• 제목/요약/키워드: Blood properties

검색결과 707건 처리시간 0.028초

Construction of Membrane Sieves Using Stoichiometric and Stress-Reduced $Si_3N_4/SiO_2/Si_3N_4$ Multilayer Films and Their Applications in Blood Plasma Separation

  • Lee, Dae-Sik;Choi, Yo-Han;Han, Yong-Duk;Yoon, Hyun-C.;Shoji, Shuichi;Jung, Mun-Youn
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.226-234
    • /
    • 2012
  • The novelty of this study resides in the fabrication of stoichiometric and stress-reduced $Si_3N_4/SiO_2/Si_3N_4$ triple-layer membrane sieves. The membrane sieves were designed to be very flat and thin, mechanically stress-reduced, and stable in their electrical and chemical properties. All insulating materials are deposited stoichiometrically by a low-pressure chemical vapor deposition system. The membranes with a thickness of 0.4 ${\mu}m$ have pores with a diameter of about 1 ${\mu}m$. The device is fabricated on a 6" silicon wafer with the semiconductor processes. We utilized the membrane sieves for plasma separations from human whole blood. To enhance the separation ability of blood plasma, an agarose gel matrix was attached to the membrane sieves. We could separate about 1 ${\mu}L$ of blood plasma from 5 ${\mu}L$ of human whole blood. Our device can be used in the cell-based biosensors or analysis systems in analytical chemistry.

The Effect of GLM 002, an Oriental Medicine, on Blood Pressure and Plasma Lipids in Spontaneously Hypertensive Rats

  • Yu Byung Soo;Kim Hee Seok;Keon In Sook;Lee Cheol Han;Baek Seung Hwa
    • 동의생리병리학회지
    • /
    • 제18권5호
    • /
    • pp.1505-1511
    • /
    • 2004
  • Inhibition of angiotensin converting enzyme (ACE) activity is one of the common antihypertensive methods functioned by drugs such as captopril, lisinopril and enalapril to serve as inhibitors of ACE. This study was designed to compare the effects of enalapril, an angiotensin-converting enzyme inhibitor and GLM002, an oriental medicine, on tail systolic pressure, aorta and plasma properties in spontaneously hypertensive rats (SHR) after 4 weeks of treatment. During the treatment, blood pressure was depressed to normal in GLM002 and enalapril groups. The treatments of enalapril and GLM002 were discontinued in 4 weeks. One week after the treatment stop, systolic blood pressure was smoothly increased in both groups; the increment of blood pressure was slightly greater in GLM002-SHR, but the increment of plasma ACE activity was proportionately similar in each group. In the aspects of the triglyceride, HDL and total cholesterol level, those levels were slightly different among each group. We also conducted clinical dosage of GLM002 to the patients who have mild and severe hypertension for approximately 7 weeks. Clinical treatments also showed remarkable efficiencies on blood pressure (systolic blood pressure, diastolic blood pressure), complete blood count (CBC) routine, differ count (NEUTRO, LYM, MONO, EOS and BASO) and R-chemistry. We conclude that GLM002, like already proven enalapril, plays a role as an angiotensin-converting enzyme inhibitor, and can be suggested as a drug candidate for curing hypertension.

점탄성 유체해석용 RANS 기반 난류 모델 개발 및 검증 (Development and Evaluation of RANS based Turbulence Model for Viscoelastic Fluid)

