• Title/Summary/Keyword: Bond Coating

Search Result 310, Processing Time 0.028 seconds

Crystalline Phases and Superconductor Characteristics of the Plasma Sprayed YBa2Cu$\chi$O7-y High Tc Superconductor Thick Film (플라즈마 용사법에 의해 제조된 YBa2Cu$\chi$O7-y(X=3, 3.5, 4) 고온초전도체 후막층의 결정상 및 초전도 특성)

  • 한명섭;서동수
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.2
    • /
    • pp.152-160
    • /
    • 1992
  • High-Tc superconductor thick films of YBa2Cu$\chi$O7-y (X=3, 3.5, 4) of which thickness varies from 100 $\mu\textrm{m}$ to 200 $\mu\textrm{m}$ were successfully prepared by plasma spraying method, and the characteristics of thick film depending on copper content and heat treatment conditions were investigated. Regardless of heat-treated temperature, the specimens with X=3 were composed of YBa2Cu$\chi$O7-y, Y2BaCuO5 and BaCuO3 phases. The specimens with X=4, however, were composed of YBa2Cu$\chi$O7-y phase at all heat treatment conditions. The specimens with X=4 composition showed the best superconducting characteristics after heat treatment at 925$^{\circ}C$, and the superconducting transition temperature with zero resistivity (Tc,zero) was 87K. The thick film lost superconductivity when the specimens were heat-treated at 950$^{\circ}C$ because of interdiffusion between superconductor elements and bond coating elements and Y2BaCuO5 phase was found was found to be main phase at the interface.

  • PDF

Influence of some additives on the process of Ni-W alloy electroplating

  • Wu, Yi-Yong;Kim, Dong-Soo;Chang, Do-Yon;Kwon, Sik-Chol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.56-56
    • /
    • 2001
  • Ni-W alloy deposit is one of the best alternatives to hard chromium plating because of its good mechanical properties (high hardness, high strength, and good wear resistance). Ni-W alloy is deposited from weakly acidic or alkaline electrolytic bath with nickel sulfate, sodium tungstate or APT, and some kinds of organic hydroxy-acid complex and ammonia salts. W content of the deposit can be changed from 0 to 5Owt% and the coating with high W content is more attracted. But, meanwhile, the deposited layers are always found high internal stress, which cause them to become brittle and to bond insufficiently with the substrate. On the second hand, as the W content is incresed, the current efficiency reduced, which results in large quantities of hydrogen evolution and then produces bubbles on surface and pitting appearance In this paper, the influence of some additives on Ni-W alloy electroplating was investigated by means of compositional analysis and SEM. The initial results showed that 2-butyne-1,4-diol was the best brightener for Ni-W plating process. It could brighten and level deposit, but decreased the cathodic current efficiency. Its optimum concentration range is from O.lgjL to 0.5gjL. Besides, three kinds of additives including 2-butyne-1,4-diol were examined with Dagguchi method.

  • PDF

The hardness property for the contents of hydrogen of DLC coating deposited by PECVD (PECVD를 이용하여 증착시킨 DLC 코팅의 수소함유량에 의한 경도 특성)

