• 제목/요약/키워드: Bonded Tendon

검색결과 58건 처리시간 0.046초

외부 비부착 강선을 가진 부재의 극한 강선응력 평가 (Evaluation of Ultimate Tendon Stress in Prestressed Concrete Members with External Unbonded Tendons)

  • 오병환;유성원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.381-386
    • /
    • 1999
  • The member with external unbonded tendon has two remarkable characteristics, i.e., eccentricity variation and slip by friction force at deviators, compared with internal bonded or unbonded member. An efficient numerical procedure for the nonlinear analysis of prestressed concrete beam with external unbonded tendon considering two remarkable characteristics is formulated and corresponding computer code is developed. On the basis of statistical process of parametric study results, strain compatibility method, eccentricity variation predictor and tendon stress predictor at ultimate state are proposed and verified with test results and existing Codes, which can evaluate flexural behavior at ultimate state. Finally, the proposed procedure and predictors can be efficiently used for the realistic and accurate analysis of prestressed concrete members with external unbonded tendons.

  • PDF

비부착 PSC 보에서 슬립이 없는 강선의 극한 응력 예측에 관한 연구 (A Study on the Prediction of Ultimate Stress of Tendon in Unbonded Prestressed Concrete Beams without Slip)

  • 홍성수;유성원;박승범
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.537-548
    • /
    • 2008
  • 최근 들어 비부착 강선을 이용한 프리스트레스트 콘크리트 구조물의 건설이 증가하고 있다. 그러나 극한거동 해석 시 단면 적합조건을 이용하는 내부 부착 강선과는 다르게 비부착 강선은 부재의 전체거동에 의해서 응력 증가량이 결정된다. 또한 외부 강선의 경우에는 편향부에서의 미끌림 효과와 강선의 편심 변화 효과 등이 발생하게 된다. 따라서 본 연구는 비부착 강선을 가지는 프리스트레스트 콘크리트(PSC) 보의 거동 특성을 평가하고 비부착 강선의 극한 응력을 구하기 위하여 지간길이/유효깊이, 콘크리트 압축강도, 철근비 및 기존 부착강선의 영향 등을 변수로 하여 정적 휨실험을 수행하여 비부착 강선 부재의 휨거동 특성을 얻었다. 실험결과에 의하면 균열하중, 철근 항복 하중 및 파괴하중의 경우, 콘크리트 강도보다는 철근비의 영향이 더 크게 나타났으며, 강도 측면에서는 고강도의 경우가 저강도의 경우보다 약간은 구조 성능이 우수하나, 큰 차이는 없는 것으로 나타났다. 또한 L/dp 값이 커질수록 훨씬 더 긴 구간의 연성 거동이 있는 것으로 나타났다. 이는 철근 항복 이후 비부착 강선의 기여가 상당히 크다는 것을 알 수 있었으며, ACI-318에서 제시하고 있는 비부착 강선의 극한 응력식은 실험 결과와 잘 일치하지 않으며, 경향성도 없는 것으로 나타났다. 실험결과 들을 분석하여 미끌림 현상이 없는 비부착 강선의 극한응력에 대한 예측식을 제안하였다. 제안된 예측식은 실험결과와 비교적 잘 일치하는 것으로 나타났으며, 미끌림 현상이 없는 비부착 강선의 극한 휨거동 평가, PSC 부재 해석 및 설계 시 본 연구에서 제안된 식은 유용한 기초가 될 것으로 사료된다.

A SENSITIVITY ANALYSIS OF THE KEY PARAMETERS FOR THE PREDICTION OF THE PRESTRESS FORCE ON BONDED TENDONS

  • Jang, Jung-Bum;Lee, Hong-Pyo;Hwang, Kyeong-Min;Song, Young-Chul
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.319-328
    • /
    • 2010
  • Bonded tendons have been used in reactor buildings at some operating nuclear power plants in Korea. Assessing prestress force on these bonded tendons has become an important pending problem in efforts to assure continued operation beyond their design life. The System Identification (SI) technique was thus developed to improve upon the existing indirect assessment technique for bonded tendons. As a first step, this study analyzed the sensitivity of the key parameters to prestress force, and then determined the optimal parameters for the SI technique. A total of six scaled post-tensioned concrete beams with bonded tendons were manufactured. In order to investigate the correlation of the natural frequency and the displacement to prestress force, an impact test, a Single Input Multiple Output (SIMO) sine sweep test, and a bending test using an optical fiber sensor and compact displacement transducer were carried out. These tests found that both the natural frequency and the displacement show a good correlation with prestress force and that both parameters are available for the SI technique to predict prestress force. However, displacements by the optical fiber sensor and compact displacement transducer were shown to be more sensitive than the natural frequency to prestress force. Such displacements are more useful than the natural frequency as an input parameter for the SI technique.

포스트텐션된 3연속 스팬 슬래브의 실험연구 (Experimental Study on Post-tensioned 3-Continuous Span Slabs)

  • 임재형;문정호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.668-673
    • /
    • 1998
  • The specimen of current study has the same type with the 3-span slabs of Burns et al used in the study by Mojtahedi/Gamble, which laid a ground for the revision of the ACI318-77 code to the ACI 318-83 code. But those specimens was failed prematurely before it reached the ultimate strength which the specimen had. The reason is that bonded reinforcements were cut off where there is no need for the flexural reinforcement. As results. the slabs failed ultimately where the reinforcements was cut off. Thus, the tendon stresses of failure may have been much smaller than the values which culd reach if the bonded reinforcements were extended beyond the theoretical cut off points. On the based on the fact mentioned above. the specimens which had the same conditions as the specimens of Burns et al were used in the current study, but in which the reinforcements were distributed in a sequence for the reinforcements not to be cut anywhere in the 3-span. As a results, it was known that the current ACI code, revised by the result of Mojtahedi/Gamble's study, overestimated the effect of span/depth ratio on the members with high span/depth ratio. Thus it was concluded that the effect of span/depth ratio on the ultimate stress of unbonded tendon regulated by the current ACI code must be reconsidered and reevaluated.

  • PDF

A strain-based wire breakage identification algorithm for unbonded PT tendons

  • Abdullah, A.B.M.;Rice, Jennifer A.;Hamilton, H.R.
    • Smart Structures and Systems
    • /
    • 제16권3호
    • /
    • pp.415-433
    • /
    • 2015
  • Tendon failures in bonded post-tensioned bridges over the last two decades have motivated ongoing investigations on various aspects of unbonded tendons and their monitoring methods. Recent research shows that change of strain distribution in anchor heads can be useful in detecting wire breakage in unbonded construction. Based on this strain variation, this paper develops a damage detection model that enables an automated tendon monitoring system to identify and locate wire breaks. The first part of this paper presents an experimental program conducted to study the strain variation in anchor heads by generating wire breaks using a mechanical device. The program comprised three sets of tests with fully populated 19-strand anchor head and evaluated the levels of strain variation with number of wire breaks in different strands. The sensitivity of strain variation with wire breaks in circumferential and radial directions of anchor head in addition to the axial direction (parallel to the strand) were investigated and the measured axial strains were found to be the most sensitive. The second part of the paper focuses on formulating the wire breakage detection framework. A finite element model of the anchorage assembly was created to demonstrate the algorithm as well as to investigate the asymmetric strain distribution observed in experimental results. In addition, as almost inevitably encountered during tendon stressing, the effects of differential wedge seating on the proposed model have been analyzed. A sensitivity analysis has been performed at the end to assess the robustness of the model with random measurement errors.

프리캐스트 세그먼트 PSC 교각의 성능평가를 위한 지진해석 (Seismic Analysis for Performance Assessment of Precast Segmental PSC Bridge Columns)

  • 김태훈;박세진;김영진;신현목
    • 한국지진공학회논문집
    • /
    • 제13권2호
    • /
    • pp.15-27
    • /
    • 2009
  • 이 연구는 지진하중을 받는 프리캐스트 세그먼트 PSC 교각의 지진거동을 파악하는데 그 목적이 있다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology)이다. 사용된 부착 또는 비부착 텐던요소는 유한요소법에 근거하며 프리스트레스트 콘크리트 부재의 콘크리트와 텐던의 상호작용을 구현할 수 있다. 그리고 수정된 접합요소는 세그먼트 접합부의 비탄성거동을 예측할 수 있다. 동적 평형방정식의 해는 HHT(Hilber-Hughes-Taylor) 법에 의한 수치적분으로 구하였다. 제안된 해석기법은 수치예제에 대하여 입력지진파에 따른 지진거동을 비교적 정확하게 예측하였다.

원자로 격납건물의 3차원 구조해석시스템 (Three-Dimensional Structural Analysis System for Nuclear Containment Building)

  • 김선훈
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.235-243
    • /
    • 2010
  • 본 논문에서는 원자로 격납건물의 3차원 해석을 수행할 수 있는 구조해석 시스템을 구축하여 제시하였다. 구조해석 시스템은 고성능 평판 및 쉘 유한요소를 요소 라이브러리로 추가하였고, 비부착식 텐던과 부착식 텐던의 거동을 정확하게 모사할 수 있는 모델링방법을 포함하고 있다. 이러한 기능을 프로그래밍하고 범용 구조해석프로그램 DIANA에 접목시켜 원자로 격납건물의 비선형해석은 물론이고 내압능력 평가가 가능하다. 본 논문에서 제안한 3차원 구조해석 시스템의 신뢰성을 확인하기 위해 중수로형 원자로 격납건물의 구조해석을 수행하여 다른 기관에서 수행한 축대칭 구조해석 결과와 비교분석하였다.

원전 부착식 텐던 격납건물의 구조거동 분석기법 개발 I-CANDU형 (Development of Analysis Technique for Structural Behavior of Containment with Bonded-Type Tendons (CANDU Type))

  • 이상근;박상순;이상민;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.643-646
    • /
    • 2004
  • The posttensioning system of nuclear containment have to be verified its structural integrity by the periodic inspection because the structural behavior of the containment is changed by the variation of the physical property of concrete and tendon as time passes. In this study a program 'SAPONC-CANDU' which is able to monitor and analysis the micro structural behavior of the domestic CANDU type containment at all times was developed. The readings of vibrating-wire strain gauges embedded into the concrete of containment were used as input data for operating the program. This program provides the long-term prediction values and bands of the concrete strain due to the time dependent factors of the concrete and tendon of the domestic CANDU type containment.

  • PDF

Performance assessment of precast concrete pier cap system

  • Kim, T.H.;Kim, Y.J.;Shin, H.M.
    • Computers and Concrete
    • /
    • 제13권4호
    • /
    • pp.501-516
    • /
    • 2014
  • The purpose of this study was to investigate the performance of precast concrete pier cap system. The proposed precast pier cap provides an alternative to current cast-in-place systems, particularly for projects in which a reduced construction time is desired. Five large-scale pier cap specimens were constructed and tested under quasistatic monotonic loading. The computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology) was used for the analysis of reinforced concrete structures. A bonded tendon element is used based on the finite element method, and can represent the interaction between the tendon and concrete of a prestressed concrete member. A joint element is used in order to predict the inelastic behaviors of segmental joints with a shear key. This study documents the testing of the precast concrete pier cap system under monotonic loading and presents conclusions and design recommendations based on the experimental and analytical findings. Additional full-scale experimental research is needed to refine and confirm design details, especially for actual detailing employed in the field.