• 제목/요약/키워드: Bone Quantity

검색결과 138건 처리시간 0.025초

Effect of Measured Energy Restriction and Age Intervals on Growth, Nutrient Digestibility, Carcass Parameters, Bone Characteristics and Stress in Broiler Breeders during the Rearing Period

  • Sunder, G. Shyam;Kumar, Ch. Vijaya;Panda, A.K.;Gopinath, N.C.S.;Raju, M.V.L.N.;Rao, S.V. Rama;Reddy, M.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권7호
    • /
    • pp.1038-1047
    • /
    • 2008
  • This study aimed at targeting fixed increases in body weight (100 g/wk) by quantitatively regulating energy allowances (ME) in broiler breeders from 5 to 20 wks of age. Four energy regimes were tested: 1. The energy required for maintenance, activity and growth was calculated for 100 g increases in body weight/wk and a measured quantity of grower diet (160 g protein and 2,600 kcal ME/kg) was offered to the control group (ME-100) to achieve the anticipated weight gain. The energy allowances increased with age from 132 to 294 kcal/d. 2. Additionally, three energy regimes were considered, quantitatively reducing ME by 10% (ME-90) or 20% (ME-80) and increasing by10% (ME-110) over the control group. Each test group had 23 replicates5 female chicks housed in cages. The influence of energy regimes and age on growth, nutrient digestibility, carcass attributes, bone parameters and stress was evaluated at 4 wk intervals. Quantitative ME restriction by 10% (119-265 kcal/d) produced an average weight gain of 98.1 g/wk, which was closer to the targeted increase of 100 g/wk, whereas the control group attained it nine days earlier. Restriction of energy by 10 or 20% produced better conversion efficiency of feed, energy and protein and apparent digestibility of protein, Ca and P than 10% excess ME. Energy regimes did not influence eviscerated meat yield, but higher energy allowances (ME-110) significantly increased abdominal fat pad and liver weights and decreased giblet weight, percent muscle protein and tibia ash. Relatively higher stress was recorded in ME-restricted groups, as reflected by wider heterophil and lymphocyte ratios and increased bursa weight. Early age (5-12 wk) significantly influenced bone mineralization, conversion efficiency of feed, energy and protein and apparent digestibility of protein, Ca and P, while later ages (13-20 wk) increased eviscerated meat yield, abdominal fat, tibia weight and muscle protein and reduced stress. Energy regime x age interactions were significant and are discussed. In conclusion, the synthetic broiler line used in our study responded positively to controlled energy feeding during the rearing period. Breeders offered 119-265 kcal/d, a reduction of 10% energy over the control group, were more effective in regulating grower performance than the latter. In addition to energy regimes, age intervals also exhibited significant influence on specific parameters during the grower phase.

Protective effects of remifentanil against H2O2-induced oxidative stress in human osteoblasts

  • Yoon, Ji-Young;Kim, Do-Wan;Kim, Eun-Jung;Park, Bong-Soo;Yoon, Ji-Uk;Kim, Hyung-Joon;Park, Jeong-Hoon
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권4호
    • /
    • pp.263-271
    • /
    • 2016
  • Background: Bone injury is common in many clinical situations, such as surgery or trauma. During surgery, excessive reactive oxygen species (ROS) production decreases the quality and quantity of osteoblasts. Remifentanil decreases ROS production, reducing oxidative stress and the inflammatory response. We investigated remifentanil's protective effects against $H_2O_2$-induced oxidative stress in osteoblasts. Methods: To investigate the effect of remifentanil on human fetal osteoblast (hFOB) cells, the cells were incubated with 1 ng/ml of remifentanil for 2 h before exposure to $H_2O_2$. For induction of oxidative stress, hFOB cells were then treated with $200{\mu}M$ $H_2O_2$ for 2 h. To evaluate the effect on autophagy, a separate group of cells were incubated with 1 mM 3-methyladenine (3-MA) before treatment with remifentanil and $H_2O_2$. Cell viability and apoptotic cell death were determined via MTT assay and Hoechst staining, respectively. Mineralized matrix formation was visualized using alizarin red S staining. Western blot analysis was used to determine the expression levels of bone-related genes. Results: Cell viability and mineralized matrix formation increased on remifentanil pretreatment before exposure to $H_2O_2$-induced oxidative stress. As determined via western blot analysis, remifentanil pretreatment increased the expression of bone-related genes (Col I, BMP-2, osterix, and $TGF-{\beta}$). However, pretreatment with 3-MA before exposure to remifentanil and $H_2O_2$ inhibited remifentanil's protective effects on hFOB cells during oxidative stress. Conclusions: We showed that remifentanil prevents oxidative damage in hFOB cells via a mechanism that may be highly related to autophagy. Further clinical studies are required to investigate its potential as a therapeutic agent.

녹용으로부터 Insulin-like Growth Factor-I의 일부정제 및 정량 (Partial Purification and Quantification of Insulin-like Growth Factor-I from Red Deer Antler)

  • ;모은경;;;;성창근
    • 생명과학회지
    • /
    • 제17권10호
    • /
    • pp.1321-1329
    • /
    • 2007
  • 사슴뿔은 동물세계에서 가장 빨리 성장하는 조직이다. 따라서 성장중인 사슴뿔은 뼈 성장을 촉진하는 인자가 풍부하게 포함된 것으로 생각된다. 이들 성장인자들 중 IGF-1은 뼈를 자라게 하는 조골세포의 대사에 중요한 역할을 한다고 알려져 있어 이를 정제하고자 하였다. IGF-1의 정제는 상대라고 불리는 신선한 사슴뿔을 유안침전, DEAE-Sepharose CL-6B 이온교환수지, CM-Sepharose CL-6B 양이온교환수지, Sephadex G-50의 순차적인 방법으로 할 수 있었다. 각 과정마다 IGF-1의 거동을 HPLC, SDS-PAGE, Dot blot, 그리고 western blot으로 분석하였다. IGF-1의 정량은 ELISA기술로 재조합 인간 IGF-1을 이용하여 계산되었으며, 최종 분별 액은 두 개의 단백질을 보였으나, Western-blot에서 작은 분자량인 12 kDa으로 최종 판명할 수 있었다. 정제된 단백질은 HPLC에서 retention 시간 8분만에 검출되었으며, 총 농도는 2910 ng/ml 이고 중량은 0.291 g 이었다.

Wide open lateral cephalogram을 이용한 하악골 성장에 관한 연구 (STUDY ON THE GROWTH OF THE MANDIBLE USING WIDE OPEN LATERAL CEPHALOGRAM)

  • 문성욱;박영국;정규림
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.39-50
    • /
    • 2001
  • 교정치료를 함에 있어 하악골의 모양, 성장률, 성장방향에 대한 예측은 치료계획의 수립 및 치료기간과 예후를 결정하는데 있어 중요한 역할을 한다. 이를 규명하기 위해 다양한 방법들이 시도 되어왔고 측모두부방사선규격사진을 이용함으로써 좀 더 정확성을 기할 수 있게 되었다. 그러나 해부학적인 구조의 특성상 하악과두 부위에서 중첩이 발생하여 정확한 형태 및 위치의 측정에 의문이 남는다. 이 연구의 목적은 하악과두 부위에서 중첩을 피하여 좀 더 정확한 하악골의 형태 및 성장양상을 알아보고자 함에 있다. 이 연구는 1급 부정교합군 14명, 2급 부정교합군 9명, 3급 부정교합군 17명, 총 40명의 환자를 대상으로 평균 4년 3개월의 기간을 두고 최대개구상태의 측모두부방사선규격사진(Wide Open lateral cephalogram)을 촬영하여 11개의 계측항목을 설정, 계측하였고 Autocad Rl4 program을 이용하여 평균적인 외형을 작도하고 측면적을 계측하여 비교, 분석하였다. 그 결과 다음의 결론을 얻었다. 1 하악체의 길이(gonion-menton)는 3급, 1급, 2급 순으로 증가추세를 보였고 3급 부정교합군이 2급 부정교합군에 비해 2배 이상 증가하였으나 통계학적으로는 3급 부정교합군과 1급 부정교합군, 2급 부정교합군과 1급 부정교합군 사이에는 유의성이 있었고 3급 부정교합군과 2급 부정교합군 사이에는 유의한 상관성이 없는 것으로 나타났다(p<0.05). 2. Go-Me, A-Cd, B-Cp, E-F, G-H, 측면적의 항목에서 연 평균 성장량, 성장속도 들에서 3급 부정교합군에서 많은 증가를 보이고 특히 2급 부정교합군에 비해서는 명확한 차이를 보이고 있다. 3. 평균 4년 3개월 동안의 하악골 측면적의 연 평균 성장량은 1급 부정교합군이 $1.0cm^2$, 2급 부정교합군이 $0.8cm^2$, 3급 부정교합군이 $1.4cm^2$이고 성장율은 $11.9\%,\;11.8\%,\;20.3\%$로 1급 부정 교합군과 2급 부정교합군에서는 별 차이가 보이지 않았고 3급 부정교합군에서는 다른 두 군에 비해 2배에 가까운 성장율을 보였다. 이상의 결과에서 부정교합의 유형에 따른 하악골의 성장량의 차는 선천적인 악골의 크기에 의해서 라기 보다는 성장 중 발생하는 하악골의 성장속도와 성장량의 차이에 의한 것으로 사료된다.

  • PDF

Requirement of Non-phytate Phosphorus in Synthetic Broiler Breeder Diet

  • Bhanja, S.K.;Reddy, V.R.;Panda, A.K.;Rama Rao, S.V.;Sharma, R.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권6호
    • /
    • pp.933-938
    • /
    • 2007
  • An experiment was conducted to study the laying performance, shell quality, bone mineralization, hatchability of eggs and performance of progeny (weight at day one and 14 d of age, P content in day old chick, leg score and survivability of chicks) of synthetic broiler breeders fed different levels of non-phytate phosphorus (NPP). Six levels of NPP (1.2, 1.8, 2.4, 3.0, 3.6 and 4.2 g/kg diet) at a constant calcium (Ca) level (30 g/kg) in a maize-soya-deoiled rice bran based diet were tested. Levels of dicalcium phosphate, shell grit and deoiled rice bran were adjusted to achieve the desired levels of NPP and Ca. Each level of NPP was fed with a weighed quantity of feed (160 g/b/d) to 40 female broiler breeders from 25 to 40 weeks of age housed in individual cages. Each bird was considered as a replicate. Egg production, feed/egg mass, body weight, egg weight, shell weight, shell thickness, egg specific gravity, serum Ca content and tibia breaking strength were not influenced (p>0.05) by the variation in dietary NPP levels tested. Increasing the dietary levels of NPP did not influence the hatchability of eggs, phosphorus (P) contents both in egg yolk and day old chick, chick body weight at day one and 14 d of age, leg score and survivability of chicks up to 14 d of age. Maximum response ($p{\leq}0.01$) in shell breaking strength, tibia ash and serum inorganic P contents were observed at NPP levels of 2.09, 2.25 and 3.50 g per kg diet, respectively. The retention of Ca increased, while the P retention decreased ($p{\leq}0.01$) with increasing dietary levels of NPP. Though maximum responses in shell breaking strength, bone ash and serum inorganic P were observed at NPP higher than 1.2 g/kg diet, the broiler breeder performance in terms of egg production, shell quality, hatchability of eggs and progeny performance and their survivability was not influenced by dietary NPP concentrations. It is concluded that synthetic broiler breeders maintained in cages do not require more than 1.2 g NPP/kg diet with a daily intake of 192 mg NPP/b/d during 24 to 40 weeks of age.

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

발치 직후 시행된 즉시 임플란트 식립술에 관한 임상적 평가 (Clinical Evaluation about the Immediate Implant Replacement after Tooth Extraction)

  • 양은영;천상득;노재환;이승은;송재철;진병로
    • Journal of Yeungnam Medical Science
    • /
    • 제20권1호
    • /
    • pp.45-52
    • /
    • 2003
  • Background: Immediate implant placement has become an acceptable treatment for the edentulous area. The advantages of the immediate implant placement include considerable decrease in time from tooth extraction to placement of the finial prosthesis, fewer surgical procedures, and better acceptance of the overall treatment plans. But the success is dependent on the quantity and quality of the extraction socket. The purpose of this study is to evaluate the success of the immediate implant placement. Materials and Methods: Twenty-one sites in 16 patients were selected for the evaluation of the immediate implant placement. All of the cases were followed using clinical and radiographic examinations. Criteria of success were the absence of peri-implant radiolucency, mobility, and persistent pain or sign of infection. Results: Of the 21 implants, 13 implants have been succeeded. Of the 13 implants, 10 implants were replaced for the periodontal disease and 3 implants were replaced for the trauma. Conclusion: The criteria of the success in immediate implant placement are as follows. 1) Implants placed into fresh extraction sockets have a high rate of survival. 2) Implant should be placed as close as possible to the alveolar crest. 3) Implant placed into available bone beyond the apex have a high success rate.

  • PDF

상악 완전 무치악 환자에서 6개의 임플란트를 동반한 두가지 가철성 의치 치료의 8년 경과 관찰 증례 (Eight-year follow-up of two different removable prostheses using six implants in maxillary edentulous patients)

  • 양승원;김종은;김지환
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.300-304
    • /
    • 2017
  • 자연치열에 대합하는 완전 무치악 환자의 수복에서 임플란트를 이용한 고정성 보철물 또는 임플란트 피개의치는 좋은 치료법이다. 그러나, 완전 고정성 보철을 통한 치료는 충분한 골질, 골량이 뒷받침되어야 하기에 그 한계가 있다. 한편, 최근에는 임플란트 고정성 보철물과 함께 그것을 가철성 국소의치의 지대치로 사용하는 치료가 행해지고 있다. 본 증례보고는 자연치열에 대합되는 두 상악 완전 무치악 환자에 있어 임플란트 피개의치와 임플란트 고정성 보철물 및 가철성 국소의치를 이용한 치료 및 8년 경과관찰, 유지보수를 비교 고찰해 보고자 한다.

Survival of 352 titanium implants placed in 181 patients: a 4-year multicenter field study

  • Shin, Seung-Il;Yun, Jeong-Ho;Kim, Sung-Geun;Park, Byoungkyou;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • 제44권1호
    • /
    • pp.8-12
    • /
    • 2014
  • Purpose: The aim of this retrospective chart review was to evaluate the four-year survival rate of a titanium implant system. Methods: A total of 352 sand-blasted, thermally acid-etched titanium implants were inserted into 181 partially or completely edentulous patients. Their cumulative survival rate was evaluated retrospectively. Associated factors, such as the implant distribution and treatment type were included in the evaluation. Results: The implants were equally distributed between the maxilla (52.3%) and the mandible (47.7%). 48 implants (13.6%) were placed in the anterior region and 304 implants (86.4%) in the posterior region. The majority of the implants were inserted into bone of type II and III quality (89.8%) and volume (quantity B and C, 87.2%). Most of the implants (70.7%) were restored as single crowns; 28.7% supported a bridge construction and 0.6% a full denture. Only one implant failed, resulting in a four-year cumulative survival rate of 99.7%. Conclusions: The implant system showed an excellent four-year survival rate. It proved to be a safe and predictable means for restoration of the dentition in partially or completely edentulous patients.

Hip Protector Design Process for the Korean Elderly

  • Jeon, Eun-Jin;Kim, Hee-Eun
    • 한국의류산업학회지
    • /
    • 제18권4호
    • /
    • pp.520-530
    • /
    • 2016
  • This research aims to propose an ergonomic design process for hip protector based on previous studies, existing products, multidisciplinary experts opinion, and wearing test. The elderly are more likely to suffer a hip fracture when they fall due to their physical changes in skeletal form, muscle quantity, bone density, and joint movement. A hip protector is an effective product to prevent hip fractures in the elderly but it also has a problem in that it is uncomfortable. Therefore there is a high chance that it won't be able to prevent hip fractures properly. Since the comfort of a hip protector is one of the most critical elements in preventing a hip fracture, we need to keep improving the hip protector for mobility and usability. Based on the previous studies and limitations of current hip protector products, we need to come up with an optimal design for the Korean elderly. First, knowledge has to be built relating to the ergonomic design of the hip protector considering body shape and size analysis using 3D-scan data, and biomechanical analysis on hip fracture. Second, we need to develop a design process including hip protector pattern design, and wearing evaluation with virtual system. Third, we suggest to reevaluate and verify the design procedure from impact evaluation using testing simulator, virtual evaluation of impact, to wearing comfort and usability evaluation. This design process presented in this study would be expected to contribute to the development of ergonomic hip protector which is suitable for the Korean elderly.