• 제목/요약/키워드: Bone Densitometry

검색결과 59건 처리시간 0.025초

백서의 두개골 결손 모델에 있어 지방유래 줄기세포가 탈회골의 골유도에 미치는 영향 (Effect of Murine Adipose Derived Stem Cell(ADSC) on Bone Induction of Demineralized Bone Matrix(DBM) in a Rat Calvarian Defect Model)

  • 허찬영;이은혜;서석진;은석찬;장학;백롱민;민경원
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.631-636
    • /
    • 2008
  • Purpose: Adipose tissue-derived stem cells(ADSC) has an osteoconductive potential and demineralized bone matrix(DBM) is an osteoinductive material. A combination of DBM and ADSC wound probably create osteoinductive properties. The purpose of this study is to determine the effect of the combination of DBM and ADSC mixture on healing of rat calvarial defect. Methods: Thirty adult male Sprague-Dawley rats were randomized into 3 groups(n=10) as 1) Control, 2) DBM alone, 3) DBM with ADSC mixture. DBM with ADSC mixture group has had a 3-day preculture of ADSC from groin fat pad. An 6 mm critical size circular calvarial defect was made in each rat. Defect was implanted with DBM alone or DBM with ADSC mixture. Control defect was left unfilled. 6 and 12 weeks after the implantation, the rats were sacrificed and the defects were evaluated by histomorphometric and radiographical studies. Results: Histomorphometric analysis revealed that DBM with ADSC mixture group showed significantly higher bone formation than DBM alone group(p<0.05). Although radiographs from DBM alone group and DBM with ADSC group revealed similar diffuse radiopaque spots dispersed throughout the defect. Densitometric analysis of calvarial defect revealed DBM with ADSC mixture group significantly higher bone formation than DBM alone(p<0.05). There was correlation of densitometry with new bone formation(Spearman's correlation of coefficient=0.804, 6 weeks, 0.802, 12 weeks). Conclusion: The DBM with ADSC mixture group showed the best healing response and the osteoinductive properties of DBM were accelerated with ADSC mixture. It will be clinically applicable that DBM and ADSC mixture in plastic and reconstructive surgery, such as alveolar cleft and congenital facial deformities that bone graft should be required.

가토에서 조직 재생 이식재로서 무세포성 진피 기질의 효용 (USEFULNESS OF ACELLULAR DERMAL MATRIX GRAFT ON THE TISSUE REGENERATION IN RABBITS)

  • 최종학;류재영;유선열
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권2호
    • /
    • pp.220-229
    • /
    • 2008
  • Purpose: The present study was aimed to examine the effect of acellular dermal matrix ($AlloDerm^{(R)}$) grafted to the experimental tissue defect on tissue regeneration. Materials and Methods: Male albino rabbits were used. Soft tissue defects were prepared in the external abdominal oblique muscle. The animals were then divided into 3 groups by the graft material used: no graft, autogenous dermis graft, and $AlloDerm^{(R)}$ graft. The healing sites were histologically examined at weeks 4 and 8 after the graft. In another series, critical sized defects with 8-mm diameter were prepared in the right and left iliac bones. The animals were then divided into 5 groups: no graft, grafted with autogenous iliac bone, $AlloDerm^{(R)}$ graft, $AlloDerm^{(R)}$ graft impregnated with rhBMP-2, and $AlloDerm^{(R)}$ graft with rhTGF-${\beta}1$. The healing sites of bone defect were investigated with radiologic densitometry and histological evaluation at weeks 4 and 8 after the graft. Results: In the soft tissue defect, normal healing was seen in the group of no graft. Inflammatory cells and foreign body reactions were observed in the group of autogenous dermis graft, and the migration of fibroblasts and the formation of vessels into the collagen fibers were observed in the group of $AlloDerm^{(R)}$ graft. In the bone defect, the site of bone defect was healed by fibrous tissues in the group of no graft. The marked radiopacity and good regeneration were seen in the group of autogenous bone graft. There remained the traces of $AlloDerm^{(R)}$ with no satisfactory results in the group of $AlloDerm^{(R)}$ graft. In the groups of the $AlloDerm^{(R)}$ graft with rhBMP-2 or rhTGF-${\beta}1$, there were numerous osteoblasts in the boundary of the adjacent bone which was closely approximated to the $AlloDerm^{(R)}$ with regeneration features. However, the fibrous capsule also remained as in the group of $AlloDerm^{(R)}$ graft, which separated the $AlloDerm^{(R)}$ and the adjacent bone. Conclusions: These results suggest that $AlloDerm^{(R)}$ can be useful to substitute the autogenous dermis in the soft tissue defect. However, it may not be useful as a bone graft material or a carrier, since the bone defect was not completely healed by the bony tissue, regardless of the presence of osteogenic factors like rhBMP-2 or rhTGF-${\beta}1$.

이중에너지 X선 흡수계측법을 이용한 폐경기 여성의 요추 및 근위 대퇴부의 골밀도 비교 연구 (A Comparative Study on BMD of Lumbar Spine and Proximal Femur in Post-Menopausal Women Using Dual Energy X-ray Absorptiometry)

  • 윤한식;모은희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.41-46
    • /
    • 1999
  • Osteoporosis, which causes mainly fracture of the spine, proximal femur and distal radius by minimal trauma, is a major public health problem and its prevalence is steadily increasing in Korea according to the development of public health care. There are reliable methods for diagnosis based on bone densitometry. Early detection and intervention are important for reducing the incidence of fractures. A consensus definition of osteoporosis, based on bone density measurement, has been developed by the World Health Organization(WHO). In this study, bone mineral density(RMD) was measured by dual energy x-ray absorptiometry(DEXA) at the proximal femur and lumbar spine in 132 post-menopausal women. The purpose of this study is to find influential factors on the BMD of the proximal femur and the lumbar spine and to analyze correlation between BMD and the problematic factors. We obtained the following results : 1. Mean BMD score, T-score and Z-score of the proximal femur were $0.81(g/cm^2)$, -2.45(S.D.) and -2.09(S.D.) respectively and in the lumbar spine were $0.83(g/cm^2)$, -2.02(S.D.), -2.43(S.D.) respectively. 2. In correlation analysis between BMD and many factors, correlation coefficients were -0.467, 0.212, -0.321 and 0.241 in age, height, duration after menopause respectively. BMI and the residuals were comparatively small. 3. Correlation coefficients to age matched BMD, in height and body weight were 0.222 and 0.241, in age and duration after menopause were -0.268, -0.282. 4. The fracture threshold of proximal femur BMD to the 90th percentile was $0.845(g/cm^2)$. 5. At the result of multiple regression analysis, age, body weight, $BMI(kg/m^2)$ and duration after menopause described as significant variables.

  • PDF

근위골절술을 위한 Staple 설계 (A Newly Designed Miniplate Staple for High Tibial Osteotomy)

  • 문무성;배대경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

40세 이후 남성의 골밀도 관련 요인과 골다공증의 유병률 (Factors Influencing in the Bone Mineral Density and the Incidence of the Osteoporosis among Male Older than 40 Years Old)

  • 모은희;조정근;이상호;임청환;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제8권10호
    • /
    • pp.241-250
    • /
    • 2008
  • 의학과 과학의 발전으로 인한 고령인구의 증가로 여성에게 뿐만이 아니라 남성에서도 골다공증에 의한 골절의 빈도가 증가하면서 남성 골다공증에 대한 관심이 높아지고 있다. 이에 본 연구는 40세 이후 남성의 골밀도에 관련된 요인을 알아보고 이러한 병인으로 인한 골다공증의 유병률을 조사하여 남성 골다공증의 예방과 치료대책을 위한 기초 자료를 제공하고자 한다. 건강 검진에서 골밀도 검사를 시행한 40세 이후 남성을 대상으로 한 본 연구에서 L-spine의 골감소증과 골다공증은 각각 45%, 12.9%의 유병률을 보였고, Femur에서는 51.9%, 7.63%의 유병률을 보여 미국이나 유럽에서 50세 이상 남성을 대상으로 한 연구 결과 수치보다 높게 관찰되었다. L-spine의 경우 연령과 골감소증 및 골다공증 유병률이 유의한 차이를 보였고, Femur에서 역시 연령과 골다공증의 유병률이 유의한 연관성을 가지는 것으로 조사되었다. 연령이 증가할수록 L-spine, Femur 두 부위 모두 평균 BMD가 낮아지는 것으로 조사되었고, 체중이 증가할수록, 체질량지수(BMI, kg/$m^2$)가 높을수록 골다공증의 유병률은 감소하는 음의 상관관계를 가졌다. 운동, 흡연, 음주는 골다공증의 유병율과 유의한 연관성이 없는 것으로 조사되었으나, 운동의 횟수, 흡연기간, 음주횟수는 골 양을 변화시켜 남성 골밀도에 영향을 주는 인자가 되고 있다.

