• Title/Summary/Keyword: Br

Search Result 2,135, Processing Time 0.027 seconds

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Studies on the MC1R Gene Frequencies in Landrace, Large White, Duroc and Jeju Native Black Pigs (랜드레이스, 대요크셔, 듀록 및 제주 흑돈의 Melanocortin 1 Receptor(MC1R) 유전자의 유전자형 분석)

  • Cho, I.C.;Lee, J.G.;Jung, J.G.;Yang, B.S.;Kang, S.Y.;Kim, B.W.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.207-212
    • /
    • 2002
  • This study was conducted to investigate the genotypes and frequencies of Melanocortin 1 Receptor(MC1R) genes in pigs which plays a central role in regulation of eumelanin (black/brown) and phaeomelanin(red/yellow) pigment synthesis within the mammalian melanocytes. Four different breeds of pigs(20 Landrace, 20 Yorkshire, 20 Duroc, and 93 Jeju native black pigs) were used and PCR-RFLP analysis of MC1R gene was also carried out. Two regions of MC1R genes (428bp and 405bp) were amplified using two specific primers (MERL1-EPIG2, EPIG1-EPIG3), respectively and MC1R allele were determined using 2 restriction enzymes (BspHⅠ, AccⅡ). The results of this experiment indicated that MC1R allelic type in Landrace, Large Yorkshire and Duroc were MC1R *2 (Ep), MC1R *2 (Ep), MC1R *4 (e), respectively. However, various allelic types of MC1R genes were detected in Jeju native black pigs. MC1R allelic type of Jeju black pigs was MC1R*2 type as in Meishan and Large black breeds or MC1R*3 type as in Hampshire and Berkshire breeds and the gene frequencies of ED1 and ED2 were 0.554 and 0.446 in average.

Current status of Brassica A genome analysis (Brassica A genome의 최근 연구 동향)

  • Choi, Su-Ryun;Kwon, Soo-Jin
    • Journal of Plant Biotechnology
    • /
    • v.39 no.1
    • /
    • pp.33-48
    • /
    • 2012
  • As a scientific curiosity to understand the structure and the function of crops and experimental efforts to apply it to plant breeding, genetic maps have been constructed in various crops. Especially, in the case of Brassica crop, genetic mapping has been accelerated since genetic information of model plant $Arabidopsis$ was available. As a result, the whole $B.$ $rapa$ genome (A genome) sequencing has recently been done. The genome sequences offer opportunities to develop molecular markers for genetic analysis in $Brassica$ crops. RFLP markers are widely used as the basis for genetic map construction, but detection system is inefficiency. The technical efficiency and analysis speed of the PCR-based markers become more preferable for many form of $Brassica$ genome study. The massive sequence informative markers such as SSR, SNP and InDels are also available to increase the density of markers for high-resolution genetic analysis. The high density maps are invaluable resources for QTLs analysis, marker assisted selection (MAS), map-based cloning and comparative analysis within $Brassica$ as well as related crop species. Additionally, the advents of new technology, next-generation technique, have served as a momentum for molecular breeding. Here we summarize genetic and genomic resources and suggest their applications for the molecular breeding in $Brassica$ crop.

Study on the Biosynthetic Characteristics of Photosynthetic Pigments in Dodder(Cuscuta australis R. Br.) Plant (실새삼의 광합성색소 생합성특성에 관한 연구)

  • Kim, J.S.;Kwak, H.H.;Kim, B.C.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.17 no.3
    • /
    • pp.314-324
    • /
    • 1997
  • This study was conducted to investigate whether 1) photosynthetic pigments(chlorophylls and carotenoids) are formed in dodder plant(Cuscuta australis), 2) there are any characteristics in the pigment biosynthesis, compared to that of other normal plants, and 3) dodder responds to some herbicides having target site on chloroplast. 1. Chlorophyll content of dodder tendrill grown under a natural daylight was 9 times and 50 times lower than that of field bindweed stem and leaf, respectively. 2. The photosynthetic pigment contents varied in different tissues, being higher in a apical region than in a lower region of seedling or tendrill. Chlorophyll wasn't almost observed below the 4th internode from the upper. 3. Pigment contents were greatly dependent on light intensity so that there were 4 to 6 times difference among light conditions. When the shoot containning low pigment contents under natural light, was incubated in growth chamber with various light intensities, the pigment contents were increased by 3 times of initial contents at about 97${\mu}E$ $m^{-2}s^{-1}$PAR. While the change in pigment contents was not observed at above 450${\mu}E$ $m^{-2}s^{-1}$PAR 4. Exogenous supply of 5mM 5-aminolevulinic acid increased protochlorophyllide by 7 times and 1.4 times in the etiolated shoot from field bindweed rhizome and in dodder stem, respectively, showing that dodder relatively has a low response to 5-aminolevulinic acid. 5. Pigment loss was observed in the treatment of paraquat, norflurazon, oxyfluorfen and diuron, and protoporphyrin IX was accumulated by oxyfluorfen as in normal plants Based on above results, several chracteristics of pigment biosynthesis in dodder seem to be summerized as follows. Photosynthetic pigment biosynthesis in Cuscuta australis runs even in low level. The pigment contents is differentially distributed in different regions and their contents seem significantly to be controlled by light intensities. Especially, chloroplast rapidly tends to degenerate with the development of tissue. Some herbicides having target site on chloroplast induce damage to dodder stem but are unlikely to control it well in field, except paraquat, due to low chloroplast activity and parasitic mode of nutrition.

