• 제목/요약/키워드: Body part

검색결과 2,924건 처리시간 0.028초

Types of perception on the body shape of the elderly men

  • Cha, Su-Joung
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.129-136
    • /
    • 2019
  • The purpose of this study was to provide basic data necessary for the development of clothing that can improve the satisfaction of body shape of elderly men by examining subjective characteristics and characteristics of perception type of older men's body shape. Using the Q methodology, I investigated and analyzed the process of formation and main characteristics of subjectivity of various types of recognition that elderly men express about their body shape. There were four types of perception of body shape in elderly men: flat hip and bird legs skinny body, back bent and abdominal obese body, thick neck and upper body development body, forward cervical neck and protruding abdomen obese body. The actual body shape of elderly men was classified according to the bust, waist circumference, hip circumference, and body part angle. But recognition body shape of elderly men was classified by visual factors like the abdomen, the angle of the neck, the inclination of the back, the slope of the waist, and the degree of obesity. It is necessary to consider the trend of silver fashion which is increasing in demand. In addition, it is necessary to develop clothing patterns of comfortable fit through ergonomic study on the physical characteristics of older men. Consideration should be given to the design and pattern that can reduce the difference between the ideal body shape and the body shape recognized by older men.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

$\ll$황제내경(黄帝内经)$\gg$ "진액(津液)" 개념고변(概念考辨) (Analysis of the concept of body fluid in "Hwangjenaegyeong(黃帝內經)")

  • 곡봉;김효철
    • 대한한의학원전학회지
    • /
    • 제23권1호
    • /
    • pp.11-13
    • /
    • 2010
  • In this article, the concept of body fluid is explained in three aspects: the word meaning of body fluid, the origins of the definitions of the body fluid concept and the connotation and extension of body fluid. Investigating data about the time Hwangjenaegyeong(黃帝內經) was written, the author discovers that the meaning of "Aek(液)" is clear, but there are still questions about the meaning of "Jin(津)". The concept of body fluid derived from observation of life phenomenon and ancient philosophy on the "water". The concept of body fluid should be expressed as that body fluid is a general term for all normal liquids in the body. Within the meridians, as the composition of blood components; outside the meridians, constituting the intrinsic body fluids of various organs and tissues. This is the main part of body fluid, coming from diet, constituting the human body and maintaining human life activities, playing the roles of moistening and nourishing various of organs and tissues of the body. In addition, Interstitial fluid, all kinds of normal liquid secretion and metabolic products, such as sweat, tears, nasal discharge, saliva, slobber, gastric juice, intestinal fluid, urine, joint fluid, latex and so on, both belong to body fluid.

Types of perception on the body shape of male university students

  • Cha, Su-Joung
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권2호
    • /
    • pp.85-93
    • /
    • 2019
  • The purpose of this study is to provide basic data for the development of clothing which can improve the satisfaction of male university students' body shape by classifying the perception of body shape and examining characteristics by type. The types of recognition of body shape of male college students were classified into five types: developed upper body with protruding under abdomen, normal body with long legs, developed under body with big skeleton, skinny body, and ladder type normal body. The actual body shape was classified into three. The Y type had a long chest length and a shoulder developed, and the lower body silhouette was plain and short. Type H was flat with little protrusion from the chest to the hip. Type X has a larger hip and longer hip length than the waist. Body type was classified based on bust, waist, and hip circumference, but recognition body type was classified based on visual characteristics. It is thought that ergonomic consideration is needed to cover the disadvantages of each body type considering the aesthetic part as well as wearing comfort in accordance with the trend of the fashion market nowadays that the slim fit is generalized. This study was limited to male university students in their early 20s in Chungbuk province. Therefore, we could not grasp attitudes and perceptions of male university students living in other provinces. Therefore, we should pay attention to the generalization of the results of this study.

안정된 동기시신호발생을 이용한 인체 기능의 측정에 관한 연구 (A research on the sychronized clock pulse for the measurement of physical function.)

  • 이행세;이상혁;김용득
    • 대한전자공학회논문지
    • /
    • 제13권5호
    • /
    • pp.9-16
    • /
    • 1976
  • 인체기능 측정장치를 설계한 것으로 체온계를 계수형 계기로 설계보험하였고, 맥박과 혈압측정장치 설계를 위한 기초실험을 하였다. 종래의 복잡한 아날로그식의 변환과정을 모두 제거하고, 온도제어 주파수변환회로를 설계하여, 직접 온도에서 주파수로 A/D 변환을 행하였다. 기온범위에서 ±0.05℃의 오차한계를 얻었다. This paper deals with a method of measuring the temperature, purse, and pressure of a human body The temperature controlled oscillator was designed with a thermistor as a temperature measuring part The error in temperature was less than ±0.05℃ in the range of the temperature of a human body.

  • PDF

상지체표변화에 따른 인간공학적 소매설계에 관한 연구 (A Stydy on the Ergonomic Sleeve Design by Body Surface Changes at Upper Extremity)

  • 최해주
    • 한국의류학회지
    • /
    • 제19권6호
    • /
    • pp.911-923
    • /
    • 1995
  • The zone of expansion and contraction of arm surfaces was analyzed, the correlation between arm surface changes was studied, and ergonomic sleeve designs were presented in which the consideration of body surface changes is emphasized. Experiments were carried out which include 43 upper extremity segments, 21 motions and 35 female subjects. The major conclusions of the study are as follows : 1. As a sleeve drafting method, detailed measures should be applied on the base of the sensitivity of body surface changes. The range of arm surface changes can be divided into three zones : concentrated expansion zone, zone of little change, and contraction part. The maximum expansion zone was the upper part of elbow. 2. The correlations were higher in lengths than in circumferences. Arm lengths were mainly correlated with upper arms. The more detailed the arm surface was, the lower the correlations between surface changes were. So there was not a lot of relation between segment changes. Tendency of body surface changes depended on the anatomical structure of the upper extremity and the movements of arm muscles. 3. As an application of measures and ease, ergonomic sleeve designs weve presented in which arm surface changes were considered. Ergonomic sleeve designs are recommended for working clothes and sports wear.

  • PDF

한증(汗症)에 대(對)한 동.서의학적(東.西醫學的) 비교(比較) (A comparative study of the oriental and the Occidental medical literature on the symptoms of sweat)

  • 김현;오태환;정승기;이형구
    • 대한한방내과학회지
    • /
    • 제12권2호
    • /
    • pp.52-58
    • /
    • 1991
  • Review of literature on the symptoms of sweat. According to comparative studies of oriental and occidental medical literature on the symptoms of sweat, following results were obtained. 1. oriental medicine 1) time: ja han (自汗), do han (盜汗) 2) body : du han (頭汗), su jog han (手足汗), sim han (心汗), eum ban (陰汗) pyun hang (偏汗) 3) kan (肝) : hwang han (黃汗), sim(心) : sin han (心汗), hyul han(血汗), bee (脾) : sig hu han (腎虛汗) sin(腎) : eum han (陰汗) By the study of the oriental medical literature, sweat were concerned with physiological function and pathological transformation of the body, 2. occidental medicine 1) NO sweat of the whole body 2) NO sweat of the part 3) much sweat of the whole body, 4) much sweat of the part. By the study of the western medical literature, sweats were tiny reaction of the· nerve and the mind.

  • PDF

지체장애자(肢體障碍者)의 체형(體刑)에 관한 연구(硏究) - 편마비자(片麻痺者)의 동상부(胴上部)를 중심(中心)으로

  • 손미숙;심부자
    • 복식
    • /
    • 제14권
    • /
    • pp.199-208
    • /
    • 1990
  • In order to eximine the body form of the physically handicapped people, the 11 items of angle, 54 items of size and weight of the subjects were measured body silhouetter photographs and with the Martin's anthrophometeric instrument respectively. The subjects were consist of 37 boy students who are 13-19 years old and hemiplegias caused by cerebral palsy. And then the comparison between normal and paralysis sides, analysis of somatotypes with the body silhouetter photographs, ANOVA for effect of somatotype on measuring items for angles, and factor analysis for all items were carried out. The results were as follows: 1. The results of measuring are difference between normal and paralysis sides. 2. The items shown significant differences between normal and paralysis sides are diagonal anterior chest B, scapula length, armscye girth, diagonal posterior chest A, and arc of the bust. 3. The percentage of each somatotype shows the order of bending somatotype, turning over somatotype, turning over-bending somatotype, and standard somatotype in the upper body. There are significant differences between somatotypes and sternalis up, sternalis down, scapula, vertebialis, ${\alpha}$, and ${\beta}$ angles respectively. 4. From the result of factor analysis, front and back sections, length items of the upper part and the lower part from the bust line, and the upper size items at the bottom of armscye were abstracted.

  • PDF

왕복동 압축기의 동특성 분석 및 진동개선에 관한 연구 (A Study on Dynamic Characteristics of Reciprocating Compressors)

  • 고병승;황원걸;안기원;박성우;서문희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.478-485
    • /
    • 2003
  • Today, although there have been high technical developments of a compressor in the respect of its capacity, it has been so hard to develop in the respect of vibration and noise because mechanical structure of it has originally numerous vibration and noise. However, if we can grasp the point of systematic phenomena of vibration and noise through the understanding of dynamic characteristics in mechanical equipment, it may be possible to consider countermeasures. In this study about a reciprocal compressor, the part of its machinery is modeled as rigid body, and the part of its spring is modeled as flexible body, and then they are analyzed by DADS. Each rigid body and spring are connected with joint torque of a motor is applied to shaft, and pressure is applied to a piston so that a compressor can be revolved. Based on this modeling, influence of a compressor's vibration is analyzed through changes of offset, connecting rod and crank radius In the case of weight balance, it I produced after re-design, and then changes of vibration of a compressor's inside are checked through experiments. These analysis data may help set measures of reducing vibration of a reciprocal compressor.

  • PDF

석고법에 의한 남성 상반신 체표면변화에 관한 피복인간공학적 연구 (A Study on the Upper Part of the Body Form Variation According to Arm Movements for Male by Plater Gypsum Experiments)

  • 김미경
    • 대한가정학회지
    • /
    • 제30권3호
    • /
    • pp.63-77
    • /
    • 1992
  • The purpose of this study is to improve clothing construction by analyzing form variation of upper trunk & upper arms with the use of plaster cast. Experimental research was performed by plaster gypsum method. The subjects were males between age 21 and 25, classified Standard somatotype by their bust size and Rorher Index. Arm movements were consisted of 5 types(0$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$, 135$^{\circ}$, 180$^{\circ}$) to each vertical motion in front. The statistical analyses used in this study were mean, standard deviation, repeated mesure design. The result obtained from this study were as follows; 1. As a result of investigating into the rate of the expantion and contraction of basic body-surfact-lines, the side seam length showed the maxium rate of expantion in 180$^{\circ}$ degrees, the shoulder length showed the maxium contraction in the same degrees. 2. The variation of the upper part of the body form by increasing the upper limb motions, shoulder point was moved to be the inside or upside. And the anterior armfit point, posterior armfit point and armfit point were moved to upside. The form of the armhole-line in Drafts of a body surface was differently changed by increasing the movements. 3. Increasing the upper limb motions, the height of sleeve cap decresed and width of the sleeve decreased but girths of the sleeve cap was not show consistant change.

  • PDF