• Title/Summary/Keyword: Blower System

Search Result 251, Processing Time 0.026 seconds

Economic implications of optimal operating conditions in a full-scale continuous intermittent cycle extended aeration system (ICEAS) (실규모 연속유입간헐폭기 공정(ICEAS)에서 최적운전조건이 경제성에 미치는 영향)

  • Yong-jae Jeong;Yun-Seong Choi;Seung-Hwan Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.1
    • /
    • pp.29-38
    • /
    • 2024
  • Wastewater management is increasingly emphasizing economic and environmental sustainability. Traditional methods in sewage treatment plants have significant implications for the environment and the economy due to power and chemical consumption, and sludge generation. To address these challenges, a study was conducted to develop the Intermittent Cycle Extended Aeration System (ICEAS). This approach was implemented as the primary technique in a full-scale wastewater treatment facility, utilizing key operational factors within the standard Sequencing Batch Reactor (SBR) process. The optimal operational approach, identified in this study, was put into practice at the research facility from January 2020 to December 2022. By implementing management strategies within the biological reactor, it was shown that maintaining and reducing chemical quantities, sludge generation, power consumption, and related costs could yield economic benefits. Moreover, adapting operations to influent characteristics and seasonal conditions allowed for efficient blower operation, reducing unnecessary electricity consumption and ensuring proper dissolved oxygen levels. Despite annual increases in influent flow rate and concentration, this study demonstrated the ability to maintain and reduce sludge production, electricity consumption, and chemical usage. Additionally, systematic responses to emergencies and abnormal situations significantly contributed to economic, technical, and environmental benefits.

Modeling of PEM Fuel Cell System-Sensitivity Analysis of System Efficiency with Different Main Operating Parameters of Automotive Fuel Cell System (PEM 연료전지 시스템 모델링-자동차용 연료전지 시스템의 주요 작동 변수 변경에 따른 시스템 효율 민감도 분석)

  • KIM, HAN-SANG;KANG, BYUNGGIL;WON, KWONSANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.5
    • /
    • pp.401-410
    • /
    • 2019
  • The operating conditions greatly impact the efficiency and performance of polymer electrolyte membrane (PEM) fuel cell systems and must be properly managed to ensure better performance and efficiency. In particular, small variations in operating conditions interact with each other and affect the performance and efficiency of PEM fuel cell systems. Thus, a systematic study is needed to understand how small changes in operating conditions affect the system performance and efficiency. In this paper, an automotive fuel cell system (including cell stack and balance of plant [BOP]) with a turbo-blower was modeled using MATLAB/Simulink platform and the sensitivity analyses of main operating parameters were performed using the developed system model. Effects of small variations in four main parameters (stack temperature, cathode air stoichiometry, cathode pressure, and cathode relative humidity) on the system efficiency were investigated. The results show that cathode pressure has the greatest potential impact on the sensitivity of fuel cell system efficiency. It is expected that this study can be used as a basic guidance to understand the importance of achieving accurate control of the fuel cell operating conditions for the robust operation of automotive PEM fuel cell systems.

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.

Development of Chestnut Harvesters for Small Farms (소농을 위한 밤 수확기의 개발)

  • Kang, Whoa-Seug;Guyer, Daniel
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.384-389
    • /
    • 2008
  • Three prototype chestnut harvesters were constructed and evaluated their chestnut collection ability and field efficiency. Air-lock paddle system successfully picked up all loose material, and pick up efficiency was about 56 kg/h. Power required to operate this system was evaluated to be 8.7 kW with an air flow rate of $32.6\;m^3/min$. A radial blade type blower with 0.41 m impeller diameter was considered to be a minimum size for this system. For the auger system, air was sucked into the cylinder as the hinged flat cover began to be opened by the material pushed by the auger, and the empty burrs flew back to the container through the space between auger flights and collected in the bottom of the container. It was considered to add a device to prevent air from flowing back or to use the back flowing air for separation of burrs and nuts inside the container. The venturi system could not pick up chestnuts, as they only carried part way up to the suction hose. Consideration was given to an idea that the venturi could be used as a cleaning and separation mechanism for containers filled with both empty burrs and good nuts. A minimum vacuum of 129 mm wg was required to pick up chestnuts, and the corresponding inlet air velocity was 19.3 m/s. 104 mm of vacuum, which was about 81 % of that required for nuts, was enough to pick up burrs with nuts inside. Also, empty burrs with higher moisture content recorded the same pressure as for the burrs with nuts.

