• 제목/요약/키워드: Blood pressure monitor

검색결과 103건 처리시간 0.022초

휴대용 무선 응급 단말기 및 통합 시스템 개발 (Development of Portable Wireless Emergency Units and Integrated System)

  • 송미혜;명현석;이경중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2161-2162
    • /
    • 2006
  • In this study, we developed five mobile units and an integrated system which can manage vital signs from each unit using Bluetooth wireless communication. The five kinds of mobile unit were so designed that each has different function to be applied according to the condition of patient properly. The mobile units can measure ECG signal of single or 12 channel, blood pressure, pulse and SpO2 signal from a patient. Also, to reduce the uncomfortable measurement, several types of units such as belt type, wrist type and necklace type were designed. Our proposed system can integrate and monitor several biological signals from different patient by using Bluetooth wireless communication simultaneously. The developed system was evaluated in the simulated emergent situation and showed the system can monitor 5 patients in maximum according to the data quality. It showed the possibilities that the developed system can be used effectively for emergency situation or in- or out-hospital transport of patient. In future, with the combination of mobile communication technique, a patient who is in emergency situation can be provided with proper first-aid and a doctor can pile information of patient and give better diagnosis and treatments.

  • PDF

Use of ADMSTM during sedation for dental treatment of an intellectually disabled patient: a case report

  • Chi, Seong In;Kim, Hyun Jeong;Seo, Kwang-Suk;Yang, Martin;Chang, Juhea
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제16권3호
    • /
    • pp.217-222
    • /
    • 2016
  • Dental treatment is often performed under general anesthesia or sedation when an intellectually disabled patient has a heightened fear of treatment or has difficulty cooperating. When it is impossible to control the patient due to the severity of intellectual disability, conscious sedation is not a viable option, and only deep sedation should be performed. Deep sedation is usually achieved by propofol infusion using the target controlled infusion (TCI) system, with deep sedation being achieved at a slightly lower concentration of propofol in disabled patients. In such cases, anesthesia depth monitoring using EEG, as with a Bispectral Index (BIS) monitor, can enable dental treatment under appropriate sedation depth. In the present case, we performed deep sedation for dental treatment on a 27-year-old female patient with mental retardation and severe dental phobia. During sedation, we used BIS and a newly developed Anesthetic Depth Monitor for Sedation (ADMS$^{TM}$), in addition to electrocardiography, pulse oximetry, blood pressure monitoring, and capnometry for patient safety. Oxygen was administered via nasal prong to prevent hypoxemia during sedation. The BIS and ADMS$^{TM}$ values were maintained at approximately 70, and dental treatment was successfully performed in approximately 30 min.

Clinical Effects of Korean Ginseng, Korean Red Ginseng, Chinese Ginseng, and American Ginseng on Blood Pressure in Mild Hypertensive Subjects

  • Choi, Dong-Jun;Jung, Woo-Sang;Park, Seong-Uk;Han, Chang-Ho;Lee, Won-Chul;Cho, Ki-Ho
    • 대한한의학회지
    • /
    • 제27권4호
    • /
    • pp.198-208
    • /
    • 2006
  • Background : Ginseng has traditionally been used in oriental countries to recover vital energy from Qi deficiency, and has shown various biomedical effects in the scientific literature. Recent reports suggest that ginseng could regulate blood pressure (BP), but much controversy still remains. Therefore, we intended to assess the anti-hypertensive effect of several ginseng types frequently used in clinics. We also investigated the anti-hypertensive effect on Koreans and Chinese, and by the body type according to Sasang Constitution Medicine (SCM). Methods : The study subjects were recruited from mildly hypertensive patients who exhibited pre-hypertension(120/80 to 139/89 mmHg) and stage I hypertension (140/90 to 159/99 mmHg) in Korea and China. After assigning the subjects into a Korean, a Chinese, a red, and an American ginseng group by randomization, we prescribed ginseng at a dose of 4.5 g per day for 4 weeks. To assess the anti-hypertensive effect, we compared the mean of systolic and diastolic BP between before and after ginseng medication using a 24-hour ambulatory blood pressure monitor (24 hr ABPM. We also monitored adverse effect and laboratory findings to secure the subjects' safety. In addition, all of the subjects in Korea consulted a specialist of Sasang Constitution Medicine to identify their constitutional type. Results : There were 64 subjects treated with Korean ginseng, 58 treated with Chinese ginseng, 33 treated with red ginseng, and 64 treated with American ginseng. Korean, Chinese, and American ginseng all reduced subjects' BP; Korean and Chinese ginseng showed more effect. The secondary analysis on the subjects' nationality revealed that all of the ginseng types showed more significant anti-hypertensive effect in Chinese patients than in Koreans. The third analysis on the constitutional type of SCM showed there was no significant difference in the effectiveness and the safety of ginseng among the constitutional types. Conclusions : We suggest ginseng, especially Panax ginseng without any steaming-drying process, could be useful for mild hypertension. Further, ginseng is safe regardless of subjects' constitutional type or type of ginseng within a dosage of 4.5g per day.

