• 제목/요약/키워드: Body Pressure

검색결과 2,806건 처리시간 0.038초

Brassiere 착용조건에 따른 신체의 형태적, 생리적 변화에 관한 심리적 연구 (A Experimental Study on the Formal and Physiological Change of Body according to the Wearing-Brassiere Condition.)

  • 박영득
    • 대한가정학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 1991
  • This study was carried out to investigate the influence of the various physiological function caused by brassiere wearing. The four experimental methods used in this study are as follows. For example, the Roentgen photographing, Body measurement by Sliding Gauge, the measurement of the Electrocardiogram and Blood Pressure. The results of the Electrocardiogram and Blood Pressure. The results of the investigation were as follows: 1. In experimental change by Sliding Gauge and Body measurement, The bust point was rised in order AB1>B2. The width of right and left bust point was decreased in order of A>B1>B2. According to, The supplementary effect of brassiere wearing was excellent in B2. 2. In the change of various organs by Roentgen photographing, The width of the chest and size of the heart were decreased in regular order of A>B1>B2. The diaphragm and the others were not showed change. 3. In the experimental result by measurement of the electrocardiogram, The interval of heart palpitation was decreased in order A>B1>B2 and the pulse frequency was similar. 4. In the experimental result by the blood pressure measurement, A had the highest blood pressure and B2 had the lowest pressure in all variables.

  • PDF

동적 하네스 체중지지율에 따른 일상생활 동작 시 인체영향평가 (Evaluation of Human Body Effects during Activities of Daily Living According to Body Weight Support Rate with Active Harness System)

  • 송성미;유창호;김경;김재준;송원경;홍철운;권대규
    • 재활복지공학회논문지
    • /
    • 제10권1호
    • /
    • pp.47-57
    • /
    • 2016
  • 본 연구에서는 다자유도 동적 하네스 시스템을 개발하고 동적 하네스 체중지지에 따른 인체 영향평가를 하고자 한다. 건강한 성인 남성 20명을 대상으로 실험을 진행하였으며 평지보행, 앉기, 서기, 계단 오르기, 계단 내려오기 5가지 일상생활 동작을 수행하였다. 일상생활 동작 수행 시 각 피험자 체중의 0%, 30%, 50%에서의 근육 활성도와 족압 분포를 측정하였다. 근육 측정부위는 대퇴직근, 대퇴이두근, 전경골근, 외측 비복근이다. 하네스 체중지지율 증가에 따라 족압의 평균값은 전체적으로 감소하는 경향을 보였다. 평지보행에서는 체중지지율 증가에 따른 전족부의 압력의 감소폭이 크게 나타났으며 비복근과 대퇴이두근의 활성 감소를 보였다. 앉기 동작에서는 후족부의 족저 압력 감소폭이 크게 나타났으며 체중지지율에 따라 전경골근의 근육 활성이 감소하였다. 계단 내려오기 동작에서는 체중지지율 증가에 따라 전족부의 압력이 크게 감소하였고 대퇴직근의 활성감소가 크게 나타났다. 의자에서 일어나기동작과 계단 오르기 동작에서는 동적 하네스 체중지지효과가 미비하였으며 이는 속도가 건강한 성인 남성의 동작 수행 속도보다 느리기 때문이다. 후속 연구에서는 본 시스템을 개선하기 위한 연구가 지속되어져야 할 것이다.

비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화 (Changes in Physiological Responses by the Pressure of Non-Elastic Corset)

  • 나영주;김양희
    • 한국의류산업학회지
    • /
    • 제13권6호
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.

PTTL을 이용한 수축기 혈압추정 (Estimation of Systolic Blood Pressure using PTTL)

  • 길세기;권장우;윤광섭;이상민
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1095-1101
    • /
    • 2008
  • The desirable method to diagnose abnormal blood pressure is to measure and manage blood pressure continuously and regularly. However, the sphygmomanometers that are based on a cuff have faults in that they can not measure the blood pressure continuously and they cause an unpleasant feeling. Therefore, it is essential to develop a new measuring method that causes no pain and that can obtain blood pressure continuously without any unpleasant feeling. Thus, we propose here a regression method to estimate the systolic blood pressure by using the PTTL(pulse transit time on leg) with some body parameters which are chosen from the relational analysis with systolic blood pressure. The data we use to make the regression model were obtained in triplicate from each of 50 males who were from 18 to 35 years. And we made estimation experiments of blood pressure on 10 males who did not take part in the making the regression model. According to the results, the proposed method showed a mean error of 4.00 mmHg and the standard variance was 2.45 mmHg. When we comparing the results of the proposed method with the rule of American National Standards Institute of the Association of the Advancement of Medical Instruments(ANSI/AAMI), the results satisfied the rule of a mean error less than 5 mmHg and a standard variance less than 8 mmHg. Therefore we were able to validate the usefulness of the proposed method.

