in regenerative braking of DC motors to return energy back in the supply, resulting in energy savings for the systems containing frequent stops. The current mode DC/DC converter is composed of a PWM (pulse width modulation) controller, a MOSFET, and inductor, etc. Pulse width modulation is applied to control and regulate the total output voltage. It is shown that the variation of threshold voltage at MOSFET and the offset voltage increase caused by radiation effects make the PWM pulse unstable. In the PWM operation, the missing pulses, the changes in pulse width, and a change in the period of the output waveform are studied by simulation program with integrated circuit emphasis (SPICE) and experiments.

  • PDF

Safety Estimation of Engine Lubrication System using Tilting Test Rig (Tilting Test Rig를 이용한 엔진 윤활 시스템 안정성 평가)

  • 윤정의;전문수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.1-6
    • /
    • 2002
  • Engine lubrication system is generally affected by vehicle driving conditions, which are composed of acceleration, braking deceleration and accelerating during cornering. The major reason is due to the oil pan system in which oil is directly influenced by inertia farce caused by vehicle driving conditions. Therefore, to confirm safety of engine lubrication system inertia farce effects are also considered in the developing state. For the purpose, we have carried the engine tilting tests using ourselves made test rig. Verifying the test results we also measured the inertia effects on the engine lubrication system using the circular tuning and slalom test with vehicle. Through the comparison study between two kinds of results we obtained that the engine tilting test rig was very useful to confirm the safety evaluation of engine lubrication system.

Load Flow Calculation and Short Circuit Fault Transients in AC Electrified Railways

  • Hosseini, Seyed Hossein;Shahnia, Farhad
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2203-2206
    • /
    • 2005
  • A load flow and short circuit fault simulation of AC electrified railway distribution systems is presented with DIgSILENT PowerFactory software. Load flow of electrified railways distribution system with concerning multi train lines and dynamic characteristics of train load is studied for different time laps. The dynamic characteristics of train load in starting and braking conditions with different starting and stopping times and its moving positions makes the load flow complicated so there is a great need in studying the effects of electrified railways on load flow. Short circuit fault transients is also studied and simulated for both power system or traction distribution system and their effects on the operation of the train sets is investigated.

  • PDF

Analysis of Dilemma Zone Safety Considering Signal Location (신호기 위치에 따른 딜레마존 안전율 분석)

  • Ryu, Chang-Nam;Kim, Won-Chul;Jang, Tae-Youn;Lim, Sam-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • One of purposes of installing signals at intersections is to protect traffic conflicts and accidents from occurring by means of arranging the right-of-way of travel more clearly. On the other hand, the installation of signals, and especially their location, can also have negative effects on safety. Therefore, the location of signals is of great importance. To secure a high safety level for urban signalized intersection, efforts are required to introduce a comprehensive recommendation or guideline for safety aspects of signal installation that takes local conditions into account. In this context, this reports on a study that analyzed the influence of signal location on the behavior of drivers who approach a signalized intersection in urban area. As a result, the study found out that the traffic signal location strongly affects the braking point of the Dilemma Zone(DZ), and the braking point of the DZ based on driving speed. Also, in terms of design layout, it has been illustrated that there is a close relation between signal location and road safety, especially DZ safety. Finally, this paper proposes a practical recommendation for signal installation related to how to locate the signal in practice for the sake of securing the safety level of signalized intersection.