  • PDF

천마추출물이 정상인의 뇌혈류에 미치는 영향 (Effect of Gastrodia Elata BL Water Extract on Human Cerebral Blood Flow using Transcranial Doppler)

  • 문상관;김영석;박성욱;정우상;고창남;조기호;배형섭
    • 대한한의학회지
    • /
    • 제26권1호
    • /
    • pp.115-122
    • /
    • 2005
  • Background and objective: Gastrodiae Rhizoma (GR), the rhizoma of Gastrodia elata BL., is one of the popular drugs to treat headache, dizziness, blackout, numbness of limbs, hemiplegia, facial paralysis, dysphrasia, and infantile convulsions. It has been reported that it provides an antihypertensive effect and lowers cerebrovascular resistance in animal experiments. However, there has been no data about these effects with human subjects. In this study, the author examined the effect of Gastrodiae water extracts on blood pressure and cerebrovascular reactivity in human subjects. Methods: We selected 16 normal volunteers, who were divided into 2 groups: Gastrodiae extract administration group and placebo (creamy powder) group. Using transcranial Doppler ultrasound, we monitored changes of mean flow velocity and breath-holding induced CO2 reactivity of middle cerebral artery in both groups. Mean blood pressure, heart rate and PETCO2 were measured using Compact Anesthesia Monitor. In both groups, all evaluation was performed during basal condition, and repeated at 30, 60, and 90 min after administration. Results: Gastrodiae extract decreased CO2 reactivity after administration, reaching the lowest level at 90 minutes $(-29.1\%\;vs.\;basal\;level)$, which showed significant difference compared with the placebo group (p = 0.004). In the placebo group, the pulse rates tended to decrease over time (at 90 minute, $-5.2\%$ vs. basal level) while in the Gastrodiae group the values showed nearly no change, which showed significant difference between both groups (p = 0.036). However, the changes of mean blood pressure and mean flow velocity did not show significant difference between both groups. Conclusion : This study demonstrated that Gastrodiae extract significantly decreased breath-holding induced CO2 reactivity. This result suggests that the clinical effect of Gastrodiae extract might be caused by increasing cerebral blood flow via dilation of cerebral resistant vessels instead of antihypertensive effect.

  • PDF

환자감시를 위한 모듈형 호흡 시스템의 구현 (The implementation of modular respiratory system for patient monitoring)

  • 박종억;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.503-506
    • /
    • 2001
  • 심전도 감시장치(electro-cardiography monitoring system)에 대한 연구는 국내외적으로 활발하게 이루어지고 있으나, 국내의 경우 환자 상태를 감시하는데 있어 중요한 요소인 호흡(respiration)에 관한 연구는 다소 미흡한 민이 있었다. 이번 연구는 환자의 상태를 감시하는데 있어 심전도, 혈압(brood pressure), 체온(temperature)과 더불어 중요한 요소로 여겨지는 호흡에 대한 감시장치로, 호흡 시 신체의 임피던스 변화를 이용하여 시스템을 구현함으로써, 심전도 측정과 병행하여 사용할 수 있는 장점이 있다. 특히, 임피던스를 이용한 환자감시장치의 경우 중추신경 마비 둥의 원인에 의한 무호흡 감지에 효과적으로 응급실 등에서 유용하게 사용된다. 구현된 시스템은 아날로그 부와 디지털 부의 잡음간섭 린 환자의 안전을 도모하기 위해 회로를 전기적으로 분리하여 설계하였다. 아날로그 부의 구성은 고주파 신호를 발생하는 정현파 발생부, 반송파로부터 인체의 임피던스 변화성분을 추출하고 증폭하는 증폭부, 기저대역으로 변환하기 위한 복조 및 아날로그 필터부로 구성되어 있다. 디지털 부는 아날로그-디지탈 변환기 및 디지털 필터, 생체정보 추출부로 구성되어있다. 본 연구에서 구현된 시스템은 심전도 감시장치의 전극을 공용으로 사용할 수 있도록 구성되었으며, 호흡 감시장치에 대한 기반기술 획득을 통해 다기능환자감시장치의 개발에 바로 응용 될 수 있다.

  • PDF

Computer Models on Oxygenation Process in the Pulmonary Circulation by Gas Diffusion

  • Chang, Keun-Shik;Bae, Hwang
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권1호
    • /
    • pp.9-16
    • /
    • 2006
  • In this article we introduce computer models that have been developed in the past to determine the concentration of metabolic gases, the oxygen and carbon dioxide, along the pulmonary circulation. The terminal concentration of these gases in the arterial blood is related with the total change of the partial pressure of the same gases in the alveoli for the time beginning with inspiration and ending with expiration. It is affected not only by the ventilation-perfusion ratio and the gas diffusion capacity of the lung membrane but also by the pulmonary defect such as shunt, dead space, diffusion impairment and ventilation-perfusion mismatch. Some pathological pulmonary symptoms such as ARDS and CDPD can be understood through the mathematical models of these pulmonary dysfunctions. Quantitative study on the blood oxygenation process using various computer models is therefore of foremost importance in order to monitor not only the pulmonary health but also the cardiac output and cell metabolism. Reviewed in this paper include the basic and advanced methods that enable numerical study on the gas exchange and on the arterial oxygenation process, which might depend on the various heart and lung physiological conditions listed above.

  • PDF

Acute kidney injury and continuous renal replacement therapy in children; what pediatricians need to know

  • Cho, Myung Hyun;Kang, Hee Gyung
    • Clinical and Experimental Pediatrics
    • /
    • 제61권11호
    • /
    • pp.339-347
    • /
    • 2018
  • Acute kidney injury (AKI) is characterized by abrupt deterioration of renal function, and its diagnosis relies on creatinine measurements and urine output. AKI is associated with higher morbidity and mortality, and is a risk factor for development of chronic kidney disease. There is no proven medication for AKI. Therefore, prevention and early detection are important. Physicians should be aware of the risk factors for AKI and should monitor renal function in high-risk patients. Management of AKI includes optimization of volume status and renal perfusion, avoidance of nephrotoxic agents, and sufficient nutritional support. Continuous renal replacement therapy is widely available for critically ill children, and this review provides basic information regarding this therapy. Long-term follow-up of patients with AKI for renal function, blood pressure, and proteinuria is recommended.

Implementation of sensor network based health care system for diabetes patient

  • Kim, Jeong-Won
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.454-458
    • /
    • 2008
  • It can improve human being's life quality that all people can have more convenient medical service under pervasive computing environment. For a pervasive health care application for diabetes patient, we've implemented a health care system, which is composed of three parts. Various sensors monitor both outer and inner environment of human such as temperature, blood pressure, pulse, and glycemic index, etc. These sensors form zigbee based sensor network. And medical information server accumulates sensing values and performs back-end processing. To simply transfer these sensing values to a medical team is a low level's medical service. So, we've designed a new service model based on back propagation neural network for more improved medical service. Our experiments show that a proposed healthcare system can give high level's medical service because it can recognize human's context more concretely.

An U-Healthcare Implementation for Diabetes Patient based on Context Awareness

  • Kim, Jeong-Won
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.412-417
    • /
    • 2009
  • With ubiquitous computing aid, it can improve human being's life quality if all people have more convenient medical service under pervasive computing environment. In this paper, for a pervasive health care application for diabetes patient, we've implemented a health care system, which is composed of three parts. Various sensors monitor both outer and inner environment of human such as temperature, blood pressure, pulse, and glycemic index, etc. These sensors form zigbee-based sensor network. And as a backend, medical information server accumulates sensing data and performs back-end processing. To simply transfer these sensing values to a medical team may be a low level's medical service. So, we've designed a model with context awareness for more improved medical service which is based on ART(adaptive resonance theory) neural network. Our experiments show that a proposed healthcare system can provide improved medical service because it can recognize current context of patient more concretely.

ECG-NIBP-$SpO_2$ 환자감시장치 개발 (Development of ECS-NIBP-$SpO_2$ Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF