• 제목/요약/키워드: Bracket-adhesive failure

검색결과 45건 처리시간 0.022초

Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ippolito, Daniela Rita;Gatto, Maria Rosaria;Checchi, Luigi
    • 대한치과교정학회지
    • /
    • 제44권1호
    • /
    • pp.44-49
    • /
    • 2014
  • Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets. Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of $45^{\circ}$ ($45^{\circ}$-angulation group) or $0^{\circ}$ ($0^{\circ}$-angulation group). SBS was tested in a universal testing machine, and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis. Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups. Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.

글라스 아이오노대 시멘트의 인장접착강도 (Tensile Bond Strength of Glass Ionomer Cements)

  • 변승민;권오원
    • 대한치과교정학회지
    • /
    • 제26권3호
    • /
    • pp.317-324
    • /
    • 1996
  • 브라켓 접착제로서 현재까지 널리 사용되어 온 복합레진의 단점들을 보완하기 위해 최근 교정영역에서도 글라스 아이오노머 시멘트의 사용에 관심이 집중되고 있다. 이에 본 연구는 글라스 아이오노머 시멘트를 교정용 브라켓 접착제로 사용시 그 접착강도를 측정해 봄으로써 글라스 아이오노머 시멘트의 임상적 효용성을 알아보기 위하여 시행하였다. 교정치료를 위해 발거한 소구치에 자가중합형 글라스 아이오노머 시멘트인 Shofu Glaslonomer Cement(Shofu Co., U.S.A.)와 GC Fuji I(GC Co., Japan), KETAO CEM(ESPE Co., West Germany)을 분말-액 비율을 달리하여 소구치용 표준형 에지와이즈 브라켓을 접착한 후 15분간 실온에 방치 하였다가 증류수에 침 적 하여 $37^{\circ}C$ 항온조에 보관하였다. 보관한 후 24시간 및 3개월 후에 만능시험기로 인장접착강도를 측정하고 브라켓의 탈락 양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 분말-액 비율을 1로하고 24시간 침적한 경우를 제외하고는 KETAC-CEM이 가장 높은 인장접착강도를 나타내어 (p<0.05) 브라켓 접착시 임상적 유용성이 있으리라 생각되며, Shofu Glaslonomer Cement와 GC Fuji I은 접착강도가 매우 낮았다. 2. 분말-액 비율을 증가시킬때 인장접착강도는 대체로 증가되는 경향을 보였다. 3. 침적시간이 경과할수록 인장접착강도는 대체로 증가되는 경향을 보였다. 4. 브라켓의 탈락 양상은 법랑질과 접착제의 경계부에서 탈락하여 치질에 잔존하는 접착제가 거의 없는 경우가 가장 높은 비율(54.2%)을 차지하였고, 그 다음은 브라켓과 법랑질에 부분적으로 붙어서 탈락한 경우 (36.7%)였으며, 접착제와 브라켓 경계부에서 탈락한 것(9.1%)이 가장 적었다.

  • PDF

광중합 접착제로 접착된 금속 브라켓의 전단접착강도에 관한 연구 (SHEAR BOND STRENGTH OF METAL BRACKETS BONDED WITH LIGHT-CURED ADHESIVE: AN IN VITRO COMPARATIVE STUDY)

  • 장영일;이승진
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.289-296
    • /
    • 1992
  • The purpose of this study was to evaluate and compare the shear bond strengths and failure sites of metal brackets bonded with chemically cured adhesive and light-cured adhesive. 10 brackets were bonded on prepared enamel surfaces with $Transbond^{circledR}$ (Unitek/3M; U.S.A.) light-cured orthodontic adhesive and another 10 brackets were bonded with $Ortho-one^{\circledR}$ (Bisco:U.S.A.) chemically cured orthodontic adhesive. 24 hours after bonding, the Instron universal testing machine was used to measure the shear bond strengths. The failure sites were examined under streoscopic microscope. The results were as follows: 1 . The mean shear bond strength of metal brackets bonded with light-cured adhesive was lower than that of metal brackets bonded with chemically cured adhesive, but the difference was not statistically significant (p < 0.05). 2. Regardless of the type of adhesives, the brackets were failed primarily at the bracket base-adhesive interface. 3. Bonding of metal brackets with light-cured adhesive is considered to be clinically acceptable.

