• Title/Summary/Keyword: Bm60

Search Result 150, Processing Time 0.026 seconds

Integrated Transceiver Module development at Ka-Band (Ka-Band의 집적화된 송수신 모듈 개발)

  • Kim, Wan-Sik;Jung, Yun-Man;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.5 s.43
    • /
    • pp.267-272
    • /
    • 2006
  • In this paper, an integrated and small Ka-band transceiver module has been developed for measuring distance at the radar systems. Oscillator of cavity type, The MMIC such as VCO, power amplifier, LNA, and mixer, and passive components are integrated on carriers and these are assembled in the transceiver module directly. The test result shows the output power of 21dBm and the noise figure of 5dB using developed transceiver module. Using developed FMCW transceiver module. We can measure the 60m range target by detecting the beat frequency and distinguish both earth and sky using radiometer signal. So we defined that the integrated module using MMIC had a good performance for the radar and radiometer at Ka-band.

  • PDF

The Design and Implementation of MCPA for IMT-2000 using Feedforward Linearization (Feedforward 선형화 기법을 이용한 IMT-2000용 MCPA의 설계 및 제작)

  • 노상연;정성찬;정종한;박명석;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.99-106
    • /
    • 2001
  • In this paper, an 1-Watt amplifier for IMT-2000 was designed and fabricated using feedfarward method which has the highest linearity and wide bandwidth. Since feedforward is sensitive to surroundings for example heat, input power level, time and so on, adaptive controller using micro controller is adopted. We fabricated a HPA with 35 dB gain, 40 dBm of 1-dB compression point, and utilized variable attenuator and variable phase shifter using reflection type to cancel loop signal. From the measured results, the fo11owing facts were obtained, in signal loop, main carrier over 35 dB was suppressed and error signal over 30 dB is cancelled in error loop, IMD characteristics above 60 dBc were obtained.

  • PDF

Design and fabrication of test equipment of RF Telecommand and Telemetry for satellite control (위성 제어용 RF Telecommand 및 Telemetry 시험 장비 설계 및 제작)

  • Chang, Lae-Kyu;Jo, Seong-Won;Lee, Hyung-Goo;Hong, Sung-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.187-192
    • /
    • 2009
  • Telecommand & telemetry control equipment is needed for the testing of the transponders during the development of satellite. This equipment must have a loopback function to perform the self testing without satellite. The fabrication of the designed system is easier and cheaper than the conventional testing system using direct modulation method. The measured results of fabricated equipment are satisfied with required specifications. A overall path loss of uplink and downlink is 47.8 dB and 42.6 dB, respectively. Also, IMD3 of uplink has measured 60.68 dBc at an output of -50 dBm.

High Power W-band Power Amplifier using GaN/Si-based 60nm process (GaN/Si 기반 60nm 공정을 이용한 고출력 W대역 전력증폭기)

  • Hwang, Ji-Hye;Kim, Ki-Jin;Kim, Wan-Sik;Han, Jae-Sub;Kim, Min-Gi;Kang, Bong-Mo;Kim, Ki-chul;Choi, Jeung-Won;Park, Ju-man
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.67-72
    • /
    • 2022
  • This study presents the design of power amplifier (PA) in 60 nm GaN/Si HEMT technology. A customized transistor model enables the designing circuits operating at W-band. The all matching network of the PA was composed of equivalent transformer circuit to reduce matching loss. And then, equivalent transformer is several advantages without any additional inductive devices so that a wideband power characteristic can be achieved. The designed die area is 3900 ㎛ × 2300 ㎛. The designed results at center frequency achieved the small signal gain of 15.9 dB, the saturated output power (Psat) of 29.9 dBm, and the power added efficiency (PAE) of 24.2% at the supply voltage of 12 V.

W-Band Power Amplifier with Hybrid Bias Network Using 60-nm GaN pHMET Process (하이브리드 바이어스 네트워크가 적용된 W대역 60-nm GaN pHEMT 전력 증폭기)

  • Yoo, Jinho;Lee, Jaeyong;Jang, Seongjin;Jung, Hayeon;Kim, Kichul;Choi, Jeung Won;Park, Juman;Park, Changkun
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.77-82
    • /
    • 2022
  • The effect of the bias network on the performance of the W-band power amplifier(PA) was investigated. The performances of the typical RC and radial stub networks were examined, and a hybrid network was proposed for W-band application and its performance was confirmed. To verify this, a W-band PA was designed using a 60-nm GaN pHEMT process. When hybrid networks were applied, the PA had improved stability in all frequency bands, secured about 9 dB of power gain at operating frequencies 87 GHz to 93 GHz, and the maximum PAE was found to be about 12.3% at output power of 26.7 dBm.

Single-bias GaAs MMIC single-ended mixer for cellular phone application (Cellular phone용 단일 전원 MMIC single-ended 주파수 혼합기 개발)

  • 강현일;이상은;오재응;오승건;곽명현;마동성
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.14-23
    • /
    • 1997
  • An MMIC downconverting mixer for cellular phone application has been successfully developed using an MMIC process including $1 \mu\textrm{m}$ ion implanted gaAs MESFET and passive lumped elements consisting of spiral inductor, $Si_3N_4$ MIM capacitor and NiCr resistor. The configuration of the mixer presented in this paper is single-ended dual-gate FET mixer with common-source self-bias circuits for single power supply operation. The dimension of the fabricated circuit is $1.4 mm \times 1.03 mm $ including all input matching circuits and a mixing circuit. The conversion gian and noise figure of the mixer at LO powr of 0 dBm are 5.5dB and 19dB, respectively. The two-tone IM3 characteristics are also measured, showing -60dBc at RF power of -30dBm. Allisolations between each port show better than 20dB.

  • PDF

Design for Low Cost Optical Node with Wavelength Reconfiguration

  • Lee, Jong-Hyung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.63-68
    • /
    • 2022
  • Two wavelength reconfigurable optical nodes are designed. One for 20km or shorter link length, and the other for up to 60km link length. While the first one requires no dispersion compensation, the latter needs dispersion compensation fiber included in the node, which requires additional optical amplifier to compensate the insertion loss of DCF. We calculate all the optical path losses in both cases using the typical value of optical components in the market to see the feasibility of the designed optical node. The minimum received power in the node is calculated to be -21.5dBm without DCF and -12.5dBm with DCF, respectively. These received powers are above the receiver sensitivity both for OC-48 and OC-192 according to the previous work.

Prognostic factors in breast cancer with extracranial oligometastases and the appropriate role of radiation therapy

  • Yoo, Gyu Sang;Yu, Jeong Il;Park, Won;Huh, Seung Jae;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: To identify prognostic factors for disease progression and survival of patients with extracranial oligometastatic breast cancer (EOMBC), and to investigate the role of radiation therapy (RT) for metastatic lesions. Materials and Methods: We retrospectively reviewed the medical records of 50 patients who had been diagnosed with EOMBC following standard treatment for primary breast cancer initially, and received RT for metastatic lesions, with or without other systemic therapy between January 2004 and December 2008. EOMBC was defined as breast cancer with five or less metastases involving any organs except the brain. All patients had bone metastasis (BM) and seven patients had pulmonary, hepatic, or lymph node metastasis. Median RT dose applied to metastatic lesions was 30 Gy (range, 20 to 60 Gy). Results: The 5-year tumor local control (LC) and 3-year distant progression-free survival (DPFS) rate were 66.1% and 36.8%, respectively. High RT dose (${\geq}50Gy_{10}$) was significantly associated with improved LC. The 5-year overall survival (OS) rate was 49%. Positive hormone receptor status, pathologic nodal stage of primary cancer, solitary BM, and whole-lesion RT (WLRT), defined as RT whose field encompassed entire extent of disease, were associated with better survival. On analysis for subgroup of solitary BM, high RT dose was significantly associated with improved LC and DPFS, shorter metastasis-to-RT interval (${\leq}1month$) with improved DPFS, and WLRT with improved DPFS and OS, respectively. Conclusion: High-dose RT in solitary BM status and WLRT have the potential to improve the progression-free survival and OS of patients with EOMBC.

Design of a Dual-band Class-E Power Amplifier using Metamaterial CRLH Transmission Lines (Metamaterial CRLH 전송선로를 이용한 이중대역 Class-E 전력증폭기 설계)

  • Lim, Sung-Gyu;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.9
    • /
    • pp.54-58
    • /
    • 2011
  • In this paper a dual-band Class-E power amplifier using Composite Right-/Left-Handed transmission lines and PIN diode is proposed. Dual-band operation is achieved by the frequency offset and nonlinear phase slope of CRLH TL for the matching network of power amplifiers. The proposed power amplifier has been realized by using in the input and the output matching network for high power added efficiency. PIN diode has been used to obtain the dual-band of power amplifier. The measured results show that output powers of 42.17 dBm and 41.43 dBm were obtained at 800 MHz and 1900 MHz, respectively. At this frequency, we have obtained the power-added efficiency(PAE) of 67.84 % and 65.31 % in two operation frequencies, respectively.

Applying the bacterial meningitis score in children with cerebrospinal fluid pleocytosis: a single center's experience

  • Lee, Jungpyo;Kwon, Hyeeun;Lee, Joon Soo;Kim, Heung Dong;Kang, Hoon-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.7
    • /
    • pp.251-255
    • /
    • 2015
  • Purpose: The widespread introduction of bacterial conjugate vaccines has decreased the risk of cerebrospinal fluid (CSF) pleocytosis due to bacterial meningitis (BM) in children. However, most patients with CSF pleocytosis are hospitalized and treated with parenteral antibiotics for several days. The bacterial meningitis score (BMS) is a validated multivariate model derived from a pediatric population in the postconjugate vaccine era and has been evaluated in several studies. In the present study, we examined the usefulness of BMS in South Korean patients. Methods: This study included 1,063 patients with CSF pleocytosis aged between 2 months and 18 years. The BMS was calculated for all patients, and the sensitivity and negative predictive value (NPV) of the test were evaluated. Results: Of 1,063 patients, 1,059 (99.6%) had aseptic meningitis (AM). Only four patients (0.4%) had BM. The majority of patients (98%) had a BMS of ${\leq}1$, indicating a diagnosis of AM. The BMS was 0 in 635 patients (60%) and 1 in 405 patients (38%). All four BM patients had a BMS of ${\geq}4$. Conclusion: To our knowledge, this is the first study to investigate the diagnostic strength of the BMS in South Korea. In our study, the BMS showed 100% sensitivity and 100% NPV. Therefore, we believe that the BMS is a good clinical prediction rule to identify children with CSF pleocytosis who are at a risk of BM.