가스보일러 배기통 이탈에 의한 CO가스 누출확산 실험 및 수치해석 (EXPERIMENTAL AND COMPUTATIONAL PREDICTION OF CONCENTRATION OF CARBON MONOXIDE GAS RELEASED FROM EXHAUST TUBE OF GAS BOILER)

  • 강승규;최경석;윤준용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.172-175
    • /
    • 2008
  • In the last five years, 45 people died and 104 were wounded because of carbon monoxide poisoning accident. CO poisoning accident is higher than any other gas accident in the rate of deaths/incidents. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of CO gas released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of CO alarm was made certain and suggested.

  • PDF

가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석 (Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler)

  • 강승규;최경석;윤준용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

공조용(空調用) 열원기기(熱源機器)의 대수분리(臺數分離) 제어(制御)에 관한 연구(硏究) (Multiple Units Control of Boiler and Refrigerator in HVAC System)

  • 손장열;김회서;안병욱;신용태
    • 설비공학논문집
    • /
    • 제4권1호
    • /
    • pp.1-10
    • /
    • 1992
  • The purpose of this paper is to provide an efficient method of operating and designing HVAC systems for reasonable energy consumption in building. Accroding to the conditions of indoor temperature and humidity, and the methods of dividing and grouping the capacity of boiler and refrigerator, the amount of their annual energy consumptions is simulated by using an energy analysis program which is developed in this paper, and opatimal design methods of HVAC system are suggested as well.

  • PDF

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석 (Analysis of energy consumption of office building by thermal resistance-capacitance method)

  • 이창선;최영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF

Study on the Microstructural Degradation of the Boiler Tubes for Coal-Fired Power Plants

  • Yoo, Keun-Bong;He, Yinsheng;Lee, Han-Sang;Bae, Si-Yeon;Kim, Doo-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.25-31
    • /
    • 2018
  • A boiler system transforms water to pressured supercritical steam which drives the running of the turbine to rotate in the generator to produce electricity in power plants. Materials for building the tube system face challenges from high temperature creep damage, thermal fatigue/expansion, fireside and steam corrosion, etc. A database on the creep resistance strength and steam oxidation of the materials is important to the long-term reliable operation of the boiler system. Generally, the ferritic steels, i.e., grade 1, grade 2, grade 9, and X20, are extensively used as the superheater (SH) and reheater (RH) in supercritical (SC) and ultra supercritcal (USC) power plants. Currently, advanced austenitic steel, such as TP347H (FG), Super304H and HR3C, are beginning to replace the traditional ferritic steels as they allow an increase in steam temperature to meet the demands for increased plant efficiency. The purpose of this paper is to provide the state-of-the-art knowledge on boiler tube materials, including the strengthening, metallurgy, property/microstructural degradation, oxidation, and oxidation property improvement and then describe the modern microstructural characterization methods to assess and control the properties of these alloys. The paper covers the limited experience and experiment results with the alloys and presents important information on microstructural strengthening, degradation, and oxidation mechanisms.

ASR 소각재의 이화학적 물성 및 재활용(再活用)을 위한 기초연구(基礎硏究) (A Study on the Characteristics and Utilization of Ash from ASR Incinerator)

  • 이화영
    • 자원리싸이클링
    • /
    • 제16권2호
    • /
    • pp.32-39
    • /
    • 2007
  • 폐자동차 ASR의 소각재를 대상으로 물리화학적 물성측정 및 리싸이클링을 위한 경량재료 제조실험을 수행하였다. 대상시료는 국내 ASR 소각장에서 채취한 바닥재 2종류와 비산재 4종류이었으며, 이들의 주요 성분 및 입도분석을 실시하고 공정시험법에 의한 중금속 용출량을 조사하였다. 또한, 비산재인 boiler ash를 원료로 하여 경량물질과 무기바인더를 첨가하여 성형 및 소성하는 방법으로 경량재료를 제조하였다. 바닥재에 Cu 함량이 3wt% 내외로 상당히 높은 것으로 나타나 Cu의 사전 분리가 필수적인 것으로 나타났다. 수용성물질을 많이 함유한 SDR(semi-dry reactor) ash와 Bag filter ash의 주성분은 각각 $CaCl_2{\cdot}Ca(OH)_2{\cdot}H_2O$$CaCl_2{\cdot}4H_2O$인 것으로 나타났다. boiler ash를 원료로 사용하여 제조한 경량재료 시편의 경우 중금속 용출이 크게 감소하였으며, 그 이유는 중금속 성분이 불용성 화합물천 안정화 또는 encapsulation 되었기 때문으로 판단되었다.

시뮬레이션을 통한 지열 히트펌프 시스템과 VRF 시스템의 에너지 성능비교 (Comparison of Energy Performance between Ground-Source Heat Pump System and Variable Refrigerant Flow(VRF) Systems using Simulation)

  • 손병후;임효재;강성재
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.30-40
    • /
    • 2021
  • This paper compares the annual energy performance of four different types of air-conditioning systems in a medium-sized office building. Chiller and boiler, air-cooled VRF, ground-source VRF, and ground-source heat pump systems were selected as the systems to be compared. Specifically, the energy performance of the GSHP system and the ground-source VRF system were compared with each other and also with conventional HVAC systems including the chiller and boiler system and air-cooled VRF system. In order to evaluate and compare the energy performances of four systems for the office building, EnergyPlus, a whole-building energy simulation program, was used. The EnergyPlus simulation results show that both the GSHP and the ground-source VRF systems not only save more energy than the other two systems but also significantly reduce the electric peak demand. These make the GSHP and the VRF systems more desirable energy-efficient HVAC technologies for the utility companies and their clients. It is necessary to analyze the impact of partial load performance of ground-source heat pump and ground-source VRF on the long-term (more than 20 years) performance of ground heat exchangers and entire systems.

에너지사용계획 협의대상 시설여부를 판별하기 위한 간편한 기준에 관한 연구 (A Study on the Simple Criteria to distinguish being or not facilities of Consultation about Energy Use Plan)

  • 서광수
    • 한국산학기술학회논문지
    • /
    • 제12권10호
    • /
    • pp.4704-4710
    • /
    • 2011
  • 본 논문에서는 사업주관자, 건축 및 시설관련 종사자 또는 행정관청 담당자 등이 건축물 또는 공장시설이 에너지사용계획 협의대상 시설에 포함되는지를 판별할 수 있는 간편한 기준을 설정하기 위하여 자료 분석 및 사례 분석을 실시하였다. 분석결과 건축물은 공공사업인 경우 연면적 75,000 $m^2$ 이상 또는 수전용량 9,000 kVA 이상을, 민간 사업인 경우 연면적 100,000 $m^2$ 이상 또는 수전용량 11,500 kVA 이상을 협의대상이 되는 기준으로 제시한다. 또한 공장 시설은 민간사업인 경우 수전용량 6,000 kVA 이상 또는 보일러 용량 24 톤/h 이상을, 공공사업인 경우 수전용량 3,000 kVA 이상 또는 보일러 용량 12 톤/h 이상이면 협의대상이 됨을 알 수 있다.

LCC 분석을 이용한 중앙공급식 공동주택의 수축열식 지열원 히트펌프시스템의 적용연구 (Application study of heat storage type GSHP system in Apartment building with central cooling and heating facilities using life cycle cost analysis)

  • 이상훈;박종우;조성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1497-1502
    • /
    • 2009
  • The present study has been conducted economic analysis of heat storage type ground source heat pump system(HSGSHP) and normal ground source heat pump (GSHP) and central boiler system with individual air conditioning facility which are installed at the same building in the shared an apartment house. Cost items, such as initial construction cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and simple payback period (SPP) with initial cost different are compared. The initial cost is a rule to the Government basic unit cost of production. LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are prices escalation rate and interest rate mean values of during latest 10 years. The LCC result shows that HSGSHP (1,351,000,000won) is more profitable than central boiler system with individual air conditioning facility by 86.7% initial cost. And SPP appeared 8.0 year overcome the different initial cost by different annual energy cost.

  • PDF