• Title/Summary/Keyword: Body phantom

Search Result 344, Processing Time 0.032 seconds

다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가 (Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions)

  • 이창래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.13-18
    • /
    • 2017
  • 본 논문은 GATE (geant4 application for tomographic emission) 시뮬레이션을 이용하여 다양한 모양과 재질의 팬텀에서 CTDI (computed tomography dose index)를 평가하였다. GATE 시뮬레이션은 실린더 기둥, 타원 기둥과 육각 기둥 형태와 물, PMMA (polymethyl methacrylate), polyethylene 그리고 polyoxymethylene 재질의 다양한 지름(1 ~ 50 cm)의 팬텀을 모사하여 $CTD_{I100center}$ 값을 비교하였다. 120 kV, 200 mAs에서 실린더 기둥, 타원 기둥과 육각 기둥의 $CTDI_{100center}$ 값은 각각 11.1, 13.4 그리고 12.2 mGy이었다. 이 결과는 동일 볼륨이지만 팬텀의 형태에 따라 $CTDI_{100center}$ 값의 차이가 있음을 알 수 있다. 그리고 물, PMMA 그리고 polyoxymethylene 팬텀의 $CTDI_{100center}$ 값을 비교했을 때 물질의 밀도가 높을수록 상대적으로 $CTDI_{100center}$ 값이 낮게 측정되었다. 하지만 polyethylene의 경우 지름이 15 cm ($CTDI_{100center}$ : 35.0 mGy) 이 상에서는 PMMA 보다 $CTDI_{100center}$ 값이 증가하였다. 그리고 30 cm ($CTDI_{100center}$ : 17.7 mGy) 이 상의 지름에서는 물 보다 더 높은 $CTDI_{100center}$ 값을 보였다. 본 실험을 통해 팬텀의 재질 및 모양에 따른 $CTDI_{100center}$ 값을 GATE 시뮬레이션을 이용하여 평가하였다. CT 선량 평가시 다양한 재질 및 인체에 가까운 모양의 팬텀을 사용함으로써 좀 더 정확한 환자선량을 평가할 수 있을 것이다.

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구 (The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT)

  • 도용호;송호준;이형진;이홍재;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Siemens사의 CT 선량 감소 소프트웨어인 IRIS의 적용을 통하여 CT 선량 감소 시 노이즈 감소 효과와 해상력의 보존 그리고 ACCT에 IRIS 각 kernel의 적용 시 SUV 변화를 확인하는데 목적을 두었다. Biograph mCT 40 slice 스캐너를 이용하여 AAPM CT performance phantom, Anthropomorphic chest phantom을 관전압 120 kVp로 고정하고 100-10 mAs까지 15%감소하여 스캔 후 FBP, IRIS 각 kernel을 적용하여 재구성 하여 영상의 노이즈, 해상력, 영상 평가를 시행하였다. NEMA IEC body phantom을 이용하여 55.5 MBq를 background에 주입하고 열소와 배후 방사의 비를 8:1이 되도록 모형을 제작하였다. 120 kVp, 50 mAs 조건으로 1분, 2분, 3분, 4분 스캔하여 영상을 획득한 후 ACCT에 IRIS 각 kernel을 적용하여 기존 FBP 방식을 적용한 SUV와의 평가를 시행하였다. IRIS의 적용 시 기존 FBP 방식에 비하여 45% 선량을 감소하였음에도 불구하고 해상력 저하 없는 노이즈 감소 효과가 확인 되었으며 SUV 평가 실험에서 IRIS의 I70f kernel을 제외하고는 기존 FBP 방식을 통하여 획득된 SUV와 유의한 차이가 나타나지 않았다. 본 연구를 통하여 IRIS 적용 시 기존 FBP 방식에 비하여 CT 피폭선량 감소와 해상력 저하 없는 노이즈 감소 효과를 입증하였으며 IRIS kernel의 적절한 적용을 통하여 PET/CT 검사 시 환자 피폭선량 감소는 물론 FBP 방식에 비하여 우수한 영상의 획득이 가능할 것이라 사료된다.

  • PDF

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.316-324
    • /
    • 2004
  • 목적 : 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사 체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 대상 및 방법 : 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range $3\~3$ m), Computer (RS232C), Sewo Motor (Torque 2.3 Kg) 등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 결과 : 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}1\%$ 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 $2.34{times}10^{-4}$초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 결론 : 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}1\%$ 이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34H10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가 (Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT)

  • 이충운;유연욱;문종운;김윤철
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

체적소팬텀과의 장기선량 비교를 통한 MIRD팬텀 몸통두께 수정 (Modification of Trunk Thickness of MIRD phantom Based on the Comparison of Organ Doses with Voxel Phantom)

  • 이춘식;박상현;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.199-206
    • /
    • 2003
  • 대표적인 수학적 팬텀인 MIRD팬텀은 개발 당시 컴퓨터 계산시간을 단축하기 위해 단순화된 수학방정식으로 표현되었으며 본래 내부피폭 선량계산에 이용하기 위해 제작되었으므로 실제 인체구조에 근접하는 정도와 외부피폭 선량계산 용도로서의 적합성 여부를 평가할 필요가 있다. 본 연구에서는 인체의 단층촬영영상을 이용하여 제작된 Zubal 체적소팬텀과 MERD팬텀이 가장 일반적인 피폭모드인 AP 및 PA모드 감마선장에 노출될 때 장기선량 계산결과 및 단층영상을 비교하여 선량차이의 주요 원인이 되는 MIRD팬텀의 몸통두께를 수정하였다. AP와 PA방향으로 입사하는 0.05MeV에서 10MeV의 에너지 범위를 가진 넓고 평행한 단일 에너지 감마선장에 대해 MIRD팬텀과 Zubal팬텀의 장기선량을 MCNP4C를 이용하여 계산 및 비교한 결과 저에너지 영역에서 AP와 PA방향 모두 MIRD팬텀이 Zubal팬텀보다 높은 선량을 받았으며 유효선량의 경우 특히 PA방향, 0.05MeV 광자빔에 대해서 50%에 가까운 선량차이를 보였다 몸통부분 단층영상을 비교한 결과 Zubal팬텀에 비해서 MIRD팬텀의 몸통 두께가 얇아서 나타나는 결과임을 확인하게 되었고 MIRD몸통두께의 최적값을 찾아내기 위해 20cm에서 32cm까지 변화시켜가며 원전 작업환경에서 가장 많이 받게되는 0.5MeV 감마선에 대한 유효선량을 계산하여 비교하였다. AP방향에서는 24cm, PA방향에서는 28cm일 때 최소의 선량차이를 보이는 것으로 나타났고 이에 따라 몸통모델을 수정하였다. 수정된 MIRD팬텀을 이용하여 장기선량을 재계산하여 Zubal팬텀의 선량과 비교한 결과 특히 PA방향에서 큰 과대평가를 보였던 장기들의 선량차이가 현저하게 줄었고 유효선량의 경우 0.5 MeV 광자빔에 대해 AP, PA방향 각각 -0.5%와 7.3%의 낮은 선량차이를 보였다. Zubal팬텀에 의해 계산된 선량환산인자는 ICRP74에서 제공하는 값과 큰 차이를 보이고 있으며 수정된 MIRD팬텀은 Zubal팬텀의 값에 준하는 결과를 보였다. 본 연구에서 수정된 MIRD팬텀은 기존에 사용되던 선량환산계수의 수정에 사용될 수 있으며 수학적팬텀의 장점을 살리면서 실제 인체에 근접한 선량계산을 수행할 수 있다.

전신 방사선조사를 위한 10MV 선형가속기의 선량측정 (The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation)

  • 안성자;강위생;박승진;남택근;정웅기;나병식
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.225-232
    • /
    • 1994
  • 연구목적 : 전남대학교병원 치료방사선과에서 가동중인 10MV X-ray를 이용하여 전신 방사선 조사에 필요한 기본적인 선량측정자료를 얻고자 하였다. 대상 및 방법 : 환자 전신이 포함될 수 있는 대형조사면을 얻기 위하여 collimator를 완전히 개방하여 조사방향이 수평이 되게 gantry각을 맞추었다. 방사선 선원에서 환자 중심축까지의 거리가 360cm일 때 최대 기하학적 조사면은 $144cm{\times}144cm$이었다. Polystyrene팬텀과 평행평판형 전리함을 이용하여 깊이선량율과 principal 및 diagonal axis에서 측방선량분포를 측정하였다. 또한 1cm두께의 아크릴판을 팬텀의 전면에서 20cm 떨어진 위치에 놓고 표면 선량의 증가와 최대선량점($d_{max}$)의 변화를 측정하였다. SAD 360cm에서 팬텀의 중심에 측정기 위치를 고정시키고 팬텀의 두께를 12cm에서 30cm까지 변화시키면서 MU당 선량율을 측정하였다. 결과 : SSD 345cm, 조사면 크기 $144cm{\times}144cm$의 조건에서 깊이선량율은 10cm 깊이에서 $78.4{\%}$였고, dmax정은 1.8cm이었다. 1cm두께의 아크릴판을 spoiler로 팬텀에서 20cm 띄우고 사용했을 때 dmax점은 1.8cm에서 0.8cm으로 이동하였고, 표면선량은 $61\%$에서 $94\%$로 증가하였다. 평행 2문 조사시 30cm두께의 팬텀에서 선축상 선량분포의 차이는 $7\%$이내였다. $100\%$ 선량점의 선축이탈거리는 principal axis에서 67cm. diagonal axis에서 80cm이었다. 팬텀의 중심에서 측정된 출력계수로 MU당 선량은, (Dose/MU)=$-0.00178{\times}(T/2)+0.08676$ (T:팬텀 두께(Cm))로 표현되는 직선의 관계식을 나타내었다. 결론 : 1)좌우 대향 2문조사 방법으로 30cm두께의 팬텀에 10MV X-ray를 조사하였을 때 선량분포의 차이는 $7\%$이내로 만족스러운 결과를 보였다. 2) 고에너지 광자선으로 전신방사선 조사시 표면선량 증가를 위하여 beam spotter의 사용이 필요할 것으로 사료된다 3) 측방선량분포곡선에서 principal 및 diagonal axis에 따른 선량분포의 차이가 있어 환자 치료시 고려되어야 할 것으로 생각된다 4) 전신방사선조사시 선량분포는 여러 가지 요인에의하여 달라질 수 있기 때문에 직접적인 방법에 의해 측정된 MU당 선량은 깊이와 직선의 관계식을 보여 실제 치료에 적용될 수 있을 것으로 생각된다. 본 연구에서 얻어진 전신 방사선조사에 관한 기본적 선량측정자료는 AAPM보고서 No. 17에서 권장된 범주에 들었으며 향후 임상에 이용될 수 있을 것으로 생각된다.

  • PDF

인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가 (Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom)

  • 장은성;강수만;이철수
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.33-39
    • /
    • 2009
  • 목 적: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하면 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. Detected offsets은 실제로 적용된 인체팬톰(Rando phantom) 위치의 오차와 비교되어 진다. 이후, 인체 팬톰은 detected 오차에 근거하여 couch를 움직여 위치선정 되었다. 또한 인체팬톰 위치 결정의 실측값과 이론값 오차값들을 비교하였으며, OBI를 사용하고 있는 KV X선영상의 2D와 CBCT의 3D 타켓 위치 정확성 평가하고자 한다. 대상 및 방법: 신체 내부 구조가 모사된 팬톰(The Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)을 사용하여 실제방사선 치료와 동일한 과정을 따라 모의치료(SIMULATION) 및 치료계획(RTP)을 시행한 후 치료 데이블 위에 인체 팬톰을 셋업한다. 정확히 위치가 재현된다고 가정되는 인체팬톰에 대해 3가지 방법으로 실험을 했는데 X, Y, Z축의 변화에 따라 셋업 오차를 측정했고 각각의 실험은 10회씩 반복되어 오차의 표준 편차를 구했다. DigiPas DWL-80G는 기울기의 각을 결정하기 위해 사용하였으며, 2D/2D 및 3D/3D정합의 실측치와 측정치를 비교 분석 하였다. 결 과: 온보드 영상장치로 획득한 정면 및 측면 kv x선 영상과 모의치료시 디지털 재구성 기준영상과의 2차원/2차원 정합시, 팬톰의 X, Y, Z 편차 평균값은 lat 0.12 cm, long -0.66 cm, vert 0.07 cm이며, 각도의 변화를 주었을 때 편차의 평균값은 lat -0.5 cm, long -0.3 cm, 팬톰의 몸을 약간 튼 상태에서의 편차 평균값은 각각 lat -0.5 cm, long 0.2 cm, vert -0.6 cm으로 나타났다. 또한 콘빔CT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3차원/3차원 정합에서 팬톰의 3가지 방법에서 편차의 평균 detection error와 표준편차는 lateral $0.5{\pm}0.4\;mm$, longitudinal $0.8{\pm}0.5\;mm$, vertical $0.4{\pm}0.3\;mm$로 각각 0-10 mm의 범위이다. Residual error에 해당되는 positioning couch shift 변수는 $0.6{\pm}0.3\;mm$, $0.5{\pm}0.3\;mm$, $0.3{\pm}0.1\;mm$이다. 20-50 mm까지 longitudinal shift에 의한 평균 detection error는 각각 lateral $0.4{\pm}0.2\;mm$, longitudinal $0.3{\pm}0.2\;mm$, vertical $0.3{\pm}0.3\;mm$이다. Residual error는 $0.6{\pm}0.3\;mm$, $0.6{\pm}0.2\;mm$, $0.4{\pm}0.1\;mm$이다. Detection error는 모두 0.0~0.6 mm 범위이다. Residual error는 0.3~0.9 mm 범위로 나타났다. 결 론: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하여 표적위치의 정확성을 평가하였다. 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. 그러므로 OBI 및 CBCT를 이용한 2D/2D 및 3D/3D 정합은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 할 것으로 평가된다.

  • PDF

심근관류 SPECT에서 움직임 보정 방법들의 비교 (The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT)

  • 박장원;남기표;이동훈;김성환
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.28-32
    • /
    • 2014
  • 심근 관류 SPECT 검사 중 환자의 움직임은 관류 결손과 인공물을 발생시켜 정확한 진단에 영향을 줄 수 있는 인자이다. 움직임으로 왜곡된 데이터를 보정하는 방법으로 움직임 보정방법이 개발되었고 각 방법마다 사용된 알고리즘이 다르기에 상황에 비교하고자 한다. 실험에 사용된 장비는 GE Ventri Gamma Camera와 Anthropomorphic Torso Phantom을 이용하였다. 팬텀을 환자 조건과 동일하게 하기 위하여 심근에 74 kBq/mL, 연부조직 1.1 kBq/mL, 폐 2.6 kBq/mL, 간 9.6 kBq/mL의 Tl-201을 주입하여 제작하고, 움직이는 상황에서 결손의 변화 관찰 목적으로 심근의 Anterior wall에 임의로 결손을 삽입하였다. 움직이지 않는 정상군과 일정간격(2 cm, 3 pixel) 상하 1회 이동, 상하 반복 이동, 좌우 1회 이동, 좌우 반복 이동한 데이터에 나누어 영상 획득하고 MDC, Hopkins, Stasis 방법을 적용하여 Polar map과 정량분석 Score로 비교 하였다. 환자와 동일한 조건으로 회전각 $6^{\circ}$, 50sec/frame으로 영상 획득하고, OSEM (2 iterations, 10 subsets), Butterworth filter (order 10; cutoff frequency; 0.32 cycle per pixel)를 적용, scatter correction, 감쇠보정은 적용하지 않았다. 팬텀 실험에서 세 가지 방법들에서 MDC 방법이 Visual 인공물 없이 잘 보정하였으나, 환자의 데이터에 이를 적용 하였을 때, 환자마다 움직임 보정방법 적용 결과들이 일정하지 않았다. 이는, 환자의 움직임이 일정하지 않고, 장기내의 동위원소의 비율도 다르기에 발생한다고 생각되며 추가적인 연구와 상황에 맞는 움직임 보정방법의 유동적인 사용이 필요하다고 사료된다.

  • PDF