• 제목/요약/키워드: Bonding efficiency

검색결과 198건 처리시간 0.024초

Evaluating the bond strength between concrete substrate and repair mortars with full-factorial analysis

  • Felekoglu, Kamile Tosun;Felekoglu, Burcu;Tasan, A. Serdar;Felekoglu, Burak
    • Computers and Concrete
    • /
    • 제12권5호
    • /
    • pp.651-668
    • /
    • 2013
  • Concrete structures need repairing due to various reasons such as deteriorative effects, overloading, poor quality of workmanship and design failures. Cement based repair mortars are the most widely used solutions for concrete repair applications. Various factors may affect the bond strength between concrete substrate and repair mortars. In this paper, the effects of polymer additives, strength of the concrete substrate, surface roughness, surface wetness and aging on the bond between concrete substrate and repair mortar has been investigated. Full factorial experimental design is employed to investigate the main and interaction effects of these factors on the bond strength. Analysis of variance (ANOVA) under design of experiments (DOE) in Minitab 14 Statistical Software is used for the analysis. Results showed that the interaction bond strength is higher when the application surface is wet and strength of the concrete substrate is comparatively high. According to the results obtained from the analysis, the most effective repair mortar additive in terms of bonding efficiency was styrene butadiene rubber (SBR) within the investigated polymers and test conditions. This bonding ability improvement can be attributed to the self-flowing ability, high flexural strength and comparatively low air content of SBR modified repair mortars. On the other hand, styrene acrylate rubber (SAR) modified mortars was found incompatible with the concrete substrate.

인쇄기판형열교환기 핵심치수 구조설계 (Structural Design for Key Dimensions of Printed Circuit Heat Exchanger)

  • 김용완;강지호;사인진;김응선
    • 한국압력기기공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.24-31
    • /
    • 2018
  • The mechanical design procedure is studied for the PCHE(printed circuit heat exchanger) with electrochemical etched flow channels. The effective heat transfer plates of PCHE are assembled by diffusion bonding to make a module. PCHE is widely used for industrial applications due to its compactness, cost efficiency, and serviceability at high pressure and/or temperature conditions. The limitations and technical barriers of PCHE are investigated for application to nuclear components. Rules for design and fabrication of PCHE are specified in ASME Section VIII but not in ASME Section III of nuclear components. Therefore, the calculation procedure of key dimensions of PCHE is defined based on ASME section VIII. The effective heat transfer region of PCHE is defined by several key dimensions such as the flow channel radius, edge width, wall thickness, and ridge width. The mechanical design procedure of key dimensions was incorporated into a program for easy use in the PCHE design. The effect of assumptions used in the key dimension calculation on stress values is numerically investigated. A comparative analysis is done by comparing finite element analysis results for the semi-circular flow channels with the formula based sizing calculation assuming rectangular cross sections.

PHOTOPHYSICAL PROPERTIES OF FLUORENONES WITH CHIRAL SUBSTITUENTS AND THEIR ASYMMETRIC RECOGNITION THROUGH INTERMOLECULAR HYDROGEN BONDING INTERACTIONS IN THE EXCITED STATES

  • Aikawa, Yoshihide;Shimada, Tetsuya;Tachibana, Hiroshi;Inoue, Haruo
    • Journal of Photoscience
    • /
    • 제6권4호
    • /
    • pp.165-170
    • /
    • 1999
  • Asymmetric recognition of chiral alcohol by fluorenone derivatives with chiral substituents through intermolecular hydrogen bonding interaction in the singlet excited state was attempted. 1-((1S, 2R, 5S)-(+)-Menthyloxycarbonyl)aminofluoren-9-one (1-MAF) and 1-((1S, 2R, 5S)-(+)-menthyloxycarbonyl)oxyfluoren-9-one (1-MOF) were synthesized and their photophysical behaviors were characterized by the measurement of absorption and fluorescence spectra, as well as the quantum yield and the lifetime of fluorescence. The excited singlet states of 1-MAF and 1-MOF were revealed to have characteristics similar to those of fluorenone, though the intramolecular CT nature was fairly suppressed as compared with 3- and 4-substituted aminofluorenones. Fluorescences of 1-MAF and 1-MOF in acetonitrile were quenched by the addition of alcohols. Differences in fluorescence quenching efficiency were hardly observe for rather small chiral alcohols such as (R)-(-)- or (S)-(+)-2-butanol, while bulky alcohols such as menthol and isopinocampheol showed chiral recognition effects in their fluorescence quenching of 1-MAF in either acetonitrile or butyronitrile.

  • PDF

STS304와 Sl5C 이종마찰압접부의 접합계면 응력해석 (Stress Analysis of Bonding Interface in the Dissimilar Friction Welded Joints)

  • 오정국;차용순;성백섭;박창언;김하식;김충환
    • 한국공작기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.65-71
    • /
    • 2002
  • Friction welding has may merits such as energy efficiency, simple processing, etc. but it is difficult to obtain good welding at the welded interfaces and heat affected zone. It is discovered that stress singularity exists at the interferes and heat affected zone. The computer program based on boundary element method is utilized in this study. A mathematical model is implemented based on results from several experiments performed at and around the welded interfaces and heat affected zone of disimilar metals under static and dynamic loadings. This stay is to investigate the characteristics of the deformation and fracture behavior around interfaces for friction welded materials under static tensile load. Also, the stress distribution at the tip of crack is analyzed by using BU based on Kelvin's solution of 2-dimensional binding zone. The results of BEM are identical with those in case of considering interfaces of both heat affected zone. Also, stress singularity at the tip of interfaces appears when the elastic modulus ratio is 1.07.

탄소나노튜브 캐소드에서 표면처리 방법이 전계방출 특성에 미치는 영향 (Effects of Surface Treatment on Field Emission Properties for Carbon Nanotube Cathodes)

  • 성명석;오정섭;이지언;정승진;김태식;조영래
    • 한국재료학회지
    • /
    • 제16권1호
    • /
    • pp.37-43
    • /
    • 2006
  • Carbon nanotube cathodes (CNT cathodes) were fabricated by a screen printing method using multi-walled carbon nanotubes. The effects of surface treatment on CNT cathodes were investigated for use in high efficiency field emission displays. The optimum surface treatment for a CNT cathode is dependent on a relative bonding force of CNT films on the cathode after a heat treatment. Because of the high bonding force used in the Liquid method, this method is recommended for CNT cathodes which are heat-treated at $390^{\circ}C$ in a $N_2$ atmosphere. The Rolling method is applicable for CNT cathodes fabricated at $350^{\circ}C$ in an atmosphere of air. The results of this study provide basic criteria for the selection of an appropriate surface treatment for large area CNT cathodes.

금속지지체식 SOFC 제작 및 평가 (Fabrication and Evaluation of Metal-Supported SOFC)

  • 최진혁;이태희;최미화;유영성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권1호
    • /
    • pp.77-82
    • /
    • 2011
  • In this study, a metal-supported SOFC was fabricated using a relatively cheap and simple process. The adhesion process between ceramic cell and metal support was performed in high temperature over $1400^{\circ}C$ and the deformation of large metal-supported cell happened in this process. Using bi-layered metal support fabricated by diffusion bonding, the deformation of the metal-supported cell can be minimized and the sealing efficiency of anode and cathode was improved. The flatness of the cell was improved by over 20% and the maximum power density of over 0.5 $Wcm^{-2}$ was obtained at the operation condition of $800^{\circ}C$.

직관 마이크로채널 PCHE의 열전달특성 및 압력강하 (Heat Transfer Characteristics and Pressure Drop in Straight Microchannel of the Printed Circuit Heat Exchangers)

  • 김윤호;문정은;최영종;이규정
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.915-923
    • /
    • 2008
  • The performance experiments for a microchannel printed circuit heat exchanger (PCHE) of high-performance and high-efficiency on the two technologies of micro photo-etching and diffusion bonding were performed in this study. The microchannel PCHE were experimentally investigated for Reynolds number in ranges of 100 $\sim$ 700 under various flow conditions in the hot side and the cold side. The inlet temperatures of the hot side were conducted in range of $40^{\circ}C\;{\sim}\;50^{\circ}C$ while that of the cold-side were fixed at $20^{\circ}C$. In the flow pattern, the counter flow was provided 6.8% and 10 $\sim$ 15% higher average heat transfer rate and heat transfer performance than the parallel flow, respectively. The average heat transfer rate, heat transfer performance and pressure drop increases with increasing Reynolds number in all the experiment. The increasing of inlet temperature in the experiment range has not an effect on the heat transfer performance while the pressure drop decrease slightly with that of inlet temperature. The experimental correlations to the heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been suggested for the microchannel PCHE.

극저온 환경의 인쇄기판형 열교환기 열적성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of a Printed Circuit Heat Exchanger in a Cryogenic Environment)

  • 김동호;나상준;김영;최준석;윤석호
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.426-431
    • /
    • 2015
  • The advantages of a printed circuit heat exchanger (PCHE) are the compactness and efficiency derived from its heat-transfer characteristics; furthermore, a PCHE for which a diffusion bonding method was used during production can be applied to extreme environments such as a cryogenic condition. In this study, a micro-channel PCHE fabricated by diffusion bonding was investigated in a cryogenic environment regarding its thermal performance and the pressure drop. The test rig consists of an LN2 storage tank, vaporizers, heaters, and a cold box, whereby the vaporized cryogenic nitrogen flows in hot and cold streams. The overall heat-transfer coefficients were evaluated and compared with traditional correlations. Lastly, we suggested the modified heat-transfer correlations for a PCHE in a cryogenic condition.

와이어 본더용 Horn-Holder Assembly의 접촉 해석 (Contact Analysis on a Born-Holder Assembly for Wire Bonding)

  • 장창수;안근식;김영준;곽동옥;부성운
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.2008-2017
    • /
    • 2002
  • Joint structure of a transducer horn-holder assembly fur a wire bonder was examined through FEM contact analysis. A three dimensional modeling and analysis was carried out to survey the internal physics of this structure and to prove the accuracy of a computation compared to a measurement. After validation, a simple two dimensional model was built fur various parametric study considering the efficiency and speed of the computation. Several factors such as boundary conditions, a modeling boundary, mesh density and so on, were considered to obtain consistency with three dimensional analysis. An arc angle and a position of each holder boss were chosen as design parameters. A design of experiment was applied to find out an optimized design of the holder geometry. As a result, a guideline for holder boss design was suggested and main factors and their influence on stress concentration in the transducer horn were surveyed.

리브 형상을 갖는 반단면 프리캐스트 판넬의 휨 안전성 평가 연구 (Study on Safety Evaluation of the Half-Depth Precast Deck with RC Rib Pannel for the Flexural Behavior)

  • 황훈희
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.76-84
    • /
    • 2019
  • The precast pannels are used as formwork in Half-depth precast deck systems. Therefore, it has many advantages, including safe and convenient construction and reduced construction period compared to cast-in-place construction method. In half-depth precast deck systems, the bonding of precast pannels to cast-in place concrete is very important. To enhance the performance of half-depth precast deck system, it is necessary to improve the composite efficiency of the interface or increase the stiffness of the precast pannel to reduce deformation or stress on the interface. In this study, a flexural test of half-depth precast deck system was performed, in which the shear connecting reinforcement was applied to increase the bonding performance at the interface, and the rib shape precast panels were applied to improve stiffness. In addition, the safety and serviceability of these systems were evaluated. Test results show that all of specimens have the required flexural strength under the ultimate strength limit design. It was also evaluated to have sufficient safety for the serviceability of deflection and crack under the serviceability limit design.