통합보존식 해석과 HCIB 법을 이용한 슬로싱 탱크 내부 갇힌 공기에 의한 압력 진동 모사 (Simulation of a Pulsating Air Pocket in a Sloshing Tank Using Unified Conservation Laws and HCIB Method)

  • 신상묵
    • 대한조선학회논문집
    • /
    • 제58권5호
    • /
    • pp.271-280
    • /
    • 2021
  • The code developed using a pressure-based method for unified conservation laws of incompressible/compressible fluids is expanded to handle moving or deforming body boundaries using the hybrid Cartesian/immersed boundary method. An instantaneous pressure field is calculated from a pressure Poisson equation for the whole fluid domain, including the compressible gas region. The polytropic gas is assumed for the compressible fluid so that the energy equation is decoupled. Immersed boundary nodes are identified based on edges crossing body boundaries. The velocity vector is reconstructed at the immersed boundary node using an interpolation along the assigned local normal line. The developed code is validated by comparing the time histories of pressure and wave elevation for sloshing in a rectangular and a membrane-type tank. The validated code is applied to simulate air cushion effects in a rectangular tank under sway motion. Time variations of pressure fields are analyzed in detail as the air pocket pulsates. It is shown that the contraction and expansion of the air pocket dominate the pressure loads on the wall of the tank. The present results are in good agreement with other experimental and computational results for the amplitude and the decay of the pressure oscillations measured at the pressure gauges.

보건소 중년 여성 비만관리 프로그램의 운영에 따른 체성분, 건강 상태 및 식행동 변화에 관한 연구 (Changes in Body Composition, Health Status, and Dietary Behavior for Middle-Aged Obese Women in a Weight Control Program at a Community Health Center)

  • 이병순
    • 한국식품영양학회지
    • /
    • 제20권4호
    • /
    • pp.433-439
    • /
    • 2007
  • The purpose of this study was to evaluate the body composition, health status, and dietary behaviors of middle-aged women in a weight control program at a community health center. The study subjects were 66 middle-aged women who lived in Ansan city, and they participated in the program for 24 weeks. Anthropometries, blood pressure, and serum biochemical indices were measured. These measurements were taken both before and after the weight control program, and the data were analyzed using the SPSS 12.0 program. Weight, fat mass, body fat %, and the waist-hip ratio all decreased. According to the decreases in body fat %, blood pressure, serum biochemical indices and dietary behaviors were improved after the weight control program. Thus, this study demonstrated the desirable changes of a weight control program offered at a community health center, for health conditions and physical fitness.

뇌파를 이용한 허리 압박감 평가 기술 (Evaluation of Waist Pressure Using Electroencephalogram(EEG) Signal)

  • 김동준;우승진
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1190-1195
    • /
    • 2011
  • This paper presents a waist pressure evaluation method in human sensibility using a electroencephalogram(EEG) signal. For this objective, a size-controllable waist-belt is used. First of all, EEG signals for relaxed state are acquired. Then, the waist-belt of the subject is tightened about 90% of normal state. After a few minutes, the belt of the subject is released. Some necessary preprocessing is performed on the acquired signals, Linear Prediction (LP) coefficients are utilized as the feature parameters extracting the characteristics of EEG signal, and a multi-layer neural network is used for indicating the state of body pressure. The results of the method showed 77.2% of coincidence with body pressure states. This may be compromising results for ssubject-independent sensibility evaluation using EEG signal.

다중 OWC챔버 구조물의 운동해석 (A Study on the Multiple OWC Chamber Motion in Waves)

  • 홍도천;홍사영;홍석원
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.202-205
    • /
    • 2002
  • The motion of a floating body with multiple owe chambers in waves is studied taking account of fluctuating air pressure in the chambers. The atmospheric pressure drop in one chamber is interrelated with the drop in the other chamber. Velocity potential in the water due to the free surface oscillating pressure patches is calculated by making use of the hybrid Green integral equation. The chamber motion in the frequency domain is calculated for various values of parameters related to the atmospheric pressure drop in the multiple chambers.

  • PDF

맥진연구를 위한 심혈관계 시뮬레이터의 개발 (Development of the Cardiovascular Simulator for Pulse Diagnosis Study)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제16권1호
    • /
    • pp.19-26
    • /
    • 2012
  • Objectives The aim of this study is to develop a cardiovascular simulator that can reproduce blood pressure pulse and blood flow similar to those of the human body. Methods In order to design a system similar to the human cardiovascular system, the required performances were determined by investigating the hemodynamic characteristics of the heart and the arterial system. Main organ to be imitated is heart in simulator. The rest of the system was minimally designed. Also, a blood pressure and blood flow measurement system was developed for measuring the results. Results The developed system showed blood pressure pulse at similar range of the human aorta. The result waveform include primary wave caused by ventricular systole except reflected wave. Conclusions The blood pressure and blow flow patterns were replicated by the simulator. These patterns were similar to those of the human body. The system will play an important role in studying pulse diagnostics.

자유수면에 낙하하는 물체의 형상각에 관한 실험적 연구 (An Experimental Study on the Deadrise Angle of a Falling Body upon a Free Surface Water)

  • 이종붕;이주용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.223-228
    • /
    • 2001
  • This study was obtained the pressure distribution of a falling body that is deadrise angle $0^{\circ}$ and deadrise angle $5^{\circ}$ upon a water surface by the experiment with the impact machine. The theoretical equation was obtained the air region and the interface and the water region which devide 3 parties between the body and the water surface for an investigation of the complete phenomena. Pressure distributions and histories compare favorably with available experimental data. The numerical results are similar to the experimental results for the impact force type with $Fo(1+cos{\pi}t/tc)$.

  • PDF