Experimental Study on the Operating Characteristics of an Environmental Control System for Avionic Equipments (항공장비용 환경제어시스템의 운전특성에 관한 실험적 연구)

  • Park, Hyung-Pil;Kang, Hoon;Chi, Yong-Nam;Choi, Hee-Ju;Byeon, Young-Man;Kim, Young-Jin;Oh, Kwang-Yoon;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.809-816
    • /
    • 2010
  • An environmental control system is installed to dissipate the thermal load in avionic equipments that are mounted under an aircraft. The operating characteristics of the system change with variations in the control parameters. In this study, an environmental control system was designed and built using R-124 by adopting a vapor compression cycle. The operating characteristics of this system were observed by varying the control parameters, such as refrigerant charging amount, opening of the expansion device, compressor rotation speed, and blower rotation speed. The effect of the control parameters on the environmental control system was analyzed and an optimum control method was identified.

Design and Application of Harmonic Passive Filter (고조파 수동필터의 설계 및 적용)

  • Jeon, Jeong-Chay;Kim, Jae-Hyun;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5397-5402
    • /
    • 2012
  • Accidents involving electric equipment and economical loss by power quality deterioration related to harmonics show a rising tendency A passive filter is economic and efficient in suppressing harmonics but many engineers and designers are reluctant to install a passive filter to defect harmonics at their power system because of problems such as harmonic amplification and the probability of generating series or parallel resonance with the power system. This work introduces that passive filters will be very available to defeat harmonic problems of the power system if passive filters are well designed. We describe method and process of harmonic passive filter design. And the passive filter for the power system having harmonic problems due to use of nonlinear loads like as 100HP DC motor system, an extruding machine, an air blower and other loads are designed. Experimental results verify the performance of the passive filter designed by the described method and procedure.

A study on development of 1kW SOFC test system (1kW급 연료전지 평가시스템 개발에 관한 연구)

  • Hwang, Hyun Suk;Lee, Sanghoon;Lee, Juyoung
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.24-27
    • /
    • 2016
  • In this study, a 1kW Solid Oxide Fuel Cell(SOFC) test system was developed. A SOFC is the most promising power system to provide the higher efficient(over 50%) for house application area(1~10kW). To develop the optimized test system, the temperature control module that controls the preprocess and reaction condition, the flow control module that controls of the mass of reactants, and the electric loader that tests the discharge performance condition, etc. The temperature control module was designed to provide the high control resolution(under $1^{\circ}C$ at $750^{\circ}C$ of operating temperature) using K-type thermal couple. The flow control module was designed control blower and heater precisely using the phase control method. And the electric loader is designed that provide CV, CC, CR discharge mode and minimized the operating error adopting the independent DC-DC converter on analog input and output module. The performance of the developed SOFC test system showed that the accuracy of stack voltage was 0.15% at 80V and stack current was 0.1% at 100A.

Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant (발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측)

  • Jin, Kyung-Yong;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • This study presents prediction of maximum fly ash conveying capacity of fly ash system in a power plant. The mixture ratio and pressure drop characteristics of air-fly ash flow in piping system are not well understood due to the complexity of particle motion mechanism. In this paper, the researcher investigated the optimum mixture ratio when the pressure drop of fly ash conveying system is equal to maximum static pressure of displacement fly ash transport blower and the capacity of fly ash transport according to the optimum mixture ratio by experimenting the fly ash conveying system of domestic D coal thermal power plants, which is currently in operation. The experiment results showed that the maximum fly ash conveying capacity of fly ash system were founded under the condition of maximum air volume 5,040 m3/h, static pressure of trip condition 1,163 mmH2O. In addition, it was predicted maximum mixture ratio of the air-fly ash was 8.66 and maximum capacity of fly ash conveying was 52,600 kg/h under these conditions.

  • PDF

Ammonia-fueled Solid Oxide Fuel Cell Recirculation Systems for Power Generation (암모니아 활용 고체산화물 연료전지 재순환 발전 시스템)

  • JIN YOUNG PARK;THAI-QUYEN QUACH;JINSUN KIM;YONGGYUN BAE;DONGKEUN LEE;YOUNGSANG KIM;SUNYOUP LEE;YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.40-47
    • /
    • 2024
  • Ammonia is drawing attention as carbon free fuel due to its ease of storage and transportation compared to hydrogen. This study suggests ammonia fueled solid oxide fuel cell (SOFC) system with electrochemical hydrogen compressor (EHC)-based recirculation. Performance of electrochemical hydrogen pump is based on the experimental data under varying hydrogen and nitrogen concentration. As a result, the suggested system shows 62.04% net electrical efficiency. The efficiency is 10.33% point higher compared to simple standalone SOFC system (51.71%), but 0.02% point lower compared to blower-based recirculation system (62.06%). Further improvement in the EHC-based SOFC recirculation system can be achieved with EHC performance improvement.