• Title/Summary/Keyword: Body motion

Search Result 2,119, Processing Time 0.028 seconds

Evaluation of Electrohydraulic Left Ventricular Assist Device through Animal Experiment (동물실험을 통한 전기유압식 좌심실 보조장치의 성능 평가)

  • Choi, J.S.;Chung, C.I.;Choi, W.W.;Park, S.K.;Jo, Y.H.;Om, K.S.;Lee, J.J.;Won, Y.S.;Kim, H.C.;Kim, W.G.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.84-87
    • /
    • 1996
  • We have been developed electrohydraulic left ventricular assist device and done various in vivo evaluation on the device. Through the in vivo experiment conducted from Jan. 23, 1996 to Feb. 8, we could have experience of long-term evaluation fur the first time. The sheep used in this experiment had survived for 16 days. We used new actuator with reduced size and linear motion guide replacing oil box and ball bearings. Also, we used improved blood chamber with reduced size, reduced weight facilitating fixing the chamber to animal's body, and polymer sac having improved folding pattern. Against suction problem, we used absolute pressure limiter only. Motor current for driving this new actuator was not much higher than older one. Effective stroke volume was about 48 cc. Thrombosis was found around top area and peripheral boundary of the sac and valves. There was no sign of damage from suction problem in the atrium observed at autopsy. Main cause of death was presumed to be progressive formation of thrombosis in the cannulae. In this paper, the results of this experiment are documented.

  • PDF

The Earth-Moon Transfer Trajectory Design and Analysis using Intermediate Loop Orbits (중개궤도를 이용한 지구-달 천이궤적의 설계 및 분석)

  • Song, Young-Joo;Woo, Jin;Park, Sang-Young;Choi, Kyu-Hong;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.2
    • /
    • pp.171-186
    • /
    • 2009
  • Various Earth-Moon transfer trajectories are designed and analyzed to prepare the future Korea's Lunar missions. Minimum fuel trajectory solutions are obtained for the departure year of 2017, 2020, 2022, and every required mission phases are analyzed from Earth departure to the final lunar mission orbit. N-body equations of motion are formulated which include the gravitational effect of the Sun, Earth and Moon. In addition, accelerations due to geopotential harmonics, Lunar J2 and solar radiation pressures are considered. Impulsive high thrust is assumed as the main thrusting method of spacecraft with launcher capability of KSLV-2 which is planned to be developed. For the method of injecting a spacecraft into a trans Lunar trajectory, both direct shooting from circular parking orbit and shooting from the multiple elliptical intermediate orbits are adapted, and their design results are compared and analyzed. In addition, spacecraft's visibility from Deajeon ground station are constrained to see how they affect the magnitude of TLI(Trans Lunar Injection) maneuver. The results presented in this paper includes launch opportunities, required optimal maneuver characteristics for each mission phase as well as the trajectory characteristics and numerous related parameters. It is confirmed that the final mass of Korean lunar explorer strongly depends onto the initial parking orbit's altitude and launcher's capability, rather than mission start time.

Fracture and Hygrothermal Effects in Composite Materials (복합재의 파괴와 hygrothermal 효과에 관한 연구)

  • Kook-Chan Ahn;Nam-Kyung Kim
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.143-150
    • /
    • 1996
  • This is an explicit-Implicit, finite element analysis for linear as well as nonlinear hygrothermal stress problems. Additional features, such as moisture diffusion equation, crack element and virtual crack extension(VCE ) method for evaluating J-integral are implemented in this program. The Linear Elastic Fracture Mechanics(LEFM) Theory is employed to estimate the crack driving force under the transient condition for and existing crack. Pores in materials are assumed to be saturated with moisture in the liquid form at the room temperature, which may vaporize as the temperature increases. The vaporization effects on the crack driving force are also studied. The Ideal gas equation is employed to estimate the thermodynamic pressure due to vaporization at each time step after solving basic nodal values. A set of field equations governing the time dependent response of porous media are derived from balance laws based on the mixture theory Darcy's law Is assumed for the fluid flow through the porous media. Perzyna's viscoplastic model incorporating the Von-Mises yield criterion are implemented. The Green-Naghdi stress rate is used for the invariant of stress tensor under superposed rigid body motion. Isotropic elements are used for the spatial discretization and an iterative scheme based on the full newton-Raphson method is used for solving the nonlinear governing equations.

