• 제목/요약/키워드: Bone/implant interfaces

검색결과 18건 처리시간 0.021초

STRESS ANALYSIS WITH NONLINEAR MODELLING OF THE LOAD TRANSFER CHARACTERISTICS ACROSS THE OSSEOINTEGRATED INTERFACES OF DENTAL IMPLANT

  • Lee Seung-Hwan;Jo Kwang-Hun
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.267-279
    • /
    • 2004
  • A modelling scheme for the stress analysis taking into account load transfer characteristics of the osseointegrated interfaces between dental implant and surrounding alveolar bone was investigated. Main aim was to develop a more realistic simulation methodology for the load transfer at the interfaces than the prefect bonding assumption at the interfaces which might end up the reduced level in the stress result. In the present study, characteristics of osseointegrated bone/implant interfaces was modelled with material nonlinearity assumption. Bones at the interface were given different stiffness properties as functions of stresses. Six different models, i.e. tens0, tens20, tens40, tens60, tens80, and tens100 of which the tensile moduli of the bones forming the bone/implant interfaces were specified from 0, 20, 40, 60, 80, and 100 percents, respectively, of the compressive modulus were analysed. Comparisons between each model were made to study the effect of the tensile load carrying abilities, i.e. the effectivity of load transfer, of interfacial bones on the stress distribution. Results of the present study showed significant differences in the bone stresses across the interfaces. The peak stresses, however, were virtually the same regardless of the difference in the effectivity of load transfer, indicating the conventional linear modelling scheme which assumes perfect bonding at the bone/implant interface can be used without causing significant errors in the stress levels.

Lumbar spine 의 뼈와 Interbody cage의 접촉면에서 기계공학적 민감성 고찰 (The Mechanical Sensitivity at Interfaces between Bone and Interbody Cage of Lumbar Spine Segments)

  • 김용
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권3호
    • /
    • pp.295-301
    • /
    • 2000
  • 뼈의 성장에 미치는 많은 요소들 중에서 implant의 상대적인 미세운동(relative micromotion)은 뼈의 implant와의 접합을 방해하는 것으로 알려져 왔다. 그런데 이러한 상대적인 운동 및 spinal stability에 직접적으로 영향을 주는 하중조건, spinal material의 물성치, spinal geometry 및 뼈와 implant의 접촉면에서의 마찰계수를 고려하기 위하여, 하나의 titanium interbody cage 가 삽입된 human lumbar segments (L4-L5)의 유한요소 모델이 개발되었다. 이러한 유한요소 모델의 해석을 통하여 상대적인 미세운동, Posterior의 수직적인 변위, von Mises 응력 및 마찰력이 예측되었다. Cancellous bone. annulus fibers 및 ligaments의 기계적인 물성치의 감소 또는 접촉면에서의 마찰계수의 감소는 상대적인 미세운동 (relative micromotion or slip distance)을 증가 시켰다. 접촉면에서의 normal force는 뼈의 밀도 (cancellous bone density) 가 감소하거나 접촉마찰계수가 증가하면 감소했다. 특히 하중조건에 있어서, compressive preload에 대한 torsion의 추가는 접촉면의 anterior부위에서 상대적인 미세운동을 증가 시켰다. 하지만 디스크면적이 증가할수록 상대적인 미세운동은 감소했다. 결론적으로, 접촉면의 기계공학적 거동 (Relative micromotion, stress response, posterior axial displacement and contact normal force)은 접촉면의 마찰계수 뼈의 밀도, 하중조건 및 노화에 따른 형상/물성의 변화에 매우 민감함을 보이고있다.

  • PDF

임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구 (EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE)

  • 강상규;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권1호
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF

즉시하중시 상악 전치부에 식립된 임플란트 길이 변화에 따른 응력 분포의 삼차원 유한요소 연구 (Effect of Implant Length on the Immediate Loading at the Anterior Maxilla)

  • 이준석;김명주;권호범;임영준
    • 구강회복응용과학지
    • /
    • 제25권3호
    • /
    • pp.255-265
    • /
    • 2009
  • 즉시 하중에 대한 관심과 시도가 증가되고 있지만, 명확한 술식이 정립되어 있지는 않다. 본 연구에서는 상악 전치부 임플란트에서 즉시 하중시에 골과 임플란트에 나타나는 응력분포 양상을 3차원 유한요소법을 이용하여 알아보고자 하였다. 골질이 D3인 상악 전치부의 골모형을 구성하고, 서로 다른 길이(8.5 mm, 10.0 mm, 11.5 mm, 13.0 mm, 15.0 mm)의 직경 4.0 mm 나사형 임플란트를 식립한 모형을 제작하였다. 해석 절차의 간소화를 위하여 모든 물성은 등방성, 선형탄성, 균질성으로 가정하였다. 골-임플란트 계면은 접촉 요소법으로 처리하여 골유착이 일어나기 전 상태로 구성하였다. 지대주 장축에 120도의 각도로 지대주의 구개 절단각 중앙부에 176 N의 정하중을 가하고 응력분포를 관찰하였다. von Mises stress를 이용하여 응력을 분석한 결과 모든 모형에서 순측 피질골에 응력이 집중되었으며 피질골과 망상골의 경계부에서 최대 응력값을 나타내었다. 길이에 따른 비교시 8.5 mm 모형에서 가장 큰 최대 응력값을 나타냈으며, 임플란트 길이가 증가될수록 좀 더 양호한 응력 분포를 나타내었다. 상악 전치부 즉시 하중시에 피질골의 존재 유무는 매우 중요하며, 길이가 긴 임플란트를 식립하는 것이 유리하며, 가능하면 13.0 mm 이상의 임플란트를 식립하는 것이 즉시하중을 시행할 때 응력 분산에 유리한 것으로 판단된다.

유한요소해석을 통한 ITI Solid screw 임플랜트의 형상 특성이 골유착 단계에서 응력에 미치는 영향에 대한 연구 (FINITE ELEMENT APPROACH TO INVESTIGATE THE INFLUENCE OF THE DESIGN CONFIGURATION OF THE ITI SOLID IMPLANT ON THE BONE STRESSES DURING THE OSSEOINTEGRATION PROCESS)

  • 차상범;이규복;조광헌
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.217-228
    • /
    • 2006
  • Statement of problem: Standard type of ITI solid implant model in the 6.2mm thick jaw bone was axisymmetrically modelled for finite element stress analyses. Purpose: Primary objective was to investigate the influences or the characteristic design configuration of the ITI solid implant model on the bone stress with the course of osseointegration process at the bone/implant interfaces. To simulate the characteristics of the osseointegration process, five different stages of the bone/implant interface model were implemented. As load conditions, vertical load of 50N was taken into consideration. Bone at the cervical region of implant was the areas of concern where the higher level of stress were likely to take place. Results: The results indicated that rather slightly different stress level could be obtained as a function of the osseointegration conditions. Conclusion: Under vertical load, the lower level of stress was observed at the cervical cortical bone in the initial and final stages of osseointegration. Relatively higher stress level, however, was observed during the transitional stages where the osseointegration at the cancellous bone interface were yet to fully develop.

하악피개의치에서 임플랜트의 식립각도에 따른 칸틸레버 길이의 감소효과가 응력분포 양상에 미치는 영향 -삼차원 유한요소법을 이용한 분석- (FINITE ELEMENT ANALYSIS OF THE EFFECT OF CANTILEVER AND IMPLANT ORIENTATION ON STRESS DISTRIBUTION IN A MANDIBULAR IMPLANT-SUPPORTED BAR OVERDENTURE)

  • 박준수;이성복;권긍록;우이형
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.444-456
    • /
    • 2007
  • Statement of problem: Implant inclination and cantilever loading increse loads distributed to implants, potentially causing biomechanical complications. Controversy exists regarding the effect of the intentionally distal-inclined implant for the reduction of the cantilever length. Purpose: This study investigated the stress distribution at the bone/implant interface and prostheses with 3D finite element stress analysis by using four different cantilever lengths and implant inclinations in a mandibular implant-supported bar overdenture. Material and methods: Four 3-D finite element models were created in which 4 implants were placed in the interforaminal area and had four different cantilver lengths(10, 6.9, 4 and 1.5mm) and distal implant inclinations$(0^{\circ},\;15^{\circ},\;30^{\circ}\;and\;45^{\circ})$ respectively. Vortical forces of 120N and oblique forces of 45N were applied to the molar area. Stress distribution in the bone around the implant was analysed under different distal implant inclinations. Results: Analysis of the von Mises stresses for the bone/implant interfaces and prostheses revealed that the maximum stresses occurred at the most distal bone/implant interface and the joint of bar and abutment, located on the loaded side and significantly incresed with the implant inclinations, especially over $45^{\circ}$. Conclusion: Within the limitations of this study, it was suggested that too much distal inclination over 45 degrees can put the implant at risk of overload and within the dimension of the constant sum of a anterior-posterior spread and cantilever length, a distal implant inclination compared to cantilever length had the much larger effect on the stress distribution at the bone/implant interface.

Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers

  • Tribst, Joao Paulo Mendes;Dal Piva, Amanda Maria de Oliveira;Borges, Alexandre Luiz Souto;Rodrigues, Vinicius Aneas;Bottino, Marco Antonio;Kleverlaan, Cornelis Johannes
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.67-74
    • /
    • 2020
  • PURPOSE. This study evaluated the influence of prosthesis weight and number of implants on the bone tissue microstrain. MATERIALS AND METHODS. Fifteen (15) fixed full-arch implant-supported prosthesis designs were created using a modeling software with different numbers of implants (4, 6, or 8) and prosthesis weights (10, 15, 20, 40, or 60 g). Each solid was imported to the computer aided engineering software and tetrahedral elements formed the mesh. The material properties were assigned to each solid with isotropic and homogeneous behavior. The friction coefficient was set as 0.3 between all the metallic interfaces, 0.65 for the cortical bone-implant interface, and 0.77 for the cancellous bone-implant interface. The standard earth gravity was defined along the Z-axis and the bone was fixed. The resulting equivalent strain was assumed as failure criteria. RESULTS. The prosthesis weight was related to the bone strain. The more implants installed, the less the amount of strain generated in the bone. The most critical situation was the use of a 60 g prosthesis supported by 4 implants with the largest calculated magnitude of 39.9 mm/mm, thereby suggesting that there was no group able to induce bone remodeling simply due to the prosthesis weight. CONCLUSION. Heavier prostheses under the effect of gravity force are related to more strain being generated around the implants. Installing more implants to support the prosthesis enables attenuating the effects observed in the bone. The simulated prostheses were not able to generate harmful values of peri-implant bone strain.

