• 제목/요약/키워드: Blood volume pulse

검색결과 61건 처리시간 0.033초

초산모에서 경막외 $L_{1-2}$$L_{3-4}$ 차단 시 제통효과와 분만기간의 비교 (Comparison of Analgesic Efficacy and Shortening of Labor Duration between $L_{1-2}$ and $L_{3-4}$ Epidural Blocks in Nulliparous Normal Vaginal Delivery)

  • 강규식;이상윤;김정순;남계현;박욱
    • The Korean Journal of Pain
    • /
    • 제14권1호
    • /
    • pp.61-67
    • /
    • 2001
  • Background: Usually, lumbar epidural block is performed on the $L_{3-4}$ interspace. This study was designed to evaluate the analgesic efficacy and shortening of labor duration comparing the $L_{1-2}$ and $L_{3-4}$ interspace epidural blocks in nulliparous normal vaginal deliveries and then investigates side effects following the blocks. Methods: Eighty healthy nulliparous women were divided into two groups, $L_{1-2}$ (n = 40) and $L_{3-4}$ (n = 40). Epidural blocks, lumbar epidural block were performed at the $L_{1-2}$ and $L_{3-4}$ interspace with a catheter advancing 3 cm cephalad. The initial dose of 12 ml (0.167% bupivacaine, fentanyl $50{\mu}g$ and clonidine $75{\mu}g$) was injected epidurally at 4 cm dilatation of cervix and severe pain of labor. If a visual analogue scale (VAS) score was more than 4 points, an additional dose was administered epidurally using the same volume as the above mentioned, but with the exception that the bupivacaine was diluted to 0.1 percentage. The maternal blood pressure, pulse rate, respiration rate and fetal heart rate were measured at 10 min intervals for the first 30 min, at 15 min interval for the next 30 min and at 30 min interval for the last one hour following the blocks. The duration of the first (active) and second stages of labor was counted and the neonatal Apgar score was recorded at one and five min after delivery. The degree of motor block, pruritus, nausea and vomiting were also noted. Results: The patients in group $L_{1-2}$ had lower pain scores than group $L_{3-4}$ at 5, 20, 30, 60 mins. The duration of 1st and 2nd labor stage in the $L_{3-4}$ epidural block were $272{\pm}33.5$ min, $49.2{\pm}27.4$ min respectively but those in the $L_{1-2}$ epidural block were $253.5{\pm}32.5$ min, $37.3{\pm}22.3$ min, respectively. Conclusions: We concluded the analgesic efficacy and shortening of labor duration in $L_{1-2}$ epidural block was better than those in $L_{3-4}$ epidural block. Maternal hemodynamic change, motor block. pruritus, nausea, vomiting and Apgar score showed no significant differences between the two groups.

  • PDF

Effect of misting and wallowing cooling systems on milk yield, blood and physiological variables during heat stress in lactating Murrah buffalo

  • Yadav, Brijesh;Pandey, Vijay;Yadav, Sarvajeet;Singh, Yajuvendra;Kumar, Vinod;Sirohi, Rajneesh
    • Journal of Animal Science and Technology
    • /
    • 제58권1호
    • /
    • pp.2.1-2.10
    • /
    • 2016
  • Background: Heat stress adversely affects the physiological and metabolic status, and the productive performance of buffalo. Methods: The present study was conducted to explicate the effect of misting and wallowing cooling strategies during heat stress in lactating Murrah buffalo. The study was conducted for three months (May-July) of which first two months were hot dry and last month was hot humid. Eighteen lactating buffaloes, offered the same basal diet, were blocked by days in milk, milk yield and parity, and then randomly allocated to three treatments: negative control (no cooling), cooling by misting, and cooling by wallowing. Results: The results showed higher (P < 0.05) milk yield in buffaloes of misting and wallowing group compared to control during the experimental period however wallowing was found more (P < 0.05) effective during July (hot humid period). Both the treatments resulted into significant (P < 0.05) reduction in rectal temperature (RT) and respiratory rate (RR) compared to control animals during study period whereas wallowing was found to be effective on pulse rate (PR) only during July. Both treatments were resulted in mitigating the heat stress mediated decrease in packed cell volume (PCV), lymphocytopnoea and neutrophilia whereas decrease in total erythrocyte count (TEC) and monocytes was only mitigated by wallowing. Heat load induced alteration in serum creatinine and sodium concentration was significantly (P < 0.05) ameliorated by misting and wallowing whereas aspartate aminotransferase, alkaline phosphatase and superoxide dismutase activity, and reactive oxygen species concentration could be normalized neither by misting nor by wallowing. The significant (P < 0.05) increment in serum cortisol and prolactin levels observed in June and July period in control animals was significantly (P < 0.05) prevented by misting and wallowing. Conclusions: It can be concluded that misting and wallowing were equally effective in May and June (hot dry period) whereas wallowing was more effective during hot humid period in preventing a decline in milk production and maintaining physiological, metabolic, endocrine and redox homeostasis.

