• Title/Summary/Keyword: Bone Density

Search Result 1,488, Processing Time 0.035 seconds

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Effect of High Calcium Diet on the Zinc and Copper Balance in Korean Female Adolescents (청소년기 여자에서 고칼슘 섭취가 아연과 구리 평형에 미치는 영향)

  • 최보영;남혜경;황용주;김선희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.894-899
    • /
    • 2001
  • Intakes and excretions of zinc and copper were determined for 8 female adolescents (aged 16.4$\pm$0.5 y; body mass index 20.4$\pm$1.3kg/$m^2$; body fat 33.3$\pm$2.5%; bone mineral density of lumbar spine in L2-L4; 0.96$\pm$0.08g/$\textrm{cm}^2$) when they consumed diets basal and high in calcium for 6 days each. All subjects consumed a basal Ca diet containing 800 mg, Korean RDA level of the subjects, and a high Ca diet containing 1200mg, RDA plus 2 SDs of calcium intake. The diets provided 58% of energy intake as carbohydrate, 25% as fat, and 17% as protein. Food, urine and fecal samples were collected during the last 3 days of each feeding period and were assayed. Mean daily intakes on the basal and high calcium diets, respectively, were 6.57 and 6.37 mg for zinc and 910 and 812 $\mu\textrm{g}$for copper. Fecal excretion of copper and zinc in relation to intake was significantly greater on the high calcium than on the basal calcium diet. Hence, apparent absorption rate was significantly lowered from 98.7% on the basal calcium diet to 97.9% on the high calcium diet for zinc from 66.3% to 56.4% for copper, respectively. Urinary loss of copper was not detectable but that of zinc was 0.38mg on the basal diet and 0.47mg on the high calcium diet. Copper retention was 899$\pm$105$\mu\textrm{g}$/day on the basal calcium diet and 792$\pm$20.8$\mu\textrm{g}$/day on the high calcium diet, and zinc retention was 3.95$\pm$0.91mg/day and 3.11$\pm$0.89mg/day. Thus, copper and zinc retention was significantly decreased on the high calcium diet (p<0.05). Summarizing the results, apparent absorption and retention of zinc and copper were significantly decreased by calcium supplementation. Therefore, it is suggested that interactions among minerals should be considered in determining RDA.

  • PDF

Prevalence of Osteoporosis among Male Adults with Apparently Radiolucent Lumbar Vertebral Bodies on the Plain Radiographs (단순 영상에서 요추체의 음영이 감소된 성인 남성에서의 골다공증 유병률)

  • Kim, Kook Jong;Lim, Sung Joon;Kim, Yong Min;Lee, Hyung Ki;Kim, Geon Jung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.491-497
    • /
    • 2021
  • Purpose: To investigate the prevalence of osteoporosis or osteopenia via dual-energy X-ray absorptiometry bone mineral density (DEXA BMD) in adult males who showed radiolucent lumbar vertebra on the plain radiographs. Materials and Methods: The DEXA BMD values of 98 adult males, who showed radiolucent vertebrae on plain X-rays, were compared with those of the control group (n=168) and osteoporosis-related fracture group (n=113) by statistical analysis. The World Health Organization (WHO) method (lower value between the mean lumbar and femur neck) and the Hansen's method (lowest lumbar vertebra) were used to determine osteoporosis. Results: The mean and standard deviation of the BMD value of each group was -1.4 (±1.2) in the suspicious group, -0.8 (±1.1) in the control group, and -2.4 (±1.0) in the fracture group, respectively; the difference was statistically significant. Using the WHO method, the prevalence ratio of osteoporosis was 17.3% in the suspicious group, 8.3% in the control group, and 45.1% in the fracture group, respectively. Osteopenia was observed in 40.8% of the suspicious group. Hansen's method (lowest lumbar vertebra) revealed the prevalence of osteoporosis in 30.6% of the suspicious group, 17.9% of the control group, and 62.0% of the fracture group. Conclusion: Approximately 17.3% of the suspicious group was diagnosed with osteoporosis, and 40.8% were osteopenic by a confirmative BMD study (WHO criteria) among the adult males showing apparent radiolucency on plain X-rays. The control group also showed an 8% prevalence of osteoporosis. These results suggest that males also are vulnerable to osteoporosis. Therefore, a BMD study should also be used for males, especially for the people showing lumbar vertebrae with radiolucent features.

