• Title/Summary/Keyword: Body scan data

Search Result 218, Processing Time 0.025 seconds

Feasibility Study of Applying the Acrylic Assistant Equipment (ACR) to Reduce Patient's Discomfort in Lower Abdomen MRI Scan (하복부 MRI 검사 시 환자의 불편함을 줄이기 위한 아크릴 보조 장치 사용의 타당성 조사)

  • Park, Eunhye;Lee, Minsik
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.475-480
    • /
    • 2018
  • In lower abdominal MRI scan, patients have been tested by physically contacting with the body array coil. In this study, we have designed the acrylic assistant equipment (ACR) which allows the contactless scan of the patient to the coil and evaluated the feasibility by comparing the acquired images with ACR to those obtained without ACR. We tested 10 cases (F: 5, m: 5) by using the Ingenia $3.0T^{TM}$ MR system and dStreamTM torso coil (Philips Healthcare, Netherlands). We implemented T1 AX TSE and eTHRIVE (GRE) techniques. The scanned images were quantitatively and qualitatively assessed. In qualitatively, the TSE shows 4.44 and 4.56 mean values with and without the ACR and 4.34 and 4.28 at the GRE, respectively. In quantitatively, the TSE shows 12.15 CNR, 17.95 SNR and 12.71 CNR, 18.96 SNR with and without the ACR. And GRE shows 17.72 CNR, 22.59 SNR and 18.26 CNR, 24.47 SNR with and without the ACR, respectively. We have designed and implemented the acrylic assistant equipment to lower abdominal patients. Our data indicate that it is possible to obtain similar image qualities to current lower abdominal MRI scan without the physical contact to the patient.

A Study on the Breast Shape Analysis of Big-breasted Women (볼륨 유방 여성의 흉부체형 분석에 관한 연구)

  • Han, ChoHee;Yi, Kyong-Hwa
    • Journal of Fashion Business
    • /
    • v.22 no.5
    • /
    • pp.32-40
    • /
    • 2018
  • Big breasted women often experience dissatisfaction with ready-made brassieres, that do not account for individual breast types nor provide adequate cup sizes. This study was conducted to provide basic information on common breast shape and measurements of Korean big-breasted women, and to facilitate development of big-breasted women's bras with excellent fit and comfort. The study analyzed direct upper body measurements of 178 women in their 20's whith cup size C or bigger in the 5th, 6th and 7th Size Korea. In addition, 3D body scan data of women with bra size 75 and cup size C were re-collected and their breast types were examined. Average under-bust circumference of big-breasted women was 75 size in brassiere size. The average stature was 159.78 cm and the body weight was 60.33kg, indicating "overweight". Also, it was revealed that common breast types of big-breasted women, were hemispheric and cone types. The study can facilitate better understanding of breast shapes and sizes of standard big-breasted women, and will be useful as reference in selection of subjects in future studies.

A Study of 3D Virtual Fitting Model of Men's Lower Bodies in Forties by Morphing Technique. (모핑 기법을 활용한 40대 남성 하반신 가상모델 생성에 관한 연구)

  • Park, Sun-Mi;Nam, Yun-Ja;Choi, Kueng-Mi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.3 s.162
    • /
    • pp.463-474
    • /
    • 2007
  • With rapid expansion in e-retailing of apparel business, personalized fitting model service shows the possibility as the differentiated marketing strategy in cyber shopping. According as necessity of personalized fitting model construction rises, it is tried personalized fitting model creation in several fields such as computer engineering, mechanical engineering, information engineering. But, because existent study was concentrated only on human body modeling, it does not reflect average morphological characteristics of human body properly. In this study, we wish to examine if morphing is fit for expressing characteristic of average human body shape and suggest desirable morphing. We used 3-D scan data of 254 Korean middle aged men collected by Size Korea 2004. The result of this study are as follows: Lower body types were categorized by height hip girth and lower drop(hip girth-navel girth) which were main factors of lower body shape. Then each factor was divided into 3 groups respectively, 30% in the middle, over 30%, under 30%. In 27 groups, the group which belonged to 30% in the middle of height, 30% in the middle of hip girth, 30% in the middle of lower drop was selected as a representative group. We tested geometrical figure by differ volume, tilt, position of point. And we created a representative type of men's lower bodies by morphing the representative group and analyzed it's horizontal, vertical sections. A representative type which was created by morphing reflected a real body and changed realistically at the part of hip, crotch, calf muscle and so on. A cross sections of a representative type were similar to average cross sections of the representative group in size and shape. So it was proved that morphing was successful.

Briefs Pattern Making for Women in their 20's using 3D Parametric Human Body Model (3차원 파라메트릭 모델을 활용한 20대 성인 여성용 브리프 패턴 설계)

  • Choi, Sin-Ae;Park, Soon-Jee
    • Fashion & Textile Research Journal
    • /
    • v.12 no.5
    • /
    • pp.642-649
    • /
    • 2010
  • This study was designed to generate briefs pattern for women in their twenties using 3D parametric body model. 151 women in their 20's were random sampled and measured using Martine's anthropometry. And one subject was chosen as the representative subject for 3D scanning. Parametric model was generated of using CATIA P3, Unigraphics NX4.0, Rapidform 2006. And the 3D surface of parametric body model was flattened onto the 2D plane. 3 downscale ratios(0%, 10%, 15%) were applied to generated pattern to figure out what downscale ratio was suitable to make briefs with stretch fabric. 4 kinds of experimental briefs were made with stretch fabrics(0%, 10%, 15% downscale) and worn on the dressform. Subjective evaluation on the appearance was done and the data was analyzed by ANOVA with post-hoc test. Briefs pattern was generated through the process of flattening the parametric surface and arranging the patches to make briefs pattern by dart manipulation. The different ration of outline and area between 3D surface and 2D pattern were 0.22% and 0.09% respectively. It showed that a parametric model could provide a desirable pattern with minute size error. The results of subjective evaluation on the appearance of 4 experimental briefs showed that stretch briefs with 15% downscale ratio was evaluated most highly in most items. Findings imply that it is feasible to apply 3D parametric model to generate patterns for various items considering various fabric properties.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

The Availability of Diagnostic and Treatment Planning Computer in 700 Cancer Patients and Magnification Devices for CT (암환자 700예의 진단 및 치료 CT 이용율과 CT 확대장치)

  • Lee, Gui-Won;Park, Joo-Sun;Han, Yong-Moon;Yoon, Sei-Chul;Shinn, Kyung-Sub
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.81-85
    • /
    • 1987
  • It has been evident since 1972 that computed tomography(CT) can play an important role in treatment and managment of the cancer patients as four steps; diagnosis, satging Treatment and follow-up. In this paper, we intended to investigate the availability of CT scan and treatment planning computer in 700 cancer patients who have undergone radiation therapy at the division of radiation therapy, Kangnam St. Mary's Hospital, Catholic Medical College between Mar. 1983 and Dec. 1985. The result were as follow; 1. Of 700 irradiated cancer patients, 342 patients ($48.9\%$) were performed CT scan prior to radiation therapy. 2. The distribution of lesions in 342 patients having CT scans was like this; CNS (83 of 104 patients, $79.8\%$), abdomen (44 of 76 patients, $57.9\%$), pelvis (100 of 188 patients, $53.2\%$) etc. in order. 3. The treatment planning computer were used in 280 cancer patients ($40\%$). 4. Of the 280 cancer patients using treatment planning computer, 167 patients ($59.6\%$) applied diagnostic CT scan and remaining 113 patients ($40.4\%$) were made body contour to be used for radiation therapy planning by the treatment planning computer. Authors also made some magnification devices used for small multiformat CT images to magnify into life size, consisting of overhead projector (3M) I.V. stand and mirror. These enabled us to make less errors in tracing the small-sized CT images during input of the anatomical data into the treatment planning computer.

  • PDF

Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media (Barium 조영제의 농도 차이가 PET 검사에 미치는 영향)

  • Choi, Woo-Joon;Shin, Sang-Ki;Nam, Ki-Pyo;Park, Soon-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

Establishing Quantitative Evaluation Standards for the Shape Fitness test of Slacks (슬랙스 형태 적합성 평가의 정량적 평가 기준 설정)

  • Kim, Seonyoung
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.695-707
    • /
    • 2016
  • This study presents quantitative evaluation standards for the shape fitness test, conducted in the process of the slacks fit test. This study aims to quantify appearance sensory test of slacks for the objectification of qualitative evaluation methods in existing shape fitness tests. The subjects were women of standard body type between the ages of 18 and 24. Slacks differing in their ease in waist girth, hip girth, crotch length and knee length were designed to test their shape fitness. The gap volume distribution between the body and slack, angle of the baseline by body part, and ratio of total thickness from the sideline using 3D human body scan data (which reflect the results of the appearance sensory test) were presented as quantitative evaluation standards. There were less wrinkles in the wrinkle/overstretch and ease categories of the appearance sensory test; in addition, ease was adequate and small enough to comfortably perform basic human activities in the standing upright posture. The gap volume distribution analysis between body and slacks showed that curves increased in the slacks surface along with an increase of ease in slacks and suggested that wrinkles also increased. In the baseline's horizontal categories in terms of a $0^{\circ}$ horizontal angle, the range of angles were evaluated as adequate by the clothing expert group. The total thickness ratio of 0.5:0.5 divides into the sideline from the baseline.