• 제목/요약/키워드: Bone Implant Contact

검색결과 257건 처리시간 0.025초

Influence of Implant Surface Coated with pH Buffering Agent on Early Osseointegration

  • Kang, Joo Hyun;Kim, Su-Kyoung;Pae, Hyung Chul;Park, Jin Young;Cha, Jae-Kook;Choi, Seong-Ho
    • Journal of Korean Dental Science
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2018
  • Purpose: Surface treatment with pH buffering agent has been developed to achieve higher and faster osseointegration. The aim of this study was to evaluate its influence by measuring removal torque and analyzing histological characteristics. Materials and Methods: Titanium implants with following surfaces were used in this study: sand-blasted acid-etched (SA) surface (SA group as control I group), SA surface in calcium chloride aqueous solution (CA group as control II group) and SA surface coated with pH buffering agent (pH group as test group). Removal torque test after 2 weeks and bone-to-implant contact and bone area analyses at 2 and 4 weeks were performed. Result: The rotational torque values at 2 weeks were significantly higher in pH group ($107.5{\pm}6.2Ncm$, P<0.05). The mean values of bone-to-implant contact at 2 and 4 weeks were both higher in pH group ($93.0%{\pm}6.4%$ at 2 weeks, $88.6%{\pm}5.5%$ at 4 weeks) than in SA group ($49.7%{\pm}9.7%$ at 2 weeks, $47.3%{\pm}20.1%$ at 4 weeks) and CA group ($73.7%{\pm}12.4%$ at 2 weeks, $72.5%{\pm}10.9%$ at 4 weeks) with significances (P<0.05). The means of bone area showed significantly higher numbers in pH group ($39.5%{\pm}11.3%$ at 2 weeks, $71.9%{\pm}10.9%$ at 4 weeks, P<0.05). Conclusion: Our findings demonstrated that surface modification with pH buffering agent improved early osseointegration with superior biomechanical property.

성견에서 사다리꼴형 디자인과 미세나사선을 가진 단폭경임플란트의 골유착 평가: 예비연구 (Evaluation of narrow-diameter implant with trapezoid-shape design and microthreads in beagle dogs: A pilot study)

  • 장윤영;윤정호
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.529-540
    • /
    • 2016
  • Objective: The objective of this study was to evaluate the osseointegration of narrow-diameter implant with trapezoid-shape and to evaluate the effect of coronal microthreads on trapezoid-shape narrow-diameter implant. Materials and Methods: The experimental narrow-diameter implants were classified into two groups according to absence or presence of coronal microthreads: trapezoid-shape narrow diameter implant (TN group) and trapezoid-shape narrow-diameter implant with microthreads (TNM group). They were installed alternately in bilateral mandible in three dogs. After 8 weeks, the animals were sacrificed. Resonance frequency analysis, removal torque test, and histometric analysis were performed. Results: Statistically higher implant stability quotient (ISQ) values were observed in TNM group than in TN group at the time of implant installation. However, significant ISQ values difference was not observed between groups at 8 weeks. Both groups showed significantly increased ISQ values at 8 weeks, compared to the time of implant installation. There was no significant difference between groups in removal torque test. Bone-implant contact ratio also showed no significant difference between groups in total and coronal part. Conclusion: Within the limitation of this study, it could be concluded that the trapezoid-shape design on narrow-diameter implant showed successful ossointegration, and the microthreads on coronal part did not result in significant bone-implant contact and biomechanical stability at 8 weeks.