  • Kim, Jun-Hyeong;Mun, Gyeong-Il;Park, Jong-Wan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.141-141
    • /
    • 2011
  • DLC(Diamond Like Carbon) 박막은 높은 경도, 낮은 마찰계수, 내화학성 등의 우수한 트라이볼로지적 특성을 가지고 있기 때문에 다양한 산업분야에서 적용되고 있다. 이러한 DLC 박막은 합성기구나 구조의 관점에서 몇 가지 다른 이름으로 불려지기도 한다. 밀도와 경도가 높기 때문에 경질탄소(Hard Carbon)라고도 불려지며, 수소를 함유한 경우에는 수소함유 비정질 탄소(Hydrogenated Amorphous Carbon)이라는 이름이 사용되며, 고밀도 탄소(Dense Carbon) 또는 고밀도 탄화수소(Dense Hydrocarbon)라고 불리기도 한다. 이렇듯 DLC 박막은 합성방법에 따라 함유된 수소와 탄소의 결합구조의 차이가 있다. 수소 함유한 DLC 박막은 20~50%까지 수소를 함유하며, DLC막의 기계적, 광학적, 전기적 특성들이 수소함량과 밀접한 관계를 가지고 있는 것으로 알려져 있다. 그러나 함유된 수소가 $300^{\circ}C$ 이상의 온도에서는 쉽게 결합에서 이탈되면서 흑연화와 더불어 마찰마모시 코팅층의 파손이 발생한다고 보고되고 있고, 또한 수소량이 증가함에 따라 DLC 박막의 경도는 감소하게 되는데, 이는 수소에 의해 dangling bond가 Passivation되면 탄화수소의 3차원적인 Crosslinking은 그만큼 감소하게 되기 때문이라고 알려져 있다. 본 연구에서는 PECVD를 이용하여 여러 가지 공정에 따른 DLC 박막을 증착시켰으며, 수소함유량에 따른 DLC막의 구조와 그에 따른 경도 변화를 살펴보았다. FTIR(Furier Transform Infrared Spectroscopy)과 Raman Spectroscopy을 이용하여 DLC막의 수소의 결합상태를 관찰하였으며, Nano Indentation을 사용하여 미소경도를 측정하였고, FE-SEM을 이용하여 표면과 단면을 관찰하였다. 막의 두께 측정에는 ${\alpha}$-Step을 사용하였으며, Ball-on-Disk 타입의 Tribo-meter을 이용하여, 모재의 경도에 따른 마찰계수 변화를 관찰하였다.

  • PDF

Chitosan, PVA, 그리고 Chitosan/PVA 피막의 특성과 사과 겹무늬썩음병균 Botryosphaeria dothidea의 포자분산 억제작용

  • Lee, Seung-Ji;Park, Dong-Chan;Kim, Eve;Uhm, Jae-Youl;Lee, Yong-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.5
    • /
    • pp.546-552
    • /
    • 1996
  • The applicability of chitosan, a biodegradable natural polymer, as the coating material to prevent the dispersal of the spores of the apple white rot agent Botryosphaeria dothidea, was investigated. The physical properties of mixed chitosan/polyvinyl alcohol(PVA) film showed the increased physical properties for film formation, such as tensil strength, elongation, and viscosity, compared to either chitosan or PVA film. The FT-IR spectra of chitosan/PVA film indicated that the film was formed by simple blending not by any new synthetic bond. The chitosan and chitosan/PVA film showed effective antifungal activity on B. dothidea. The formed films were well decomposed by ASTM strains used for biodegradability test, on the other hand, the PVA film could not be decomposed by above standard strains. The field test at apple orchard showed that the dispersal of B. dothidea spores could be effectively reduced by coated film, especially by chitosan/PVA film. The spore dispersal was reduced upto 97.0% by 1.0% chitosan/5.0% PVA film during 4 months.

  • PDF

Thermal Fatigue Behavior of Thermal Barrier Coatings by Air Plasma Spray (대기플라즈마 용사법으로 제조된 열차폐코팅의 열피로특성 평가)

  • Lee, Han-sang;Kim, Eui-hyun;Lee, Jung-hyuk
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.6
    • /
    • pp.363-369
    • /
    • 2008
  • Effects of top coat morphology and thickness on thermal fatigue behavior of thermal barrier coatings (TBC) were investigated in this study. Thermal fatigue tests were conducted on three coating specimens with different top coat morphology and thickness, and then the test data were compared via microstructures, cycles to failure, and fracture surfaces. In the air plasma spray specimens (APS1, APS2), top coat were 200 and $300{\mu}m$ respectively. The thickness of top coat was about $700{\mu}m$ in the perpendicular cracked specimen (PCS). Under thermal fatigue condition at $1,100^{\circ}C$, the cycles to top coat failure of APS1, APS2, and PCS were 350, 560 and 480 cycles, respectively. The cracks were initiated at the interface of top coat and thermally grown oxide (TGO) and propagated into TGO or top coat as the number of thermal fatigue cycles increased. For the PCS specimen, additive cracks were initiated and propagated at the starting points of perpendicular cracks in the top coat. Also, the thickness of TGO and the decrease of aluminium concentration in bond coat do not affect the cycles to failure.

An Experimental Study and Value Analysis for Performance Assessment of the Embo-thane Membrane Waterproofing Method (엘보탄도막방수공법의 성능평가를 위한실험적 연구 및 VE분석)

  • Yoon, Cha-Woong;Lee, Seung-Soo;Kim, Sang-Rok;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.123-134
    • /
    • 2009
  • Since 1970s, urethane waterproofing method is broadly used in rooftops, underground spaces, and sports stadium for its outstanding ultraviolet blockage, watertightness, and elasticity. However, development of slippage-resistance and endurance, improvement of function considering convenience and visually pleasing of users, urethane waterproofing method is necessary, since rooftops and underground spaces have slippage and external force risks. Therefore, many improved waterproofing methods are being developed and, recently, embo-thane waterproofing method, which applies embo-spray coating system, has been developed. This paper explains exposure, nonexposure, and floor-material of embo-thane waterproofing method, and then perform experimental study for comparison with urethane waterproofing method about tensile strength, coefficient of expansion, performance of bond, anti-abrasion, and slippage-resistance. In addition, the performance index was presented for the superiority of embo-thane waterproofing method compared to urethane by setting up evaluation criteria considering not only physical performance but also design side of embo-thane waterproofing method, and Value Analysis applying AHP. Also for an assessment considering uncertain result, Monte Carlo Simulation Method was used to operate reliability analysis through statistic approach method.

Convergence study of mechanical properties and biocompatability of Ti Gr4 surface coated with HA using plasma spray for ossoeintegration (골융합 촉진을 위한 Ti Gr4의 HA 코팅에 대한 물리적 특성과 생체안정성에 대한 융합적 연구)

  • Hwang, Gab-Woon
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.145-151
    • /
    • 2021
  • This study aimed to investigate the efficient conduct of HA coating on Ti Gr4 for the practical use of medical device. Ti Gr4 alloy specimens measuring 𝜱 25mm × 1mm were sprayed with hydroxyapatite using thermal spray according to ASTM F1185-88. The surface was evaluated at #120, #400, #1,000 sandpaper and barrel finishing. Each coating properties was analyzed using SEM, UTS 20,000psi cap. and in vitro cytotoxicity. Surface morphology consists of well molten particles with very little resolidified or unmolten areas. The average Ca/P ratio is 1.74 which is in good agreement with theoretical value of 1.67. The average roughness Ra is very representative of roughness of specimen. The coatings are dense and well adhered to the substrate. The average bond strength was 61.74 MPa with a standard deviation of 4.06 which indicates fairly reliable results for ASTM 633 type tests. Variations in results from jig design, epoxy used, crosshead speeds etc. in vitro cytotoxicity result had a Grade 3. The results of the study are expected to be helpful in osseointegration and plasma-spray HA coated Ti Gr4 are more satisfactory in HA coating thickness elevation which is preferable to any other system.

Bond Characteristics of Scale According to the Drainage Pipe's Material in Tunnel (터널 배수공의 재질에 따른 스케일 부착 특성에 관한 연구)

  • Chu, Ickchan;Nam, Seunghyuk;Baek, Seungin;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.51-57
    • /
    • 2011
  • The calcium hydroxide($Ca(OH)_{2}$) which is flowed into the deteriorated tunnel by groundwater is reacted with carbon dioxide($CO_{2}$) and the vehicle's exhaust gas ($SO_{3}$). So its by-products are precipitated at the drainage pipe and these cause the drainage clogging. Most by-products are composed of $CaCO_{3}$ with calcite from a chemical experiment. The purpose of this study is mainly focused on comparison of attachment on each material of drainage pipe (teflon-coated steel pipe, silicon-Oil coated pipe, acrylic pipe and PVC pipe). The test was progressed to disembogue the CaO aqueous solution and tunnel outflow into each of the pipes. The experimental results show that the most produced scale pipe is PVC material and the followings are Acrylic pipe, Silicon-Oil coating pipe and Teflon coating pipe. But the long-term test results showed that teflon-coated steel pipe had a problem with durability because soil which was contained in the tunnel outflow occurred detachment of coating and corrosion of the steel pipe.

Effect of RGD peptide coating of implant titanium surface on human mesenchymal stem cell response (양극산화 티타늄 표면에 서로 다른 RGD 펩타이드 코팅 방법이 인간간엽줄기세포 반응에 미치는 영향)

  • Kim, Min-Su;Jeong, Chang-Mo;Jeon, Young-Chan;Ryu, Jae-Jun;Huh, Jung-Bo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.245-253
    • /
    • 2011
  • Purpose: The aim of this in vitro study was to estimate surface characteristic after peptide coating and investigate biological response of human mesenchymal stem cell to anodized titanium discs coated with RGD peptide by physical adhesion and chemical fixation. Materials and methods: Fluorescence isothiocyanate (FITC) modified RGD-peptide was coated on the anodized titanium discs (diameter 12 mm, height 3 mm) using two methods. One was physical adhesion method and the other was chemical fixation method. Physical adhesion was performed by dip and dry procedure, chemical fixation was performed by covalent bond via silanization. In this study, human mesenchymal stem cell was used for experiments. The experiments consisted of surface characteristic evaluation after peptide coating, analysis about cell adhesion, proliferation, differentiation, and mineralization. Obtained data are statistically treated using Kruskal-Wallis test and Bonferroni test was performed as post hoc test (P=.05). Results: The evaluation of FE-SEM images revealed no diffenrence at micro-surfaces between each groups. Total coating dose was higher at physical adhesion experimental group than at chemical fixation experimental group. In cell adhesion and proliferation, RGD peptide coating did not show a statistical significance compared with control group (P>.05). In cell differentiation and mineralization, physical adhesion method displayed significantly increased levels compared with control group and chemical fixation method (P<.05). Conclusion: RGD peptide coating seems to enhance osseointegration by effects on the response of human mesenchymal stem cell. Especially physical adhesion method showed more effective than chemical fixation method on response of human mesenchymal stem cell.

The Effect of Surface Treatment on the Shear Bond Strength of Resin Cement to Zirconia Ceramics (표면처리가 지르코니아와 레진 시멘트의 전단결합강도에 미치는 효과)

  • Jung, Seung-Hyun;Kim, Kye-Soon;Lee, Jae-In;Lee, Jin-Han;Kim, Yu-Lee;Cho, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.83-94
    • /
    • 2009
  • The aim of this study was to investigate the shear bond strength between zirconia ceramic and resin cement according to various surface treatments. The surface of each zirconia ceramic was subjected to one of the following treatments and then bonded Rely X Unicem or Rely X ARC resin cement; (1) Rocatec system and $50{\mu}m$ surface polishing, (2) No treatment and $50{\mu}m$ surface polishing, (3) Rocatec system and $1{\mu}m$ surface polishing, (4) No treatment and $1{\mu}m$ surface polishing. Each of eight bonding group was tested in shear bond strengths by universal testing machine(Z020, Zwick, Ulm, Germany) with crosshead speed of 1mm/min. The results were as follows; 1. Rocatec treatment groups showed greater bonding strengths than No Rocatec groups. There was significant difference of among groups(P<0.001) 2. For Rocatec groups, $50{\mu}m$ surface roughness groups showed greater bonding strengths than $1{\mu}m$ surface roughness groups.(P<0.001) But for No Rocatec groups, There was no significant difference of among groups(P>0.05) 3. Rely X Unicem groups showed greater bonding strengths than Rely X ARC groups. There was significant difference of among groups(P<0.01) Within the conditions of this study, Rocatec treatment was an effective way of increasing zirconia bonds to a resin cement, even in the case of self-adhesive resin cement.