Finite element analysis in static and dynamic behaviors of dental prosthesis

  • Djebbar, N.;Serier, B.;Bouiadjra, B. Bachir
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.65-78
    • /
    • 2015
  • In recent years, implants have gained growing importance in all areas of medicine. The success of the treatment depends on many factors affecting the bone-implant, implant-abutment and abutment-prosthesis interfaces. In this paper, static and dynamic behaviors of the dental prosthesis are investigated. Three-dimensional finite element models of dental prosthesis were constructed. Dynamic loads in 5 sec applied on occlusal surface. Therefore, FEA was selected for use in this study to examine the effect of the static and dynamic loads on the stress distribution for an implant-supported fixed partial denture and supporting bone tissue.

Sinus augmentation with poly(ε) caprolactone-β tricalcium phosphate scaffolds, mesenchymal stem cells and platelet rich plasma for one-stage dental implantation in minipigs

  • Jeong-Hun Nam;Akram Abdo Almansoori;Oh-Jun Kwon;Young-Kwon Seo;Bongju Kim;Young-Kyun Kim;Jong-Ho Lee;KangMi Pang
    • Journal of Periodontal and Implant Science
    • /
    • 제53권3호
    • /
    • pp.218-232
    • /
    • 2023
  • Purpose: This study evaluated the efficacy of a tube-shaped poly(ε) caprolactone - β tricalcium phosphate (PCL-TCP) scaffold with the incorporation of human umbilical cord-derived mesenchymal stem cells (hUCMSCs) and platelet-rich plasma (PRP) for bone regeneration in the procedure of single-stage sinus augmentation and dental implantation in minipigs. Methods: Implants were placed in the bilateral sides of the maxillary sinuses of 5 minipigs and allocated to a PCL-TCP+hUCMSCs+PRP group (n=5), a PCL-TCP+PRP group (n=5), and a PCL-TCP-only group (n=6). After 12 weeks, bone regeneration was evaluated with soft X-rays, micro-computed tomography, fluorescence microscopy, and histomorphometric analysis. Results: Four implants failed (2 each in the PCL-TCP+hUCMSCs+PRP and PCLTCP+hUCMSC groups). An analysis of the grayscale levels and bone-implant contact ratio showed significantly higher mean values in the PCL-TCP+hUCMSCs+PRP than in the PCL-TCP group (P=0.045 and P=0.016, respectively). In fluoromicroscopic images, new bone formation around the outer surfaces of the scaffolds was observed in the PCLTCP+hUCMSCs+PRP group, suggesting a tenting effect of the specially designed scaffolds. Bone regeneration at the scaffold-implant interfaces was observed in all 3 groups. Conclusions: Using a tube-shaped, honeycombed PCL-TCP scaffold with hUCMSCs and PRP may serve to enhance bone formation and dental implants' osseointegration in the procedure of simultaneous sinus lifting and dental implantation.

표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구 (An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures)

  • 예선혜;조진현;이청희
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.203-211
    • /
    • 2015
  • 목적: 완전한 골-임플란트 결합을 가졌던 임플란트가 갑자기 골유착을 잃은 경우의 시간에따른 재골유착을 연구하기 위함이다. 연구 재료 및 방법: 23마리 토끼의 좌우 경골에 각각 2개씩 실험목적으로 제작한 RBM임플란트를 식립 후, 6주 후에 1차로 비틀림 제거력을 측정한 다음, 임플란트를 다시 재위치 침하시키고, 4일, 7일, 11일, 2주, 4주, 6주, 그리고 8주의 재침하시간 경과 후 2차로 비틀림 제거력을 측정하고 시편을 제작하여 조직 형태학적 검사를 하였다. 통계학적 검사를 위해 paired t-test를 시행했고, One-way ANOVA와 Tukey's post-hoc test 통해 그룹간 차이를 비교하여 다음과 같은 결과를 얻었다. 결과: 1차 비틀림 제거력과 비교해봤을 때 2차에서 11일 후에는 증가했으며, 2주 후부터 유의성 있게 증가하였다. 형광조사검사에서, 7일 후부터 골-임플란트 계면 사이에 형광밴드가 나타나는 광물화 현상이 관찰되고, 11일 후부터는 분명한 골 형성이 나타났다. 결론: 토끼에서는 11일 이후가 되면 충분한 재골유착을 얻을 수 있었다.