• Title/Summary/Keyword: Blood flow rate

Search Result 488, Processing Time 0.028 seconds

Effect of Unilateral Renal Arterial Infusion of Angiotensin II on Renal Function and Renin Secretion in Unanesthetized Rabbit (신동맥내 투여한 Angiotensin II가 신장기능 및 Renin 분비에 미치는 영향)

  • Kim, Jong-Hun;Kang, Nam-Poo;Kim, Young-Jin;Kim, Suhn-Hee;Cho, Kyung-Woo
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.363-375
    • /
    • 1989
  • It has been well known that peripheral infusion of angiotensin II results in an increase of blood pressure, and an elevation of aldosterone secretion, and an inhibition of renin relase. However, the direct effect of angiotensin II on renal function has not been clearly established. In the present study, to investigate the effect of angiotensin II on renal function and renin release, angiotensin II (0.3, 3 and 10 ng/kg/min) was infused into a unilateral renal artery of the unanesthetized rabbit and changes in renal function and active and inactive renin secretion rate (ARSR, IRSR) were measured. In addition, to determine the relationship between the renal effect of angiotensin II and adenosine, the angiotensin II effect was evaluated in the presence of simultaneously infused 8-phenyltheophylline (8-PT, 30 nmole/min), adenosine A 1 receptor antagonist. Angiotensin II infusion at dose less than 10 ng/kg/min decreased urine flow, clearances of para-amino-hippuric acid and creatinine, and urinary excretion of electrolytes in dose-dependent manner. The changes in urine flow and sodium excretion were significantly correlated with the change in renal hemodynamics. Infusion of angiotensin II at 10 ng/kg/min also decreased ARSR, but it has no significant effect on IRSR. The change in ARSR was inversely correlated with the change in IRSR. The plasma concentration of catecholamine was not altered by an intarenal infusion of angiotensin II. In the presence of 8-PT in the infusate, the effect of angiotensin II on renal function was significantly attenuated, but that on renin secretion was not modified. These results suggest that the reduction in urine flow and Na excretion during intrarenal infusion of angiotensin II was not due to direct inhibitions of renal tubular transport systems, but to alterations of renal hemodynamics which may partly be mediated by the adenosine receptor.

  • PDF

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

Clinical Experience of Long-term Home Oxygen Therapy (재택산소요법을 받고 있는 환자들에 대한 임상 관찰)

  • Lee, Young-Suk;Cha, Seung-Ick;Han, Chun-Duk;Kim, Chang-Ho;Kim, Yeun-Jae;Park, Jae-Yong;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.283-291
    • /
    • 1993
  • Background: Long-term low flow oxygen therapy not only increases survival, but also improves the quality of life in patients with chronic obstructive pulmonary disease (COPD) with chronic hypoxemia. For the assessment and improvement of the status of home oxygen therapy, we analyzed clinical experience of 26 patients who have been administered low flow oxygen at home. Method: Twenty-six patients (18 men and 8 women) who have been received long-term oxygen therapy (LTOT) at home were examined. We reviewed physical characteristics, clinical history, pulmonary function test, ECG, arterial blood gas analysis, hemoglobin and hematocrit, types of oxygen devices, inhalation time per day, concentration of administered $O_2$, duration of $O_2$ therapy, and problems in the home oxygen therapy. Results: The underlying diseases of patients were COPD 14 cases, far advanced old pulmonary tuberculosis 9 cases, bronchiectasis 2 cases, and idiopathic pulmonary fibrosis 1 case. The reasons for LTOT at home were noted for cor pulmonale 21 cases, for dyspnea on exertion and severe ventilatory impairment 4 cases, and for oxygen desaturation during sleep 1 case. The mean values of aterial blood gas analysis before home oxygen therapy were $PaO_2$ 57.7 mmHg, $PaCO_2$ 48.2 mmHg, and $SaO_2$ 87.7%. And the mean values of each parameters in the pulmonary function test were VC 2.05 L, $FEV_1$ 0.92 L, and $FEV_1$/FVC% 51.9%. Nineteen patients have used oxygen tanks as oxygen devices, 1 patient oxygen concentrator, 2 patients oxygen tank and liquid oxygen, and other 4 patients oxygen tank together with portable oxygen. The duration of oxygen therapy was below 1 year in 3 cases, 1~2 years in 15 cases, 3~5 years in 6 cases, 9 years in 1 case, and 10 years in 1 case. All patients have inhalated oxygen with flow rate less than 2.5 L/min. And only 10 patients have inhalated oxygen more than 15 hours per day, but most of them short time per day. Conclusion: For the effective oxygen administration, it is necessary that education for long-term low flow oxygen therapy to patients, their family and neighbor should be done, and also the institutional backup for getting convenient oxygen devices is required.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Blood Gas Management of a Membrane Oxygenator During Cardiac Surgery with Deep Hypothermic Circulatory Arrest (막형산화기에 의한 저체온 순환정지 심장수술시 혈액가스 조절)

