• 제목/요약/키워드: Boiler water

검색결과 316건 처리시간 0.024초

공동주택용 태양열원 급탕시스템의 운전성능 연구 (A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses)

  • 이윤규;황인주
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석 (Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home)

  • 주홍진;이경호;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

석탄화력발전소 보일러 연소계통의 모델개발에 관한 연구 (A Stduy on Model Development of Boiler Combustion System on Coal Fired Power Plant)

  • 문채주;김용구;정환주
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.65-73
    • /
    • 2004
  • 석탄화력발전소의 보일러계통은 구성기기 사이에 수많은 상호관계를 갖는 대규모, 비선형 계통이다. 이러한 복잡한 계통의 해석에서 동특성 모의는 대규모 상호관계를 지속적으로 추적하는 강력한 방법으로 인식되고 있다. 보일러계통은 공기/가스 시스템과 물/증기 시스템으로 구성된다. 보일러의 오염물질 배출에 관한 최근 환경규제의 강화와 보일러의 물성치에 대한 설게 검증 요건 때문에 상업용 프로그램이 보일러 계통의 해석에 사용된다. 이 논문에서는 모의 도구로써 EPRI(미국전기연구소)에서 개발한 MMS를 사용하여 모델개발을 논의하였다. MMS에서 사용하여 개발된 모델은 한국표준석탄화력발전소의 보일러 연소계통에 대한 설계 및 현장데이터를 시험하였다. 개발된 모델은 정상상태 및 천이상태 조건에서 ${\pm}$5% 이내로 연소계통이 잘 응답하는 것으로 결과에서 보여준다. 이 논문에서 연소계통의 해석에 대한 개발된 모델은 일반적일고, 어떤 형식의 석탄호력발전소에도 적용이 가능하다.

국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석 (Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions)

  • 유병호;서병모;문진우;이광호
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

보일러 초음파 수처리장치의 신뢰성향상에 관한 연구 (A study on the reliability enhancement of Ultrasonic water treatment system to boiler)

  • 김대룡;이근오
    • 에너지공학
    • /
    • 제22권3호
    • /
    • pp.287-293
    • /
    • 2013
  • 이 논문은 보일러 운전중에 일어나는 결함요소의 하나인 스케일형성을 감소하기 위한 연구이다. 스케일의 결함은 보일러 튜브의 과열로 보일러 파열에 치명적인 영향을 미치거나, 보일러내부의 수의 순환 불량으로 내부의 물흐름에 영향을 미쳐 내부의 수의 불균등을 가져오기도 한다. 그리고 스케일은 보일러 재료보다 열전달이 되지 않음에 따른 에너지손실도 가져와 지구 온난화의 환경에 영향을 끼친다. 이러한 스케일의 형성을 방지하거나 제거하기 위하여 한국정부에서는 보일러수질관리를 위하여 2005년도에 스케일부착을 방지하거나 제거할 수 있는 장치를 시설하도록 하였다. 이러한 스케일형성 방지 및 제거하기 위한 기법에 관한 연구는 1821년 감자 전분에 의한 스케일형성 감소에 의한 연구를 시작으로 그 후 많은 연구가 있어왔다. 1994년 한국에 러시아 음향연구소의 한 과학자로부터 개발된 초음파 스케일 방지장치가 소개된 이래로 다양한 보일러에 보급되기 시작했다. 초음파 스케일방지 장치가 성능을 발휘할 수 있는 조건을 실증할 필요가 있다. 보일러는 대부분 원형 곡면의 본체와 튜브로 구성 되어 있다. 보일러의 구성 요소 중 스케일결함 가장영향을 많이 미치는 원통형에 대한 실증을 실시하였다. 그 결과 초음파의 일정음압과 주파수에 도달하여야 스케일형성에 영향을 미친다는 것을 확인할 수 있었다.

시뮬레이션을 활용한 유동층보일러 수냉벽튜브 검사용 원격장 와전류 탐상 센서 설계 (Design of Remote Field Eddy Current Sensor for Water-Wall Tube Inspection using Simulation)

  • 길두송;권찬울;조용상;김학준
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권1호
    • /
    • pp.33-38
    • /
    • 2019
  • 화력발전은 국내 발전량 중 가장 높은 비율을 차지하고 있으며, 그 중 석탄보일러 발전이 가장 높은 비율을 차지하고 있다. 석탄보일러는 석탄 연소 중 유해 물질 및 미세먼지가 발생하여 대기오염에 심각한 영향을 미친다. 이에 친 환경 석탄보일러로 유동층보일러가 도입 되었으며, 이는 유동매체를 활용하여 기존의 석탄보일러보다 약 1/10정도 적은 오염물질을 배출한다. 수냉벽튜브는 이 유동층보일러에서 중요한 역할을 하는 구조물로, 유동층보일러의 특성상 기존의 보일러보다 외벽손상이 심하다. 하지만 아직까지 이에 대한 정량적인 유지보수 기법이 없다. 원격장 와전류 탐상은 튜브형태의 내, 외벽 검사에 많이 사용되는 비파괴평가 기법으로, 비접촉이며 빠른 검사가 장점이다. 하지만 원격장 와전류 탐상은 본래 배관 내부에서 진행하는 검사이며, 수냉벽튜브는 특성상 내부 진입이 불가능하다. 이에 본 연구에서는 시뮬레이션을 활용해 유동층보일러 수냉벽튜브에 적합한 외부 원격장 와전류 탐상 센서에 대한 설계를 진행하고, 시뮬레이션을 수행하였으며, 기존 원격장 와전류 탐상과 유사한 신호를 얻음으로써 추후 실제 제작 될 원격장 와전류 탐상 센서에 대한 기준을 제시하였다.

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

FGR 시스템 공력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향 (Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in Power Plant Boilers with FGR System)

  • 배명환;정광호;최승철;조용수;김이석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1686-1691
    • /
    • 2004
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air(OFA) damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_{x}$ emissions. To activate the combustion, the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$ , and the OFA with 0 to 20% into the flame is supplied, as the combustion air supplied to burner is reduced. It is found that the fuel consumption rate divided by evaporation rate does not show an obvious tendency to increase or decrease with rising the FOR rate, and $NO_{x}$ emissions are decreased, at the same OF A damper opening, as FOR rates are elevated and boiler loads are dropped.

  • PDF

열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 - (Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF

석탄화력발전소 보일러 연료제어 알고리즘과 분산제어시스템의 개발 (The Development of Boiler Fuel Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;이흥호
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper is written for the development and application of boiler fuel control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. Fuel control algorithm has the upper algorithm and it is boiler master control algorithm that controls the fuel, feed water, air by generation output demand. Generation output demand by power load influences fuel control. Because fuel can not be supplied fast to the furnace of boiler, fuel control algorithm was designed adequately to control the steam temperature and to prevent the explosion of boiler. This control algorithms were coded to the control programs of distributed control systems which were developed domestically for the first time. Simulator for coal-fired power plant was used in the test step. After all of distributed control systems were connected to the simulator, the tests of the actual power plant were performed successfully. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.