골다공증을 동반한 골반 골절환자의 보존적 치료에 대한 증례 (A Case Report on Pelvic Fracture Accompanied with Osteoporosis Improved by Conservative Treatment)

  • 문수정;이유진;고연석;송용선;이정한
    • 척추신경추나의학회지
    • /
    • 제5권1호
    • /
    • pp.49-56
    • /
    • 2010
  • 본 증례는 골절 치유 과정에서 치유기간의 연장을 가져올 수 있는 심한 골다공증에 이환된 환자에게 약한 충격으로 야기된 골반골절 환자에 대하여 침상 안정과 함께 침구 및 부항치료, 약침치료, 한약물치료를 실시하여, 환자가 느끼는 통증 정도를 측정하는 VAS 및 일상 생활 장애의 정도를 반영하는 ODI의 감소, 3차원 전산화단층촬영 상 골절 치유라는 결과를 얻었기에 이를 보고하는 바이다.

  • PDF

재구성 연산 방식에 따른 흉부의 정상 조직과 종괴의 CT 밀도 측정 (CT Densitometry of Normal Tissue and Mass of Lung according to Reconstruction Algorithm)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권2호
    • /
    • pp.39-45
    • /
    • 2002
  • 흉부 종괴와 정상 조직의 CT밀도에 대해 재구성 연산방식에 따른 영향을 평가하기 위해 흉부 종괴가 있는 50명의 환자를 대상으로 연구를 시행하였다. CT영상은 연부, 표준, 골 그리고 선예의 4가지 재구성 연산법을 사용하여 평가하였다. 그 결과, 관심영역에 대한 폐종괴 밀도의 최대 차이는 평균 1HU 미만으로 나타났다. 또한 폐종괴의 조영증강의 최대 차이는 ROI 0.5, 3, $6cm^2$에서 각각 $0.1{\sim}3.2,\;0.1{\sim}2.8,\;0.0{\sim}2.1\;HU$로 나타났다. 흉부의 정상 조직에서 평균 밀도는 골 연산법에서 가장 높았으나, 4가지 재구성 연산법에 따라 의미 있는 차이는 없었다(P = 1.00).

  • PDF

생화학적 표식자에 따른 성인들의 골밀도 분석 (Analysis of Bone Mineral Density According to the Biochemical Variable Markers in Adults)

  • 김순근;권대철;송운흥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.411-418
    • /
    • 2009
  • 성인들의 생화학적 표식자를 검사해 골밀도에 직접 관여할 수 있는 중요한 유전적 또는 생화학적 인자들을 규명하고 성인들의 골다공증 병태생리에 관련된 정보를 제공하고 골다공증의 위험인자 등과의 관련요인을 분석하였다. 2007년 9월 12일부터 2008년 3월 18일까지 대학병원 건강증진센터에 내원한 남성 568명 여성 430명으로 총 998명 수진자를 대상으로 양 에너지 엑스선 골밀도 측정기를 이용하여 대퇴경부 및 척추의 골밀도를 측정하였다. 골밀도에 직접 관여하는 혈액의 생화학적 표식자는 인, 칼슘, 관절염, 헤모글로빈, 글루코오스, 간 기능검사의 GOT, GPT, $\gamma$-GTP를 측정하여 성인들의 골다공증 병태생리에 관련된 정보를 제공하여, 골다공증의 진단과 치료 및 예방에 생화학적 위험인자를 분석하여 관련요인을 조사하였다. 남성은 대퇴경부 및 척추의 골밀도는 20대에서 가장 높았고, 60대에서 대퇴경부와 척추의 골밀도가 가장 낮았다. 여성은 대퇴경부의 골밀도가 20대에서 가장 높았으나 척추는 40대에서 골밀도가 가장 높았고, 60대에서 대퇴경부와 척추의 골밀도가 가장 낮았다. 여성들 중 폐경 후의 여성들보다 폐경 전의 여성들이 골밀도가 유의하게 높았으며, 남성의 생화학적 표식자 인에서 정상 기준치 이상 군에서 대퇴경부와 척추에서 골밀도가 높았으며 여성은 정상치군일 때가 대퇴경부와 척추에서 골밀도가 높게 나타났다. 나이가 많아짐에 따라 골밀도는 낮아지고 체중이 높아지면 골밀도는 높아졌다.

  • PDF

골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계 (Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman)

  • 이강일;최민주
    • 한국음향학회지
    • /
    • 제28권6호
    • /
    • pp.542-547
    • /
    • 2009
  • 본 in vivo 연구에서는 36명의 골다공증 여성을 대상으로 요추골 및 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계를 조사하였다 2-4번 요추골 및 우측 대퇴골 경부의 단위면적당 골밀도는 이중에너지 X-선 흡수계측법을 이용하여 측정되었다. 우측 종골의 음속은 초음파 골밀도 측정기를 이용하여 측정되었다. 각 측정값 사이의 상관관계를 분석하기 위하여 Pearson 상관계수 (r) 및 유의수준 (p)이 이용되었다. 요추골 골밀도와 대퇴골 골밀도 사이에는 매우 높은 양의 상관관계가 나타났다 (r=0.81). 요추골 및 대퇴골 골밀도는 연령과 음의 상관관계를 보였다 (r=-0.52 및 r=-0.55). 종골 음속과 연령 사이에도 음의 상관관계가 나타나는 것을 알 수 있었다 (r=-0.45). 종골 음속은 요추골 및 대퇴골 골밀도와 비교적 높은양의 상관관계를 보였으며, 요추골 골밀도보다 대퇴골 골밀도와 더 높은 상관관계를 나타냈다 (r=0.54 및 r=0.62). 그러나 이는 종골 음속이 종골 골밀도와 갖는 상관관계에 비하여 낮으므로 종골 음속은 골절률이 가장 높은 요추골 및 대퇴골부위의 골밀도를 평가하기에 최적의 지표가 아님을 알 수 있었다. 그러므로 요추골 및 대퇴골 부위의 골밀도를 보다 정확히 평가하기 위하여 이 부위의 음향특성을 직접 측정할 수 있는 정량적 초음파 기술을 개발할 필요가 있다.

3D 프린팅기술을 이용한 골밀도 정도관리 대퇴골 팬텀 제작 및 유용성 평가 (Evaluation of Usefulness and Fabrication of Femur Phantom on Quality Control of Bone Mineral Density Using 3D Printing Technology)

  • 홍다영;이정;이준호;문재원;오한샘;정유원;진성현;홍종민;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.1-8
    • /
    • 2023
  • As the demand for bone mineral density testing increases in Korea, which is close to an aging society, it is necessary to evaluate the repeatability of equipment such as femur phantom other than l-spine for more accurate diagnosis. However, in clinical practice, it is often not possible to proceed such evaluation due to insufficient quality control conditions. Therefore, this study is to evaluate the usefulness of the femur phantom after fabricating the same using 3D printing technology. The femur phantom was output using GlowFill filament and FDM 3D printing type. Each phantom was repeatedly scaned 20 times to compare whether the existing l-spine phantom and the fabricated femur phantom were suitable as a phantom for quality control. Each time the seven researchers took three times, the location of the femur phantom was readjusted, and then scanned to confirm the error between the researchers. As a result of conducting repeatability evaluation using femur phantom, the coefficient of variation rate was 2%, which was within the minimum precision tolerance of 2.5%. The reproducibility between the researcher was also found to be suitable as the average coefficient of variation was 0.031 and the coefficient of variation rate was 3.1%, which was within the minimum precision error range of 5%. In conclusion, it is considered that the prospective attitude and usefulness of the femur phantom fabricated by 3D printing in clinical practice will be sufficient.