• Title/Summary/Keyword: Body scan data

Search Result 218, Processing Time 0.027 seconds

Development of Skirt Pattern for the Middle Aged Women of Obese using the 3-Dimension Technology (3차원을 이용한 중년 비만 여성용 스커트 설계 방법론 연구)

  • Sohn, Boo-Hyun;Kim, So-Young
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.5
    • /
    • pp.852-862
    • /
    • 2008
  • The purpose of this paper is to find how to do the width of skirt and the girth of the waist in the adequate pattern making for the obese women's skirt. Appearance test of the five experimental skirts was evaluated by the four experts in clothing construction. At the same time, 3D clothing air volume was observed for the five types of experimental skirt with different size specifications. The results from the appearance test were as follows; when the width of skirt pattern is set for(the shell girth/2), it was suggested w/4+1(front), w/4(back) for girth of the waist. On one hand, in case of (the shell girth of front)/2+(the shell girth of back)/2, it was suggested(the waist girth of front)/2 and(waist girth of back)/2 for obese women's skirt with the best appearance. As results, it was found that the width of skirt pattern for the obese women should be the greatest shell girth instead of hip girth. In the case of the hip girth, the amount of ease on hip was suggested 6cm. It was found that pattern with the wrinkle of ease was full of the gaps between body and skirt in 3D clothing air volume. In spreading out to 2D flat pattern from 3D scan data, when the width of skirt pattern was set for(the shell girth of front)/2+(the shell girth of back)/2, it was suggested(the waist girth of front/2)+(the waist girth of back/2) than the shell girth/2 in girth of the waist for the best appearance. And the conversion of 3D scan data into 2D flat pattern in curve shape of crosswise had to spread out of the plane in straight line. The obese women's clothing should be manufactured with systematical consideration of the diversity and scarcity of the obese women's body shape.

  • PDF

A study of making a dress form for women using a 3D printer (3D 프린터를 이용한 여성용 인대 제작 연구)

  • Oh, Seol Young
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.6
    • /
    • pp.725-742
    • /
    • 2016
  • In the Korean fashion industry, 3D printing systems are considered as new technology and a new opportunity. With 3D printers, consumers can be manufacturers and individuals can develop businesses with little upfront capital. In this study, a dress form for the typical Korean women's body shape was developed using 3D technology (3D scanning, 3D modeling, and 3D printing). Ten women with apparel sizes 85-91-160 were selected from 3D body-scan data collected by SizeKorea of 201 women aged 25 to 34 (2010). First, 15 horizontal cross-sections were collected from the 3D scan data of the 10 subjects. Then, inside lines of those cross-sections were drawn at 15-degree intervals, and the lengths were measured. The average of the inside lines was connected to the internal spline curve, and the curves were used as the average cross-sections. The average torso body and the dress form of Korean women were developed into a 3D solid model using a 3D CAD program (Solidworks 2012). An output mockup was printed by the FDM type's 3D printing system (Bonbot 1200, Bonbot 3-H4) using PLA material. The dimensions comparing the 3D solid modeling to the 3D printed mockup of the dress form were measured, and minor differences were between 0.00cm and 0.40cm. In the future, 3D printing systems are expected to be in use for various personalized dress forms.

Analysis on Lower Body Type and 3D Virtual Appearance Evaluation of Boots cut Jeans for Women (성인여성의 하반신 체형분석 및 부츠 컷 청바지의 가상 외관평가)

  • Choi, Jin;Do, Wol-Hee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.2
    • /
    • pp.73-83
    • /
    • 2008
  • The focus of this research was concerned with studying lower body type for Korean adult females. information from the measuring values based on research on the physical standard of the nation(2004) were summarized, in addition a factor of the need for appropriate fit in boots cut jean wear, basic lower body part applying to each item had to be taken into consideration to enhance sizing suitability. The body type are classified into three kinds by means of factor analysis and cluster analysis. Type 1 referred to the fat lower body, having thick rounding waist. compared to other body parts, and long leg according to its proportion. Type 2 represented medium stature but with a large skeleton structure of lower body. Type 3 represented a the long lower body having slender rounding waist. This study was attempted to evaluate the fitness of boots cut jeans pattern for women using 3D Clothes Modeling Software.

Energy Consumption of Taekwondo Practitioners due to a Thigh Muscle Extracted by CT Scan (CT Scan으로 추출한 허벅지 근육량에 따른 태권도 수련자의 에너지 소모량)

  • Kim, Changmo;Ha, Insuk;Lee, SangBock
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.199-204
    • /
    • 2013
  • Despite the suzerain of Korea Taekwondo physical activity and a corresponding lack of basic research on energy consumption and the status of this research is urgent. In this study, the sensor (SenseWear (R) PRO2 Armband), using physical activity were obtained in Taekwondo, and body composition data were obtained by Inbody 520, We were thigh scan using CT scanner and thigh muscle area by CT scan data were acquired. Result of analysis, average thigh muscle area of experimenter 8 people was 132.79 $cm^2$, Of 20 cm above the patella thigh was a 178.79 $cm^2$. Thigh circumference and muscle area showed that the correlation. The average energy consumption per minute was 6.94 calories, and thigh muscle area and average energy consumption per minute also showed that correlation.

Discovery of the Dmitri Donskoi ship near Ulleung Island(East Sea of Korea), using geophysical surveys (물리탐사기술을 이용한 침몰선 Dmitri Donskoi호 탐사)

  • Yoo, Hai-Soo;Kim, Su-Jeong;Park, Dong-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.104-111
    • /
    • 2005
  • Dmitri Donskoi, the Russian cruiser launched in 1883, is known to have sunk near Ulleung Island (East Sea, Korea) on May 29, 1905, while it was participating in the Russo-Japanese War. In order to find this ship, information about its possible location was obtained from Russian and Japanese maritime historical records. The supposed location of the ship was identified, and we conducted a five-year geophysical survey from 1999 to 2003. A reconnaissance three-dimensional topographic survey of the sea floor was carried out using multi-beam echo sounder, marine magnetometer, and side-scan sonar. An anomalous body identified through the initial reconnaissance survey was identified by a detailed survey using a remotely operated vehicle, deep-sea camera, and the mini-submarine Pathfinder. Interpretation of the acquired data showed that the ship is hanging on the side of a channel, at the bottom of the sea 400 m below sea level. The location is about 2 km from Port Jeodong, Uleung Island. We discovered 152 mm naval guns and other war materiel still attached to the hull of the ship. In addition, the remnants of the steering gear and other machinery that were burnt during the final action were found near the hull. Strong magnetic fields, resulting from the presence of volcanic rocks in the survey area, affected the resolution of the magnetic data gathered; as a result, we could not locate the ship reliably using the magnetic method. Severe sea floor topography in the gully around the hull gave rise to diffuse reflections in the side-scan sonar data, and this prevented us from identifying the anomalous body with the side-scan sonar technique. However, the sea-floor image obtained from the multi-bean echo sounder was very useful in verifying the location of the ship.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

Comparative Assessment of Virtual Garments using Direct and Manual Avatars (가상아바타에 따른 가상의복의 비교평가)

  • Lim, Ho-Sun;Istook, Cynthia L.
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1359-1371
    • /
    • 2011
  • The purpose of this paper is to compare two avatars made using direct and manual methods and to evaluate the fit and appearance of two virtual garments on the direct and manual avatars. In this study, two subjects were measured by $[TC]^2$ body scanner and the avatars and virtual garments were created by OptiTex software. The direct avatar was made by the direct importation of 3D body scan data and the manual avatar was made by manual input from extracted body measurement. Two virtual garments in a tank-top were evaluated by distance, transparency, and stretch maps. In the results of comparing difference of the direct and manual avatars, the bust and back of the manual avatar are protruded slightly more than that of the direct avatar and the manual avatar is slightly larger dimensions at the bust, waist, abdomen, and hip area in the side view in case of subject 1 and 2. In the results of comparing difference of the fit and appearance of two virtual garments on the direct and manual avatars, in case of subject 1 and 2, the back of the virtual garment on the manual avatar are protruded more than that of the direct avatar. Also, the ease in the bust area of the virtual garment on the manual avatar with a projected bust area was smaller than that of the virtual garment on the direct avatar and the stretch of that of the manual avatar was also high in the bust area. The results of this study are expected to be used as basic information in the apparel industry using virtual try-on technology.

Designing of standard sizing system for hygienic masks (의약외품 마스크의 표준 치수 규격 개발)

  • Oh, Seol Young;Suh, Dong Ae
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.4
    • /
    • pp.495-512
    • /
    • 2022
  • This study aims to design a new sizing system for hygienic masks to protect against COVID-19-related respiratory disorders. The product sizes were collected from 70 commercially available hygienic masks, and 18 head measurements were obtained from the three-dimensional (3D) scan data of 2,048 men and women aged 20 to 69 years from the 6th Size Korea Survey. The statistical analysis was performed using the IBM Statistical Package for the Social Sciences (SPSS) 28.0 program. The "bitragion-subnasale arc" and "menton-sellion length" were chosen as the key body dimensions for the hygienic mask sizing system. The linear regressions with 18 3D head measurements were analyzed, and it was determined that the key body dimensions were useful for statistically predicting other 3D head measurements related to hygienic masks. A new sizing system was proposed for two types of masks, "masks with a tight fit" and "masks with a loose fit," taking into account the existing Korean Industrial Standards (KS) and the shortcomings of the sizes of hygienic masks on the market. The sizing system for tight-fitting masks consisted of the key body dimensions, with their sizes indicated by a pair of numbers. The sizing system for loose-fitting masks consisted solely of the bitragion-subnasale arc, with their sizes denoted by letters such as S, M, and L (denoting small, medium, and large, respectively). Future studies should consider this mask sizing system for different age groups, such as children and adolescents.

A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project- (대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로-)

  • Sunmi Park
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.2
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.

Bodice Pattern Development of the Slim-fit Dress Shirt for Middle-aged Males Using 3D Body Scanning Data (3D Body Scanning Data를 활용한 중년 남성용 슬림 핏(Slim-fit) 드레스 셔츠 바디스 패턴개발연구)

  • Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.1
    • /
    • pp.171-187
    • /
    • 2016
  • The study performed a comparison analysis of market brand patterns for slim-fit dress shirts and analyzed the body surface development figure of men in their 40s using 3D body scan data and developed slim-fit dress shirt patterns suitable for middle-aged men. The sizes of slim-fit dress shirt patterns showed a slight difference depending on brand. The overlap map of slim-fit dress shirt patterns for brands demonstrates how difference of one-dimensional sizes reflect on two-dimensional patterns. This map provides useful information for pattern design and allows and easy recognition of pattern size differences. A try-on system evaluation through 3D-Simulation allows a grasp of the fitness of neckline and size tolerance of under the arms in front, the silhouette of side lines, and overall fitness in front that also allows analysis of the front/back balance of a shirt in side, the size tolerance proportion in front/back, and the fitness of the arm-hole line. Thus, we obtained try-on results that were equivalent to wearing actual clothing. According to the drafting size suggested in the developed final pattern, the total width was 'C/2+5.5cm', and the front was set at 1cm bigger in the size difference of the front and back. The width of the front neck and the back neck was set identically at 'C/12', while the width of the front neck was set to 'C/12+1.5cm'. For the armhole depth, we added 'C/4+2cm', and '0.5cm and 1.5cm' for the width of the front and back to anthropometry. The results of the try-on evaluation through 3D-Simulation indicated that the fitness of the final slim-fit dress shirt pattern was superior to available slim-fit dress shirt patterns on the market and evaluated as superior to the types for middle-aged men.