• Title/Summary/Keyword: Blood pressure measurement system

Search Result 100, Processing Time 0.024 seconds

Implementation of PTT Change Monitoring System According to Exercise Intensity (PTT기반 운동 강도 모니터링 시스템 구현)

  • Lee, Ji-Su;Kim, Dong-Chan;Lee, Gyeong-Tack;Kim, Gyeong-Seop;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2020
  • Cardiovascular disease is the leading cause of death worldwide and is caused by a variety of causes. The highest risk factor for cardiovascular disease is high blood pressure, which has no obvious symptoms, but if left untreated, it causes several complications. In order to treat hypertension, medication and regular exercise are required. In people with high blood pressure, excessive physical activity can put a great strain on the heart and lead to cardiovascular disease. Therefore, there is a need for an exercise intensity monitoring system through PTT measurement that can perform exercise at an appropriate intensity. In this study, we implemented a PTT change monitoring system according to exercise intensity by calculating PTT through ECG and PPG measurement. The implemented system differentiates the R-peak of the ECG and P-peak of the PPG, and calculates the PTT using the time difference between R-peak and P-peak. A running experiment was conducted to monitoring PTT change according to exercise intensity. As a result of the experiment, low intensity PTT is 0.313s, moderate is 0.220s, high is 0.188s, it was confirmed that the PTT decreased as the exercise increase increased.

Measurement of cell aggregation characteristics by analysis of laser-backscattering in a microfluidic rheometry

  • Shin, Se-Hyun;Hou, J.X.;Suh, Jang-Soo
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.61-66
    • /
    • 2007
  • The aggregation characteristics of red blood cells (RBCs) are known as important factors in the microvascular flow system, and increased RBC aggregation has been observed in various pathological diseases, such as thrombosis and myocardial infarction. This paper describes a simple microfluidic device for measuring the RBC aggregation by integrating a microfluidic slit rheometry and laser-backscattering technique. While a decreasing-pressure mechanism was applied to the microfluidic rheometry, a syllectogram (the light intensity versus time) showed an initial increase and a peak caused by the high shear stress-induced disaggregation, immediately followed by a decrease in the light intensity due to RBC aggregation. The critical shear stress (CST) corresponding to the peak intensity was examined as a new index of the RBC aggregation characteristics. The CST of RBCs increased with increasing aggregation-dominating protein (fibrinogen) in the blood plasma. The essential feature of this design was the combination of the rheometric-optic characterization of RBC aggregation with a microfluidic chip, which may potentially allow cell aggregation measurements to be easily carried out in a clinical setting.

Development of Portable Wireless Emergency Units and Integrated System (휴대용 무선 응급 단말기 및 통합 시스템 개발)

  • Song, M.H.;Myoung, H.S.;Lee, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2161-2162
    • /
    • 2006
  • In this study, we developed five mobile units and an integrated system which can manage vital signs from each unit using Bluetooth wireless communication. The five kinds of mobile unit were so designed that each has different function to be applied according to the condition of patient properly. The mobile units can measure ECG signal of single or 12 channel, blood pressure, pulse and SpO2 signal from a patient. Also, to reduce the uncomfortable measurement, several types of units such as belt type, wrist type and necklace type were designed. Our proposed system can integrate and monitor several biological signals from different patient by using Bluetooth wireless communication simultaneously. The developed system was evaluated in the simulated emergent situation and showed the system can monitor 5 patients in maximum according to the data quality. It showed the possibilities that the developed system can be used effectively for emergency situation or in- or out-hospital transport of patient. In future, with the combination of mobile communication technique, a patient who is in emergency situation can be provided with proper first-aid and a doctor can pile information of patient and give better diagnosis and treatments.

  • PDF

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Measurement of Secondary Electron Emission Coefficient and Bimolecular Valence Band Energy Structure of Erythrocyte with and Without Bioplasma Treatment

  • Lee, Jin-Young;Baik, Guyon;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.483-483
    • /
    • 2012
  • Recently, nonthermal bioplasma has been attracted by researchers due to their potentials to modulate cellular functions resulting in changes of biomolecular electron band structures as well as cell morphologies. We have investigated the secondary electron emission characteristics from the surface of the erythrocyte, i.e., red blood cell (RBC) with and without the nonthermal bioplasma treatment in morphological and biomolecular aspects. The morphologies have been controlled by osmotic pressure and biomolecular structures were changed by well known reactive oxygen species. Ion-induced secondary electron emission coefficient have been measured by using gamma-focused ion beam (${\gamma}$-FIB) system, based on the quantum mechanical Auger neutralization theory. Our result suggests that the nonthermal bioplasma treatment on biological cells could result in change of the secondary electron emission coefficient characterizing the biomolecular valence band electron energy structures caused by the cell morphologies as well as its surface charge distributions.

  • PDF

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF

A STUDY ON IMPLEMENTATION OF OUTWARD AGING AND HEALTH-STATE MONITORING SYSTEM BASED ON IMAGE PROCESSING (영상처리에 기반한 노인 대상 외양적 노화 및 건강 상태 모니터링 시스템에 관한 연구)

  • Hwang, Kun-Su;Kil, Se-Kee;Shen, Dong-Fan;Min, Hong-Ki;Lee, Eung-Hyuk;Hong, Seung-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.881-882
    • /
    • 2006
  • According as society looks graying trend gradually, more shaped system that can achieve measuring health-state of old people more harmoniously construction required in field of old people's welfare and medical treatment. Health-state is measured by two methods of contact and non-contact. The first, for example measurement of blood pressure or electrocardiogram, requires that measuring equipments are attached on human body but the second, for example X-Ray or MRI, is not. But both of methods are have some of defect, for example attaching equipments, needing of the special equipments or the necessary time, etc. Therefore desirable method of monitoring system must have minimum interrupt about daily life. This study suggest the system that can monitor the user, especially old people's outward aging and health-state by use the PAN TILTER and CCD camera.

  • PDF

Obesity Indices and Plasma Total Antioxidant Status in Hypertensive Elderly Living in Ulsan Area (울산 지역 고혈압 노인의 비만 지표 및 혈중 총항산화도)

  • Kim Jung-Hee;Kim Mi-Joung;Kwak Ho-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.2
    • /
    • pp.279-288
    • /
    • 2006
  • The role of free radicals in the progression of many diseases and aging has been given a great attention and total antioxidant status (TAS) has shown to be reduced with aging. The incidence of hypertension has shown to be relatively high in the aged population, and it is known to be associated with increased obesity and oxidative stress. The aim of this study was to examine the obesity indices and the total antioxidant status in hypertensive elderly (64y$\alpha$-tocopherol, $\beta$-carotene and ascorbic acid did not show their significant correlations with TAS. These results showed that the hypertensive elderly are prone to be obese and to have increased TAS. Due to unknown factors affecting TAS values, measurement of plasma TAS as a sole indicator of total antioxidant capacity is limited to fully understanding changes in the body's free radical trapping power. However, the results from the current study may suggest that hypertension and/or obesity might increase oxidative stress, followed by increased the body's total antioxidant defense system.

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.