  • 노경철
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.545-550
    • /
    • 2017
  • 대동맥이나 협착된 경동맥에서는 심장수축기에 간헐적으로 난류현상이 발생하고 있으며, 혈액의 점성특성으로 인해 기존 난류모델로는 정확한 해석이 어려운 실정이다. 혈류는 점탄성 유체의 성질을 가지고 있어 유체의 전단 변형률 증가에 따라 점도가 감소하는 점탄성 유체이며, 이러한 점탄성 유체는 난류 유동시 저항 감소 현상이 발생한다. 기존의 난류해석 모델들은 점성변화가 없는 뉴턴 유체에 적합한 모델들이 대부분이기 때문에, 점탄성 유체의 저항 감소 현상을 고려한 비뉴턴 유체 해석에 적합한 난류 모델개발이 필요하다. 본 논문은 난류 모델 가운데 수렴성이 좋고 해석시간이 짧은 표준 $k-{\varepsilon}$ 모델을 기반으로 저항 완충 함수를 이용하여 비뉴턴 유체의 저항감소 현상을 해석할 수 있는 수정된 난류모델을 제시하였으며, 이를 기존 난류모델들과 비교하여 제시된 난류 모델을 검증하였다. 새로 제시된 수정된 난류모델은 벽함수 및 점성저층을 고려하지 않았기 때문에 해석시간이 대폭적으로 감소하였으며, 적은 격자수를 이용하여 효율적으로 비뉴턴 유체의 난류 현상을 해석할 수 있기 때문에 향후 혈류해석 및 점탄성유체 해석에 적용할 예정이다.

광학계수를 이용한 생체물질의 특성에 관한 연구 (암조기진단을 위한 전단장치의 개발을 위한 기초연구) (The study on Biomaterial Properties using the Optical Coefficient)

  • 임현수;김부길;두재균
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.115-121
    • /
    • 1998
  • 본 연구는 암을 조기진단을 위한 장치개발의 기초 연구로서, 질병(암)을 검출할수 있는 광 특성의 존재를 결정하기 위하여 12개 생체조직의 계층별 시료와 인체의 혈액에서 광 특성을 측정하였다. 실험은 동물의 지방 및 근육 조직과 인체 혈액 HCT의 27.3%, 35.4%, 45.6%과 59.1%을 대상으로, 광파장이 630nm, 660nm, 780nm, 880nm, 940nm 에서 흡수 계수, $\mu$$_{\alpha}$를 측정하였다. 측정된 흡수계수는 일정하고 특이한 변화를 보여 주었다. 본 연구의 결과에 의하면 생체조직의 계층별과 광파장의 특정 파장대에서 분명한 차이를 구분할 수 있었다. 차이를 구분할 수 있었다.

  • PDF

Diamond-like carbon 및 titanium nitride 박막의 혈액적합성 연구 (Study on blood compatibility of diamond-like carbon and titanium nitride films)

  • 윤주영;배진우;박기동;구현철;박형달;정광화
    • 한국진공학회지
    • /
    • 제14권3호
    • /
    • pp.165-170
    • /
    • 2005
  • 의료용 임플랜트의 혈액적합성 개선을 위하여 박막코팅에 대한 관심이 증대하고 있다. 특히 diamond-like carbon(DLC)과 titanium nitride(TiN) 박막은 우수한 화학, 물리적 성질은 물론 생체적합 특성까지 갖추고 있다. 따라서 이들 박막의 혈액 적합성과 물리적 특성과의 관개를 연구하기 위하여 박막표면의 모폴로지 및 젖음성과 fibrinogen흡착 특성을 비교 분석하였다. 혈액응고 원인이 되는 fibrinogen의 흡착량은 DLC보다 TiN의 경우가 적어, 보다 우수한 특성을 보였으며, 이것은 TiN박막 표면의 높은 친수성으로 인한 것으로 판단된다. 박막표면의 fibrinogen 흡착을 줄이기 위해 플라즈마 처리 및 노(爐) 열처리를 각각 수행하였다. 산소 플라즈마 및 열처리를 하였을 경우 DLC 박막은 큰 효과가 없는 반면 TiN 박막의 경우 fibrinogen 흡착량이 크게 줄어 보다 개선된 결과를 보였다.

한국산 장류콩 종자 렉틴의 생화학적 특성 (Biochemical Properties of Seed Lectin from Korean Soybean Cultivars Developed for Soy Source)

  • 왕옥산;노광수
    • KSBB Journal
    • /
    • 제24권2호
    • /
    • pp.170-176
    • /
    • 2009
  • 한국산 장류콩 종자로부터 최종적으로 Sephadex G-100상에서 분리한 lectin의 분자량, 적혈구 응집력, 온도, 열 안정성, 및 pH의 생화학적 특성을 조사하였다. 분리된 lectin을 SDS-PAGE한 결과, 분자량이 32 kDa와 22 kDa인 2개의 band가 나타났으며, Native PAGE에 의해서 108 kDa의 tetramer임을 알 수 있었다. Lectin은 trypsin을 처리한 사람의 A, B, AB, O 혈액과 쥐 혈액에서 혈구응집 반응이 일어나지 않았으나 토끼에서는 응집 반응이 일어났으며, trypsin을 처리하지 않은 모든 혈액에서는 응집반응이 일어나지 않았다. 이 lectin은 최적온도가 20-$50^{\circ}C$이며, 10-$60^{\circ}C$ 에서 열 안정성을 보였다. 최적 pH는 7.2로서 6.2 이하와 8.0 이상에서는 활성이 상설되었다.

쌀의 영양학적.기능적 우수성 (Nutritional and Functional Properties of Rice)

  • 하태열
    • 한국식품저장유통학회:학술대회논문집
    • /
    • 한국식품저장유통학회 2002년도 창립 10주년 기념 국제학술심포지움
    • /
    • pp.64-71
    • /
    • 2002
  • Rice(Oryza stiva L.) is a major cereal food providing nourishment to over half of the world's populations and was considered only as a source of energy. However, The recent many researches have been made to suggest that rice may relate to prevention chronic disease and health-promoting properties such as postprandial glucose response, hypocholesterolemic effect and blood pressure-lowering effect. There has been numerous observation supporting that rice has hypocholesterolemic effect. Rice, rice bran, rice bran oil and unsaponifiable matter of rice bran oil reduced plasma cholesterol in rat, hamster as well as human. Components of rice showing hypocholesterolemic effect include dietary fiber(hemicellulose, phytic acid). protein, ${\gamma}$-oryzanol, $\beta$-sitosterol, and tocotrienols. Crapo et al has been studied that the effect of various of starchy foods on the postprandial blood glucose and insulin responses in healthy and diabetic humans. The results showed that rice had lower blood glucose and insulin responses compared to potato, bread and dextrose. The different physical forms in the same starch also produce the different postprandial glucose and insulin responses. In recent years, several studies have shown that some components of rice have potent antioxidant activity against Fe$^{2+}$ -ascorbate induced lipid peroxidation in rat liver microsomal membranes. Cell culture and animal studies have shown that some components of rice have inhibitory effect on the growth and proliferation of several types of human cancer cell. It was also reported that the methanol extract of brown rice has antimutagenic activity against various mutagens. In addition, the pepsine hydrolysate from rice protein is reported to inhibit angiotensin converting enzyme activity. GABA (${\gamma}$ - aminobutyric acid) and GABA enriched rice germ is also effective for lowering blood pressure and triglyceride levels.s.

  • PDF

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • 제54권2호
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Heparinized Bioactive Polymers for Biomedical Applications

  • Park, Ki-Dong;Go, Dong-Hyun;Bae, Jin-Woo;Jee, Kyung-Soo
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.48-49
    • /
    • 2006
  • The incorporation of heparin to biomaterials has been widely studied to improve the biocompatibility (blood and cell) of biomaterials surfaces. In our laboratory, various kinds of heparinized polymers including heparinized thermosensitive polymers ($Tetronic^{(R)}$-PLA(PCL)-heparin copolymers) and star-shaped PLA-heparin copolymers have been developed as a novel blood/cell compatible material. These heparinized polymers have demonstrated their unique properties due to bound heparin, resulting in improved biocompatibility. These heparinized bioactive polymers can be applied as blood and tissue compatible biodegradable materials in variable medical application such as tissue engineering and drug delivery system.

  • PDF

Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier

  • Cho, Eng-Haeng;Hah, Jong-Sik;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • 제26권1호
    • /
    • pp.37-44
    • /
    • 1992
  • The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 ${\mu}m$ in diameter and round in shape. $P_{50}$ value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.

  • PDF