  • Kim, W. G.;Lim, C.;Baek, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.279-284
    • /
    • 1998
  • Deep hypothermic circulatory arrest(DHCA), in which systemic temperatures of 2$0^{\circ}C$ or less are used to allow temporary cessation of the circulation, is an useful adjunct in cardiac surgery. Because man in natural circumstances is never exposed to the extreme hypothermic condition, however, one of the controversial aspects is appropriate blood gas management($\alpha$STAT versus PH-STAT) during DHCA. This study aims to compare $\alpha$STAT with PH-STAT management for control of blood gases in experimental cardiopulmonary bypass(CPB) circuits with a membrane oxygenator. Fourteen young pigs were assigned to one of two strategies of gas manipulation. After a median sternotomy, CPB was established. Core cooling was initiated and continued until nasopharyngeal temperature fell below 2$0^{\circ}C$. The flow rate was set at 2,500 ml/min. Once their temperatures were below 2$0^{\circ}C$, the animals were subjected to circulatory arrest for 40mins. During cooling, blood gas was maintained according to either $\alpha$$\alpha$STAT or pH-STAT strategies. After DHCA, the body was rewarmed to normal body temperature. Arterial blood gases were measured before the onset of CPB, before cooling, before DHCA, at the point of 27$^{\circ}C$ during re-warming, on completion of re-warming. Cooling time was significantly shorter in $\alpha$-STAT than PH-STAT strategy, while there was no significant differences in rewarming time between two groups. Carbon dioxide was added between 5.5 and 3.0% in PH-STAT, while no carbon dioxide was added in $\alpha$STAT management. Amounts of oxygen administration were gradually lowered as temperature decreased. In this way, criteria of PH, PaCO, and PaO adjustments were satisfied in both $\alpha$STAT and PH-STAT management groups.

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Study on Heart Rate Variability Characteristics of Cold Hypersensitivity of Hands and Feet Patients (수족냉증 환자의 HRV 특성연구)

  • Pak, Yeon-Kyoung;Park, Kang-In;Park, Kyoung-Sun;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.1
    • /
    • pp.92-101
    • /
    • 2015
  • Objectives: Heart Rate Variability (HRV) is a diagnostic tool for assessing the function of the autonomic nervous system. Although studies on the HRV characteristics of the cold hypersensitivity of hands and feet have been done, no study has compared HRV characteristics of cold hypersensitivity of hands and feet patients to that of normal Korean women. For this reason, this study compared the HRV characteristics of cold hypersensitivity of hands and feet patients and normal Korean women. Methods: We studied 130 cold hypersensitivity of hands and feet patients who visited Kyung Hee University Hospital at Gangdong from 01 March 2011 to 11 August 2013. We measured HRV of Each patient. Patients are divided into under 29 years old, 30~39 years old, 40~49 years old and over 50 years old with age. Patient's HRV results are compared to that of normal Korean women in each age group. Results: In each age group, cold hypersensitivity of hands and feet patients' LF/HF was statistically lower than that of normal Korean women. Conclusions: HRV characteristics and symptoms of cold hypersensitivity of hands and feet is similar to that of cold induced vasodilation (CIVD). So, cold hypersensitivity of hands and feet can be considered as abnormal condition that CIVD is continued. More studies on measuring of blood flow of cold hypersensitivity of hands and feet patients are necessary.

Effect of Do-In (Prunus persica L. BATSCH) Water Extract (PPE) on Concentration of Extracellular Acetylcholine in the Rat Hippocampus

  • Gong Dae-Jong;Kim Geun-Woo;Koo Byung-Soo
    • The Journal of Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.1-7
    • /
    • 2004
  • Objective : This study was designed to examine the effects of orally administered Prunus persica water extract (PPE), which is used as herbal medicine, for treatment of Yu Xue (stasis of blood) and tacrine on the basal concentration of extracellular acetylcholine in the hippocampus of rats. Methods: To investigate the effects of PPE and tacrine on concentration of extracellular acetylcholine in the hippocampus of rats, the microdialysis technique, under the same experimental conditions, was used. And we used male Wistar rats which were 7 weeks of age and 210-290 g. PPE was extracted with boiling water, and the rats were anesthetized with pentobarbital Na. Their skulls were exposed and a hole was drilled for implantation of a microdialysis probe. In order to increase the recovery of acetylcholine, a probe with a long membrane was used. One day after surgery, the microdialysis probe was perfused with Ringer's solution at a flow rate of 1.5 l/min. The acetylcholine concentration in dialysis samples was measured by high-performance liquid chromatography (HPLC) with electrochemical detection. AChE activity was measured using the radiometric method, as described by Sherman. Results : The comparative effects of PPE and tacrine on hippocampal extracellular acetylcholine concentration was that these cholinesterase inhibitors produced dose-dependent increases in the extracellular acetylcholine concentration. And the effect of PPE and tacrine on rat brain AChE activity was that PPE produced maximal inhibition at 1 h after administration, when AChE activity was 44% of the intact level. AChE activity gradually recovered thereafter, and reached 78% of the intact level at 12 h after administration. Conclusion : In this study, PPE has a potent activity and a long-lasting effect on the central cholinergic system, in terms of the basal concentration of extracellular acetylcholine in the hippocampus and the AChE activity in the brain of rats. And oral administration of PPE increased dose-dependently the basal concentration of extracellular acetylcholine in the hippocampus of rats. PPE may be one of the more useful cholinesterase inhibitors for the treatment of Alzheimer's disease.

  • PDF

A Microfluidic Chip-Based Creatinine Filtration Device (마이크로 플루이딕 칩을 기반으로 한 크레아티닌 여과장치)

  • Lee, Sack;Shin, Dong-Gyu;Nguyen, Thanh Qua;Park, Woo-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.921-925
    • /
    • 2015
  • The number of people suffering from renal disease increases every year. One of the most common treatments (clinical care options) for renal diseases is hemodialysis. However it takes a long time and has a high cost. Therefore, the importance of artificial kidney research has risen. Filtering creatinine from blood is one of the prime renal functions. Thus, we designed a novel two channel microfluidic chip focused on that function. In order to bond the individual polydimethylsiloxane layers, we have developed a housing system using acrylic plastic frame. This method has significant advantages in changing filter membranes. We use anodic aluminum oxide for the filter membrane. We analyzed the difference in the absorbance values for various creatinine concentrations using the Jaffe reaction. For the purpose of acquiring a standard equation to quantify the creatinine concentration, we interpolated the measured data and confirmed the concentration of the filtered solution. Through this experiment, we determined how the filtration efficiency depended on the flow rate and creatinine concentration.

Influence of Prostaglandin $F_{2{\alpha}}$ given intracerebroventricularly on the renal function of the rabbits (가토(家兎)의 신장기능(腎臟機能)에 미치는 측뇌실내(側腦室內) Prostaglandin $F_{2{\alpha}}$의 영향(影響))

  • Kook, Young-Johng;Ko, Kwang-Hoo
    • The Korean Journal of Pharmacology
    • /
    • v.12 no.2 s.20
    • /
    • pp.43-49
    • /
    • 1976
  • The facts that $PGE_2$ produced diuresis in the rabbit when given into a lateral ventricle of the brain and that $PGF_{2{\alpha}}$ is abundantly found in the brain prompted us to investigate the effects of $PGF_{2{\alpha}}$ introduced directly into the ventricle on the renal function. $PGF_{2{\alpha}}$ given intraventriculary in doses of $10{\mu}g\;and\;100{\mu}g$ elicited prompt diuresis, 10-fold increase of sodium excretion and two-fold increment of potassium excretion. Free water reabsorption also increased along with the increased osmolar clearance. Neither renal plasma flow nor glomerular filtration rate did change significantly. This, along with the fact that the percentage of reabsorbed sodium filtered decreased from 99.5 to 93.9, indicates the tubular site of the diuretic and natriuretic action. Atropine pretreatment did not influence the renal effects of intraventricular $PGF_{2{\alpha}}$. Intravenously administered $PGF_{2{\alpha}}$ in doses of 30 to $100{\mu}g$ did not produce any significant change in renal function. Intraventricular $PGF_{2{\alpha}}$ had no effect on the systemic blood pressure, whereas intravenous administration brought about a transient hypotension. These observations suggest that $PGF_{2{\alpha}}$ induces diuresis and natriuresis via central mechanism, that the site of the action resides in renal tubules, and that the reabsorption of sodium is inhibited in the proximal tubule, possibly through mediation of certain humoral agent. Overall, it is suggested that $PGF_{2{\alpha}}$ might play a roll in regulating renal function through the center.

  • PDF