• 제목/요약/키워드: Bone screws

검색결과 184건 처리시간 0.029초

Absorbable Plate-Related Infection after Facial Bone Fracture Reduction

  • Choi, Seung Hyup;Lee, Jang Hyun
    • 대한두개안면성형외과학회지
    • /
    • 제17권1호
    • /
    • pp.1-4
    • /
    • 2016
  • Absorbable plates are used widely for fixation of facial bone fractures. Compared to conventional titanium plating systems, absorbable plates have many favorable traits. They are not palpable after plate absorption, which obviates the need for plate removal. Absorbable plate-related infections are relatively uncommon at less than 5% of patients undergoing fixation of facial bone fractures. The plates are made from a mixture of poly-L-lactic acid and poly-DL-lactic acid or poly-DL-lactic acid and polyglycolic acid, and the ratio of these biodegradable polymers is used to control the longevity of the plates. Degradation rate of absorbable plate is closely related to the chance of infection. Low degradation is associated with increased accumulation of plate debris, which in turn can increase the chance of infection. Predisposing factors for absorbable plate-related infection include the presence of maxillary sinusitis, plate proximity to incision site, and use of tobacco and significant amount of alcohol. Using short screws in fixating maxillary fracture accompanied maxillary sinusitis will increase the rate of infection. Avoiding fixating plates near the incision site will also minimize infection. Close observation until complete absorption of the plate is crucial, especially those who are smokers or heavy alcoholics. The management of plate infection is varied depending on the clinical situation. Severe infections require plate removal. Wound culture and radiologic exam are essential in treatment planning.

체외 고정구용 골 삽입 금속 나사 개발 (The Development of Pin Screws into the Bone for External Fixator)

  • 최영철;이근민;나운환;송병섭
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.5-17
    • /
    • 2009
  • 골에 삽입한 후 체외고정구에 결합하여 조절함으로써 골절회복(장골의 개방성골절, 연부조직의 재건술 및 관절고정술 등)에 사용되는 금속나사를 특별히 고안한 절삭도구와 연삭기구 및 독자적인 후처리 공정을 통하여 국내기술로 처음 개발, 상품화하였다. 개발된 제품과 수입제품의 비교실험을 실시한 결과, 수입제품대비 평균 103%의 특성을 나타내었다. 이 제품의 개발에 적용된 설계기법 및 후처리 공정과 요소실험 결과들을 소개한다.

  • PDF

심한 경추부 외상후에 전방 경추부 수술후 발생한 식도의 누공 (Esophageal Fistula Related to Anterior Cervical Spine Surgery after Severe Cervical Trauma)

  • 팽성화
    • Journal of Trauma and Injury
    • /
    • 제25권4호
    • /
    • pp.278-282
    • /
    • 2012
  • An esophageal perforation following anterior cervical fusion is rare. Early development of an esophageal perforation after anterior cervical fusion is usually due to iatrogenic injury from retraction, injury associated with the original traumatic incident, improperly placed instruments or a bone graft. A 31-year-old man had a cervical dislocation and spinal cord injury because of severe cervical trauma after a traffic accident. He was quadriplegic and had no feeling below T4 dermatome. Anterior decompression of the cervical spine and anterior fusion with mesh with autobone were performed. An esophagocutaneous fistula occurred 7 days after anterior cervical surgery. A second anterior surgery was done because of pus drainage. The mesh was changed with an iliac bone graft, and the esophagocutaneous fistula site was primary repaired, but pus continued to drain. Conservative treatment, which consisted of wound drainage and intravenous administration of antibiotics, was tried, but was unsuccessful. After all, we removed the plate and screws, but did not removed the iliac bone graft, We closed the esophageal fistula, and transposed the sternocleidomastoid muscle flap to the interspace between the esophagus and the cervical spine. The wound to the esophagus was well repaired. In conclusion, precautionary measures are needed to avoid the complication, and adequate treatment is necessary to resolve those complications when they occur.

Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study

  • Mirac Berke Topcu, Ersoz;Emre, Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권6호
    • /
    • pp.346-359
    • /
    • 2022
  • PURPOSE. Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS. In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS. The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION. For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.

Effects of crown retrieval on implants and the surrounding bone: a finite element analysis

  • Ozkir, Serhat Emre;Unal, Server Mutluay;Yurekli, Emel;Guven, Sedat
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.131-136
    • /
    • 2016
  • PURPOSE. The aim of this study was to observe stress concentration in the implant, the surrounding bone, and other components under the pull-out force during the crown removal. MATERIALS AND METHODS. Two 3-dimensional models of implant-supported conventional metal ceramic crowns were digitally constructed. One model was designed as a vertically placed implant ($3.7mm{\times}10mm$) with a straight abutment, and the other model was designed as a 30-degree inclined implant ($3.7mm{\times}10mm$) with an angled abutment. A pull-out force of 40 N was applied to the crown. The stress values were calculated within the dental implant, the abutment, the abutment screw, and the surrounding bone. RESULTS. The highest stress concentration was observed at the coronal portion of the straight implant (9.29 MPa). The stress concentrations at the cortical bone were lower than at the implants, and maximum stress concentration in bone structure was 1.73 MPa. At the abutment screws, the stress concentration levels were similiar (3.09 MPa and 3.44 MPa), but the localizations were different. The stress at the angled abutment was higher than the stress at the straight abutment. CONCLUSION. The pull-out force, applied during a crown removal, did not show an evident effect in bone structure. The higher stress concentrations were mostly observed at the implant and the abutment collar. In addition, the abutment screw, which is the weakest part of an implant system, also showed stress concentrations. Implant angulation affected the stress concentration levels and localizations. CLINICAL IMPLICATIONS. These results will help clinicians understand the mechanical behavior of cement-retained implant-supported crowns during crown retrieval.

가토 하악골에서 신연 골형성술시 Osteonectin의 발현 (EXPRESSION OF OSTEONECTIN ON DISTRACTION OSTEOGENESIS IN THE RABBIT MANDIBLE)

  • 김동준;지유진;송현철
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권5호
    • /
    • pp.391-399
    • /
    • 2004
  • Distraction osteogenesis has been thought to be promising technique for replacing bone graft in maxilla and mandible. The purpose of this study was to investigate the expression of osteonectin on distraction osteogenesis. Sixteen rabbits were used for this experiment. Osteotomy was performed between premolar and mental foramen. On the experimental group, distraction device was connected to the respective bone segments. On the control group, bone segments were fixed using plate and screws after osteotomy. Distraction was carried out at the rate of 0.7mm per day to obtain a 4.9mm elongation on the experimental group. After 3 days, 7 days, 14 days, and 28 days two rabbits of each group were sacrificed. The results obtained from this study were as follow : Experimental group was observed that the gaps between the distracted bone edges were occupied by new bone. Expression of Osteonectin were detected throughout the experiment in both groups and Expression of Osteonectin were markedly increased during distraction and consolidation period in experimental group than control group. From these results, it could be stated that distraction was shown to improve and accelerate bone formation and mechanical stress like distraction has considerable effects on osteonectin.

인조골에 체결된 유리섬유/폴리프로필렌 복합재료 고정판의 수분 환경 피로 특성 (Fatigue Characterization of Glass/Polypropylene Composite Bone Plates Locked with an Artificial Tibia under Moisture Environment)

  • 한민구;장승환
    • Composites Research
    • /
    • 제26권5호
    • /
    • pp.328-333
    • /
    • 2013
  • 본 연구에서는 유리섬유/폴리프로필렌 복합재료 고정판을 인조골에 체결하여 실제 골절치료 시술 상황을 모사하였으며, 고정판의 적합성을 판단하기 위하여 수분 흡수율, 스크류의 체결 상태, 하중 조건의 변화에 따른 피로 실험을 진행하였다. 실험 결과 0~12주 동안 수분 흡수가 이루어진 모든 시편에서 기대 수명인 65만 사이클을 넘는 100만 사이클 이상의 피로 수명을 가짐을 확인하였다. 스크류 체결 상태는 골절부의 변형률 차이에 주목할만한 영향을 미치지 못하였다. 본 논문에서는 유리섬유/폴리프로필렌 복합재료 고정판을 다양한 환경조건 하에서 압축-압축 피로실험을 수행하여 기계적 우수성을 입증하였으며, 이 결과는 향후 금속 고정판을 복합재료 고정판으로 대체하기 위한 관련 연구에 유용한 정보를 제공할 것으로 기대된다.

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min;Lee, Jong Hun
    • 대한두개안면성형외과학회지
    • /
    • 제20권5호
    • /
    • pp.297-303
    • /
    • 2019
  • Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.

하악지시상분할골절단술 시행 후 von-Miese 항복강도에 대한 유한요소법적 연구 (A STUDY OF VON-MISES YIELD STRENGTH AFTER MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY)

  • 윤옥병;김여갑
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권3호
    • /
    • pp.196-204
    • /
    • 2002
  • For the study of its stability when the screw has been fixed after sagittal split ramus osteotomy(SSRO) of the mandible, the methods of screw arrangement are classified into two types, triangular and straight. The angles of screws to the bone surface are classified as perpendicular arrangements, the $60^{\circ}$ anterioinferior screw, known as triangular, and the most posterior screw, called straight arrangement, thus there are four types. The finite element method model has been made by using a three dimensional calculator and a supercomputer. The load directions are to the anterior teeth, premolar region, and molar region, and the bite force is 1 Kgf to each region. The distribution of stress, the von-Mises yield strength, and safety of margin refer to the total sum of transformed energy have been studied by comparison with each other. The following conclusion has been researched : 1. When shear stress is compared, in the triangular arrangement in the form of "ㄱ", the anterosuperior screw is seen at contributing to the support of the bone fragment. In the straight arrangement, substantial stress is seen to be concentrated on the most posterior angled screw. 2. When the von-Mises yield strength is compared, it seemed that the stress concentration on the angled anteroinferior screw is higher, it shows a higher possibility of fracture than any other screw. In the straight arrangement, stress appeared to be concentrated on the most posteriorly angled screw. 3. When the safety margins of the transfomed energy are compared, the energy conduction is much greater in the case of the angled screw than in the case of the perpendicular screw. The triangular arrangement in the form of "ㄱ" shows a superior clinical sign to that of the straight arrangement. Judging from the above results, when the screw fixation is made after SSRO in practical clinical cases, two screws should be inserted in the superior border of mandibular ramus and a third screw of mandibular inferior border should be inserted in the form of triangular. All screws on the bony surface should be placed perpendicularly-$90^{\circ}$ angles apparently best promote bony support and stability.

단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석 (THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS)

  • 권주홍;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.