• Title/Summary/Keyword: Bracket

Search Result 785, Processing Time 0.02 seconds

A Study on the Derivation of Bracket Structure Terminology in Yingzaofashi in the Era of Song Dynasty (송대(宋代) ${\ll}$영조법식(營造法式)${\gg}$ 대목작(大木作) 포작(鋪作) 관련용어의 파생에 관한 연구)

  • Kim, Jae-Ung
    • Journal of architectural history
    • /
    • v.20 no.2
    • /
    • pp.55-70
    • /
    • 2011
  • This paper aimed at analyzing of structural carpentry terminology for bracket structure in Yingzaofashi ${\ll}$營造法式${\gg}$in the era of Song Dynasty and illuminating coinage characteristics and method of Structural Carpentry Terminology for bracket Structure through graphonomy research and system and structure of these terms. The results are as follow. The structural carpentry terminologies for structure were identified to be approximately 23 words, and terminology of bracket structure鋪作 is largely categorized into 3 categories of Type鋪作次序, Structure, Place. On the other hand, the structural carpentry terminologies for parts largely categorized into 2 categories of Bracket structure鋪作, Others. Bracket structure terminologies for parts were derived from the core of Dou枓, Gong栱, Ang昂, Fang方. The phenomena of derivation in structural carpentry terminology for bracket structure can be explained by the difference in the shape of subsidiary material and the location for usage of the subsidiary material and part of the subsidiary material and their functions.

EFFECTS OF THE DIFFERENT CERAMIC BRACKET BASES ON SHEAR BOND STRENGTH (도재브라켓 접착면의 처리방식이 전단결합강도에 미치는 영향)

  • Kim, Jin-Oh;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.957-967
    • /
    • 1994
  • The purpose of this study was to evaluate the effects of different bases of ceramic brackets on shear bond strength and to observe failure patterns of bracket bondings. Lower bicuspid brackets whose bases designed for the macromechanical and silane treated chemical bonding those for silane treated chemical bonding, those for micromechanical bonding, and those for macromechanical bonding were tested as experimental groups, and foil mesh-backed metal brackets as a control group. All the brackets were bonded with $Mono-Lok\;2^{(TM)}$ on the labial surface of extracted human lower bicuspids after etching the enamel with $38\%$ phosphoric acid solution for 60 seconds. The shear bond strengths were measured on the universal test machine after 24 hours passed in the $37^{\circ}C$ water bath. The gathered data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. The shear bond strengths of brackets for macromechanical and chemical bonding, those for chemical bonding, and those for micromechanical bonding were not different (p>0.05), but showed statistically higher than those of metal bracket and those of ceramic bracket for micromechanical bonding(p<0.05). The shear bond strengths of ceramic bracket for micromechanical bonding showed statistically lower than those of metal bracket(p<0.05). The enamel fractures and/or ceramic bracket fractures were observed in the cases of higher bond strength than that of metal bracket. These results supported that silane treated base of ceramic bracket show higher shear bond strength than that of metal bracket, and suggested that micromechanical form of ceramic bracket bases show higher shear bond strength than that of macromechanical form.

  • PDF

Shear bond strength and adhesive failure pattern in bracket bonding with plasma arc light (Plasma arc light를 이용한 bracket 부착시의 전단결합강도와 파절양상의 유형)

  • Yoo, Hyung-Seok;Oh, Young-Geun;Lee, Seung-Yeon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.261-270
    • /
    • 2001
  • The purpose of this study was to evaluate the clinical usefulness of plasma arc light which can reduce the curing time dramatically compared by shear bond strengths and failure patterns of the brackets bonded with visible light in direct bracket bonding. Some kinds of brackets were bonded with the Transbond$^{\circledR}$ to the human premolars which were embedded in the resin blocks according to the various conditions. After bonding, the shear bond strength was tested by Instron universal testing machine and in addition , the amount of residual adhesive remaining on the tooth after debonding was measured by the stereoscope and assessed with adhesive remnant index(ARI). The results were as follows : 1. When plasma arc light was used for bonding the brackets, the shear bond strength was clinically sufficient in both metal and ceramic brackets, but resin brackets showed significantly lower bond strength but which was clinically useful. 2. When metal brackets were bonded using visible light, there was no significant difference in shear bond strength due to the light-curing time and the bond strength was clinically sufficient. 3. When the adhesive failure patterns of brackets bonded with plasma arc light were observed by using the adhesive remnant index, the bond failure of the metal and resin bracket occurred more frequently at bracket-adhesive interface but the failure of the ceramic bracket occurred more frequently at enamel-adhesive interface. 4. There was no statistically significant difference of the shear bond strength and adhesive failure pattern between metal bracket bonded for 2 seconds by curing with plasma arc light and 10 seconds by curing with visible light. 6. When metal brackets were bonded using plasma arc light, the shear bond strength decreased as the distance from the light source increased. The above results suggest that plasma arc light can be clinically useful for bonding the brackets without fear of the decrease of the shear bond strength.

  • PDF

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF

Fracture strength of tie wings in a newly-developed polycarbonate bracket (국산 폴리카보네이트 브라켓 윙의 파절 강도에 관한 연구)

  • Sun, Min-Kyu;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.204-211
    • /
    • 2007
  • Objective: With an increasing demand for esthetic orthodontic appliances, the interest in polycarbonate brackets has also increased. However, polycarbonate bracket wings are prone to fracture. The purpose of this study was to evaluate the clinical usefulness of a newly-developed polycarbonate bracket by measuring the fracture strength of bracket tie wings. Methods: Alice (K.M. Daicom, Seoul, Korea) and Spirit MB (Ormco, Glendora, CA, USA) brackets were used as an experimental and control bracket respectively. Each bracket group was divided into halves. One half was untreated and the other half was treated with 2,000 times of thermocycling between $5^{\circ}C\;and\;55^{\circ}C$. The fracture strength of the wing was measured by a universal testing machine. Results: Alice bracket wings showed significantly higher strength than Spirit MB bracket wings in both untreated and thermocycled bracket cases. Conclusion: Alice brackets may be used clinically in terms of the strength of bracket wings.

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

  • Son, Young-Tak;Son, KeunBaDa;Kim, Kyung-Min;Lee, Jae-Mok;Kim, Jin-Wook;Yu, Wonjae;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different irradiation energy levels and times. Materials and Methods: For the measurement of the temperature of the adhesive resin, it was applied at the base of the ceramic bracket, a thermocouple was placed at the center of the base surface, the bracket was placed on prepared resin specimens for light curing, and a laser was irradiated to the center of the bracket slot at 5, 7, and 10 W. For the measurement of the temperatures of the enamel under the bracket and pulp cavity, extracted premolar was fixed to a prepared mold and the ceramic bracket was bonded to the buccal surface of the premolar. The Kruskal-Wallis H test and Friedman test were used for statistical analysis. Result: At 5 W, the temperature of the adhesive resin did not reach the resin softening temperature of 200℃ within 30 seconds. At 7 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 28 seconds. At 10 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 15 seconds. During laser irradiation, the temperature of the enamel under the bracket increased by over 5℃ within 15 seconds. Conclusion: The use of diode laser irradiation for bracket debonding should be carefully considered because the pulp cavity temperature increases by over 5℃ within the irradiation time for resin thermal softening.

A STUDY ON THE CHEMICAL RECYCLING METHOD OF METAL BRACKET (금속(金屬) Bracket의 화학적(化學的) 재생처리(再生處理) 방법(方法)에 관(關)한 연구(硏究))

  • Bang, Sang-Yong;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.20 no.1
    • /
    • pp.103-110
    • /
    • 1990
  • Metal brackets were recycled by variable methods for economic reason. Such recycling methods had a great effect on bracket slot width and bonding strength. Therefore, the recycling methods that don't change the properties of original bracket were suggested. In this study, debonded brackets were recycled with 30 kinds of solvents and bracket surfaces were examined by S.E.M. (Super IIIA, ISI International Scientific Instruments, Japan) and Stero Microscope (Sz-Tr, Olympus Tokyo, Japan) methods. The following results were obtained. 1. Thermosetting resin adhesives (eq. $Monolok^{(R)}$, $Concise^{(R)}$) were swelled most in sulfuric acid (assays 95%) and slightly in alcohol groups. 2. The solvent was exchanged every 24 hours during the brackets were recycled with sulfuric acid (assays 95%). As the passage of time, the adhesives were removed more clearly, and after 72 hours adhesives were nearly detached from bracket base. 3. Chemical recycled metal bracket surface showed no irregular structure by S.E.M. method.

  • PDF

A Study on Development of End Bracket for External Prestress Method (외부프리스트레스트 보강 공법에 사용되는 단부 브라켓의 개발 연구)

  • 한만엽;이재형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.721-726
    • /
    • 1999
  • Diverse strengthening methods for reinforced concrete are applied to real structures with a variety of materials. On the other hand, only external prestressing is used for strengthening damaged prestressed concrete girders. But the end brackets for external prestressing are hard to design and to manufacture, the magnitude of prestressing is limited when applied to real structures. The current end brackets are not clearly understood in load transmitting mechanisms and they may damage the original girder by drilling during construction. And also the designed welding area of the current bracket is insufficient to support the high load. The problems of current end bracket are solved in this study. And a new and improved end bracket is proposed and tested. The tested end bracket is similar to the end bearing bracket, but many supportting plates are addded to increase its welding length of the weakest point of the bracket. The increased welding length finally increases its load carrying capacity significantly.

  • PDF

A prediction of maximum operation speed for the catenary using tunnel bracket (터널 브래킷을 사용한 가선시스템의 최고속도 예측 및 검토)

  • ;;;M'hamed Matri
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.628-635
    • /
    • 2000
  • The catenary system supported by the tunnel bracket which has been used uniquely in KNR was selected as the catenary inside narrow existing tunnel in the electrification of Kyeung-Bu Line for operation of Korea High Speed Train(KTX). It was demanded to judge the maximal operable speed of KTX in this catenary system to implement the planning. To do this, the tunnel bracket was firstly tested to obtain the characteristic data. The stiffness of this bracket are computed depending on the location which catenary installed on. Moreover, the catenary using tunnel bracket is modelled numerically respecting the bracket stiffness. Based on these, the dynamics between this catenary and KTX pantograph are simulated with the program developed by ourselves independently. The simulation result are evaluated according to the generally acceptable criteria. Consequently, the maximal operable speed of KTX in the catenary using KNR(Korean National Railroad) tunnel bracket is predicted and some items which are needed to be kept in the processing of implementation are drawn.

  • PDF

THE COMPARISON OF SHEAR STRENGTH AND BRACKET PLACEMENT BETWEEN BONDING TECHNIQUES (접착술식에 따른 전단강도 및 Bracket위치의 비교)

  • Pak, Yun-Kyong;Kook, Yoon-A;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.513-520
    • /
    • 1991
  • The purpose of this study was to compare the bracket placement and the shear bond strength of indirect-bonded brackets with those of direct-bonded ones. Forty eight extracted human teeth were collected and attached with brackets and tested on shear bond strength, using Instron. Fourteen patients from Wonkwang University Dental Hospital were selected for direct bonding of brackets and their teeth were measured on bracket angulation and bracket height. The obtained results were as follows: 1. The shear bond strengths of incisors were higher in direct-bonding,group, rather than in-direct-bonding group. But, the shear bond strength of premolars showed no significant differences between groups. 2. The bracket angulations of indirect-bonding group were preciser than those of direct-bonding group, especially in upper first premolars, lower lateral incisors, canines, premolars. 3. In bracket height, there were no significant differences between groups.

  • PDF