• 제목/요약/키워드: Bonding length

검색결과 268건 처리시간 0.031초

기판단위 밀봉 패키징을 위한 내압 동공열의 설계 및 강도 평가 (Design and Strength Evaluation of an Anodically Bonded Pressurized Cavity Array for Wafer-Level MEMS Packaging)

  • 강태구;조영호
    • 대한기계학회논문집A
    • /
    • 제25권1호
    • /
    • pp.11-15
    • /
    • 2001
  • We present the design and strength evaluation of an anodically bonded pressurized cavity array, based on the energy release rate measured from the anodically bonded plates of two dissimilar materials. From a theoretical analysis, a simple fracture mechanics model of the pressurized cavity array has been developed. The energy release rate (ERR) of the bonded cavity with an infinite bonding length has been derived in terms of cavity pressure, cavity size, bonding length, plate size and material properties. The ERR with a finite bonding length has been evaluated from the finite element analysis performed for varying cavity and plate sizes. It is found that, for an inter-cavity bonding length greater than the half of the cavity length, the bonding strength of cavity array approaches to that of the infinite plate. For a shorter bonding length, however, the bonding strength of the cavity array is monotonically decreased with the ratio of the bonding length to the cavity length. The critical ERR of 6.21J/㎡ has been measured from anodically bonded silicon-glass plates. A set of critical pressure curves has been generated for varying cavity array sizes, and a design method of the pressurized cavity array has been developed for the failure-free wafer-level packaging of MEMS devices.

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.

Nonlinear finite element analysis of effective CFRP bonding length and strain distribution along concrete-CFRP interface

  • Dogan, Ali Baran;Anil, Ozgur
    • Computers and Concrete
    • /
    • 제7권5호
    • /
    • pp.437-453
    • /
    • 2010
  • CFRP has been widely used for strengthening reinforced concrete members in last decade. The strain transfer mechanism from concrete face to CFRP is a key factor for rigidity, ductility, energy dissipation and failure modes of concrete members. For these reasons, determination of the effective CFRP bonding length is the most crucial step to achieve effective and economical strengthening. In this paper, generalizations are made on effective bonding length by increasing the amount of test data. For this purpose, ANSYS software is employed, and an experimentally verified nonlinear finite element model is prepared. Special contact elements are utilized along the concrete-CFRP strip interface for investigating stress distribution, load-displacement behavior, and effective bonding length. Then results are compared with the experimental results. The finite element model found consistent results with the experimental findings.

실장된 반도체 레이저의 본딩와이어를 고려한 광대역 변조 특성 해석 (Wideband modulation analysis of a packaged semiconductor laser in consideration of the bonding wire effect)

  • 윤상기;한영수;김상배;이해영
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.148-162
    • /
    • 1996
  • Bonding wires for high frequency device packaging have dominant parasitic inductances which limit the performance of semiconductor lasers. In this paper, the inductance sof bonding wires are claculated by the method of moments with incorporation of ohmic loss, and the wideband modulation characteristics are analyzed for ddifferent wire lengths and structures. We observed the modulation bandwidth for 1mm-length bonding wire lengths and structures. We observed the modulation bandwidth for 1mm-length bonding wire is 7 GHz wider than that for 2mm-length bonding wire. We also observed th estatic inductance calculation results in dispersive deviation of the parasitic inductance and the modulation characteristics from the wideband moment methods calculations. The angled bonding wire has much less parasitic inductance and improves the modulation bandwidth more than 6 GHz. This calculation resutls an be widely used for designing and packaging of high-speed semiconductor device.

  • PDF

Wire-bonding의 길이 변화에 따른 주파수별 특성 분석 (Analysis of Frequency Response Depending on Wire-bonding Length Variation)

  • 권은진;문종원;류종인;박세훈;김준철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.551-552
    • /
    • 2008
  • This paper presets a results of frequency response in variation of wire bonding length. A gold ball bonding is used as a wire bonding process, and a DPDT(double pole double thru) switch is adapted as a device for test. Wire length is ranged from 442um to 833um and a measured frequency range is from 1 GHz to 6 GHz. Little difference are measured in insertion loss and return loss depending on wire length. Measured S21 and S11 are -0.58 dB and -17.7 dB, respectively. S21 insertion loss is rising up and S11 insertion loss is falling down as the frequency is increased.

  • PDF

동결융해 및 부착재료 변화에 따른 GFRP-구조물 경계면의 최대 부착강도 및 유효부착길이 평가 (Investigation of Maximum Strength and Effective Bonding Length at the Interface Between Structure and GFRP Material Under Freeze-thaw Cycles and Applied Different Bonding Materials)

  • 최현규;정우영;안미경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.107-115
    • /
    • 2011
  • 본 연구는 부착재료의 변화 및 동결융해에 따른 FRP-콘크리트구조물 경계면의 거동을 조사하였다. 실험 시 고려된 연구변수로는 부착경계면의 부착강도, 경계면 유효부착길이 등을 조사하였다. 경계면 부착재료에 따른 거동변화 실험체의 경우 FRP-구조물 부착경계면에 사용되는 에폭시의 종류를 각각 3가지로 분류하며 FRP-콘크리트간 다양한 부착길이를 고려하여 시편을 제작하였으며 동결융해에 따른 경계면 거동조사의 경우 0 cycle에서 300cycle까지 계속적으로 증가되는 주기에 대하여 실험체들을 제작, 장기거동 부착실험을 수행하였다. 본 실험결과, 적용 부착재료의 종류에 따라 최대 유효부착길이는 5~7% 차이가 있었으며 동결융해 주기증가에 따른 최대부착하중 및 유효부착길이의 경우 초기에 나타난 급격한 거동변화 이후 상대적으로 불규칙한 변화를 장기적으로 나타내었다.

Effect of Mechanical Impact Treatment on Fiber Morphology and Handsheet Properties

  • Yung B. Seo;Kim, Dukki;Lee, Jong-Hoon;Yang Jeon
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2001년도 추계학술발표논문집
    • /
    • pp.183-199
    • /
    • 2001
  • Alternative way of shaping fibers suitable for papermaking was introduced. Impact refining, which was done simply by hitting wet fibers with a metal weight vertically, was intended to keep the fibers from shortening and to cause mostly internal fibrillation. Virgin chemical pulp, its recycled one and OCC were used in the experiment. It was noticed from the experiment that impact refining on virgin chemical pulp kept the fiber length and Increased bonding properties greatly, However, in the recycled fibers from the chemical pulp, fiber length and bonding properties were decreased. In OCC, which seems to contain fractions of semi-chemical pulp and mechanical pulp (GP), and which is recycled pulp from corrugated boxes, fiber length and bonding properties were decreased disastrously. We believe recycled cellulosic fibers (recycled chemical pulp and OCC in this case), which went through hornification, were less resistant to the mechanical impact than virgin chemical pulp. For virgin chemical pulp, impact refining allowed no significant fiber length shortening, high WRV, and high mechanical strength.

  • PDF

GFRP 보강근의 휨.부착특성에 관한 실험적 연구 (An Experimental Study for Flexural Bonding Characteristic of GFRP Rebar)

  • 심종성;오홍섭;주민관;강태성;김우중;이원홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.282-285
    • /
    • 2006
  • This study is to examine bond strength of beam reinforced with GFRP rebar under 4-point bending test by adopting BRITISH STANDARD. The variables were made to have bonding length of 5times$(5d_b)$, 10times$(10d_b)$ and 15times$(15d_b)$ of the nominal diameter of GFRP rebar and were done to analyze the relationship between the bonding strength and the slip. In the result of the test, pull-out failure was dominant in the $5d_b$ and $10d_b$ specimen, both patterns of the pull-out failure and concrete splitting failure appeared in the $10d_b$. On the other hand, the $15d_b$ specimen showed only concrete splitting failure at the end of bonding length. Therefore, it was prove that available bonding length of the GFRP rebar under bending condition on static test is over $15d_b$ then farther research such as fatigue bending test, development of bonding model, FEM parameter study should be performed.

  • PDF

동결융해 및 부착재료 변화에 따른 FRP-Concrete 경계면의 최대 부착강도 및 유효부착길이 평가 (Inverstigation of Maximum Strength and Effective Bonding Length at the Interface between Concrete and FRP Materials under Freeze-thaw Cycles and Applied Different Bonding Materials)

  • 김성훈;정우영;최현규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.435-436
    • /
    • 2010
  • 본 연구는 동결융해 및 부착재료의 변화에 따른 FRP-콘크리트 부착 경계면의 부착강도 및 유효부착길이의 변화를 조사하였으며, 본 연구 결과를 이용, 개선된 유효부착길이 관계식을 제안하였다.

  • PDF

차체접합과 관련한 접합 강도 평가 (Strength Evaluation of Adhesive Bonded Joint for Car Body)

  • 이강용;김종성;공병석;우형표
    • 한국자동차공학회논문집
    • /
    • 제6권1호
    • /
    • pp.143-150
    • /
    • 1998
  • The evaluation of joint fatigue strength of light weight materials for electrical vehicle body has been performed through single lap joint tests with the design parameters such as joint style, adherend, bonding overlap length and bonding thickness. Fatigue strength was evaluated through 5-Hz, tension-tension, load controlled test with the stress ratio zero value. It is experimentally observed that fatigue strength of joint increases for the increase of overlap length. The combinations of Al-Al and Al-FRP adherends show that fatigue strength of joint is hardly changed for the increase of bonding thickness, but FRP-FRP adherend specimen shows that fatigue strength of joint increases after decreases for the increase of bonding thickness. Al-Al adherend specimen has much higher fatigue length than Al-FRP and FRP-FRP adherend specimens. Riveting at adgesive bonded joint gives little effect on fatigue strength.