  • PDF

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제38권sup2호
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교 (Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants)

  • 박효상;슈엔;정성화
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.295-307
    • /
    • 2006
  • 이 연구의 목적은 교정용 고정원으로 사용된 self-drilling과 self-tapping microscrew implants를 조직학적 및 생역적으로 비교하는 것이다. 28 마리의 가토에 112개의 microscrew implants (56개의 self-drilling microscrew implants 와 56개의 self-tapping microscrew implants)를 식립하였다. Self-tapping microscrew implants는 0.9 mm 드릴로서 홈을 형성한 후 식립하였고 self-drilling microscrew implants는 홈을 형성하지 않고 바로 식립하였다. 교정력은 식립 직후 바로 NiTi coil spring을 연결하여 가하였으며 일부는 교정력을 가하지 않았고 일부는 100 gm정도의 약한 교정력을 일부는 200 gm정도의 강한 교정력을 가하였다. 실험동물은 3주 혹은 5주에 희생하였으며 72개의 비탈회 표본을 만들어 전반적인 조직학적 관찰과 조직 계측을 시행하였다. 토크 게이지로 최대 식립 토크와 최대 제거 토크를 측정하였다. 모든 microscrew implants는 실험기간 동안 안정되게 유지되었고 최대 제거 토크의 측정에는 self-drilling과 self-tapping microscrew implants 사이에 통계학적으로 유이한 차이가 없었다. 조직 관찰에서 self-tapping microscrew implants에서 골 임프란트 계면에 골결손이 더 많았고 5주에서는 새로이 형성된 미성숙 골이 더 많았다. Self-drilling microscrew implants에서 골표면 혹은 골내막으로의 골 형성이 많이 관찰되었으나 5주에서는 흡수되는 양상을 보였다. 3주에서는 self-drilling microscrew implants가 더 많은 골접촉을 보였으나 5주에서는 두 군사이에 차이가 관찰되지 않았다. 이 결과는 두 방법이 모두 microscrew implant의 식립에 사용될 수 있음을 시사하나 self-tapping microscrew implants의 경우 초기에는 약한 힘을 가하는 것이 좋을 것으로 생각된다.

하악 임플란트 Bicortication 의 응력분산효과에 관한 유한요소분석적 연구 (A STUDY ON THE EFFECT OF STRESS DISTRIBUTION OF MANDIBULAR IMPLANT BICORTICATION UTILIZING FINITE ELEMENT ALALYSIS METHOD)

  • 이양진;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.517-538
    • /
    • 1995
  • Dental implantation is a method restoring missing teeth, especially in the case of severely resorbed edentulous patient. But the direct contact between bone and implant surface, induces stress concentration to the bone and eventually becomes a cause. The purpose of this study was to compare the stress distribution patterns between following two cylindrical implant models. One group has implant apex located in the inferior cortical bone and the other in the cancellous bone. Anterior edentulous mandible was modeled with two dimensional 953,878 nodes, 995,918 elements and compared the deflection and stress distribution under the 70 N,4 load cases for 26 models having variant mandibular height and length. The result were as follows; 1. The stress concentration was more affected by the height of the mandible than implant length. 2. Bicortication mitigates the stress of upper cortical and cancellous bone area at the same height of the mandible 3. Perforation of the inferior mandibular cortex significant stress concentration. 4. Stud type porstheses induced less stress concentration to the cortical and cancellous bone than bar type prostheses. 5. Stress of implant apex for stud type was larger than that of bar type.

  • PDF

가토에 이식된 Titanium plasma Sprayed IMZ 임프란트와 골의 계면 접촉 양상에 따른 결합력에 관한 연구 (A STUDY ON SHEAR BOND STRENGTH OF INTERFACE BETWEEN BONE AND TITANIUM PLASMA SPRAYED IMZ IMPLANT IN RABBITS)

  • 한종현;한동후
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.225-243
    • /
    • 1991
  • In recent years immediate implantation has been tried by a few clinicians. This study placed IMZ implants in the rabbit femur with and without bony defects around the implant for simulating fresh extraction site. And one group with bony defects used porous hydroxyapatite ganules(HA) to fill if and the other group left the bony defects around the implant. The purpose of this study was to compare the shear bond strength and the bony contact and formation around the implant. Fifteen rabbits were divided into three groups and placed 10 IMZ implants to each group. Implant sites were surgically prepared with IMZ drills kit and implants were placed(Control), artificial bony defect was created with Apaceram drills kit around the implant sites and implants were placed(Experimental I), bony defect was filled with porous hydroxyapatite granules(Experimental II). Thereafter, rabbits were sacrificed at 8th week and specimens were prepared and pushout tested for shear bond strength of bone-implant interface immediately. Undecalcified and decalcified specimens were prepared with Vilanueva and hematoxylin-eosin stain for light microscopic finding. The results of this study were as follows. 1. In the control group, mean shear strength of bone-implant interface was $2.614{\pm}0.680$ MPa, experimental I was $0.664{\pm}0.322$ MPa, and experimental II was $2.281{\pm}0.606$ MPa. There was significant difference between control and experimental I, between experimental I and experimental II, but did not show significant difference between control and experimental II statistically. 2. In the bony formation surrounding IMZ implant of the three groups, that of cortical bone is more advanced than cancellous bone area. 3. In the histological findings of undecalcified specimens, control and experimental II showed more than 50% of bony or osteoid formation at the bony-implant interface. 4. In the histological findings of undecalcified specimens, experimental I showed less than 50% of bony or osteoid formation at the interface, and observed partial bony defect in the coronal zone. 5. In the experimental II group, were observed direct bony contact to hydroxyapatite granules, and infiltration of a few giant cells. 6. No inflammatory responses were seen around the titanium implants and the hydroxyapatite granules.

  • PDF

Calcium carbonate 및 자가골 이식술을 동반한 조직유도재생술후 생검을 통한 재생골의 조직학적 관찰 (Histologic observation of regenerated bone in human intraosseous lesion following guided tissue regeneration with calcium carbonate implant and autogenous bone graft)

  • 이용무;한수부;엄흥식;김동균
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.263-273
    • /
    • 1998
  • For histologic observation of the regenerated bone following guided tissue regeneration (GTR) using ePTFE membranes with calcium carbonate implant and autogenous bone graft, biopsies were collected from 2 patients during 5-year-postoperative surgical reentry. In both combined cases with guided tissue regeneration in conjunction with calcium carbonate implant and autogenous bone graft, significant bone fill and gain in probing attachment level was observed. In histologic examination, specimen in GTR case with calcium carbonate grafting was composed of a dense bone containing vascular channel with lamellar structure and viable bone cells in lacunae, however considerable calcium carbonate particles remained unresorbed and isolated from regenerated bone by the dense cellular and fibrous connective tissue. No formative cells could be seen in contact with remained calcium carbonate particles. In GTR case with autogenous bone grafting, specimen show was composed of a dense lamellar bone containing vascular channel, which showed normal alveolar bone architectures. The present observation indicate that guided tissue regeneration in conjunction with grafting, especially autogenous bone graft, has highly osteogenic potential, however resorbable calcium carbonate granules were not completely resorbed at 5 year postimplantation.

  • PDF

교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구 (The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant)

  • 정규림;이성자
    • 대한치과교정학회지
    • /
    • 제31권2호통권85호
    • /
    • pp.173-185
    • /
    • 2001
  • 본 연구는 경희대학교 치과대학 교정과와 Biosstech$^{\circledR)$이 개발한 교정용 골유착성 티타니움 임프란트를 이용하여 임프란트 매식 후 가해지는 교정력이 임프란트의 골유착에 미치는 영향과 임프란트 제거 후 손상된 치조골의 치유를 알아보기 위해 시행되었다. acid-etched type, sand-blasted type, sand-blasted & acid-etched type, 3종류의 교정용 임프란트 24개를 2마리 실험 동물의 구강 내에 식립하였다. dog1의 상하악 좌측에 식립한 6개 임프란트에는 식립 후 교정력을 주지 않았고, 우측에 식립한 6개 임프란트에는 식립 즉시 200-300gm의 교정력을 가하였다. dog2에서는 임프란트 식립후 4주의 치유기간을 기다린 후, 골 내에 고정되어 있는 모든 임프란트에 4주 동안 200-300gm의 교정력을 가하였다. 4주, 8주의 관찰 기간이 지난 후 실험 동물을 각각 희생시켜 임프란트와 주위 조직을 포함하는 비탈회 표본을 제작하여 광학 현미경하에서 검경하였다. 이 실험을 통해 다음과 같은 결과를 얻었다. 1. 골내 고정에 성공한 임프란트들의 식립 4주 후 조직 소견에서, 식립 즉시 교정력을 가한 임프란트와 교정력을 가하지 않은 임프란트 사이에 조직학적 차이가 없었다. 두 군 모두에서 미성숙 소주골이 임프란트 식립시 손상된 부위로 생성되고 있었으며 부분적인 골유착이 보였다. 2. 임프란트 식립 부위의 골손상이 완전히 치유되기 전에 가해진 교정력은 골유착의 진행을 방해하지 않았다. 4주의 치유기간 후 4주간 교정력을 가한 임프란트의 조직소견에서 골조직과 임프란트 계면 사이의 접촉은 더 넓은 부위로 진행되었고 나사골을 채우고 있는 신생골은 기저골의 구조와 형태를 닮은 층판골로 성숙되어 있었다. 3. 식립 후 임프란트 주위 연조직 염증이 심했던 임프란트는 대부분 탈락되거나 동요가 있었으며, 실험 동물 희생시 동요가 있었던 임프란트의 조직 소견에서 임프란트 주위는 연조직으로 둘러 쌓여 골조직과 분리되어 있었다. 4. 골내 고정에 실패한 임프란트의 식립 부위에서는 임프란트 제거 2주 후 염증 소견없이 왕성한 골형성을 나타내는 조직학적 소견이 관찰되었다.

  • PDF

하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석 (Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load)

  • 배숙진;정재헌;정승미
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

The impact of polydeoxyribonucleotide on early bone formation in lateral-window sinus floor elevation with simultaneous implant placement

  • Dongseob Lee;Jungwon Lee;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제53권2호
    • /
    • pp.157-169
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate the impact of polydeoxyribonucleotide (PDRN) on histologic outcomes when implant placement and lateral sinus floor elevation are performed simultaneously. Methods: Three bimaxillary premolars (P2, P3, and P4) were extracted from 4 beagle dogs 2 months before lateral sinus floor elevation. After lateral elevation of the sinus membrane, each sinus was allocated to either the test or control group. Sinuses underwent either 1) collagenated synthetic bone graft with PDRN following lateral sinus floor elevation (test group) or 2) collagenated synthetic bone graft without PDRN after lateral sinus floor elevation (control group). Eight weeks after the surgical procedure, all animals were euthanised for a histologic and histomorphometric assessment. Augmented height (AH), protruding height (PH), and bone-to-implant contact in pristine (BICp) and augmented (BICa) bone were measured. The composition of the augmented area, which was divided into 3 areas of interest located in coronal, middle and apical areas (AOI_C, AOI_M, and AOI_A), was calculated with 3 parameters: the area percentage of new bone (pNB), residual bone graft particle (pRBP), and fibrovascular connective tissue (pFVT). Results: AH, PH, BICp, BICa total, BICa coronal, and BICa middle values were not significantly different between sinuses in the control and test groups (all P>0.05). The BICa apical of sinuses in the test group (76.7%±9.3%) showed statistically higher values than those of sinuses in the control group (55.6%±22.1%) (P=0.038). pNB, pRBP, and pFVT showed statistically significant differences between the 2 groups in AOI_A (P=0.038, P=0.028, and P=0.007, respectively). pNB, pRBP, and pFVT in AOI_C and AOI_M were not significantly different between samples in the control and test groups (all P>0.05). Conclusions: The histologic findings revealed that lateral sinus floor elevation with PDRN might improve early new bone formation and enable higher bone-to-implant contact.