무료함, 통증, 그리고 놀람 정서 간 자율신경계 반응의 차이 (Difference of Autonomic Nervous System Responses among Boredom, Pain, and Surprise)

  • 장은혜;음영지;박병준;김상협;손진훈
    • 감성과학
    • /
    • 제14권4호
    • /
    • pp.503-512
    • /
    • 2011
  • 최근 HCI 분야에서 정서 인식은 정서 지능을 구현하기 위한 핵심적인 단계 중의 하나이다. 생체신호를 이용하여 정서 인식을 시도하는 연구들이 시도되고 있으나, 기본 정서 이외의 다른 정서에 대한 연구는 거의 이루어지지 않았다. 본 연구의 목적은 무료함, 통증, 그리고 놀람의 세 가지 정서 간 자율신경계 반응의 차이를 확인하는 것이다. 실험자는 217명의 실험참여자(남 96명)들을 대상으로 시/청각 자극을 조합하여 무료함과 놀람 정서를 유발하였고, 혈압기를 이용하여 통증 정서를 유발하였다. 정서 자극이 제시되는 동안 피부전기활동, 피부온도, 심전도와 광혈량도를 측정하였고, 실험참여자들이 경험한 정서 범주와 강도를 정서평가척도 상에 평정하게 하였다. 정서 자극에 대한 평가 결과, 사용된 정서 자극은 평균 92.5%의 적합성과 5.43의 효과성을 보였는데, 이는 각 정서 자극이 해당 정서를 효과적으로 유발한 것을 의미한다. 자율신경계 측정 결과, 피부전기활동, 피부온도, 심박률, 심박률의 저주파수 성분과 평균 혈류량은 안정 상태와 정서 상태 간의 유의한 차이를 보였다. 또한 각 정서에 의해 유발된 자율신경계 반응은 정서 간에도 유의한 차이가 있는 것으로 나타났다. 이러한 결과는 정서이론의 확장과 자율신경계 반응 측정 지표를 활용하여 정서를 인식하는 알고리즘 및 인간 정서를 변별하는 컴퓨터 시스템 개발에 응용 가능할 것이다.

  • PDF

생체신호 피드백을 적용한 가상 주행환경에서 사이버멀미 감소 효과 (The Efficacy of Biofeedback in Reducing Cybersickness in Virtual Navigation)

  • 김영윤;김은남;정찬용;고희동;김현택
    • 감성과학
    • /
    • 제5권2호
    • /
    • pp.29-34
    • /
    • 2002
  • 이전 연구에서 가상현실에 몰입하는 동안 넓은 시야(field of view : 150˚)와 빠른 운행속도(70km/sec)가 사이버 멀미를 심화시킨다는 결과를 얻었다. 피험자의 90%가 좁은 시야(50˚)와 느린 운행속도(30km/sec)에서 사이버멀미 증상이 적었다. 본 실험에서는 피험자가 생리적인 동요를 경험할 때마다 바이오피드백 방법을 사용하여 사이버 멀미 감소 가상환경(cybersickness alleviating virtual environment ; CAVE)을 제시한 후, 그 효과를 관찰하였다. 피부전도도, 말초체온, 말초 혈류량, 심박률, 눈 깜박임, 뇌전위의 변수들을 입력하는 인공 신경망으로 구성된 실시간 멀미 탐지 시스템과 CAVE-제시 피드백 시스템을 구축하였다 이 시스템들은 생리적 측정치들이 사이버 멀미의 출현을 신호할 때마다 피드백 출력으로 좁은 화면과 감소된 운행속도를 일시적으로 제공하였다. 36명의 피험자를 대상으로 SSQ(simulator sickness questionnaire)와 자기보고를 이용하여 사이버 멀미의 빈도와 심각도를 조사하였다. 모든 피험자는 한달 간격으로 CAW 조건과 non-CAYE 조건에서 두 번 가상현실을 경험하였다. 사이버멀미의 빈도와 심각도는 non-CAVE 조건보다 CAVE 조건에서 유의미하게 감소하였다. 즉, 전기 생리학적 특징들에 기반한 인공 신경망에 의해 제공된 좁은 시야와 느린 운행의 가상환경은 사이버 멀미 증상들을 감소시켰다 이러한 결과들은 생체신호 피드백 시스템을 이용하여 인간 친화적 가상환경을 구축할 수 있는 가능성을 보인 것이다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

면양에서 생리적 분비형태의 테스토스테론이 황체형성호르몬의 분비 억제에 미치는 효과 (The inhibitory effect of physiological pattern of testosterone on luteinizing hormone secretion in sheep)

  • 임태진;박경식
    • 대한수의학회지
    • /
    • 제35권2호
    • /
    • pp.271-278
    • /
    • 1995
  • 본 연구의 목적은 거세한 숫양에서 테스토스테론의 생리적인 주기적 분비형태가 황체형성호르몬의 분비억제에 미치는 효과를 연구하는 데 있다. 이를 위해, 3개의 서로 다른 실험들을 수행하였다. 실험 1에서는 정상적인 숫양에서 관찰되는 테스토스테론의 분비방식과 동일한 분비형태를 인위적으로 만들기 위해 필요한 테스토스테론의 주입비율과 분비형태를 얻기 위하여 3가지 다른 양(25, 50 그리고 $100{\mu}g$)의 테스토스테론을 정맥에 주입시켜 테스토스테론의 약리동력학을 분석한 결과, 테스토스테론의 평균 제거율상수, 분포용적, 그리고 총 체청소율은 각각 $0.18min^{-1}$, 0.531/kg, 그리고 0.091/min/kg 이었다. 실험 2에서는 테스토스테론의 처리 시간의 경과에 따른 테스토스테론의 황체형성호르몬 평균 농도의 억제 효과를 조사하기 위하여 3가지 다른 분비율(192, 384 그리고 $768{\mu}g/kg/24h$)의 테스토스테론을 주기적으로(4시간 간격) 3일 동안 정맥에 주입시킨 결과, 테스토스테론의 처리 시간이 증가함에 따라 혈액 내 황체형성호르몬의 평균 농도는 서서히 감소하였다. 테스토스테론을 2일 또는 3일간 처리하였을 때는 테스토스테론을 처리하기 전에 비해 황체형성호르몬의 평균 농도는 현저히 감소하였다. 그러나 테스토스테론의 1일간 처리는 황체형성호르몬의 평균 농도를 감소시키지 못하였다. 실험 3에서는 두 가지 다른 분비 형태(지속적 분비 형태와 주기적 분비 형태)의 테스토스테론의 황체형성호르몬의 분비에 미치는 효과를 비교 조사하였다. 지속적 분비형태를 만들기 위하여 테스토스테론을 3일간 지속적으로($32{\mu}g/kg/h$) 정맥 주입시켰고, 주기적 분비 형태를 만들기 위하여 테스토스테론을 4시간 간격으로 3일간 주기적으로($128{\mu}g/kg/h$) 정맥 주입시켰다. 지속적 방법과 주기적 방법 간에 동일한 양($768{\mu}g/kg/h$)의 테스토스테론이 주입되었다. 혈액은 테스토스테론의 정맥 주입전 4시간 동안과 3일간 정맥 주입 기간 중 마지막 4시간 동안 각각 10분 간격으로 경정맥에서 채취하였고, 황체형성호르몬과 주입된 테스토스테론의 혈액 내 농도는 각각의 방사성면역방법을 이용하여 측정하였다. 황체형성호르몬의 펄스 간격(p<0.034)과 황체형성호르몬의 평균 분비량은(p<0.045) 주지적 방법 보다 지속적 방법의 테스토스테론의 주입에 의해 현저히 증가하였다. 황체형성호르몬의 펄스 분비량은 주기적 방법과 지속적 방법 간에 차이가 없었다. 이상의 결과들은 숫양에서 지속적 방법의 테스토스테론이 주기적 방법의 테스토스테론의 보다 황체형성호르몬의 분비를 저하시키는데 보다 더 효과적임을 나타내 보이고 있다.

  • PDF

자발적 호흡정지 및 재개시 동맥혈 산소포화도와 심박수의 변동양상과 이에 영향을 미치는 인자 (The Patterns of Change in Arterial Oxygen Saturation and Heart Rate and Their Related Factors during Voluntary Breath holding and Rebreathing)

  • 임채만;김우성;최강현;고윤석;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권4호
    • /
    • pp.379-388
    • /
    • 1994
  • 연구배경 : 수면 무호흡증후군은 수면시 반복적인 무호흡이 발생하여 일련의 심폐계통의 변화가 초래되는 질환으로 이중 동맥혈 산소포화도(arterial oxygen saturation, 이하 $SaO_2$)의 감소와 심부정맥의 발생이 임상적으로 중요한 소견이다. 무호흡시 $SaO_2$의 감소양상은 환자마다 다양하며 이는 호흡정지 기간, 호흡정지시의 산소공급원인 폐용량 및 개체의 산소소모율에 따라 결정될 것으로 예상된다. 방법 : 호흡정지와 재개시에 수반되는 $SaO_2$ 및 심박수(heart rate, 이하 HR)의 변동양상을 관찰하고, 그 변동에 관련되는 생리학적 인자들을 알아보고자 정상 남자 8명 및 정상 여자 9명 등 총 17명을 대상을 폐용량 측정, 동맥혈 가스분석을 시행하고 Harris-Benedict 식에 의거한 기초대사율을 산출한 뒤 총폐용량(total lung capacity, 이하 TLC), 기능적 잔기량(functional residual capacity, 이하 FRC) 및 잔기량(residual volume, 이하 RV) 상태에서 호흡정지를 시킨 후, $SaO_2$의 변동과 심전도를 측정기록하였다. 결과 : 호흡정지시 $SaO_2$가 기저치로부터 2% 감소하는데 걸린 시간(T2%)은 TLC, FRC 및 RV 에서 각각 $70.1{\pm}14.2$$44.0{\pm}11.6$초 및 $33.2{\pm}11.1$초로 TLC보다는 FRC 에서(p<0.05), FRC보다는 RV에서(p<0.05) 유의하게 단축되었다. T2%까지 호흡정지한 뒤 호흡재개시 $SaO_2$의 추가 감소는 RV에서 $4.3{\pm}2.1%$로서, TLC의 $1.4{\pm}1.0%$나 FRC의 $1.9{\pm}1.4%$ 보다 감소량이 컸고(각각 p<0.05), 최저 $SaO_2$치에서 기저치로의 회복에 걸린 시간은 TLC, FRC 및 RV에서 유의한 차이가 없었다. T2%는 각각의 폐용량 혹은 기초대사율과 유의한 상관관계는 없었으나, TLC/BMR(r=0.693, p<0.001) 및 FRC/BMR(r=0.615, p<0.025)과는 각각 유의한 상관관계를 보였고, RV/BMR(r=0.027, p>0.05)과는 유의한 상관관계가 없었다. 호흡정지와 재개의 전 과정에서 생긴 최대심박수와 최초심박수의 차이는 TLC에서 $27.5{\pm}9.2$회/분, FRC 에서 $19.1{\pm}6.0$회/분, RV에서 $26.4{\pm}14.0$회/분으로 FRC에서의 심박수 변화량이 TLC나 RV에서의 변화량보다 유의하게 적었고(각각 p<0.05), 기록상 호흡재개 시점을 전후한 5개씩의 p-p간격의 평균치는 TLC에서 $0.84{\pm}0.10$초와 $0.72{\pm}0.09$초(p<0.025), FRC에서 $0.82{\pm}0.11$초와 $0.73{\pm}0.09$초(p<0.025), RV에서 $0.77{\pm}0.09$초와 $0.72{\pm}0.09$초(p<0.05)로 모두 유의한 차이가 있었다. 결론 : 정상인에서 FRC이상에서 호흡정지시 $SaO_2$의 감소속도는 폐용량/기초대사율과 밀접한 상관관계를 보이고, 호흡정지-재개의 과정에서 생기는 동성부정맥은 FRC상태가 제일 작고 미주신경활성도의 변화가 관여하는 것으로 추정되며, RV에서의 실험결과로 미루어 수면 무호흡증후군 환자들에서 체위, 혹은 복부비만에 기인하는 기능적 잔기량의 감소가 저산소혈증의 정도나 심부정맥의 발생에 미치는 영향에 대한 연구가 필요하고, 수면시의 기능적잔기량을 증가시키는 것이 치료적 유용성이 있는지에 대한 검증도 필요하리라고 사료된다.

  • PDF

농업기상 정보 및 배분 네트워크 현황 (Status of Agrometeorological Information and Dissemination Networks)

  • Jagtap, Shrikant;Li, Chunqiang
    • 한국농림기상학회지
    • /
    • 제6권2호
    • /
    • pp.71-84
    • /
    • 2004
  • 농업기상정보에 대한 수요는 흥미로운 내용보다는 농업현장에서 사용자가 직접 활용할 수 있는 내용이 점증하고 있다. 이러한 수요에 부응하기 위해서는 지역 또는 집단 별로 소속 농민을 위한 지역특성이 반영된 기후/기상 정보를 개발, 제공하여야 한다. 그리고 최종 사용자가 공식 기상기구에 의해 발표된 기상/기후 예보를 이해하는 데 도움을 줄 수 있는 도구가 제공되어야 한다. 특히 기본이 되는 근간자료를 포함하여 실시간 기상정보도 농민에게 함께 제공되어야 한다. 따라서 이상적인 농업기상정보시스템은 다음과 같은 요소를 포함하여야 한다. 1) 효율적인 자료 관측과 수집 체계, 2) 최신 통신시스템, 3) 표준 자료관리, 가공 및 분석 시스템, 및 4) 첨단 기술정보 배분시스템 등. 향후 인터넷이 농업기상정보 전달과 배분에 있어서 지속적으로 중요한 역할을 수행하겠지만 정보 풍요국과 빈곤국간의 격차는 날로 심화되어 갈 것이다. 그리고 농촌지역은 정보통로의 가장 끝자락을 의미하는데, 앞으로 많은 나라에서 정보통신 수단으로 TV, 라디오, 전화, 신문 및 팩스 등에 의존할 것으로 보이며, 정보와 배분 수단 확충에 필요한 가용 인적 및 경제적 자원에 따라 국가 간에 그 달성 여하에 차이가 있을 것이다. 이러한 차이점들은 농업기상 정보배분시스템 구축설계시에 반드시 고려되어야 한다. 과거 경험에 따르면, 사용자 요구에 적극 부응하는 정보들에 대한 손쉬운 접근을 통해서 기후정보의 활용이 근원적으로 증대한다는 것을 알 수 있다. 지리정보시스템과 원격탐사정보의 농업기상분야 적용도 향후 그 전망이 매우 밝은 분야라고 생각된다. 수 있을 것으로 사료된다. 유방병소를 수술전에 위치결정하는 방법은 그 수기가 간단하고도 안전하며 병소를 정확히 지시해 줌으로써 수술적 생검에 큰 도움을 주었고 그럼으로써 정상유방조직의 절제를 최소화하여 수술 후에 오는 유방의 외형상 변형을 최소화할 수 있었다. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We has experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechani 는 of pulmonary edema caused by intravascular injection of the iodinated contrast materials.석

관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구 (The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion)

  • 박영우;허균;임재웅;신화균;원용순
    • Journal of Chest Surgery
    • /
    • 제39권5호
    • /
    • pp.354-358
    • /
    • 2006
  • 배경: 체외순환에 사용되는 박동성 펌프는 비박동성 펌프에 비해 조직관류가 좋지만 혈구손상이 많다고 알려져 왔다. 관상동맥우회술 시 박동성 펌프인 $T-PLS^{TM}$(이중 박동성 인공심폐기)와 비박동성 펌프인 $Bio-pump^{TM}$의 임상결과를 비교하여 $T-PLS^{TM}$의 안전성 및 장단점을 알아보고자 하였다. 대상 및 방법: 2003년 4월부터 2005년 6월까지 관상동맥우회술을 시행 받은 40명을 대상으로 하였다. $T-PLS^{TM}$을 이용하여 관상동맥 우회술을 시행 받은 환자는 20명이었고 $Bio-pump^{TM}$을 이용하여 관상동맥우회술을 시행 받은 환자는 20명이었다. 수술은 모든 환자에서 심폐체외순환하에서 박동하여 시행하였다. 수술 전 위험인자와 수술 중 상태, 술 후 결과를 비교하였다. 결과: 두 군 간 연령, 남녀비, 당뇨, 고혈압, 흡연력 및 폐쇄성 폐질환, 심근경색, 신부전 등 술 전 위험요소는 차이가 없었다. 수술시간, 심폐기 사용시간, 사용한 우회도관 및 문합한 관상동맥분지는 두 군에서 차이가 없었다. 수술 중 수축기 동맥압, 이완기 동맥압, 평균동맥압은 두 군 간 차이는 없었지만 맥박압은 $T-PLS^{TM}$군에서 높게 측정되었다$(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. 수술 중 소변량은 $T-PLS^{TM}$군에서 높은 경향이 있었지만 통계적 의미는 없었다$(9.7{\pm}3.9\;in\;T-PLS^{TM}\;versus\;8.9{\pm}3.6\;in\;Bio-pump^{TM},\;p=0.20)$. 수술 후 평균 호흡기 사용시간, 24시간 실혈량은 두 군간 차이는 없었다. 수술 후 유리혈장색소는 $T-PLS^{TM}$군에서 유의하게 낮게 측정되었다$(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;vs\;46.8{\pm}23.0\;in\;Bio-pump^{TM},\;p<0.05)$. 수술 후 심근경색, 부정맥, 신부전, 뇌혈관질환 이환율은 두 군에서 차이가 없었다. 수술 후 사망은 $T-PLS^{TM}$군에서 1예(5%) 발생하였으나 통계적 유의성은 없었다. 결론: 박동성 혈류펌프인 $T-PLS^{TM}$를 이용하여 심폐기하 관상동맥 우회술을 시행하였다. 수술 중 기계오류에 의한 사고는 없었고 수술 후 임상경과가 $Bio-pump^{TM}$를 이용하여 수술한 경우와 차이가 없었다. 또한 박동성 혈류의 문제점이었던 혈구손상은 감소하였다. 저자들은 본 연구를 통해 $T-PLS^{TM}$의 안정성을 확인하였다.