• Title/Summary/Keyword: Blood cancer

Search Result 1,551, Processing Time 0.029 seconds

Comparison Study of the Pulmonary Function and Serum Carboxyhemoglobin Level Between the Traffic Policmen and Clerk Policemen (교통경찰과 비 교통경찰의 폐기능과 혈중 Carboxyhemoglobin 수치에 대한 비교연구)

  • Kim, Sung Min;Cheon, Gyu Rak;Kim, Young Wook;Kim, Joon Hyung;Lee, Ho Hak;Hong, Soon Chang;Lee, Seung Hee;Park, Sang Joon;Chung, Joon Oh;Kim, Yun Kwon;Kim, So Yon;Kim, Young Jung;Cho, Min Koo;Lee, Gwon Jun;Lee, Kyung In
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.560-569
    • /
    • 2003
  • Background : A large number of pollutants such as sulfur dioxide, nitric oxide, carbon monoxide, particulate matter, and ozone influence on the body. These pollutants put a burden on the lung and the sequelae resulting from the oxidative stress are thought to contribute to the development of fibrotic lung disease, emphysema, chronic bronchitis and lung cancer. Also, carbon monoxide generated from the incomplete combustion of carbon-containing compounds is an important component of air pollution caused by traffic exhaust fumes and has the toxic effect of tissue hypoxia and produce various systemic and neurologic complications. The objective of this study is to compare the difference of pulmonary function and serum carboxyhemoglobin(CO-Hb) level between the traffic policemen and clerk policemen. Method : Three hundred and twenty-nine of traffic policemen, and one hundred and thirty clerk policemen were included between 2001 May and 2002 August. The policemen who took part in this study were asked to fill out a questionnaire which included questions on age, smoking, drinking, years of working, work-related symptoms and past medical history. The serum CO-Hb level was measured by using carboxyoximeter. Pulmonary function test was done by using automated spirometer. Additional tests, such as elecrocardiogram, urinalysis, chest radiography, blood chemistry, and CBC, were also done. Results : $FEV_1(%)$ was $97.1{\pm}0.85%$, and $105.7{\pm}1.21%$(p<0.05). FVC(%) was $94.6{\pm}0.67%$, and $102.1{\pm}1.09%$, respectively(p<0.05). Serum CO-Hb level was $2.4{\pm}0.06%$, and $1.8{\pm}0.08%$(p<0.05). After correction of confounding factors (age, smoking), significant variables were FVC(%), $FEV_1(%)$ and serum CO-Hb level(%)(p<0.05). Conclusion : Long exposure to air pollution may influence the pulmonary function and serum CO-Hb level. But, further prospective cohort study will be needed to elucidate detailed influences of specific pollutants on pulmonary function and serum carboxyhemoglobin level.

The Toxicological Pathologic Study of Amanita muscaria in Sprague-Dawley Rat (Amanita muscaria 경구투여 시 Sprague-Dawley Rat에서의 독성병리 연구)

  • Kim, Jin;Kim, Hyeong-Jin;Kim, So-Jung;Kim, Byeong-Soo;Kim, Sang-Ki;Park, Byung-Kwon;Park, Young-Seok;Cho, Sung-Dae;Jung, Ji-Won;Nam, Jeong-Seok;Choi, Chang-Sun;Lee, Seung-Ho;Jung, Ji-Youn
    • Journal of Life Science
    • /
    • v.19 no.8
    • /
    • pp.1152-1158
    • /
    • 2009
  • For the toxicological pathologic study of amanita muscaria, we have investigated single and repeated dose toxicity in Sprague-Dawley (SD) rats. Single dose toxicity study was identified as catalepsy, incline and tail pinch methods (control 0 mg/kg, low 3.3 mg/kg, middle 16.5 mg/kg, high 33.0 mg/kg). Repeated dose toxicity study was carried out in blood tests, serum tests and histopathological methods. Neurotoxicity - muscle paralysis, and convulsion and loss of movement - was observed at 33.0 mg/kg group in the single dose toxicity study. Dysfunction of liver and kidney were shown in the repeated oral administration of the amanita muscaria at 3${\sim}$4 weeks. Serum chemistry results revealed a marked increase of LDH [Lactate Dehydrogenase (3181.5 IU/L; normal 230-460 IU/l)], ALT [Alanine transaminase (124.0 IU/l; normal <40 IU/l)] but the kidney was normal. Histopathological results show interstitial edema and tubular epithelial necrosis in the kidney. These results suggest that amanita muscaria has a neurotoxic effect and causes dysfunction of liver and kidney in the SD rat.

