Experimental Study on the Operating Characteristics of an Environmental Control System for Avionic Equipments |
Park, Hyung-Pil
(Dept. of Mechanical Engineering, Korea Univ.)
Kang, Hoon (Dept. of Mechanical Engineering, Korea Univ.) Chi, Yong-Nam (Bookwang Construction & Corporation) Choi, Hee-Ju (R&D Center, FIRSTEC Co., Ltd.) Byeon, Young-Man (R&D Center, FIRSTEC Co., Ltd.) Kim, Young-Jin (R&D Center, FIRSTEC Co., Ltd.) Oh, Kwang-Yoon (R&D Center, FIRSTEC Co., Ltd.) Kim, Yong-Chan (Dept. of Mechanical Engineering, Korea Univ.) |
1 | Kazan, T. J. and Grabow. R. M., 1997, "Temperature, Altitude and Humuduty Test of a Ram Air Driven Air Cycle Cooled Airborne Equipment Pod," 32st AIAA Thermophysics Conference, AIAA-97-2466. |
2 | Grabow, R. M. and Kazan, T. J., 1996, "Design of a Ram Air Driven Air Cycle Cooling System for Fighter Aircraft Pods," 31st AIAA Thermophysics Conference, AIAA 96-1907. |
3 | Godecker, W. J., Lentz, J. C., Parme, C. B., Wigmore, D. B. and Winans, K. B., 1992, "Vapor Cycle System for a Fighter Aircraft-The Lantirn ECU Lessons Learned," 22nd International Conference on Environmental Systems, SAE 921184. |
4 | Han, D. and Kwon, H., 1999, "Zone Temperature Control of the Multi-Type Heat Pump System," Proceedings of the SAREK, pp. 611-616. |
5 | ASHARE Standard 51-75, 1975, Laboratory Methods of Testing Fans for Rating. |
6 | MIL-HDBK-310, 1997, Global Climatic Data for Developing Military Products. |
7 | Kang, H., Park, H. P., Lee, E. C., Kim, Y. C., Chi, Y. N., Choi, H. J., Byeon, Y. M., Kim, Y. J. and Oh, K. Y., 2009, "Experimental Study on Cooling Characteristics of an Environmental Control System for Avionic Reconnaissance Equipment," Journal of the SAREK, Vol. 21, No. 9, pp. 519-526. 과학기술학회마을 |