• 제목/요약/키워드: Blood Characteristics

검색결과 1,961건 처리시간 0.028초

상부복외측 연수 심혈관계 세포의 체성교감반사시 자발적 흥분발사특성 분석 : I. 실험적 연구 (Spontaneous Firing Characteristics of Cardiovascular Neurons in the Rostral Ventrolateral Medulla During Somatosympathetic Reflex : II. Minimal Neuronal Model)

  • 차은종;구용숙;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.71-80
    • /
    • 1996
  • A number of experimental evidences suggest that the rnun ventrolateral medulla(RVLM) is the final common pathway in the regulation of arterial blood pressure. A Voup of neurons in the RVLM, called the cardiovascular neurons (UN), show spontaneous activity temporally synchronized with the periodic cardiac cycle. These neurons affect the sympathetic nerve discharge(SND), thus are believed to be responsible for blood pressure control. The present experiment identified 98 UVNs in 42 cats based on the temporal relationships between each neuron's activity with both the cardiac cycle and SWD. In 20 UWL changes of spontaneous firing rate(FR) during the somatosympathetic reflex(SSR) were studied Five different firing patterns were observed during the pressor and depressor responses of SSR, implying that they form an interconnected neuronal circuit interacting with one another to generate efferent signals for blood pressure regulation. In the following companion paper, the firing patterns of CVN are analyzed to develop a minimal neuronal circuit model explaining the present experimental outcome.

  • PDF

혈관계의 특성이 반영된 심혈관계 시뮬레이터의 개발 (Development of a Cardiovascular Simulator with Cardiovascular Characteristics)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제16권3호
    • /
    • pp.33-40
    • /
    • 2012
  • Objectives: Existing cardiovascular simulators are used to evaluate artificial organs such as artificial hearts, prosthetic valves, and artificial blood vessels, and pulses are typically triggered using artificial hearts. However, the forms of pulse waves vary according to the location of arteries, and for precise assessment of artificial blood vessels, the development of simulators that generate diverse pressure pulse waves is necessary. This study developed a novel cardiovascular simulator that generates different forms of pulse waves. Methods: This simulator consists of a stepping motor, a slider-crank mechanism that transforms the rotation movement of a motor into the straight-line motion of a piston, a piston that generates pulsatile flows, a water tank that supplies fluids, an elastic tube made of silicon, and a device that adjusts the terminal resistance of fluids. Results & Conclusion: This study examined motor rotation and its operation under conditions similar to the physiological conditions of the heart. The simulator developed in this study produced diverse forms of waves, and the generated pressure waves well satisfied physiological conditions.

A Vascular Characteristic Index of Blood Pressure Variation using the Pulse Wave Signal

  • Kim, Gi-Ryon;Jung, Dong-Keun;Ye, Soo-Young;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.213-219
    • /
    • 2008
  • Pulse waves continuously change with respect to the characteristics and status of the cardiovascular system and in relation to the blood pressure (BP) and the pulse wave velocity (PWV). Monitoring the vascular condition by analyzing the variations in pulse waveforms has been used to diagnose vascular disorders and in drug treatment of arteriosclerosis and peripheral circulatory obstruction. In this paper, we investigated the vascular characteristic index with regard to the BP and classified by pulse wave signals. The pressure pulse wave and photoplethysmography (PPG) were measured simultaneously while subjects exercised, producing changes in the BP, to analyze the variation in the vascular characteristic index. We investigated the correlation between the BP and vascular characteristic index with regard to the classification methods of the pulse wave. The reflection index (RI) and vascular stiffness index were correlated with the diastolic BP, but no correlation was found between these parameters and the systolic BP. These results suggest the possibility of estimating BP through simple measurements of pulse waves.

반사광을 이용한 손목시계형 혈중산소포화도 (SpO2) 측정기 (A Wearable Watch-type Reflectance-based Blood-oxygen Saturation (SpO2) Level Estimation)

  • 이후석;탑타른;이진석
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.578-579
    • /
    • 2015
  • Transmission and reflectance are two non-invasive techniques to perform pulse oximetry. This paper presents a design of reflectance-based pulse oximetry for watch-type wearable device, in which sensor and detector are located on the same surface of the body part. The basic principle of a pulse oximeter is based on the measurement of the red and infrared (IR) light absorption. Oxygenated blood has significant differences of light absorption characteristics than deoxygenated blood under red (660 nm) and infrared (940 nm) wavelength. Infrared is absorbed more by oxygenated hemoglobin than red. So the hardware implementation is included placing of the two LEDs (red and IR) with single photo-detector in the middle on the patient's wrist to get the corresponding pulsatile signals which are used to estimate the $SpO_2$.

Effects of multi-enzyme supplementation in a corn and soybean meal-based diet on growth performance, apparent digestibility, blood characteristics, fecal microbes and noxious gas emission in growing pigs

  • Yin, Jia;Kim, In-Ho
    • 농업과학연구
    • /
    • 제46권1호
    • /
    • pp.1-10
    • /
    • 2019
  • The objective of this study was to determine the effect of multi-enzyme supplementation in a corn and soybean meal-based diet on the growth performance, apparent nutrient digestibility, blood profile, fecal microbes and noxious gas emission in growing pigs. A total of 80 crossbred [(Landrace ${\times}$ Yorkshire) ${\times}$ Duroc] growing pigs with an average body weight (BW) of $25.04{\pm}1.44kg$ were used in a 6-week experiment. The experimental treatments were as follows: CON, basal diet and; T1, basal diet + 100 mg/kg multi-enzyme. During the experiment, the pigs fed the diet with multi-enzyme supplementation had a higher gain to feed ratio (G/F) (p < 0.05) than the pigs fed the diet without multi-enzyme supplementation. On day 42, the pigs fed the diet with multi-enzyme supplementation had decreased $H_2S$ and $NH_3$ emissions (p < 0.05) than the pigs fed the diet without multi-enzyme supplementation. However, no effect was observed on nutrient digestibility, blood profiles and fecal microbes among the treatments (p > 0.05). In conclusion, it is suggested that multi-enzyme supplementation in a corn and soybean meal based diet can partly improve the growth performance and noxious gas emission of growing pigs.

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • 제65권2호
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

Structural Characteristics and Properties of Silk Fibroin/Polyurethane Blend Films

  • Um, In-Chul;Kweon, Hae-Yong;Chang mo Hwang;Min, Byung-Goo;Park, Young-Hwan
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제5권2호
    • /
    • pp.163-170
    • /
    • 2002
  • In this paper, silk fibroin (SF)/polyurethane (PU) blend films were fabricated to develop a new biomaterial for biomedical applications. These blend films were prepared using formic acid as a cosolvent, and structural characteristics and properties of blend films were investigated. FTIR results suggested that there was no specific interaction between SF and PU, implying molecular immiscibility in SF/PU blend films. Furthermore, it was revealed by XRD method that the crystalline region of blend components was not perturbed by counterpart polymers. The degree of phase separation of SF/PU blend films was diminished by increasing PU content in blend. Especially, the blend with 70% content of PU showed no evidence of macro-phase separation in SEM observation. However, SF/PU blend (70/30) was revealed to be phase-separated in a lower dimension confirmed by DMTA measurement. TGA result showed that thermal decomposition temperature of blend film was slightly decreased compared to those of SF and PU polymer itself, Though mechanical properties of SF/PU blend films were not good enough due to the solvent, blood compatibility of PU can be enhanced markedly by mixing with SF for SF/PU blend film.

DNA Marker를 이용한 한국 재래닭의 유전특성 분석 (Analysis of Genetic Characteristics of Korean Native Chicken Using DNA Marker)

  • 이학교;이성진;황규춘;정일정;박용호;손시환;신영수;오봉국;한재용
    • 한국가금학회지
    • /
    • 제23권4호
    • /
    • pp.177-183
    • /
    • 1996
  • This study was conducted to analyze genetic characteristics of Korean Native Chicken three lines classified on the basis of the feather color and appearance (Red, Yellow, and Black) using DNA fingerprinting method. To estimate the genetic relatedness among breeds and similarities within breeds, we collected blood samples from Korean Native Chicken (KNC), Rhode Island Red (RIR), White Leghorn (WL), and Cornish(CN) and obtained genomic DNA from the blood of 10 individuals randomly selected within the breeds and lines. The genomic DNA samples were digested with restriction enzymes (Hinf J, Hae Ill) and hybridized with various probes (Jeffreys' probes 33.15, 33.6 and M13) after Southern transfer. Genetic similarities within breeds were characterized by band sharing (BS) value, estimated by the DFP band pattern between the pair of lanes. BS values within WL, RIR, and KNC were 0.82, 0.70 and 0.56, respectively. Relative genetic diversity (BS value) of KNC was higher than those two breeds (WL, RIR). Estimation of genetic similarity between KNC lines and control breed (RIR) was 0.32, whereas similarity within KNC lines (6 groups) was 0.50. In this analysis, KNC was showed to have a highly genetic diver-sity at the DNA level, and to be closer in genetic distance to RIR (0.67) than any other breeds.

  • PDF

압축코팅법에 의한 3단계 약물방출형 지속성제제의 제조 및 용출특성 (Preparation and Dissolution Characteristics of the Compression-Coated Controlled Release Tablet Exhibiting Three-step Release)

  • 김철수;권혁노;차봉진;권종원;양중익;민신홍
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권2호
    • /
    • pp.133-137
    • /
    • 1992
  • A novel oral controlled release tablet which may offer more uniform drug level in the body than simple zero-order was developed. The tablet is composed of three layers; outer film layer, middle part compression-coated hydroxypropylmethylcellulose (HPMC) matrix layer, and inner core layer. Each layer contains nicardipine HCl as a model drug. In vitro dissolution test showed that the tablet released the drug in clear three steps; a rapid initial release, followed by a constant rate of release, and then a second phase of fast release of drug. The dissolution characteristics could be modified easily by changing the grade of HPMC, thickness of matrix layer, content of methylcellulose in matrix layer, content of active ingredient in each layer. The pH of dissolution medium did not affect the release profile. This three-step release system is expected to raise the blood concentration rapidly to effective level and to maintain effective blood level longer than simple slow-release systems.

  • PDF

성인 비만과 비교를 통한 소아 비만의 특성 연구 - 천안 지역 중심으로 (A Study on Characteristics of Obesity in Young Age and Comparison of Obesity in Adults in Cheon-an)

  • 서희연;한재경;김윤희
    • 대한한방소아과학회지
    • /
    • 제24권2호
    • /
    • pp.31-39
    • /
    • 2010
  • Objectives The recent prevalence rate of obesity in children is increasing, but so far the majority of ongoing research is focused on obesity in adults. Even comparison studies between obesity in adults and in children are insufficient at this stage. Thus, our research will investigate the characteristics of obesity in children based on the comparison with adults. Methods The blood levels including glucose, cholesterol, AST, ALT of obese children and obese adults were compared and analyzed. Results From comparison studies, the levels of glucose, cholesterol, ALT in adults were higher than in children. In order to take account the age differences, only the rate of abnormal levels based on the reference range were compared. As a result, the abnormal rate in blood cholesterol level was higher in children. Conclusions Childhood obesity may develop complications at early age and has high potential risk to result in adult obesity as well. Therefore, child obesity needs to be treated with more caution and careful attention.