  • PDF

브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교 (The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods)

  • 신재호;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.333-342
    • /
    • 2004
  • 기존의 가시광선 중합기와 비교해서 plasma are light와 LED) 방식의 중합기를 이용해 브라켓을 치아표면에 접착한 후 탈락시키는 실험을 시행해 각각의 중합방식별로 전단결합강도와 접착파절양상을 비교함으로써 임상에서의 유용성을 평가하고자 하였다. 교정치료를 위해 발거한 상, 하악 소구치 60개를 윈통형의 레진블록에 매몰하여 시편을 제작하였다. 광중합형 접착레진인 Transbond XT를 이용하여 광중합 방식별로 조건(가시광선 중합기는 40초, LED방식의 중합기는 20춘, 그리고 plasma arc light 방식의 중합기는 3초)에 따라 브라켓을 접착한 후 만능물성실험기로 전단결합강도를 측정하고 브라켓 기저면을 광학현미경으로 관찰해 접착파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 가시광선 중합방식과 LED 중합방식으로 중합시킨 군간에 전단결합강도의 유의성 있는 차이는 없지만 plasma arc Light방식으로 중합시킨 군은 앞의 두 군에 비해 유의성이 있게 작은 간을 나타내었다(p>0.05). 2. 가시광선 중합방식으로 중합한 군과 LED방식을 이용한 군에서는 파절양상이 거의 유사하게 나타났다. 두 군 모두 잔류접착제가 치아면에만 있는 경우가 제일 적은 비율을 도였으며 브라켓 기저면에 50% 이상의 집착제가 남아 있는 양상이 더 큰 비율을 보였다. 3. Plasma arc light 로 중합시킨 경우에는 접착제가 브라켓 기저면에 50% 이하로 남아있는 양상이 큰 비율로 나타났으며 잔류 접착제 전체가 치아면에 남아 있는 경우는 15%였다. 이상의 실험결과 plasma arc light를 이용한 중합 방식이 가시광선이나 LED 방식을 이용한 중합 방식에 비해 유의성 있게(p>0.05) 낮은 전단결합강도를 보였으나 세 방식 모두 인상적으로 사용하기에 충분한 전단결합강도를 보여 유용하게 사용할 수 있음을 알 수 있었다.

화학적(化學的)으로 재생(再生)된 금속(金屬) bracket의 접착(接着) 강도(强度)와 slot폭경(幅徑) 변화(變化)에 관(關)한 연구(硏究) (A STUDY OF BONDING STRENGTH AND CHANGE OF BRACKET SLOT WIDTH OF CHEMICALLY RECYCLED METAL BRACKETS)

  • 고영삼;이동주
    • 대한치과교정학회지
    • /
    • 제20권2호
    • /
    • pp.283-291
    • /
    • 1990
  • The purpose of this study was to measure and compare tensile and shear strength for 4 types of new direct-bonding brackets and same brackets after recycling and to evaluate the change of bracket slot width after recycling. Four types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile and shear strength was measured by Universal Testing Machine. The brackets were recycled by chemical process and the tensile and shear test was repeated. To evaluate the change of the bracket slot width, slot width was measured by the Topcon Universal Measuring Microscope before and after recycling. Following results were obtained: 1. There was no satistically significant difference between the tensile and shear strength of recycled brackets and those of new brackets. 2. In both new and recycled brackets, the tensile and shear strength of perforated base bracket was lower than those of photoetched, foilmesh and contou-lok mesh base brackets. (P<0.01) 3. There was no statistically significant difference in bonding strengths of control group bonded only once and two times. 4. There was no statistically significant difference in the change of the bracket slow width after recycling process. 5. Of the failure, the combination type (58%) in the tensile strength and the tooth adhesive interface (65%) in the shear strength was the most common type.

  • PDF

치과용 금합금에 대한 금속 프라이머 처리와 열순환 처리가 교정용 브라켓의 전단결합강도에 미치는 영향 (Effect of metal primer and thermocycling on shear bonding strength between the orthodontic bracket and gold alloy)

  • 이영기;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.320-329
    • /
    • 2009
  • 치과용 금합금에 교정용 브라켓 접착 시 금속 프라이머와 열순환 처리가 전단결합강도에 미치는 영향을 알아보기 위하여 80개의 치과용 금합금 시편을 샌드블라스팅만 처리한 군과 3종류의 금속 프라이머(Alloy Primer, Metaltite, V-Primer)처리를 시행한 군으로 분류하고, 이를 열순환 처리 시행 여부에 따라 모두 8개 군으로 분류하였다. 만능물성 시험기를 사용하여 브라켓의 전단결합강도를 측정하고, modified ARI (Adhesive Remnant Index) scores를 통해 브라켓 접착면의 파절 양상을 평가하였다. 열순환 처리 미시행 시에는 금속 프라이머의 적용 시 샌드블라스팅만 단독으로 처리한 경우에 비하여 통계적으로 유의성 있는 전단결합강도의 증가가 있었다 (p < 0.05). 열순환 처리를 시행한 군에는 금속 프라이머의 처리에 의한 전단결합강도의 변화는 유의한 차이가 없었다 (p > 0.05). 금속 프라이머를 적용한 경우 열순환 처리 미시행 시에는 파절 양상이 브라켓과 접착제 계면에서의 파절 발생 빈도가 높았으나, 열순환 처리 시행 시에는 각 군 간 파절 양상에 유의한 차이가 없었다. 이상의 결과로 금속 프라이머의 적용이 치과용 금합금에 대한 교정용 브라켓 접착 시 초기 접착 강도에서는 유의성 있는 결합력의 증가를 보이나, 열순환 처리 시행 후에는 결합 강도에서는 유의한 차이가 없는 것으로 나타나 금속 프라이머에 의한 결합력 증가가 감소하는 것으로 생각한다.

열적, 기계적 피로응력이 교정용 브라켓의 결합강도에 미치는 영향 (Effects of Thermal and Mechanical Fatigue Stress on Bond Strength in Bracket Base Configurations)

  • 김정기;김상철
    • 대한치과교정학회지
    • /
    • 제30권5호
    • /
    • pp.625-642
    • /
    • 2000
  • 본 연구는 열적 및 기계적 피로응력이 교정용 브라켓의 전단결합강도, 인장결합강도, 전단-인장 복합 결합강도에 미치는 영향과 결합상태에 미치는 영향, 그리고 접착파절 양상을 비교하는데 목적이 있다. 이를 위하여 기저부 형태가 다른 5종의 금속 브라켓을 교정치료를 목적으로 발거한 상$\cdot$하악 소구치에 부착하여, 계면에 200g의 전단-인장 복합 하중을 4주간 가한 기계적 피로시험과, 5,000회의 thermocycling을 시행한 열적 피로시험 후, 전단결합강도, 인장결합강도, 및 전단-인장 복합 결합강도를 측정하고, 파절양상을 분석하여 다음과 같은 결과를 얻었다. 1. 정적시험에서 얻은 브라켓 접착부의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았다(p<0.05). 모든 종류의 브라켓에서 전단결합강도가 가장 컸으며, 전단-인장 복합 결합강도는 전단결합강도의 1/3 수준으로 가장 작았다. 2. 4주간 200g의 전단-인장 복합 하중을 가한 후의 결합강도는 Photoetched base가 가장 크고, Integral base가 가장 작았으며 (p<0.05), 기계적 피로시험 후 Photoetched base와 Micro-Etched Foil Mesh base의 전단, 인장, 전단-인장 복합 결합강도가 감소하였고, Chessboard base의 전단결합강도가 감소하였다(p<0.05). 3. 5,000회의 thermocycling 후의 결합강도는 Photoetched base가 가장 컸고, integral base가 가장 작았으며(p<0.05), 열적 피로시험 후 Photoetched base와 Chessboard base, Micro-Etched Foil Mesh base의 결합강도가 모두 감소하였다(p<0.05). 4. 정적시험의 결합강도 측정 후 접착파절은 브라켓/레진 계면에서 일어났으며, thermocycling 후에는 브라켓/레진 계면과, 법랑질/레진 계면, 레진내 파절이 혼합되어 나타나 ARI 점수가 높아졌다. 기계적 피로시험 후에는 정적시험 때와 비슷한 ARI 점수를 보였다. 5. 모든 브라켓에서 thermocycling 후 브라켓/레진 계면과 법랑질/레진 계면에서 미세 균열이 관찰되었다.

  • PDF

브라켓 간접부착술식시 레진베이스의 표면처리가 전단결합강도에 미치는 영향 (The Effect of Resin Base Surface Treatment on Shear Bond Strength in Indirect Bracket Bonding Technique)

  • 임병철;황현식
    • 대한치과교정학회지
    • /
    • 제28권5호
    • /
    • pp.681-688
    • /
    • 1998
  • 본 연구는 브라켓 간접부착술식시 레진 베이스의 표면처리에 따른 전단결합강도와 파절양상을 비교함으로써 레진 베이스 표면처리의 효과를 평가해 보기 위하여 시행되었다. 소의 하악 중절치를 포매하여 만든 90개 시편의 석고 모형에 광중합형 레진 접착제를 이용하여 금속 브라켓을 위치시킨 후 대조군은 표면처리하지 않은 반면 실험군은 레진 베이스를 Plastic Conditioner와 sandblasting으로 각각 표면 처리하여 시편에 옮겨 부착한 다음 만능물성 시험기를 이용하여 전단결합강도를 측정하고,파절양상을 관찰하여 다음과 같은 결과를 얻었다. 1. 레진 베이스를 표면처리하지 않은 경우에 비하여 Plastic Conditioner와 sandblasting으로 각각 처리한 경우 평균 전단결합강도가 높게 나타났으며 통계적으로 유의한 차이를 보였다. 2. Plastic Conditioner로 처리한 군과 sandblasting으로 처리한 군 간의 전단결합강도는 통계적 유의차를 보이지 않았다. 3. 각 군의 파절양상을 접착제 잔류지수를 통하여 비교 관찰한 결과 세 군 간에 통계적 유의차를 보이지 않았다. 4. 전단결합강도와 접착제 잔류지수 간의 상관검정 결과 전단결합강도가 높은 경우 레진 베이스와 브라켓 경계부에서의 파절이 빈번한 경향을 보였으나 그 통계적 유의성은 보이지 않았다. 이상의 실험결과는 브라켓 간접부착술식에서 결합강도 증가를 위하여 레진 베이스의 표면처리가 필요함을 시사하였다.

  • PDF

치과용 금합금의 표면처리에 따른 교정용 브라켓의 전단결합강도 변화 (Change of shear bond strength of orthodontic brackets according to surface treatment on dental gold alloy)

  • 민지현;황현식;김종철
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.483-490
    • /
    • 2000
  • 치과용 금합금에 브라켓을 부착하는 경우 자연치에 비하여 낮은 결합강도를 보이며, 잦은 브라켓 탈락이 나타나고 있는 바, 본 연구는 여러 가지 금합금 표면처리 방법이 교정용 레진 접착제와 금합금 간의 전단결합강도에 미치는 영향을 평가하여 금합금과 브라켓 간의 부착강도 증진방법을 모색하고자 시행하였다. 치과용 금합금으로 주조된 240개의 시편을 표면처리 유무 및 방법에 따라 무처리, 샌드블라스팅 단독처리, 샌드블라스팅과 주석도금 병용처리, 그리고 샌드블라스팅과 중간접착제 병용처리의 4가지 경우와, Ortho-one, Panavia 21, Superbond C&B의 3가지 레진접착제의 조합에 의해 12군으로 나누어 브라켓을 부착하였다. 시편을 증류수에 담아 $37^{\circ}C$ 항온 수조 속에서 24시간 동안 보관한 후, 만능물성 시험기를 이용하여 전단결합강도를 측정한 후 다음과 같은 결과를 얻었다. 1. 치과용 금합금의 표면을 처리하지 않은 경우에 비하여 표면처리한 군에서 통계적으로 유의하게 높은 전단결합강도가 나타났다. 2. 샌드블라스팅 단독처리에 비하여 주석도금 병용처리를 시행한 경우 Panavia 21에서만 유의한 결합강도 증가가 나타났다. 3. 샌드블라스팅 단독처리에 비하여 중간접착제 병용처리를 시행한 경우 모든 접착제에서 유의한 결합강도 증가가 나타났다. 4. 사용된 레진접착제에 따른 전단결합강도를 비교한 결과 Superbond C&B가 가장 높고 그 다음으로 Panavia 21, Ortho-one 순으로 나타나는 양상을 보였다. 이상의 결과는 금합금 표면에서 브라켓 부착강도를 증가시키기 위해서는 레진접착제 종류에 관계없이 샌드블라스팅과 중간접착제 병용처리가 필요함을 시사하였다.

  • PDF

치과용 니켈-크롬합금에 대한 표면 처리가 인장접착강도에 미치는 영향 (THE EFFECTS OF SURFACE TREATMENT OF DENIAL NICKEL-CHROMIUM ALLOY ON TENSILE BOND STRENGTH)

  • 이은숙;권오원
    • 대한치과교정학회지
    • /
    • 제27권3호
    • /
    • pp.493-502
    • /
    • 1997
  • 본 연구에서는 치과용 니켈-크롬합금의 표면에 전처리없이 치과용 브라켓을 Super-bond로 접착한 대조군과 샌드블라스팅 및 tin-plating을 각각 혹은 병용으로 표면처리후 Super-bond로 접착한 실험각군의 인장접착강도, 브라켓 탈락양상 및 주사전자현미경 소견을 비교하여 임상적용 가능성을 알아보고자 하였으며 다음과 같은 결과를 얻었다. 1. 인장장접착강도는 니켈-크롬합금의 표면에 샌드블라스팅 처리후 Super-bond로 브라켓을 접착한 실험 I군이 $14.41{\pm}2.24MPa$로 가장 높았고, tin-plating처리후 Super-bond로 접착한 실험 III군이 $13.59{\pm}1.51MPa$, 샌드블라스팅후 tin-lating처리를 하고 Super-bond로 접착한 실험 II군이 $12.27{\pm}1.45MPa$, 특정한 표면처리 없이 Super-bond로 접착한 대조군이 $10.50{\pm}1.57MPa$로 가장 낮게 나타났으나 실험 I군과 실험 III군간, 실험 III군과 실험 II군간, 실험 II군과 대조군간에는 유의한 차이가 없었다(p>0.05). 2. 브라켓의 주된 탈락양상은 대조군의 경우 $70\%$가 브라켓과 접착제 계면에서 adhesive failure를, $30\%$가 니켈-크롬합금과 접착제 계면에서 adhesive failure를 나타내었고, 실험 각군은 모두 브라켓과 접착제 계면에서 adhesivefailure 를 나타내었다. 3. 주사전자현미경 소견에서 대조군의 경우 일부 레진이 브라켓 기저면에 부착되어 나타났으나 실험 각군에서는 거의 대부분의 레진이 니켈-크롬합금면에 부착되어 관찰되었고, 샌드블라스팅만 시행한 시편면이 가장 균일하고 조밀한 표면 요철상을 나타내었다.

  • PDF