  • PDF

3-D Kinematic Analysis According to Open Stance Patterns During Forehand Stroke in Tennis (테니스 포핸드 스트로크 동안 오픈스탠스 조건에 따른 3차원 운동학적 분석)

  • Choi, Ji-Young;Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.161-173
    • /
    • 2005
  • Recently among several tennis techniques forehand stroke has been greatly changed in the aspect of spin, grip and stance. The most fundamental factor among the three factors is the stance which consists of open, square and closed stance. The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle according to open stance patterns during forehand stroke in tennis. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVlEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and racket head angle were defined 1. In three dimensional maximum linear velocity of racket head the X axis showed $11.41{\pm}5.27m/s$ at impact, not the Y axis(horizontal direction) and the z axis(vertical direction) maximum linear velocity of racket head did not show at impact but after impact this will resulted influence upon hitting ball It could be suggest that Y axis velocity of racket head influence on ball direction and z axis velocity influence on ball spin after impact. the stance distance between right foot and left foot was mean $74.2{\pm}11.2m$. 2. The three dimensional anatomical angular displacement of shoulder joint showed most important role in forehand stroke. and is followed by wrist joints, in addition the movement of elbow joints showed least to the stroke. The three dimensional anatomical angular displacement of racket increased flexion/abduction angle until the impact. after impact, The angular displacement of racket changed motion direction as extension/adduction. 3. The three dimensional anatomical angular displacement of trunk in flexion-extension showed extension all around the forehand stroke. The angular displacement of trunk in adduction-abduction showed abduction at the backswing top and adduction around impact. while there is no significant internal-external rotation 4. The three dimensional anatomical angular displacement of hip joint and knee joint increased extension angle after minimum of knee joint angle in the forehand stroke, The three dimensional anatomical angular displacement of ankle joint showed plantar flexion, internal rotation and eversion in forehand stroke. it could be suggest that the plantar pressure of open stance during forehand stroke would be distributed more largely to the fore foot. and lateral side.

How Does Smart Device User Experience Change by Generation (스마트 디바이스의 세대별 사용자 경험 변화 연구)

  • Lee, Hyun-Ju;Hong, Mi-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.252-260
    • /
    • 2019
  • Smart devices have penetrated deeply into our daily lives. They have not only increased user convenience, but also changed the overall lifestyle of society. The objective of this study was to examine the change process of user experience through device classification and technology by generation. In order to achieve the objective, this study analyzed the purpose and pattern of using a device, which is a digital platform, and the input and output, which are the most important digital components for personal exclusiveness and interaction. The analysis results of this study showed that, in the past, the purpose of using a device was clear, a device was used in common, and a separate device was used for input and output. However, as devices evolved, users began to emphasize the fun aspect than the purpose of a device. As a result, personal exclusiveness has increased. Moreover, unlike devices in the past depending on separate input or output methods, devices are evolving to employ a method performing input and output using the five senses of people such as the touchscreen using a body part of a user, voice, and motion. This study evaluated how the overall experience of users, which was obtained through technology, has changed for each generation. Furthermore, this study proposed the future direction of device development by considering the user experience. It is believed that the results of this study will be useful for future studies on the overall experience of users who will use a range of smart devices, which will be released in the future.

Biomechanical Analysis of Lower Limb on Stance during Golf Swing (골프 스윙 시 스탠스에 따른 하지의 역학적 분석)

  • Yoon, Se-Jin;Sul, Jeong-Dug;Woo, Byung-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.532-542
    • /
    • 2021
  • The purpose of this study was to investigate the body's strategy through kinematic variables of the lower extremities and ground reaction forces to maintain the club-head speed and ball accuracy despite the three stances during the golf swing. Ten male golfers who official handicap two were participate in the experiment. All subjects performed swing after maintaining the address posture according to stance conditions(square; SS, open: OS, closed: CS). Using a 3D motion analysis system and force plateform, the results were calculated with the 7-iron full swing each stance. In result, there was no difference in center of displacement, and left and right hip and knee joint angle displacement. Left ankle joint was largely plantar-flexed in OS, and right ankle joint was largely performed in CS from the address to the downswing. From address to take-back, right foot had a large left direction and the left foot had a right direction were greater in OS than in CS. Therefore, despite various stances, maintaining the same posture at impact is thought to have a positive effect on club head speed and ball direction.

Effects of visual selection and rotation order on take-off and landing during sequential rotational jumping (연속 회전점프 시 시각선택과 회전순서가 도약과 착지에 미치는 영향)

  • Woo, Byung-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.5
    • /
    • pp.701-709
    • /
    • 2022
  • The purpose of this study was to compare the differences according to the visual selection and rotation order during sequential rotational jump for female dancers of a Korean ballet company by classifying them into take-off and landing sections. 10 subjects (age: 26.0±2.9 yrs, height: 163.4±3.3 cm, weight: 46.8±3.6 kg, ballet career: 12.3±5.9 yrs) participated in the study. Using a 3D motion analyzer and a force platform, the height of the body center and the ground reaction force during take-off and landing were measured. According to the visual condition (using both eyes, using left eye, using right eye) and rotation order (first rotation, second rotation), it was analyzed through repeated measurement two-way analysis. Height of the CM was higher in the first jump. In take-off, Fx was lateral force of left foot and medial force of right foot were strong in second rotation, and Fy was forward force was strong in first rotation of right foot. Fz was no significant. In landing, Fy showed backward force was strong when landing the second time from the left foot, and the backward force was strong when using the left sight from the right foot. Fz was strong on the second landing on the left foot and the first landing on the right foot.

Effect of Mechanical Thermal Massage Inducing Gradual Spinal Segmentation on the Improvement of Pain (단계적 척추 분절운동을 유도하는 기계식 온열 마사지가 통증 개선에 미치는 영향)

  • Hyeun-Woo, Choi;Do-Hyun, Ahn;Kyung-Mi, Jung;Na-Young, Kim;Ji-Eun, Lee;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.879-887
    • /
    • 2022
  • In this study, we tried to confirm whether the mechanical sequential elevation method of the body pressure measuring bed actually induces segmental motion for each part of the spine. To this end, a lateral X-ray examination was performed, and it was confirmed that the sequential pressure device induces a step-wise segmentation of the spine by mechanically lifting each part of the spine vertically. Then, pain, walking ability, and depression scale were measured and analyzed in subjects who were aware of back pain. VAS(p<0.05) and ODI(p<0.05) for 10 days tended to decrease in average after bed use. In the gait ability test(p<0.05), as the number of times of bed use increased, the moving time in the test decreased and the moving distance increased. In addition, GSDDF(p<0.05) decreased after bed use. As a result, it was confirmed that the spinal segmentation caused by the heat and acupressure provided by the bed affected gait and depression as well as pain relief.

A Physiotherapy Program for Adolescent Baseball Players with Scapular Dyskinesis: Comparison of the effects of posterior shoulder stretching combined with scapular stabilization exercises (PSSE) (어깨뼈 운동 이상증을 가진 청소년기 야구선수들을 위한 물리치료적 프로그램: 어깨뼈 안정화 운동과 동반된 뒤쪽 어깨 스트레칭(PSSE) 중재 후 효과 비교)

  • Keon-Cheol, Lee;Hyeon-Su Kim;Yeon-Ki Choo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.1
    • /
    • pp.139-150
    • /
    • 2024
  • Purpose : Scapular dyskinesis, it have been shown to be common in overhead athletes and has been associated with RC muscle strength. Posterior shoulder tightness (PST) has been suggested as an important factor causing scapular dyskinesis. Therefore, rehabilitation programs should focus on a posterior shoulder stretch combined with scapular stabilization exercise (PSSE) intervention. Determine the effects of posterior shoulder stretch combined with scapular stabilization exercise on the rotator cuff (RC) muscles strength, functional strength ratio (FSR), range of motion (ROM), and pain. Methods : 30 adolescent baseball players participated and subjects were allocated PSSE group (n=15) or the SSE group (n=15). Both group performed a 6-weeks intervention and measured of isokinetic peak torque/body weight (PT/BW) of concentric external rotator (CER), eccentric external rotator (EER), concentric internal rotator (CIR), eccentric internal rotator (EIR), FSR, ROM, and pain. Results : After 6 weeks PSSE, significant increase CER PT/BW (+6.02±4.76 %), EER PT/BW (+5.39±4.22 %), EER to CIR ratio (+.17±.16), and internal rotation ROM (+15.08±3.57 °). Whereas, significant decrease EIR to CER ratio (-.14±.18), external rotation ROM (-12.00±6.94 °), and GIRD (-17.41±2.84 °) compared with pre-intervention. No significant difference of isokinetic PT/BW of CIR and EER post-intervention. In the SSE group showed no significant difference all measurements for isokinetic PT/BW, FSR, and ROM post-intervention. The pain was significant improve both PSSE group (-3.25±1.60) and SSE group (-2.83±1.85) post-intervention. Conclusion : Both the PSSE and SSE interventions led to more pain relief. However, only the PSSE group showed ROM, CER, EER PT/BW, and FSR improvements. These results might suggest that the PSSE intervention is a more effective program for improving RC muscle strength and balance, in particular, concentric and eccentric ER muscle strength, FSR and can expect to prevent shoulder injuries in adolescent baseball players with scapular dyskinesis.

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF