• Title/Summary/Keyword: Blood pressure measurement

Search Result 396, Processing Time 0.028 seconds

다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교 (Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure)

  • 송효숙;전태국;최은정;김미정
    • 기본간호학회지
    • /
    • 제8권3호
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

지역사회 성인의 혈압측정횟수 및 연령에 따른 혈압의 차이 (Differences in Blood Pressure among Adults in the Community according to Blood Pressure Measurement Time and Age)

  • 박경연
    • Journal of Korean Biological Nursing Science
    • /
    • 제21권4호
    • /
    • pp.275-282
    • /
    • 2019
  • Purpose: This study aimed to identify the differences in blood pressure among adults in the community according to age and time of the blood pressure measurement. Methods: This was a secondary analysis study, using data from a 2015 community health survey, conducted by the Korea Centers for Disease Control and Prevention. The data of three-time-measured blood pressure were collected from 337 subjects, 25, 35, 45, 55, 65, 75 years old, which are median ages by each age group. Results: The primary systolic pressure was significantly higher than the secondary systolic pressure (t= 3.46, p= .001) and the tertiary systolic pressure (t= 4.83, p= .001). The secondary systolic pressure was higher than the tertiary measurement (t= 2.05, p= .041). There was no significant difference between the three-time-measured values for diastolic pressure. There was a significant interaction between measurement times and age in the systoic blood pressure readings (F= 1.95, p= .036). However, there was no significant interaction between measurement times and age in the diastolic blood pressure readings (F= 1.03, p= .418). Conclusion: The findings suggest that attention must be paid to the use of blood pressure values in studies or one-time-measured clinical blood pressure values. In particular, the differences in systolic pressure readings taken at different times in the older age groups were significant. Therefore, it is more important to carefully assess blood pressure in adults over the age of 45 compared to other age groups.

웹 기반 학습 프로그램이 혈압측정에 대한 자기효능감, 지식 및 수행능력에 미치는 효과 (Effectiveness of web based learning program on self efficacy, knowledge, and competence in measurement of blood pressure)

  • 이숙희
    • 기본간호학회지
    • /
    • 제19권1호
    • /
    • pp.66-73
    • /
    • 2012
  • Purpose: This study was done to identify the effectiveness of a web based learning program on self efficacy, knowledge, and competence in measurement of blood pressure in college nursing students. Method: This study was an experimental research study. Data were collected from April 20 to June 1. 2011. The participants were 68 first year nursing students (experimental group 37, control group 31). The collected data were analyzed with the PASW 18.0 program, using ${\chi}^2$-test, t-test, and Cronbach's ${\alpha}$. Results: The mean score for self efficacy in blood pressure measurement in the experimental group was 61.9 and in the control group 60.7. This result was statistically significant (t=3.301, p=.002). The mean score for knowledge of blood pressure measurement in the experimental group was 11.5 and in the control group 10.8. This result was statistically significant (t=2.910, p=.005). But effectiveness of competence in blood pressure measurement was not significant. Conclusion: The study results show that the web based learning program was effective for self efficacy and knowledge in blood pressure measurement but not for competence indicating.-a need to develop strategies to improve competence in blood presessure measurement for these students.

응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증 (Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency)

  • 전재인
    • 문화기술의 융합
    • /
    • 제8권3호
    • /
    • pp.91-97
    • /
    • 2022
  • 이 연구의 목적은 이동하는 구급차에서 혈압계의 신뢰성을 검증하기 위해 다양한 도로 상황에서 수동 및 자동혈압계를 이용하여 혈압 및 시간 측정값을 분석하는 것이다. 첫째, 비포장 도로에서 수동 혈압계 촉진 결과 수축기 혈압 편차가 5mmHg로 나타났다. 그러나 자동 혈압계는 2개의 측정 실패, 1개의 판독 실패를 보여주었으며 측정된 수축기 혈압 편차는 35mmHg였다. 측정 시간은 자동 혈압계보다 평균 102초 빨랐다. 둘째, 과속방지턱을 넘을 때 수동 혈압계의 촉진은 130mmHg로 일정하게 유지되었다. 그러나 자동 혈압계의 수축기 혈압 편차는 52mmHg였다. 측정 시간은 자동 혈압계보다 평균 61초 빨랐다. 마지막으로 급커브 도로에서 수동 혈압계 촉진 결과 수축기 혈압 편차는 5mmHg로 나타났다. 자동 혈압계는 판독 실패가 1회 있었고 측정된 수축기 혈압 편차는 21mmHg였다. 측정 시간은 수동 혈압계가 자동 혈압계보다 101초 빠른 것으로 나타났다. 그 결과 응급상황시 이송중인 구급차에서 수동 혈압계는 혈압 측정이 일정하고 측정 시간이 짧아 높은 신뢰도를 보였다.

커프크기와 측정부위에 따른 혈압측정치 비교 연구 (A Comparative Study of Blood Pressure According to Cuff Size and Measurement Site)

  • 송미령;김은경
    • 기본간호학회지
    • /
    • 제16권1호
    • /
    • pp.6-13
    • /
    • 2009
  • Purpose: The purpose of this study was to identify differences in blood pressure according to cuff size and measurement sites of the participants. Method: The participants consisted of 50 women and 50 men whose upper arm circumference was $26\sim30cm$. They had no chronic illness and gave consent to participate. Blood pressure of the wrist was measured in the sitting position, the upper arm with a standard cuff, large and small cuffs were used for measurement in supine position and the thigh in prone position. The data were analyzed with paired t-test using SPSS 12.0 program. Result: The data for the upper arm showed a difference in systolic and diastolic blood pressure depending on the site of measurement. There was a significant difference between measurements with a standard cuff and measurements with large and small cuffs. The systolic blood pressure of the wrist and the thigh were significantly lower than that of the upper arm. Conclusion: These results suggest that the selection of an appropriate cuff is an essential element in ensuring accuracy when measuring blood pressure and differences in systolic blood pressure for the upper arm, wrist and thigh indicate the need to record the measuring site when measuring blood pressure.

  • PDF

응급구조(학)과 학생의 혈압측정 모형을 활용한 혈압측정 정확도 (Accuracy of blood pressure measurements taken using a blood pressure simulator by paramedic students)

  • 최은숙
    • 한국응급구조학회지
    • /
    • 제19권1호
    • /
    • pp.7-17
    • /
    • 2015
  • Purpose: We gathered information for the development of a blood pressure measurement education program by analyzing the accuracy of reading taken using a blood pressure simulator by Korean paramedic students. Methods: Data from 131 students were collected in November 12-20, 2013, and April 2-4, 2014. A 27-item questionnaire was administered, the accuracy of measurements confirmed using a blood pressure simulator (BT-CEAB), and the data analyzed (SPSS v 21.0). Results: The accuracy of systolic and diastolic blood pressure readings (${\leq}2mmHg$) was relatively low (27.5%). The mean blood pressure knowledge score was 67.61 points; significant differences were noted considering the sex (p = .001), hours of practice (p =.007), numbers of practice (p = .001), and reported self-confidence (p = .026). The blood pressure measurement accuracy group did not show a significant difference in its knowledge of blood pressure (p = .198). Conclusion: Most subjects needed several practice sessions to master the skill of measuring blood pressure. The feedback provided by individual assessment and the practice education program will serve as the basis for clinical and prehospital practice.

부분최소자승법을 이용한 혈압 측정에 관한 연구 (A Study on Measurement of Blood Pressure by Partial Least Square Method)

  • 김용주;남은혜;최창현;김종덕
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.438-445
    • /
    • 2008
  • The purpose of this study was to develop a measurement model based on PLS (Partial least square) method for blood pressures. Measurement system for blood pressure signals consisted of pressure sensor, va interface and embedded module. A mercury sphygmomanometer was connected with the measurement system through 3-way stopcock and used as reference of blood pressures. The blood pressure signals of 20 subjects were measured and tests were repeated 5 times per each subject. Total of 100 data were divided into a calibration set and a prediction set. The PLS models were developed to determine the systolic and the diastolic blood pressures. The PLS models were evaluated by the standard methods of the British Hypertension Society (BHS) protocol and the American Association for the Advancement of Medical Instrumentation (AAMI). The results of the PLS models were compared with those of MAA (maximum amplitude algorithm). The measured blood pressures with PLS method were highly correlated to those with a mercury sphygmomanometer in the systolic ($R^2=0.85$) and the diastolic blood pressure ($R^2=0.84$). The results showed that the PLS models were the effective tools for blood pressure measurements with high accuracy, and satisfied the standards of the BHS protocol and the AAMI.

측정 횟수 및 방문 횟수에 따른 혈압 변화 (The Change of Blood Pressure according to the Number of Measurements and the Number of Visits)

  • 박지은;이민희;류연희;류연;정희정;홍상훈;이승덕;김남권;최선미
    • 한국한의학연구원논문집
    • /
    • 제18권3호
    • /
    • pp.111-118
    • /
    • 2012
  • Objective : The aim of this study was to investigate the number of measurements and visits for blood pressure measurement. We also analyzed the change of blood pressure based on the measurement method and measurement interval. Methods : Data of three clinical trials evaluating the effect of acupuncture, moxibustion, and qigong for pre and mild essential hypertension were used. Blood pressure was measured 3 times each visit with 1 or 5 minutes interval, and it was checked until $3^{rd}$ visit. Two trials used sphygmomanometer and another one trial used automatic device for blood pressure measurement. Results : The mean difference between $1^{st}$ and $2^{nd}$, and $2^{nd}$ and $3^{rd}$ measurement were significant in systolic (p<0.001) and diastolic blood pressure (p<0.001). However, in automated measurement or measuring with 1 minute interval, the difference between $2^{nd}$ and $3^{rd}$ was not significant. The mean of $1^{st}$ and $2^{nd}$ measurements was also significantly different from the mean of all three measurements in both systolic (p<0.001) and diastolic blood pressure (p<0.001). While the difference between each visit was not significant in diastolic blood pressure, the systolic blood pressure difference was significant between $1^{st}$ and $2^{nd}$ visit in automated and manual measurement. Conclusion : The mean of two measurements and three measurements were significantly different. The change of blood pressure was different according to the method and interval of blood pressure measurement.

가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계 (Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.281-286
    • /
    • 2003
  • 혈압은 사람의 건강상태를 알 수 있는 가장 기본적인 의학적 파라메터 중 하나이며, 오실로메트릭 방법을 사용한 혈압측정 시스템은 팔 동맥에서 커프를 통해 나타나는 압력을 측정함으로써 혈압수치를 비침습적으로 모니터링 하는 장치이다. 된 논문에서는 커프에 공기를 주입하면서 혈압을 측정하는 가압식 손목형 혈압측정 시스템을 설계하였다 설계한 혈압측정 시스템은 전원부와 압력을 가하는 공기주머니를 포함하는 커프, 신호검출부, 신호처리부, 무선 송수신부 그리고 디스플레이부로 구성된다. 설계한 자동 혈압측정 시스템은 기존에 일반적으로 사용되고 있는 자동혈압측정 시스템과의 수축기, 이완기 혈압 및 심박동수의 비교분석을 통해 신뢰성을 평가하였다. 수축기 혈압과 이완기 혈압을 결정하기 위해 MAA (Maximum Amplitude Algorithm)를 사용하였고, 적용한 특성비율은 0.436. 0.671이 었다.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권4호
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.