  • PDF

A Study of Coloration of Topaz(I): Mineralogical and Chemical Study on the Topaz Selected from Some Localities of the World (토파즈의 人工着色 處理를 위한 硏究(I) : 世界 主要 産地別 토파즈의 鑛物學的 및 化學的 特性)

  • Han, Yi-Kyeong;Park, Maeng-Eon;Jang, Yong-Nam
    • Journal of the Mineralogical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.109-121
    • /
    • 1992
  • For the purpose of mineralogical and chemical study on the topazes from various localities of world(Brzail, China, India, Nigeria and Sri Lanka), electron microprobe analysis(EPMA), neutron activation analysis(NAA), X-ray diffractometry, Raman spectroscopy, etch test, scanning electron microscopy, refractive index, specific gravity, fluid inclusion were performed. The chemical composition in topaz was discussed along with its physical and structural properties. Variations in the unit-cell dimension and physical properties of topaz were found to have a close relations in the unit-cell dimension and physical properties of topaz were found to have a close relationship with extent of substitution of $OH^-\;for\;F^-$. According to neutron activation analyses, the trace elements had no effects on the physical properties of topaz. Raman spectra showed that the peaks of topaz were different in intensity from one locality to another. Etching defects in topaz includes negative crystal defect o point-bottom pit(India, Nigeria) and net work defect of curl-bottom pit(Brazil, China). Fluid inclusions in topaz may be classiffied into liquid $CO_2$-bearing inclusion, gaseous inclusion, halite, sylvite-bearing inclusion and liquid inclusion. The results of this study can be useful to devising artificial coloring methods for topaz with different mineralogical compositions.

  • PDF

A Study on the Post-Receptor Mechanism of Adenosine Receptor on Acetylcholine Release in the Rat Hippocampus (흰쥐 해마에서 Acetylcholine 유리에 관여하는 Adenosine Receptor의 Post-Receptor 기전에 관한 연구)

  • Choi, Bong-Kyu;Oh, Jae-Hee
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.3
    • /
    • pp.263-272
    • /
    • 1994
  • Since it was been reported that the depolarization-induced ACh release is inhibited by activation of presynaptic $A_1-adenosine$ heteroreceptor in hippocampus, a large body of experimental data on the post-receptor mechanism of this process has been accumulated. But, the post-receptor mechanism of presynaptic $A_1-adenosine$ receptor on the ACh release has not been clearly elucidated yet. Therefore, it was attempted to clarify the post-receptor mechanisms of the $A_1-adenosine$ receptor-mediated control of ACh release in this study. Slices from rat hippocampus were equilibrated with $^3H-choline$ and the release of the labelled products was evoked by electrical stimulation (3 Hz, 5 $VCm^{-1}$, 2ms, rectangular pulses), and the influence of various agents on the evoked tritium-outflow was investigated. Adenosine, in concentrations ranging from $0.3{\sim}300\;{\mu}M$, decreased the ACh release in a dose-dependent manner, without affecting the basal rate of release. The adenosine effects were significantly inhibited by $DPCPX\;(2\;{\mu}M)$, a selective $A_1-receptor$ antagonist. The responses to N-ethylmaleimide $(10&30{\mu}M)$, a SH-alkylating agent of G-protein, were characterized by increments of the evoked ACh-release and the basal release, and the adenosine effects were completely abolished by NEM pretreatment. PDB $(1{\sim}10\;{\mu}M)$, a specific protein kinase C (PKC) activator, increased, whereas PMB $(0.03{\sim}1\;mg)$, a PKC inhibitor, decreased the evoked ACh-release, and the adenosine effects were not affected by these agents. Nifedipine $(1\;{\mu}M)$, a $Ca^{2+}\;-channel$ blocker of dihydropyridine analogue, significantly inhibited the adenosine effect, but glibenclamide, a $K^+-channel$ blocker, did not. Finally, 8-bromo cyclic AMP $(100\;&\;300{\mu}M)$, a membrane-permeable analogue of cAMP, did not alter the ACh release, but adenosine effects were inhibited by pretreatment with large dose of 8-br-cAMP $(300\;{\mu}M)$. These results indicate that the decrement of the evoked ACh-release by $A_1-adenosine$ receptor is mediated by the G-protein, and nifedipine-sensitive $Ca^{2+}-channel$ and adenylate cyclase system are coupled partly to this effect, and that protein kinase C and glibenclamide-sensitive $K{^+}-channel$ are not involved in this process.

  • PDF

Chemical Reactions in Surfactant Solutions (Ⅳ) : Micellar Rate Effect on Reactions of Hydroxide and o-Iodosobenzoate Ions with Organic Phosphinates (계면활성제 용액속에서의 화학반응 (제 4 보) : $OH^-$ 및 o-Iodosobenzoate 이온에 의한 유기 포스피네이트의 탈인산화 반응에 미치는 CTAX 미셀의 영향)

  • Hong, Yeong Seok;Kim, Hyeon Muk
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.753-762
    • /
    • 1994
  • Dephosphorylation of diphenyl- or isopropylphenyl-4-nitrophenylphosphinate (DPNPIN or IPNPIN) mediated by $OH^-$ or o-iodosobenzoate ion ($IB^-$) are relatively slow in aqueous solution. The reactions in CTAX micellar solutions are, however, very accelerated, because CTAX micelles can accommodate both reactants in their Stern layer in which they can easily react, while hydrophilic $OH^-$(or $IB^-$) and hydrophobic phosphinates are not mixed in water. Even though the concentrations (> $10^{-3}$ M) of $OH^-$(or $IB^-$) in CTAX solutions are much larger amounts than those ($6{\times}10^{-6}$ M) of phosphinates, the rate constants of the dephosphorylations are largely influenced by change of the concentration of the ions, which means that the reactions are not followed by the pseudo first order kinetics. In comparison to effect of the counter ions of CTAX in the reactions, CTACl is more effective on the dephosphorylation of DPNPIN (or IPNPIN) than CTABr due to easier expelling of $Cl^-$ ion by $OH^-$(or $IB^-$) ion from the micelle, because of easier solvation $Cl^-$ ion by water molecules. The reactivity of IPNPIN with $OH^-$(or $IB^-$) is lower than that of DPNPIN. The reason seems that the 'bulky' isopropyl group of IPNPIN hinders the attack of the nucleophiles. The mechanism of reaction of IPNPIN with IB- ion concluded as 'nucleophilic' instead of 'general basic' by a trapping experiment and a measured kinetic isotope effect.

  • PDF

Rapid Extraction of DNA using Ion Exchange Resin for Early Detection of Mycobacterium tuberculosis by the Polymerase Chain Reaction (결핵균 PCR에서 이온교환수지를 이용한 신속한 DNA 분리)

  • Kim, Cheol-Min;Park, Seung-Kyu;Shon, Mal-Hyun;Song, Sun-Dae;Kim, Young;Jun, Eun-Sook;Son, Han-Chul;Jung, Byung-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.30-37
    • /
    • 1996
  • Background: The extraction methods of DNA from clinical samples are the major obstacle to use the PCR(polymerase Chain Reaction) in routine labortary for early detection of M. tuberculosis. We tried to improve the extraction method of DNA from sputum for establishment of the PCR in routine labortary by reducing the possibility of cross contamination and performing it easily and safely. Methods: We used the $InstaGene^{TM}$ DNA extraction kit(BioRad Co.) using Chelex 100 ion exchange resin for preparation of DNA. We compared InstaGene method in 100 cases of sputum from proteinase K method which is known as the most commonly used method for DNA purification(Experiment 1). And we compared InstaGene method in 98 cases of sputum from Microwave method developed by a company in Korea(Experiment 2). In experiment 1,245bps of IS6110 were amplified and then 188bps were amplified by nested PCR. In experiment 2,536bps in primary PCR and 276bps in nested PCR were amplified and analysed by agarose gel electrophoresis and EtBr staining. Results: When we chose AFB smear, culture, or AFB smear and culture as a standard test, PCR had low specificity and positive predictive value in both experiments. The InstaGene method has higher value in sensitivity and negative predictive value significantly than proteinase K method. The InstaGene method and the Microwave methods were similar in sensitivity, specificity, positive predictive value and negative predictive value. Conclusion: Even though both methods had lower possibility of cross contamination, shorter time requirement, simplicity, and economic advantages than Proteinase K method, the InstaGene method was a little simpler than the Microwave method. Therefore, in terms of usefulness in clinical application, the Instagene method seems to be the most useful method in DNA extraction for detection of M. tuberculosis using PCR. The reliability of this method will be clarified by further studies with enough clinical samples.

  • PDF

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture