• Title/Summary/Keyword: Body temperature checking

Search Result 15, Processing Time 0.027 seconds

Preparing a Body Temperature Checking Material Using Polydiacetylene (Polydiacetylene을 이용한 체온 측정 물질의 제조)

  • Kim, Huiseon;Heo, Eunjin;Shin, Min Jae
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.219-223
    • /
    • 2021
  • Considering the current COVID 19 pandemic, herein, we developed a material that can be used to fabricate a device for checking the body temperature of a person who has been exposed to influenza or corona virus. This material was formed by mixing pluronic F127 (F127) with a polydiacetylene (PDA) vesicle, which was formed with 10,12-pentacosadiynoic acid. The color of the system started to change from blue to light purple at 37 ℃, finally turning reddish at 40 ℃. Thus, the developed material can be used to detect changes in body temperature, and thus, detect signs of fever. The mixing ratio of the PDA vesicle and F127 was an important factor for controlling the temperature at which the color change started. The results showed that the color change accompanied by the separation of the PDA vesicle with F127. We believe that this phenomenon plays an important role in reducing the conjugation length in the double and triple bond of PDA.

The Foot Pressure Change Caused by Functional Leg Length Having an Effect on the Foot Temperature (기능적인 하지길이 차이에 따른 족저압 변화가 족부체열에 미치는 영향)

  • Kim, Minju;Kim, Juyeon;Lee, Hyewon;Yim, Juyeon;Ha, Hyunjin;An, Jinho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.2
    • /
    • pp.37-46
    • /
    • 2013
  • Purpose : The purpose of the research was to analyze foot pressure, foot temperature, and correlation between foot pressure and foot temperature to grasp impact on foot pressure and body temperature distribution chart depending on functional difference of leg length. Method : After measuring leg length, put 15 students whose functional difference of leg length was over 10mm to difference group and 15 students whose functional difference of leg length was under 5mm to normal group and categorize soles of foot into 6 sections of hallux head, 1st metatarsal head, 2-4 metatarsal head, 5 metatarsal head, lateral heel, and then measure by foot pressure analyzer to analyze characteristic of pressure distribution and classify into front of the lower leg, back of the lower leg, soles of foot and measure by body temperature analyzer to analyze by checking body temperature. Result : Weight difference depending on foot pressure and body temperature was bigger when functional difference of leg length was bigger, and it could be confirmed that foot pressure and body temperature of short leg side were higher than those of short leg side. Thus, if difference exists in leg length, weight load on short leg side increases which results in higher foot pressure and body temperature, therefore enabling an assumption that mechanical problem will occur in short leg. Conclusion : When functional leg length inequality, weight bearing and pressure was getting high as a result, temperature was getting high in short leg.

Studies on the Development of Easy-checking Thermometer to Detect the Diseased Domestic Animals with fever (가축 질병 이환상태의 확인을 위한 간이 체온계 개발에 관한 연구)

  • 김용준;한경호;이창민;홍유미
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.28-36
    • /
    • 2002
  • These studies were carried out to develop some easy-checking thermometers instead of taking temperature of ectum for the farmers to detect easily a diseased animal with fever. Thermometers such as pincher-type, hood-type, raser-type, stick-type, and wrap-type were devised for the experiments. The experimental animals were cattle, horse, swine, aprine, and canine. Temperature-taking parts of the body were ear, shoulder, axilla, gluteal part, and coccygeal part according o the devised thermometer. Rectal temperature was taken at the same time for the comparison of temperature between rectum nd the certain part. The difference of temperature between rectum and shoulder part using eraser-type thermometer for the domestic animals were $3.37^{\circ}C$ for cattle, $1.94^{\circ}C$ for horses, $2.04^{\circ}C$ for swine, $1.27^{\circ}C$ for caprine, $0.9^{\circ}C$ for canine. The difference of temperature between rectum and gluteal part using eraser-type thermometer for domestic animals were $3.46^{\circ}C$ for cattle, $1.98^{\circ}C$ for horses, $2.22^{\circ}C$ for swine, and $1.1^{\circ}C$ for canine. The difference of intra-individual temperature taken by eraser-type thermometer of shoulder and gluteal part were 0.3 and $0.8^{\circ}C$ for cattle, 0.7 and $1.1^{\circ}C$ for horses, 0.6 and $0.7^{\circ}C$ for swine, 0.9 and $1.1^{\circ}C$ for canine. The difference of temperature between rectum and shoulder part taken by hood-type thermometer for cattle was $3.93^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The difference of temperature between rectum and gluteal part taken by stick-type thermometer for cattle was $3.7^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The other types of thermometers than the above three were not proved to be reliable to detect temperature of domestic animals. It was concluded that hood-type, stick-type and eraser-type thermometers are recommendable devices of thermometer to detect easily the status of body temperature and that the eraser-type was proved to be a practical one of the thermometers used in this study.

Comparison of Clinical Outcomes between Rebound Hyperthermia and Non-Rebound Hypertherma Groups in Postcardiac Arrest Syndrome Patients Undergoing Targeted Temperature Management (목표체온유지치료를 적용한 심정지 후 증후군 환자에서 반동성 고체온 발생군과 비발생군의 임상결과 비교)

  • Rhee, Ha Na;Park, Jeong Yun
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.3
    • /
    • pp.99-108
    • /
    • 2023
  • Purpose : This retrospective study aims to provide basic data for intervention to improve clinical outcomes and identify the characteristics of the rebound hyperthermia (RHG) and non-rebound hyperthermia (NRHG) groups by checking body temperature in patients with post-cardiac arrest syndrome. Method : The study involved 118 patients who completed target temperature management (TTM) in an acute-care unit. Data were analyzed for frequency, percentages, mean, standard deviation, median, and quartiles, and compared using the chi-squared test and Mann-Whitney U-test. Results : Rebound hyperthermia (RH) was observed in 74 (62.7%) patients, predominantly male (69.5%), with an average age of 64.54 ± 15.98, and a body mass index of 23.22 ± 4.75kg/m2 (overweight). Hypertension (50%) was the most common co-morbidity, followed by diabetes and heart disease (33.1%). Neuron-specific enolase levels were higher in the NRHG 24, 48, and 72 hours after recovery of spontaneous circulation (p = .037, p < .001, p = .008). The APHCHE IV was also higher in the NRHG (p < .001). RH occurred 25.49 (7.28-52.96) hours after TTM completion, lasting for 2 (1-3) hours. Temperature reduction strategies included notifying doctors, administering antipyretics, and nursing intervention, with the latter being the most common at 94.6%. Half of the subjects in the RHG and 77.3% in the NRHG fell into cerebral performance categories 3, 4, and 5 (p = .003). Conclusion : RH is more likely a body mechanism related to CPR and TTM than a result of pathogenic infection. Therefore, we require an active intervention for hyperthermia, and a patient-specific nursing intervention protocol.

Implementation of Low-Power Ubiquitous Health System based on Real-Time Embedded Linux using ZigBee wireless communication (ZigBee를 이용한 실시간 임베디드 리눅스 기반의 저전력형 U-Health 시스템 구현)

  • Kwon, Jong-Won;Ayurzana, Odgerel;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.436-438
    • /
    • 2007
  • As the sensors and communication technology get advance, the remote health diagnosis for patients and senior persons at home are possible now without visiting doctors in hospitals. A low-power ubiquitous health check device was developed adapting Real-Time Embedded Linux is developed. This ubiquitous device is consisted of three sensors. The wrist type health checking terminal acquires periodically the health data by using a blood pressure sensor, a pulse sensor and a body temperature sensor. It transmits the health data to the access point located at the home center through the ZigBee wireless communication modem. This health data collector or access point device sends the data again to the main server operated in a hospital or health care organization. The health server control continuously the input data and sends an alarm signal to the assigned. doctor and responsible persons using cellular SMS when any dangerous events occur. This wrist type health check device has an embedded linux OS using Intel PAX255 MPU. The developed U-Health system is applicable for checking patients health in remote at home. And their family or related persons in remote site can check the patients health status at any time. They can be assured by receiving SMS record and alarm of emergency case which is transmitted from the health server.

  • PDF

Evaluation of Thermal Comfort during Sleeping in Summer - Part I : On Results of Questionnaire Before and After Sleep - (여름철 수면시 온열쾌적감 평가 - 제1보 : 수면 전후 설문에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.404-409
    • /
    • 2005
  • This study is to investigate effects of thermal conditions on sleep. Five female university students participated in the sleep experiment. Three temperature levels (22, 26, and $30^{\circ}C$) were given, and relative humidity was maintained to $50\%$. When as subject arrived in the chamber at 9 o'clock in the evening, questionnaire was given to check physical and psychological conditions. After checking conditions, subjects went to bed till 07 : 30 in the morning. Body movement was checked during sleeping. After sleep in the chamber, questionnaire was given to the subject in order to check sleep quality. Subjects evaluated sleep quality by themselves by answering the time they fall asleep and wake up, frequency of wake during sleep, causes of each waking, and feeling after sleep. Sleep quality was rated with 7-point scale. At $30^{\circ}C$ condition, body movement was significantly higher than of other thermal conditions. The best sleep quality was obtained at the $26^{\circ}C$ condition, while the worst sleep was taken at the $30^{\circ}C$ condition.

Development of Multichannel On-line Thermometry System (다 채널 직결 온도측정 시스템의 설계 및 제작)

  • Shin, Sei-One;Shin, Hyun-Jin;Kim, Myung-Se;Kim, Sung-Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.193-199
    • /
    • 1999
  • Background: Measurement of body temperature is an important parameter in patient management in many clinical conditions. Failure to reach minimal acceptable body temperature standards has been associated with physiological derangements and has necessitated the application of additional therapy. The authors developed a new, simple, accurate thermometry system, which could be used to undertake precise temperature measurement for various clinical conditions. Materials and Methods: A new thermometry system using a specially designed temperature detecting and display system was developed. This system contains a temperature detecting sensor(LM 35CZ), which enables multiple serial checking of heat, data collection and processing computer, and 3-dimensional display system. It provides real time volumetric visualization of temperature distribution of a defined volume and stores and prints the data. Results: With this system, temperature can be measured at multiple interesting sites simultaneously, demonstrated as a 3-dimensional temperature distribution and stored. In well-controlled, systematic experiments a significant correlation has been observed between standard temperature and temperature using this system at various measuring points. Conclusion: This thermometry system is a real-time measurement system, which can demonstrate 3-dimensional heat distribution in experimental phantom and human body and can be used for diagnosing abnormal clinical conditions. In addition, this system reduces the nursing staff work load, providing them more time for long term care to patients.

  • PDF

Effects of local cold application on tissue & peripheral oxygen saturation, peripheral blood flow, skin temperature, and body temperature of healthy adult (국소적 냉 요법이 정상 성인의 조직과 말초의 산소포화도, 말초 혈류, 피부 온도, 체온에 미치는 효과)

  • Kim, Seung Ok;Shin, Yong Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.127-136
    • /
    • 2020
  • Purpose: This study aimed to establish a basis for application time and cold therapy interval by checking the physiological changes after applying a cold-gel and ice pack, commonly applied to cold therapy, and after passive rewarming. Method: A total of 22 healthy adults used cold-gel packs and ice packs in a Randomized control group repeated measurement study, and passive rewarming was performed for 40 minutes after 30 minutes of cold therapy. After applying to the right axilla, StO2, SpO2, peripheral blood flow, skin and body temperature were measured 15 times every 5 minutes. Result: In the cold-gel pack group, StO2 decreased from 69.43% to 61.06% after 30 minutes application, and in the ice pack group, StO2 decreased from 67.66% to 64.80% (p <001). In the cold-gel pack group, skin temperature decreased from 33.57℃ to 29.15℃ after 30 minutes application, and in the ice pack group, skin temperature decreased from 32.64℃ to 28.90℃ (p <.001). Only skin temperature recovered completely after 40 minutes of rewarming. There were insignificant differences between the cold-gel pack and ice pack. Conclusion: When applying cold therapy to the axillary, at least 40 minutes for passive rewarming is necessary after 30 minutes of application.

Response properties of alcohol gas sensors depositing MWNT-composites by spray method (MWNT를 스프레이 코팅한 가스센서의 알콜 가스 응답 특성)

  • Choi, Young-Min;Gam, Byung-Min;Lee, Ho-Jung;Kim, Seong-Jeen
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.382-383
    • /
    • 2008
  • In this paper we presented experimental results of a gas sensor utilizing multi-walled carbon nanotube (MWNT)composites for the alcohol detection which is useful to checking drinking and driving, for example. The MWNT-composites were deposited using spray method on PES substrates suitable for use in low-cost and flexible sensors. We observed the variation of conductance from the sensors exposed to alcohol vapors evaporated at 37C equal to the human body temperature to match real condition. As the result, the conductance was decreased with the increase of ethanol vol% diluted in water. The sensors showed good sensitivity and linearity.

  • PDF

Effects and Safety of Electroacupuncture on Cold Hypersensitivity on Hands and Feet by Sasang Constitution: A Multi-center, Randomized Controlled Trial (수족냉증에 대한 전침치료의 사상체질별 효과 및 안전성: 다기관 무작위 대조군 연구)

  • Kwon, Na-Yoen;Yu, Jun-Sang;Kim, Dong-Il;Kim, Hyeong-Jun;Lee, Dong-Nyung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.33 no.2
    • /
    • pp.47-64
    • /
    • 2021
  • Objectives The purpose of this study was to figure out the effect and safety of electro-acupuncture and acupuncture on cold hypersensitivity on hands and feet(CHHF) by Sasang constitution. Methods 72 subjects were recruited from three Korean medical hospitals from October 2019 to October 2020. Subjects were randomly allocated in 1:1:1 ratio to electro-acupuncture group(EA group), acupuncture group(AC group), and control group. The EA and AC group received treatment twice a week for 5 weeks. We tried to confirm the effectiveness of electro-acupuncture and acupuncture treatment by checking changes in Visual analogue score(VAS), body temperature of LU4, PC8, ST32, LR3, and WHOQOL-BREF score. Results The VAS score of CHHF was reduced after treatment, and the effect continued for 4 weeks after the end of treatment in all Sasang constitution, all treatment groups. In all Sasang constitution, the body temperature of the electro-acupuncture group or acupuncture grouop was higher than that of the control group except LU4 in visit 11. And no clinically significant adverse events have been identified. Conclusions Electro-acupuncture and acupuncture treatment are effective on hypersensitivity on hands on feet, and the effect was shown regardless of Sasang constitution.