• Title/Summary/Keyword: Blood Simple

Search Result 507, Processing Time 0.029 seconds

Numerical Simulation of Blood Cell Motion in a Simple Shear Flow

  • Choi, Choeng-Ryul;Kim, Chang-Nyung;Hong, Tae-Hyub
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1487-1491
    • /
    • 2008
  • Detailed knowledge on the motion of blood cells flowing in micro-channels under simple shear flow and the influence of blood flow is essential to provide a better understanding on the blood rheological properties and blood cell aggregation. The microscopic behavior of red blood cell (RBCs) is numerically investigated using a fluid-structure interaction (FSI) method based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (smoothing and remeshing) in FLUENT (ANSYS Inc., USA). The employed FSI method could be applied to the motions and deformations of a single blood cell and multiple blood cells, and the primary thrombogenesis caused by platelet aggregation. It is expected that, combined with a sophisticated large-scale computational technique, the simulation method will be useful for understanding the overall properties of blood flow from blood cellular level (microscopic) to the resulting rheological properties of blood as a mass (macroscopic).

  • PDF

A Method to Estimate Peripheral Systolic Blood Pressure using Pulse Transit Time during Bicycle Ergometer Exercise of Healthy Korean Subjects in their Twenties

  • Lee Jeong-Chan;Eo Yun-Hye;Park Kyung-Mo;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.89-93
    • /
    • 2006
  • A simple algorithm that can be used to estimate a healthy person's blood pressure using pulse transit time is proposed in this paper. Fifty healthy students participated in the experiment that was conducted in line with the study. The subjects were asked to exercise on several exercise levels using a bicycle ergometer. Their blood pressures during the succeeding rest period were measured. A simple method was proposed to illustrate the relationship between blood pressure and pulse transit time. The systolic blood pressures as well as the heights and weights of the subjects were regarded as the proper parameters, and a second-order regression curve was produced to estimate the subjects' blood pressures. The mean error of estimation was less than 10 mmHg, which was the mean error of manual measurement. Although our estimation model is so simple, it can be used to estimate continuous blood pressure measurement for bicycle ergometer exercise. The electrocardiograms, photoplethysmograms, and blood pressures, however, could not be measured simultaneously As such, their estimation may be slightly different from the results taken from simultaneous measurements.

A novel Method for Blood Typing using Acoustic Streaming (음향적 흐름을 이용한 혈액형 분석을 위한 새로운 방법)

  • Choi, Hyunjoo;Jang, Woong Sik;Nam, Jeonghun;Lim, Chae Seung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.250-255
    • /
    • 2018
  • Accurate blood typing is the crucial factor for safe and successful blood transfusion and plays a very important role in organ transplantation and genetic information of forensic medicine. Microfluidic devices have been developed to overcome the limitations of the conventional blood typing methods. In this study, we demonstrate a Lamb wave-based device for simple blood typing in a sample droplet and we propose new indices for quantitative and accurate blood typing. Using Lamb wave-induced acoustic streaming in the droplet, the blood sample and the reagent can be mixed rapidly and red blood cells start to form clumps, which is agglutination. Based on the recorded image and video, the intensity of transmitted light through the sample droplet is evaluated to determine the blood type. Effect of the concentration of suspended red blood cells was evaluated and we found that 10% concentration of suspended red blood cells was suitable to observe the difference between aggregated and non-aggregated samples. Finally, sample with blood type A could be determined using anti-A reagent in our Lamb wave-based device. Our device enables simple and accurate blood typing, which can be applied to resource-limited environments.

Estimation of Lead Exposure Intensity by Industry Using Nationwide Exposure Databases in Korea

  • Koh, Dong-Hee;Park, Ju-Hyun;Lee, Sang-Gil;Kim, Hwan-Cheol;Jung, Hyejung;Kim, Inah;Choi, Sangjun;Park, Donguk
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.439-444
    • /
    • 2021
  • Background: In a previous study, we estimated exposure prevalence and the number of workers exposed to carcinogens by industry in Korea. The present study aimed to evaluate the optimal exposure intensity indicators of airborne lead exposure by comparing to blood lead measurements for the future development of the carcinogen exposure intensity database. Methods: Data concerning airborne lead measurements and blood lead levels were collected from nationwide occupational exposure databases, compiled between 2015 and 2016. Summary statistics, including the arithmetic mean (AM), geometric mean (GM), and 95th percentile level (X95) were calculated by industry both for airborne lead and blood lead measurements. Since many measurements were below the limits of detection (LODs), the simple replacement with half of the LOD and maximum likelihood estimation (MLE) methods were used for statistical analysis. For examining the optimal exposure indicator of airborne lead exposure, blood lead levels were used as reference data for subsequent rank correlation analyses. Results: A total of 19,637 airborne lead measurements and 32,848 blood lead measurements were used. In general, simple replacement showed a higher correlation than MLE. The results showed that AM and X95 using simple replacement could be used as optimal exposure intensity indicators, while X95 showed better correlations than AM in industries with 20 or more measurements. Conclusion: Our results showed that AM or X95 could be potential candidates for exposure intensity indicators in the Korean carcinogen exposure database. Especially, X95 is an optimal indicator where there are enough measurements to compute X95 values.

Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect (헤마토크릿 영향을 최소화한 종이 혈당센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

Bioavailability of Clonazepam in human plasma using a simple HPLC

  • Lee, Dong-Kyu;Jeong, Ji-Hoon;Park, Joon-Hong;You, Dae-Sik;Sohn, Uy-Dong
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.244.1-244.1
    • /
    • 2003
  • We aimed at determining bioavailability of clonazepam, an anxiolytic drug, and developing a simple analysis in human blood using HPLC. A rapid and sensitive HPLC method was developed and validated using reverse-phase C18 column with retension time and limit of quantification of clonazepam being 2.58 min and 5hg/ml, respectively. Quantification was performed at 235 nm with p-hydroxybenzoic acid ethyl ester as internal standard. The method involved a simple extraction. In order to study blood level profile in time, sight volunteers were enrolled and orally took 6 mg clonazepam once. (omitted)

  • PDF

Bioavailability of Procainamide HCl in human plasma using a simple HPLC

  • Park, Joon-Hong;Jeong, Ji-Hoon;Choi, Tae-Sik;Lee, Dong-Kyu;Shim, Jae-Ho;Sohn, Uy-Dong
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.240.2-240.2
    • /
    • 2003
  • We aimed at determining bioavailability of procainarnide HCl, an antiarrhythmic drug, and developing a simple analysis in human blood using HPLC. A rapid and sensitive HPLC method was developed and validated using reverse-phase C18 column with retension time and limit of quantification of procainamide HCl being 2.58 min and 50ng/ml, respectively. Quantification was performed at 275 nm with caffeine as internal standard. The method involved a simple extraction. In order to study blood level profile in time, eight volunteers were enrolled and orally took 250 mg procainamide HCl once. (omitted)

  • PDF

Dimethylnitrosamine-Induced Reduction in the Level of Poly-ADP-Ribosylation of Histone Proteins of Blood Lymphocytes - a Sensitive and Reliable Biomarker for Early Detection of Cancer

  • Kma, Lakhan;Sharan, Rajeshwar Nath
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6429-6436
    • /
    • 2014
  • Poly-ADP-ribosylation (PAR) is a post-translational modification of mainly chromosomal proteins. It is known to be strongly involved in several molecular events, including nucleosome-remodelling and carcinogenesis. In this investigation, it was attempted to evaluate PAR level as a reliable biomarker for early detection of cancer in blood lymphocyte histones. PAR of isolated histone proteins was monitored in normal and dimethylnitrosamine (DMN)-exposed mice tissues using a novel ELISA-based immuno-probe assay developed in our laboratory. An inverse relationship was found between the level of PAR and period of DMN exposure in various histone proteins of blood lymphocytes and spleen cells. With the increase in the DMN exposure period, there was reduction in the PAR level of individual histones in both cases. It was also observed that the decrease in the level of PAR of histones resulted in progressive relaxation of genomic DNA, perhaps triggering activation of genes that are involved in initiation of transformation. The observed effect of carcinogen on the PAR of blood lymphocyte histones provided us with a handy tool for monitoring biochemical or physiological status of individuals exposed to carcinogens without obtaining biopsies of cancerous tissues, which involves several medical and ethical issues. Obtaining blood from any patient and separating blood lymphocytes are routine medical practices involving virtually no medical intervention, post-procedure medical care or trauma to a patient. Moreover, the immuno-probe assay is very simple, sensitive, reliable and cost-effective. Therefore, combined with the ease of preparation of blood lymphocytes and the simplicity of the technique, immuno-probe assay of PAR has the potential to be applied for mass screening of cancer. It appears to be a promising step in the ultimate goal of making cancer detection simple, sensitive and reliable in the near future.

Factors Affecting Blood Loss During Thoracoscopic Esophagectomy for Esophageal Carcinoma

  • Urabe, Masayuki;Ohkura, Yu;Haruta, Shusuke;Ueno, Masaki;Udagawa, Harushi
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.466-472
    • /
    • 2021
  • Background: Major intraoperative hemorrhage reportedly predicts unfavorable survival outcomes following surgical resection for esophageal carcinoma (EC). However, the factors predicting the amount of blood lost during thoracoscopic esophagectomy have yet to be sufficiently studied. We sought to identify risk factors for excessive blood loss during video-assisted thoracoscopic surgery (VATS) for EC. Methods: Using simple and multiple linear regression models, we performed retrospective analyses of the associations between clinicopathological/surgical factors and estimated hemorrhagic volume in 168 consecutive patients who underwent VATS-type esophagectomy for EC. Results: The median blood loss amount was 225 mL (interquartile range, 126-380 mL). Abdominal laparotomy (p<0.001), thoracic duct resection (p=0.014), and division of the azygos arch (p<0.001) were significantly related to high volumes of blood loss. Body mass index and operative duration, as continuous variables, were also correlated positively with blood loss volume in simple linear regression. The multiple linear regression analysis identified prolonged operative duration (p<0.001), open laparotomy approach (p=0.003), azygos arch division (p=0.005), and high body mass index (p=0.014) as independent predictors of higher hemorrhage amounts during VATS esophagectomy. Conclusion: As well as body mass index, operation-related factors such as operative duration, open laparotomy, and division of the azygos arch were independently predictive of estimated blood loss during VATS esophagectomy for EC. Laparoscopic abdominal procedures and azygos arch preservation might be minimally invasive options that would potentially reduce intraoperative hemorrhage, although oncological radicality remains an important consideration.

Blood Conservation in Coronary Artery Bypass Surgery - in 24 consecutive patients - (관상동맥 우회로술 환자에서 혈액 보존법)

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1048-1054
    • /
    • 1992
  • With use of a simple, inexpensive and nonpharmacological program for blood conservation, 24 consecutive patients underwent elective or urgent coronary artery bypass grafting without need of homologous red cell transfusions and /or fresh frozen plasma transfusions in 16 patients[66.7%]. Left internal mammary artery graftings were done in 18 patients[75%], with supplemental saphenous vein grafts in all. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of ext-racorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the oxygenator, autotransfusion of the shed mediastinal blood was continued hourly by the next early;norning. The mean postoperative mediastinal blood loss was 364$\pm$234ml, whereas 553$\pm$383ml was autotransfused. 4 patients [16.7%] received homologous blood and an additional 4 patients[16.7%] fresh frozen plasma. Thus, in total, 16 patients[66.7%] were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 10.3$\pm$1.6g /dl. Postoperative complications were few and there was no hospital death.

  • PDF