Analysis of Lymphocyte Subsets in Peripheral Blood after Radiotherapy (악성 종양 환자에서 방사선 치료 전, 후의 림프구 아형 분석)

  • Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyun-Sik;Hur, Won-Joo;Kim, Jung-Man
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.229-236
    • /
    • 1996
  • Purpose : To evaluate the changes of differential counts and lymphocyte subsets in cancer patients' leukocyte before and after radiotherapy. Materials and Methods : From Dec. 1994 to Mar 1995, the changes of leukocyte and its subsets in 16 patients who received radiotherapy in the Dept. of Radiation Oncology of Dong-A University Hospital were investigated. Radiation was delivered from 2700 cGy to 6660 cGy with median dose of 5400 cGy. The results of pre- and Post-radiotherapy were analyzed by paired T-test. The results of patients Who received < 50 Gy and $\geq$ 50 Gy were analyzed by Wilcoxon test. Results : Before and after radiotherapy, there was not any significant differences in the counts of leukocyte, granulocyte and monocyte. A remarkable decrease was noted in lymphocyte counts after radiotherapy(p=0.015). T cells, B cells and natural killer cells were also decreased in number after radiotherapy but it was not significant statistically. 1 helper cells and T suppressor cells were also decreased in number(p>0.05). The ratio of T helper/suppressor cell was decreased from 1.52 to 1, 11 and it was significant statistically(p=0.016). The portion of T suppressor cell among all T cells was increased after radiotherapy (p=0.0195). No significant difference was observed in the analysis of leukocyte and its subsets between patients who received < 50 Gy and $\geq$ 50 Gy, Conclusion : Radiotherapy caused remarkable decrease in lymphocyte count and its subsets. Among all lymphocyte subsets, T helper cell might be the most vulnerable to radiation, considering decreased ratio of T helper/suppressor cell count after radiotherapy.

  • PDF

Effect of Hog Millet Supplementation on Hepatic Steatosis and Insulin Resistance in Mice Fed a High-fat Diet (고지방식이로 유도한 지방간 마우스에서 기장 첨가식이가 지방간 및 인슐린 저항성에 미치는 영향)

  • Park, Mi-Young;Jang, Hwan-Hee;Lee, Jin-Young;Lee, Young-Min;Kim, Jae-Hyun;Park, Jae-Hak;Park, Dong-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.4
    • /
    • pp.501-509
    • /
    • 2012
  • The dietary intake of whole grains is known to reduce the incidence of chronic diseases such as obesity, diabetes, cardiovascular disease, and cancer. In our previous study, hog millet (HM, $Panicum$ $miliaceum$ L.) water extract showed the highest anti-lipogenic activity among nine cereal types in 3T3-L1 cells. In this study, the effect of hog millet water extract on hepatic steatosis and lipid metabolism in mice fed a high fat diet was investigated. Mice were fed a normal-fat diet (ND), high-fat diet (HFD) or HFD containing 1% or 2% (w/w) HM for 7 weeks. Body weight and food intake were monitored during the study period. Insulin resistance by homeostasis model assessment (HOMA-IR), fasting lipid profile, hepatic fatty acid metabolism-related gene expression determined, and intraperitoneal glucose tolerance test (IGTT) were performed at the study's end. The results indicated that 1% and 2% HM diets effectively decreased liver weights, blood TG and T-cholesterol levels (p<0.05), while the HDL-cholesterol level was increased (p<0.05) compared to HFD-induced steatotsis mice. Hepatic lipogenic-related gene ($PPAR{\alpha}$, L-FABP, and SCD1) expressions decreased, whereas lipolysis- related gene (CPT1) expression increased in animals fed the 2% PME diet (p<0.05). In addition, mice fed 1% or 2% HM diet had markedly decreased IGTT and HOMA-IR, compared to the those of the HFD-induced hepatic steatosis control group (p<0.05). These results indicated that HM inhibited hepatic lipid accumulation by regulating fatty acid metabolism, and suggested that HM is useful in the chemoprevention or treatment of high fat-induced hepatic steatosis and hepatic steatosis-related disorders including hyperlipidemia, glucose sensitivity, and insulin resistance.

Immediate Effect of Cigarette Smoking on Exercise (흡연이 운동에 미치는 단기 효과)

  • Choe, Kang-Hyeon;Choi, Cheol-Jun;Kim, Yong-Tae;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.6
    • /
    • pp.511-516
    • /
    • 1992
  • Background: It is well known that cigarette smoking is the risk factor of lung cancer, chronic obstructive pulmonary disease and ischemic heart disease. But there are few reports about the immediate effect of cigarette smoking on the cardiopulmonary functions. The serum level of carbon monoxide increases during cigarette smoking. It is known that carbon monoxide increases respration rate, heart rate and cardiac output, with decrease in maximal oxygen consumption. So we have studied to determine the immediate effects of cigarette smoking on the cardiopulmonary function during exercise. Method: Thirteen healthy smoking male subjects were included in this study. Each subject was undertaken pulmonary function test and incremental exercise test on two separate days, one without smoking (control) and the other after smoking three cigarettes per hour for five hours. The order of the two tests was randomized. Results: 1) The mean age of the subjects was $25{\pm}4.9$ year-old and the mean smoking history was $6{\pm}5$ pack years. 2) The mean blood level of carbon monoxide on the smoking day was higher than that on the nonsmoking day ($5.97{\pm}1.34%$ vs. $1.45{\pm}0.83%$; p<0.01). 3) The mean maximal oxygen consumption on the smoking day was lower than that on the nonsmoking day ($2.09{\pm}0.32$ L/min vs. $2.39{\pm}0.32$ L/min; p<0.05). 4) The mean anaerobic threshold on the smoking day was lower than that on the nonsmoking day ($1.33{\pm}0.24$ L/min vs. $1.53{\pm}0.20$ L/min; p<0.05). 5) The mean heart rate at rest on the smoking day was higher than that on nonsmoking day ($84.38{\pm}11.06$ beats/min vs. $75.46{\pm}5.83$ beats/min; p<0.05). But the means of maximal heart rate on both days were not different. 6) The pulmonary function tests were similar on both days. Conclusion: There was no change in pulmonary function test, but the maximal oxygen consumption and anaerobic threshold were decreased on the smoking day. So it was concluded that cigarette smoking impaired the cardiovascular functions immediately during exercise.

  • PDF

The Comparative Understanding between Red Ginseng and White Ginsengs, Processed Ginsengs (Panax ginseng C. A. Meyer) (홍삼과 백삼의 비교 고찰)

  • Nam, Ki-Yeul
    • Journal of Ginseng Research
    • /
    • v.29 no.1
    • /
    • pp.1-18
    • /
    • 2005
  • Ginseng Radix, the root of Panax ginseng C. A. Meyer has been used in Eastern Asia for 2000 years as a tonic and restorative, promoting health and longevity. Two varieties are commercially available: white ginseng(Ginseng Radix Alba) is produced by air-drying the root, while red ginseng(Ginseng Radix Rubra) is produced by steaming the root followed by drying. These two varieties of different processing have somewhat differences by heat processing between them. During the heat processing for preparing red ginseng, it has been found to exhibit inactivation of catabolic enzymes, thereby preventing deterioration of ginseng quality and the increased antioxidant-like substances which inhibit lipid peroxide formation, and also good gastro-intestinal absorption by gelatinization of starch. Moreover, studies of changes in ginsenosides composition due to different processing of ginseng roots have been undertaken. The results obtained showed that red ginseng differ from white ginseng due to the lack of acidic malonyl-ginsenosides. The heating procedure in red ginseng was proved to degrade the thermally unstable malonyl-ginsenoside into corresponding netural ginsenosides. Also the steaming process of red ginseng causes degradation or transformation of neutral ginsenosides. Ginsenosides $Rh_2,\;Rh_4,\;Rs_3,\;Rs_4\;and\;Rg_5$, found only in red ginseng, have been known to be hydrolyzed products derived from original saponin by heat processing, responsible for inhibitory effects on the growth of cancer cells through the induction of apoptosis. 20(S)-ginsenoside $Rg_3$ was also formed in red ginseng and was shown to exhibit vasorelaxation properties, antimetastatic activities, and anti-platelet aggregation activity. Recently, steamed red ginseng at high temperature was shown to provide enhance the yield of ginsenosides $Rg_3\;and\;Rg_5$ characteristic of red ginseng Additionally, one of non-saponin constituents, panaxytriol, was found to be structually transformed from polyacetylenic alcohol(panaxydol) showing cytotoxicity during the preparation of red ginseng and also maltol, antioxidant maillard product, from maltose and arginyl-fructosyl-glucose, amino acid derivative, from arginine and maltose. In regard to the in vitro and in vivo comparative biological activities, red ginseng was reported to show more potent activities on the antioxidant effect, anticarcinogenic effect and ameliorative effect on blood circulation than those of white ginseng. In oriental medicine, the ability of red ginseng to supplement the vacancy(허) was known to be relatively stronger than that of white ginseng, but very few are known on its comparative clinical studies. Further investigation on the preclinical and clinical experiments are needed to show the differences of indications and efficacies between red and white ginsengs on the basis of oriental medicines.

Application of spatiotemporal transformer model to improve prediction performance of particulate matter concentration (미세먼지 예측 성능 개선을 위한 시공간 트랜스포머 모델의 적용)

  • Kim, Youngkwang;Kim, Bokju;Ahn, SungMahn
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.1
    • /
    • pp.329-352
    • /
    • 2022
  • It is reported that particulate matter(PM) penetrates the lungs and blood vessels and causes various heart diseases and respiratory diseases such as lung cancer. The subway is a means of transportation used by an average of 10 million people a day, and although it is important to create a clean and comfortable environment, the level of particulate matter pollution is shown to be high. It is because the subways run through an underground tunnel and the particulate matter trapped in the tunnel moves to the underground station due to the train wind. The Ministry of Environment and the Seoul Metropolitan Government are making various efforts to reduce PM concentration by establishing measures to improve air quality at underground stations. The smart air quality management system is a system that manages air quality in advance by collecting air quality data, analyzing and predicting the PM concentration. The prediction model of the PM concentration is an important component of this system. Various studies on time series data prediction are being conducted, but in relation to the PM prediction in subway stations, it is limited to statistical or recurrent neural network-based deep learning model researches. Therefore, in this study, we propose four transformer-based models including spatiotemporal transformers. As a result of performing PM concentration prediction experiments in the waiting rooms of subway stations in Seoul, it was confirmed that the performance of the transformer-based models was superior to that of the existing ARIMA, LSTM, and Seq2Seq models. Among the transformer-based models, the performance of the spatiotemporal transformers was the best. The smart air quality management system operated through data-based prediction becomes more effective and energy efficient as the accuracy of PM prediction improves. The results of this study are expected to contribute to the efficient operation of the smart air quality management system.

Metabolic risk and nutritional state according to breakfast energy level of Korean adults: Using the 2007~2009 Korea National Health and Nutrition Examination Survey (한국 성인의 아침식사 에너지 수준에 따른 대사적 위험과 영양상태: 2007~2009년 국민건강영양조사 자료 이용)

  • Jang, So-Hyoun;Suh, Yoon Suk;Chung, Young-Jin
    • Journal of Nutrition and Health
    • /
    • v.48 no.1
    • /
    • pp.46-57
    • /
    • 2015
  • Purpose: The aim of this study was to determine an appropriate energy level of breakfast with less risk of chronic disease for Korean adults. Methods: Using data from the 2007~2009 Korean National Health & Nutrition Examination Survey, from a total of 12,238 adults aged 19~64, the final 7,769 subjects were analyzed except subjects who were undergoing treatment for cancer or metabolic disorder. According to the percent of breakfast energy intake versus their estimated energy requirement (EER), the subjects were divided into four groups: < 10% (very low, VL), 10~20% (low, L), 20~30% (moderate, M), ${\geq}30%$ (sufficient, S). All data were analyzed on the metabolic risk and nutritional state after application of weighted value and adjustment of sex, age, residential area, income, education, job or jobless, and energy intake using a general linear model or logistic regression. Results: The subjects of group S were 16.9% of total subjects, group M 39.2%, group L 37.6%, and group VL 6.3%. The VL group included more male subjects, younger-aged (19 to 40 years), urban residents, higher income, higher education, and fewer breakfasts eaters together with family members. Among the 4 groups, the VL group showed the highest waist circumference, while the S group showed the lowest waist circumference, body mass index, and serum total cholesterol. The groups of VL and L with lower intake of breakfast energy showed high percent of energy from protein and fat, and low percent of energy from carbohydrate. With the increase of breakfast energy level, intake of energy, most nutrients and food groups increased, and the percentage of subjects consuming nutrients below EAR decreased. The VL group showed relatively higher intake of snacks, sugar, meat and eggs, oil, and seasonings, and the lowest intake of vegetable. Risk of obesity by waist circumference was highest in the VL group by 1.90 times of the S group and the same trend was shown in obesity by BMI. Risk of dyslipidemia by serum total cholesterol was 1.84 times higher in the VL group compared to the S group. Risk of diabetes by Glu-FBS (fasting blood sugar) was 1.57 times higher in the VL group compared to the S group. Conclusion: The results indicate that higher breakfast energy level is positively related to lower metabolic risk and more desirable nutritional state in Korean adults. Therefore, breakfast energy intake more than 30% of their own EER would be highly recommended for Korean adults.

Clinical Characteristics and Adherence of Patients Who Were Prescribed Home Oxygen Therapy Due to Chronic Respiratory Failure in One University Hospital: Survey after National Health Insurance Coverage (한 대학병원에서 조사된 재택산소요법을 받고 있는 환자의 특성과 재택산소요법 처방에 대한 순응도: 건강보험급여전환 후 조사)

  • Koo, Ho-Seok;Song, Young Jin;Lee, Seung Heon;Lee, Young Min;Kim, Hyun Gook;Park, I-Nae;Jung, Hoon;Choi, Sang Bong;Lee, Sung-Soon;Hur, Jin-Won;Lee, Hyuk Pyo;Yum, Ho-Kee;Choi, Soo Jeon;Lee, Hyun-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.192-197
    • /
    • 2009
  • Background: Despite the benefits of home oxygen therapy in patients suffering chronic respiratory failure, previous reports in Korea revealed lower compliance to oxygen therapy and a shorter time for oxygen use than expected. However, these papers were published before oxygen therapy was covered by the national insurance system. Therefore, this study examined whether there were some changes in compliance, using time and other clinical features of home oxygen therapy after insurance coverage. Methods: This study reviewed the medical records of patients prescribed home oxygen therapy in our hospital from November 1, 2006 to September 31, 2008. The patients were interviewed either in person or by telephone to obtain information related to oxygen therapy. Results: During study period, a total 105 patients started home oxygen therapy. The mean age was 69 and 60 (57%) were male. The mean oxygen partial pressure in the arterial blood was 54.5 mmHg and oxygen saturation was 86.3%. Primary diseases that caused hypoxemia were COPD (n=64), lung cancer (n=14), Tb destroyed lung (n=12) and others. After oxygen therapy, more than 50% of patients experienced relief of their subjective dyspnea. The mean daily use of oxygen was 9.8${\pm}$7.3 hours and oxygen was not used during activity outside of their home (mean time, 5.4${\pm}$3.7 hours). Twenty four patients (36%) stopped using oxygen voluntarily 7${\pm}$4.7 months after being prescribed oxygen and showed a less severe pulmonary and right heart function. The causes of stopping were subjective symptom relief (n=11), inconvenience (n=6) and others (7). Conclusion: The prescription of home oxygen has increased since national insurance started to cover home oxygen therapy. However, the mean time for using oxygen is still shorter than expected. During activity of outside their home, patients could not use oxygen due to the absence of portable oxygen. Overall, continuous education to change the misunderstandings about oxygen therapy, more economic support from national insurance and coverage for portable oxygen are needed to extend the oxygen use time and maintain oxygen usage.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF