• Title/Summary/Keyword: Bolt Strength Analysis

Search Result 139, Processing Time 0.031 seconds

Strength and stiffness of cold-formed steel portal frame joints using quasi-static finite element analysis

  • Mohammadjani, Chia;Yousefi, Amir M.;Cai, Shu Qing;Clifton, G. Charles;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.25 no.6
    • /
    • pp.727-734
    • /
    • 2017
  • This paper describes a quasi-static finite element analysis, which uses the explicit integration method, of the apex joint of a cold-formed steel portal frame. Such cold-formed steel joints are semi-rigid as a result of bolt-hole elongation. Furthermore, the channel-sections that are being connected have a reduced moment capacity as a result of a bimoment. In the finite element model described, the bolt-holes and bolt shanks are all physically modelled, with contact defined between them. The force-displacement curves obtained from the quasi-static analysis are shown to be similar to those of the experimental test results, both in terms of stiffness as well as failure load. It is demonstrated that quasi-static finite element analysis can be used to predict the behavior of cold-formed steel portal frame joints and overcome convergence issues experienced in static finite element analysis.

Estimation on clamping load of high strength bolts considering various environment conditions

  • Nah, Hwan-Seon;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.399-408
    • /
    • 2017
  • Of high strength bolts, the torque shear type bolt is known to be clamped normally when pin-tails are broken. Sometimes the clamping loads on slip critical connections considerably fluctuate from the required tension due to variation of torque coefficient. This is why the viscosity of lubricant affects the torque coefficient by temperature. In this study, the clamping tests of high strength bolts were performed independently at laboratory conditions and at outdoor environment. The temperatures of outdoor environment candidates were ranged from $-11^{\circ}C$ to $34^{\circ}C$ for six years. The temperature at laboratory condition was composed from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. At outdoor environment conditions, the clamping load of high strength bolt was varied from 159 to 210 kN and the torque value was varied from 405 to 556 Nm. The torque coefficients at outdoor environment were calculated from 0.126 to 0.158 when tensions were measured from 179 to 192 kN by using tension meter. The torque coefficients at outdoor environment conditions were analyzed as the range from 0.118 to 0.152. From these tests, the diverse equations of torque coefficient, tension dependent to temperature can be acquired by statistic regressive analysis. The variable of torque coefficient at laboratory conditions is 0.13% per each $1^{\circ}C$ when it reaches 2.73% per each $1^{\circ}C$ at outdoor environment conditions. When the results at laboratory conditions and at outdoor environment were combined to get the revised equations, the change in torque coefficient was modified as 0.2% per each $1^{\circ}C$ and the increment of tension was adjusted as 1.89 % per each $1^{\circ}C$.

A Structural Analysis and Safety Evaluation of a Loose-proof Lock-Nut Structure (풀림방지 로크너트의 구조해석 및 안전성 평가)

  • Park, Sang Kun
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.2
    • /
    • pp.20-24
    • /
    • 2012
  • In this paper, we perform a ANSYS simulation of assembly structure composed of three parts, bolt, nut, and coil spring, under the loading of a screw torque 640~800 ($N{\cdot}m$) derived from the given bolt tensile strength 10.9, which allows us to investigate a lock-nut mechanism for the prevention of bolt-loosening after three parts are fastened. And also we investigate the safety factor of each component with effective stress distribution obtained from the simulation, which enables us to estimate the structural safety of a new lock-nut structure. Both simulation and investigation shown in this paper will contribute to the development of a new lock nut structure.

  • PDF

Design and static structural analysis of KSLV-I upper stage cowls (KSLV-I 상단부 카울 설계 및 구조 해석)

  • An, Jae-Mo;Kim, Kwang-Soo;Jang, Young-Soon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.111-118
    • /
    • 2007
  • KSLV-I which is being developed in KARI is composed with two stages, and adaptor ring is used for coupling stage. Cables for interconnecting between stage is exposed on the outside. Also 8 pyro bolts which are installed in adaptor ring are used for separation of stage. In general, cowl is used for protecting exposed parts or structure which are anxious about damage from outer environment. In KSLV-I, two kind of cowls are designed. The one is umbilical cowl, and the other is pyro bolt cowl. Because cowl is exposed on the outside, heat and pressure load developed from air have effect on cowls. Therefore verification of structural strength through static analysis is required. In this study, static analysis in load condition except heat load is accomplished. In result of analysis, structural strength of pyro bolt cowl is verified. But breakage of umbilical cowl is confirmed in pressure load condition. So design of umbilical cowl is modified for satisfying required structural strength. And structural strength of umbilical cowl through analysis is verified.

  • PDF

Performance Analysis of DiffServ Networks for Providing (QoS 제공을 위한 차등서비스 망 성능분석)

  • Lim, Seog-Ku
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.448-451
    • /
    • 2006
  • Currently the bolt joint defect occurs from the steel bridge which is in the process of using but that investigation about each kind defect is lacking state. Research to see consequently the high strength bolt joint sliding conduct bring the model it used a structural analysis program LUSAS numerical analysis execution and a plan for Steel Box Girder Bridge copying full-size H-Beam and plan pretensioned bolt force 100%. 75%, 50% and 25% pretensioned force it acted in standard. And a hold an examination, against the sliding loads which it follows in the pretensioned force it will analysis.

  • PDF

A Parametric Study of Ridge-cut Explosive Bolts using Hydrocodes

  • Lee, Juho;Han, Jae-Hung;Lee, YeungJo;Lee, Hyoungjin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.1
    • /
    • pp.50-63
    • /
    • 2015
  • Explosive bolts are one of pyrotechnic release devices, which are highly reliable and efficient for a built-in release. Among them, ridge-cut explosive bolts which utilize shock wave generated by detonation to separate bolt body produce minimal fragments, little swelling and clean breaks. In this study, separation phenomena of ridge-cut explosive bolts or ridge-cut mechanism are computationally analyzed using Hydrocodes. To analyze separation mechanism of ridge-cut explosive bolts, fluid-structure interactions with complex material modeling are essential. For modeling of high explosives (RDX and PETN), Euler elements with Jones-Wilkins-Lee E.O.S. are utilized. For Lagrange elements of bolt body structures, shock E.O.S., Johnson-Cook strength model, and principal stress failure criteria are used. From the computational analysis of the author's explosive bolt model, computational analysis framework is verified and perfected with tuned failure criteria. Practical design improvements are also suggested based on a parametric study. Some design parameters, such as explosive weights, ridge angle, and ridge position, are chosen that might affect the separation reliability; and analysis is carried out for several designs. The results of this study provide useful information to avoid unnecessary separation experiments related with design parameters.

A Study on Shield Tunnel Assembling System Using a Cable and Island-Type Shear Key (강연선과 아일랜드타입 전단키를 이용한 쉴드터널 체결기술 연구)

  • Ma, Sang-Joon;Lee, Young-Sub;Kim, Dong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.17-25
    • /
    • 2015
  • In this study, a new segment assembling method using cable tensible force and island-type shear key was developed to improve the problems of bolt assembling method of shield tunnel. The bolting system and island-type shear key system were compared to analyze the mechanical behavior that occurs in the segment. The study results obtained from structural investigation and numerical analysis technique showed that the shear strength of island-type shear key is higher than that of the bolt system. With the increase of the tensile strength, it is expected that the stability of the segment will be secured.

Structural Tensile Capacities of Split-Tee Connection with High Strength Bolts (고력볼트 Split Tee 접합부의 인장내력)

  • Choi, Hye Kyoung;Choi, Sung Mo;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.541-549
    • /
    • 2003
  • Split-tee connection with High Strength Bolts is normally used in low and middle rise buildings in Europe because the structural efficiency and installation work of connections are excellent. However, the domestic situation is different from that in Europe. The analysis and the design for the T-split connection are complicated, because the structural behavior often T-split connection with High Strength Bolt is governed by so many parameters, i.e., prying action, bolt's tension, shear failure and plastic failure of flange plates. Many researches regarding the structural behavior of the split-tee connection have been undertaken in other parts of the world, such as the, Americas, Japan and Europe, but in the domestic context, this is a pioneering study. Therefore, the purpose of this paper is to supply basic data for the design of T-split connection, and to verify the structural characteristics that define reactions to prying action, based on an experimental study.

Application of Strength Reduction Method to Evaluation of Pillar Safety Factor in very Closely Spaced Tunnels (근접병설터널에서 필라부 안전율 평가를 위한 강도감소법의 적용성 연구)

  • Jun, Sung-Kwon;Yoon, Dong-Ho;Song, Jae-Joon;Kim, Se Hyung
    • Tunnel and Underground Space
    • /
    • v.29 no.5
    • /
    • pp.346-355
    • /
    • 2019
  • When evaluating pillar stability in very closely spaced tunnels, a local safety factor (strength/stress ratio) at the minimum width has been widely used. Tension bolts have been frequently applied as reinforcement for the cases where safety factors are less than 1.0 from FEM stress analysis. However, the local safety factor shows a constant value irrespective of the change in pillar width/tunnel diameter (PW/D) and the safety factor of the pillar is underestimated because the variation of deviation stress is relatively small even when the pre-stressing is applied to the tension bolt. In addition, the average safety factor proposed by Hoek and Brown(1980) was reviewed, but the pillar safety factor was relatively overestimated when the width of the pillar was increased. As an alternative, the SRM safety factor using shear strength reduction method shows the effect of changing the safety factor in the case of no reinforcement and tension bolt reinforcement as the pillar width/tunnel diameter(PW/D) changes. The failure shape is also similar to the previous limit theory result. In this study, the safety factor was evaluated without considering rock bolt and shotcrete to distinguish reinforcing effect of tension bolt.

Static behavior of bolt connected steel-concrete composite beam without post-cast zone

  • Xing, Ying;Zhao, Yun;Guo, Qi;Jiao, Jin-feng;Chen, Qing-wei;Fu, Ben-zhao
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.365-380
    • /
    • 2021
  • Although traditional steel-concrete composite beams have excellent structural characteristics, it cannot meet the requirement of quick assembly and repair in the engineering. This paper presents a study on static behavior of bolt connected steel-concrete composite beam without post-cast zone. A three-dimensional finite element model was developed with its accuracy and reliability validated by available experimental results. The analysis results show that in the normal service stage, the bolt is basically in the state of unidirectional stress with the loss of pretightening can be ignored. Parametric studies are presented to quantify the effects of the post-cast zone, size and position of splicing gap on the behavior of the beam. Based on the studies, suggested size of gap and installation order were proposed. It is also confirmed that optimized concrete slab in mid-span can reduce the requirement of construction accuracy.