• Title/Summary/Keyword: Bone Quality

Search Result 704, Processing Time 0.028 seconds

Histomorphometric Study of Implants Initially Stabilized through Bone Graft Packing into the Osteotomy before Implant Placement in Case of Wide Defects

  • Lee, Wang-Jae;Hong, Ki-Seok
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: This study sought to evaluate the effects of bone graft wedging on the initial stability of implants in bone sites of unfavorable quality. Materials and Methods: Three male beagle dogs were used in this study. Osteotomies were performed with parallel drills (${\O}4.1{\times}10mm$), and fixtures (${\O}3.3{\times}8mm$) were placed. The control group was given implants without bone graft. Experiment group A was given implants with minimal initial stability using autobone grafts, whereas experiment group B was given xenografts. Groups were also divided by healing times at 4, 8, and 12 weeks. Results: All implants in the control group failed to osseointegrate. On the other hand, all implants in the experiment groups were clinically well-maintained during the entire experiment period. After 4, 8, and 12 weeks, bone-to-implant contact (BIC) ratio and implant stability quotient (ISQ) increased in the experiment groups. The differences between experiment groups A and B were not statistically significant, however. Conclusion: In unfavorable bone regions for dental implants, bone graft packing into the osteotomy prior to implant placement secured minimal initial stability and showed reasonable BIC ratios and ISQ values throughout the study period.

Estimation of Lower Jaw Density using CT data

  • Jargalsaikhan, Ariunbold;Sengee, Nyamlkhagva;Telue, Berekjan;Ochirkhvv, Sambuu
    • Journal of Multimedia Information System
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Bone density is one of the factors in the early failure of dental implants and doctors should make a preoperative assessment of jaw bone density using patient's CT data before dental implant surgery in order to find out whether the patient has osteoporosis and osteopenia. The main goal of this study was to propose a method that based on image processing techniques in order to provide accurate information about where to drill and place an abutment screw of implants in the jaw bone for doctors and reduce human activity for the estimation of the local cancellous bone density of mandible using CT data. The experiment was performed on a computed tomography data of the jaw bone of two different individuals. We assumed that the result of the estimation of jaw bone density depends on the angle of drilling and average HU (Hounsfield Unit) values were used to evaluate the quality of local cancellous bone density of mandible. As a result of this study, we have been developed a toolbox that can be used to estimate jaw bone density automatically and found a positive correlation between the angle of the drill and time complexity but a negative correlation between the diameter of the drill and time complexity.

Analgesic Effect of Intrathecal Ginsenosides in a Murine Bone Cancer Pain

  • Yoon, Myung-Ha;Kim, Woong-Mo;Lee, Hyung-Gon;Choi, Jeong-Il;Kim, Yeo-Ok;Song, Ji-A
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.230-235
    • /
    • 2010
  • Background: Bone cancer pain has a disruptive effect on the cancer patient's quality of life. Although ginsenosides have been used as traditional medicine in Eastern Medicine, the effect on bone cancer pain has not been throughly studied. The aim of this study was to determine whether ginsenosides may alter the bone cancer pain at the spinal level. Methods: NCTC 2472 tumor cells ($2.5{\times}10^5$) were injected into the femur of adult male C3H/HeJ mice to evoke bone tumor and bone cancer pain. To develop bone tumor, radiologic pictures were obtained. To assess pain, the withdrawal thereshold was measured by applying a von Frey filament to the tumor cells inoculation site. The effect of intrathecal ginsenosides was investigated. Effect of ginsenosides (150, 500, $1,000{\mu}g$) was examined at 15, 30, 60, 90, 120 min after intrathecal delivery. Results: The intrafemoral injection of NCTC 2472 tumor cells induced a radiological bone tumor. The withdrawal threshold with tumor development was significantly decreased compared to the sham animals. Intrathecal ginsenosides effectively increased the withdrawal threshold in the bone cancer site. Conclusions: NCTC 2472 tumor cells injection into the mice femur caused bone tumor and bone cancer pain. Intrathecal ginsenosides attenuated the bone cancer-related pain behavior. Therefore, spinal ginsenosides may be an alternative analgesic for treating bone cancer pain.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.

Ankle Arthrodesis with Vascularized Fibular Graft in Failed Ankle Fusion (혈관 부착 비골 이식술을 이용한 실패한 족관절 고정술의 치료)

  • Chung, Duke Whan;Chung, Chai Ik;Lim, Young Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.9 no.2
    • /
    • pp.134-138
    • /
    • 2000
  • Arthrodesis of the ankle joint is inevitable in the cases of severe arthrosis or defective bony structures around ankle joint. There have been many kinds of arthrodesis methods were introduced. In cases with failed athrodesis with previous arthrodesis surgery and neuropathic joints have difficulty to achieve fusion of joint with conventional methods. Authors underwent four cases of ankle fusion with vascularized fibular graft from 1997 in the cases of three failed fusions and one diabetic neuropatic joint. Two of four performed free vascularized fibular transplantation from contralateral side leg with microvascular anastomosis, two of four performed with pedicled fibular transposition to the ankle joint in same side leg. Three of four cases achieved arthrodesis average 9.2 months after surgery, one case was failed due to vascular thrombosis of the anastomosed site in diabetic neuropathic condition. The result of this technique revealed 75%(three of four) success rate and longer bone union time required. However, in these cases had no recommendable options with conventional bone graft and additional ankle joint fusions procedure because of poor bone quality and defect of distal tibia and talus portions. Free vascualrized fibular transfer to the failed athrodesis of ankle joint is one of the effective alternative methods in failed ankle fusion cases, especially the quality of the bone around previous fusion site is poor.

  • PDF

Genetic determinants of periosteum-mediated craniofacial bone regeneration: a systematic review

  • Eyituoyo Okoturo
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.6
    • /
    • pp.251-259
    • /
    • 2023
  • Background: Periosteum-mediated bone regeneration (PMBR) is a recognized method for mandibular reconstruction. Despite its unpredictable nature and the limited degree to which it is understood, it does not share the concerns of developmental changes to donor and recipient tissues that other treatment options do. The definitive role of the periosteum in bone regeneration in any mammal remains largely unexplored. The purpose of this study was to identify the genetic determinants of PMBR in mammals through a systematic review. Methods: Our search methodology was designed in accordance with the PRISMA (Preferred Reporting Items for Systematic Review and Meta-Analysis) guidelines. We conducted a quality assessment of each publication, and evaluated the differences in gene expression between days 7 and 15. Results: A total of four studies satisfied the inclusion criteria. The subjects and tissues examined in these studies were Wistar rat calvaria in two studies, mini-pigs in one study, and calves and mice in one study. Three out of the four studies achieved the necessary quality score of ≥ 3. Gene expression analysis showed increased activity of genes responsible for angiogenesis, cytokine activities, and immune-inflammatory responses on day 7. Additionally, genes related to skeletal development and signaling pathways were upregulated on day 15. Conclusions: The results suggest that skeletal morphogenesis is regulated by genes associated with skeletal development, and the gene expression patterns of PMBR may be characterized by specific pathways.

Study on enhancing the ultrasonic image for bone densitometry (골밀도 측정을 위한 초음파 영상 개선에 관한 연구)

  • Shin, Jung-Sik;Ahn, Jung-Hwan;Kim, Hyung-Joon;Kim, Hwa-Young;Han, Seung-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

Bone density around the fixture after function of implant molar prosthesis using CBCT (임플란트 보철 기능후 고정체 주변 콘빔CT 골밀도 평가)

  • Jung, Jae-Hyun;Hwang, In-Taik;Jung, Byung-Hyun;Kim, Jae-Duk;Kang, Dong-Wan
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose : The purpose of this study was to examine the significance of increased bone density according to whether bone grafts were applied using demographic data with Cone Beam Computed Tomography (CBCT) and to compare the bone densities between before and after implant prosthesis using the Hounsfield index. Materials and Methods : Thirty-six randomly selected computed tomography (CT) scans were used for the analysis. The same sites were evaluated digitally using the Hounsfield scale with V-Implant $2.0^{TM}$, and the results were compared with maxillary posterior bone graft. Statistical data analysis was carried out to determine the correlation between the recorded Hounsfield unit (HU) of the bone graft and implant prosthesis using a Mann-Whitney U test and Wilcoxon Matched-pairs test. Results : The bone grafted maxillary posterior teeth showed an increase in the mean values from-157 HU to 387 HU, whereas non-grafted maxillary posterior teeth showed an increase from 62 HU to 342 HU. After implantation, the grafted and non-grafted groups showed significantly higher bone density than before implantation. However, the grafted group showed significantly more changes than the non-grafted group. Conclusion : Bone density measurements using CBCT might provide an objective assessment of the bone quality as well as the correlation between bone density (Hounsfield scale) and bone grafts in the maxillary molar area.

Initial Changes of Implant Stability from Installation during Early Bone Healing (임플란트 식립 후 초기 안정성의 변화)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.272-279
    • /
    • 2013
  • The concept of implant stability was basically originated from the relative condition of bone-implant interface and has some meanings for evaluation of that interface. In addtion, it has been used for the investigation of initial bone healing process after fixture installation because a degree of micromotion around interface can affect unfavorable clinical results. The purpose of this study is to investigate the mode of initial bone healing from fixture installation through prospective trial. Thirty fixtures were consecutively installed in mandibles of 26 patients with single tooth loss area and then healing abutment were secured for one-stage surgery meothod. Resonance frequency analysis was performed with one week interval during 12 weeks and periapical radiographs were taken at each month. Although marginal bone level change was not shown through observation period (P>0.05), statistical difference of implant stability was shown through 4 and 6 week (P<0.05) and was not shown after 6 week (P>0.05) according to the bone quality. Initial bone healing process is a successive process of bone resorption and favorable bone healing result might be postulated at 4 week interval after installation through RFA.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.