The Effect of Distal Hooks in Thoracolumbar Fusion Using a Pedicle Screw in Elderly Patients (척추경 나사못을 이용한 고령 환자의 흉요추부 유합에서 원위부 갈고리의 효과)

  • Lee, Dong-Hyun;Kim, Sung-Soo;Kim, Jung-Hoon;Lim, Dong-Ju;Choi, Byung-Wan;Kim, Jin-Hwan;Kim, Jin-Hyok;Park, Byung-Ook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.83-91
    • /
    • 2017
  • Purpose: To investigate the clinical outcomes of distal hook augmentation using a pedicle screw in thoracolumbar fusion in elderly patients. Materials and Methods: This retrospective multicenter study recruited 20 patients aged 65 years or older, who underwent anterior support and long level posterior fusion in the thoracolumbar junction with a follow-up of one year. To assess the effect of distal hook augmentation, the patients were divided into two groups; the pedicle screw with hook group (PH group, n=10) and the pedicle screw alone group (PA group, n=10). Results: The average age was 72.4 years (65-83 years). The average fusion segment was 4.6 segments (3-6 segments). There were no significant differences in age, sex, causative diseases, bone mineral density of lumbar and proximal femur, number of patients with osteoporosis, and number of fused segments between the two groups (p≥0.05). At 1 year follow-up after surgery, parameters related with distal screw pullout were significantly worse in the PA group. No patients in the PH group had distal screw pullout. However, six patients (60%, 6/10) in the PA group had distal screw pullout. There were no significant differences in the progression of distal junctional kyphosis between the two groups. Conclusion: Distal hook augmentation is an effective procedure in protecting distal pedicle screws against the pullout when long level thoracolumbar fusion was performed in elderly patients aged 65 years or older.

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Relation between Health Status and Intake of Soy Isoflavone among Adult Women in Seoul (서울 거주 성인 여성의 대두 이소플라본 섭취와 건강과의 관련성)

  • Lee, Min-June;Sohn, Chun-Young;Park, Ok-Jin
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.2
    • /
    • pp.218-230
    • /
    • 2010
  • This study was conducted to survey isoflavone intake among adult women in menopause with diseases such as metabolic syndrome and osteoporosis and to analyze the relationship between each of these chronic diseases followed by isoflavone intake and the related health risk index. The average age of the subjects was 49.97 years old, while that of the pre-menopausal subjects was 45.14 years, and the post-menopausal subjects was 55.99 years. The average body mass index (BMI), waist-hip circumference, body fat percentage, blood pressure, blood sugar and blood lipid content of the post-menopausal subjects were higher in significant difference than those of the pre-menopausal subjects. The bone density of the hip and spine in post-menopausal subjects was lower in significant difference than that of the pre-menopausal subjects. After menopause, the subjects had a lower ratio of individuals at risk of anemia when compared with the subjects before menopause, but had higher health risk ratio related to each type of chronic disease, including obesity, hypertension, high cholesterol and osteoporosis than the subjects before menopause. The intake frequency of each soybean food was similar among subjects before/after menopause. The most common soybean based foods consumed by the subjects were soybean, soybean curd and soybean paste. The average daily intake level of isoflavone among subjects before menopause was 25.48 mg, while that of subjects after menopause was 32.25 mg. Evaluation of the distribution of the isoflavone level revealed that the pre-menopausal subjects consumed 3.29~78.36 mg and the post-menopausal subjects consumed 3.18~116.59 mg. The intake level by each individual varied greatly. The pre-menopausal subjects had a low BMI index and systolic blood pressure as much as their isoflavone intake level was high. Additionally, the post-menopausal subjects had a low menarche age and high menopause age when their isoflavone intake level was high, the BMI index and waist-hip circumference ratio was highest among individuals with lowest isoflavone intake level. This study showed that there was a possible relationship between soybean isoflavone intake and health problems such as obesity, high cholesterol, and osteoporosis in women after menopause with diseases such as metabolic syndrome and osteoporosis, even if this relationship was not great.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF