• 제목/요약/키워드: Blood viscosity

검색결과 123건 처리시간 0.024초

좌주간부 관상동맥에 관한 혈류역학적 분석 (I) (Hemodynamic Analysis of Pig's Left Common Coronary Artery (I))

  • 박정수;장주희;문수연;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1923-1929
    • /
    • 2003
  • The present study investigated the microcirculation of blood in the left common artery (LCCA). In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary conditions. In this study, the statistical distribution of blood pressure, blood flow, and blood volume in the LCCA were determined based on the anatomical branching pattern of the coronary arterial tree and the statistical data of blood vessel dimensions. Our calculations were in good agreement with the previous studies. The present results showed that the mean longitudinal pressure drop profile was function of the vessel order numbers. It was found that the normalized pressure drop was a logarithmic function of the compliance.

  • PDF

흰쥐의 스트레스성 위궤양에 대한 Alove vera의 항궤양작용 (The Antiulcer Effects of Alove vera on the Stomach ulcer Induced by Stress in rats)

  • 박은지;이용욱
    • 한국식품위생안전성학회지
    • /
    • 제9권3호
    • /
    • pp.175-184
    • /
    • 1994
  • This was performed to investigate the antiulcer effects of Aloe vera on the stomach ulcer induced by restraint and water-immersion stress in rats. For this experiment, 60 male Sprague-Dawley strain were used. The experimental groups were divided into five: a control(CA) and 4 aloe treatment groups. Each dose of aloe was 50 mg/kg BW(AA), 100mg/kg BW(AB), 200 mg/kg BW(AC), and 400 mg/kg BW(AD). The rats were allocated to each group by 12 and observed for 4 weeks. The results are as following. 1. The stomach surface pH in each group showed no significant difference, byt the values of aloe treatment groups were higher than the value of the control group. 2. The gastric wall mucus was significantly increased in all aloe treatment groups(p<0.05) compared with the control group. Especially in AC and AD group the differences were higher(p<0.01). 3. At shear rate rate 11.25, 45.0, 90.0, 225.0 sec-1, whole blood viscosity and plasma viscosity were measured. Most of the values of aloe treatment groups were significantly low compared with those of the control group(P<0.05). 4. The ulcer index of aloe treatment groups were significantly low campared with control group(p<0.05). Especially in AC and AD group the differences were more significant(p<0.01). 5. Less severe ulcers were observed in AA and AB group than in the control group. Tissues of AC and AD group had only slight ulcers and necrosis of tissue was not observed in these groups. Especially in AD group, there was more mucus than other groups and it seemed that alove vera stimulated the epithelial regeneration. From the results of this study, it can be concluded that the oral administration of Alove vera results in protection of stomach ulcer by stimulating the secretion of gastric mucus and the circulation of blood.

  • PDF

Multiple-enzyme supplementation on digestive traits, carcass characteristics, blood lipid parameters and growth performance of broilers fed a wheat-based diet

  • Taheri, Hamid Reza;Shirzadegan, Kayvan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제30권9호
    • /
    • pp.1285-1291
    • /
    • 2017
  • Objective: A trial was conducted from 11 to 42 d post-hatch to investigate the effectiveness of the supplementation of a multiple-enzyme preparation (Natuzyme Plus) in a wheat-based diet on digesta viscosity, pH and microbial population, villus morphology, feed passage time, nutrient retention, carcass characteristics, blood lipid parameters and growth performance of broiler chickens. Methods: Three hundreds 10-d-old male Ross 308 chicks were allocated to three diets with five replicates of 20 birds per replicate. Dietary treatments were i) a wheat-based diet (W), ii) W+Natuzyme Plus (WN; 500 mg/kg of the diet), and iii) a corn-based diet (C). Results: Birds fed on the C diet had higher average daily gain (ADG, p<0.01), villus height (VH, p<0.01), total tract apparent retention (TTAR) of nitrogen (NT, p<0.01) and ether extract (EE, p<0.01), nitrogen-corrected apparent metabolizable energy ($AME_n$, p<0.05), relative weight (RW, % of body weight) of carcass (p<0.05), blood concentration of triglyceride (TG, on d 40 [p<0.01]), total cholesterol (TC, on d 22 [p<0.05]) and low density lipoprotein (LDL, on d 22 [p<0.01] and 40 [p<0.05]), and also lower feed conversion ratio (FCR, p<0.01), digesta viscosity (p<0.01), count of coliforms (p<0.01) and Escherichia coli (p<0.01) and epithelium thickness (ET, p<0.05) than those fed on the W diet. ADG, FCR, VH, ET, TTAR of NT and EE, RW of carcass, blood concentration of TG (on d 40), TC (on d 22) and LDL (on d 22 and 40) values of the WN diet did not show a significant (p>0.05) difference compared to those of the C diet. Compared to those of the W diet, the WN diet showed the higher count of Lactobacilli and lower count of coliforms (p<0.01) and digesta viscosity (p<0.01). Conclusion: In general, the results of this study showed that Natuzyme Plus supplementation in a wheat-based diet can be appropriate to achieve a comparable growth performance in broiler chickens to those given the C diet probably through improving digesta viscosity, VH, ET, TTAR of NT and EE, $AME_n$, count of Lactobacilli and coliforms.

혈액펌프 성능평가를 위한 실험장치 구성 (An Experimental Setup for Measuring the Performance of Blood Pumps)

  • 김성길;홍석빈;김태홍;김원정;강성원;강신형;허남건
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.55-60
    • /
    • 2016
  • We present an experimental setup for measuring the mechanical performance of centrifugal blood pumps. Using a 3D printer to construct supporting parts and magnetic couplings, we developed the measurement setup that can be used for various types of blood pumps. The experimental setup is equipped with sensors to measure a variety of mechanical characteristics of blood pumps including pressure, flow rate, torque, temperature, and rotating speed. Our experimental measurements for two commercial blood pumps are consistent with data provided by manufacturers, which indicates that the our setup offers the accurate measurements of blood pump performance. Utilizing the experimental setup, we tested aqueous glycerin solutions mimicking the density and viscosity of blood, which enabled us to predict the difference in operations using water and blood.

좌주간부 관상동맥(LCCA)에 관한 혈류역학적 분석 (II) (Hemodynamic Analysis of Pig's Left Common Coronary Artery (LCCA) (II))

  • 문수연;장주희;박정수;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2043-2047
    • /
    • 2003
  • The distributions of blood pressure, blood flow, and blow volume in the left common artery (LCCA) were determined using the lumping parameter method. In order to develop a mathematical model for microcirculation in LCCA, the present study adopted preexisted set of measured morphological data on anatomy, mechanical properties of the coronary vessels, viscosity of blood, the basic laws of physics, and the appropriate boundary condition. Pressures and volumes of blood and flow resistance were expressed in terms of electrical voltages, current, and resistances, respectively, in the electrical analog model. The results of two mathematical models, symmetrical and asymmetrical models, were compared with other investigator's data. The present results were in good agreement with previous studies. It was found that the mean pressure profiles were similar in both models.

  • PDF

미병 정량 지표에 관한 중국의 임상연구 동향 분석 - China National Knowledge Infrastructure를 중심으로 - (Analysis of Clinical Research Trends on Quantitative Indicators of Mibyeong in China - Using China National Knowledge Infrastructure -)

  • 여민경;이영섭
    • 대한예방한의학회지
    • /
    • 제22권1호
    • /
    • pp.15-28
    • /
    • 2018
  • Objectives : The purpose of this study was to analyze the trend of clinical research on quantitative indicators of Mibyeong in traditional chinese medicine(TCM). Method : The journal search was performed using china national knowledge infrastructure(CNKI) database. Our inclusion criteria were as following: TCM clinical researches for quantitative indicators of Mibyeong. Exclusion criteria were as following: non-TCM clinical researches, used intervention methods. Results : Eleven clinical researches were analyzed in this study. Four of these researches classify the Mibyeong as a type of pattern identification(PI) and studied the characteristics of the PI quantitative indicators. Mibyeong diagnosis was done through guidelines and questionnaires, each was used at a similar rate. Quantitative indicators mentioned in the selected researches were blood indices, nailfold capillary, complexion, color of tongue substance and coating, pulse wave diagrams and heart rate variability. Among them, seven researches related to blood indices were the most. Blood indicators include whole-blood viscosity, plasma viscosity, fibrinogen, packed cell volume(Hct), triglycerides, total cholesterol, HDL-C, LDL-C, glucose, BUN/CREA, luteinzing hormone, estradiol, follicle stimulating hormone, IgA, IgG, etc. Conclusions : Based on this results, in combination with western medicine, it seems necessary to try to interpret the Mibyeong in more various ways. Even if the same Mibyeong, it is necessary to identify the index which changes according to the PI or chief complaint, and to set the Mibyeong standard corresponding thereto.

IN-VITRO CHARACTERIZATION OF THE THROMBOTIC POTENTIAL OF WHOLE BLOOD USING AN IMPEDANCE METHOD

  • Granaderos, Carlo;Park, Joong-Chun;Pak, Bock-Choon;Kim, Cheol-Sang;Cho, Young-I
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2785-2790
    • /
    • 2007
  • This study presents an impedance method of in-vitro characterization of the thrombotic potential of whole blood. Whole blood samples of 0.2 cc were put into a micro-cell with embedded three electrodes immediately after venepuncture at $37^{\circ}C$. Anti-coagulated blood samples were also collected for hematocrit and blood viscosity analyses. The rate of change of electron flow was measured, which indicates the inverse of the thrombotic potential. A sudden decrease in the rate of change of electron flow was observed at a time equal to approximately 110 seconds. This sudden decrease was significantly delayed in anti-coagulated samples. After the sudden decrease, the rate continued to decrease, reaching a minimum value in unadulterated samples while the change in the rate in the anti-coagulated ones was found rather moderate. Based on these preliminary findings, the present method may be of used as a new tool for the diagnosis of the thrombotic potential of whole blood.

  • PDF

Laser Doppler를 이용한 자율신경 기능 평가 방법 (Evaluation of the Autonomic Nervous System Using Laser Doppler)

  • 남상희;신정욱;조종만
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.51-54
    • /
    • 1993
  • The purpose of this research is to investigate the relationship between the blood flow and autonomic nervous system which regulates the circulation system. After the oral glucose tolerance test(GTT) the velocity changes of the blood flow were measured from the normal, hyperglycemia and diabetic neuropathy using the laser doppler. The FFT analyses showed that the spectrums were concentrated around the particular bands(0.02-0.166Hz, 0.8-1.1Hz) for the normal, while almost uniform distribution of the spectrums was observed for the abnormal. The blood glucose affects the compliance of the blood vessels and viscosity and finally causes the resistance problem in the blood vessels. An index PG was introduced, which was determined by the ratio of the change or the integral power spectrum in the range between 0.02 and 0.166Hz to change of the blood glucose before and after GTT. The index shows 1.0. 0.3 and 0.1 for the normal, hyperglycemia and diabetic neuropathy, respectively. As a conclusion, this spectrum analysis shows the potential of checking the progress or the diabetic, also car be used to evaluate the vasomotion which are regulated by the autonomic nervous system.

  • PDF

스마트 폰 기반 3D 프린팅 칩을 이용한 적혈구 변형성 측정 (Measurement of RBC (red blood cell) deformability using 3D Printed Chip combined with Smartphone)

  • 이수환;홍현지;염은섭;송재민
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2020
  • RBC (red blood cell) deformability is one of factors inducing blood shear thinning effect. Reduction of RBC deformability increases blood viscosity in high shear region. In this study, 3D printed chip with proper distribution of wall shear rate (WSR) was proposed to measure RBC deformability of blood samples. To fabricate 3D printed chip, the design of 3D printed chip determined through numerical simulation was modified based on the resolution of the 3D printer. For the estimation of pressure drop in the 3D printed chip, two bypass outlets with low and high WSR are exposed to atmospheric pressure through the needles. By positioning the outlet of needles in the gravity direction, the formation of droplets at bypass outlets can be captured by smartphone. Through image processing and fast Fourier transform (FFT) analysis, the frequency of droplet formation was analyzed. Since the frequency of droplet formation is related with the pressure at bypass, high pressure drop caused by reduction of RBC deformability can be estimated by monitoring the formation of blood droplets using the smartphone.

Numerical study of the effects of periodic body acceleration (PGZ) and bifurcation angle in the stenosed artery bifurcation

  • Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • 제21권3호
    • /
    • pp.175-183
    • /
    • 2009
  • This article describes the numerical investigation of blood flow in the stenosed artery bifurcation with acceleration of the human body. Using the commercial software FLUENT, three-dimensional analyses were performed for six simulation cases with different body accelerations and bifurcation angles. The blood flow was considered to be pulsation flow, and the blood was considered to be a non-Newtonian fluid based on the Carreau viscosity model. In order to consider periodic body acceleration, a modified, time-dependent, gravitational-force term was used in the momentum equation. As a result, flow variables, such as flow rate and wall shear stress, increase with body acceleration and decrease with bifurcation angle. High values of body acceleration generate back flow during the diastolic period, which increases flow fluctuation and the oscillatory shear index at the stenosis.