• Title/Summary/Keyword: Block variance

Search Result 143, Processing Time 0.027 seconds

Mitral Valve Replacement -Report of Five Cases- (승모판막 이식수술 -5예 보고-)

  • 송요준
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.189-200
    • /
    • 1974
  • The mitral valve replacement with Beall prosthetic valve was performed on three patients, and double valve replacement. aortic and mitral valve, was performed in this department.1) The preoperative studies about the first case were compatible with mitral steno-insufficency.The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary hypass using hypothermic hemodilution technique. The total perfusion time was eighty minutes. Immediate postoperative course was smooth, but this patient was died of asphyxia due to tracheomalacia complicated after tracheostomy 3 months after operation. Autopsy on this patient revealed that no thrombus and no ball variance could be found, and endothelization on the valve cuff was satisfactory. 2) The preoperative studies on the second case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary bypass using hypothermic hemodilution technigue. The total perfusion time was 123 minutes. This patient was discharged in good condition and follow-up study after 16 months revealed the patient had enjoyed healthy life. 3) The preoperative studies about the third case were compatible with aortic insufficiency and mitral stenoinsufficiency. The diseased valves were replaced with type 2 sutureless Magovern aortic valve and the medium sized Beall mitral prosthesis under cardiopulmonary bypass using hypothermic hemodilution technIque and coronary artery perfusion. The total perfusion time was 155 minutes. This patient was discharged in good condition, but thromboembolism was developed 2 months after discharge. 4) The preoperative studies about the fourth case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve. The total perfusion time was 132 minutes. The atrioventricular block developed just after operation but converted to normal sinus rhythmn on the third postperative day. The preoperative NYHA functional classification IV was converted to Class 1 or 11 at the time of discharge and this patient enjoyed healthy life. Attendum; The fifth case, nineteen years old male with mital insufficiency underwent Beall valve replacement and his course was uneventful 2 weeks after operation.

  • PDF

A Study on the heat generation during implant abutment preparation (임플란트 지대주 삭제시의 발생열에 관한 연구)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Jang, Tae-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Evaluation of Mungbean Genotypes Based on Yield Stability and Reaction to Mungbean Yellow Mosaic Virus Disease

  • Alam, A.K.M. Mahbubul;Somta, Prakit;Jompuk, Choosak;Chatwachirawong, Prasert;Srinives, Peerasak
    • The Plant Pathology Journal
    • /
    • v.30 no.3
    • /
    • pp.261-268
    • /
    • 2014
  • This work was conducted to identify mungbean genotypes showing yield stability and resistance to mungbean yellow mosaic virus (MYMV) disease. Sixteen genotypes were evaluated in a randomized complete block design with two replications for two years (2011 and 2012) at three locations (Gazipur, Ishurdi and Madaripur) of the Bangladesh Agricultural Research Institute. An analysis of variance exhibited significant effects of genotype (G), environment (E), and genotype ${\times}$ environment ($G{\times}E$) on grain yield. Among eight agronomic characters, the principal component 1 (PC1) was always higher than the PC2. Considering $G{\times}E$ interaction, BM6 was the best genotype at all three locations in both years. Based on grain yield and stability performance, BM6 ranked first while the worst performing genotypes were BM1 and G10. Based on discrimination and representation, Gazipur was identified as an ideal environment for these mungbeans. Relationship between soil-plant analysis developments (SPAD) value was positive with yield but negative with MYMV severity. BM6, G1 and G2 were considered as promising sources of resistance for low disease score and stable response across the environments. The environment proved to have an influence on MYMV infection under natural infestation. A positive correlation was observed between disease score and the temperature under natural growing condition.

Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer study

  • Amid, Reza;Kadkhodazadeh, Mahdi;Fekrazad, Reza;Hajizadeh, Farzin;Ghafoori, Arash
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: The present study aimed to measure root surface roughness in teeth with periodontitis by a profilometer following root planning with ultrasonic and hand instruments with and without erbium-doped yttrium aluminium garnet (Er:YAG) laser irradiation. Methods: Sixty single-rooted maxillary and mandibular teeth, extracted because of periodontal disease, were collected. The crowns and apices of the roots were cut off using a diamond bur and water coolant. The specimens were mounted in an acrylic resin block such that a plain root surface was accessible. After primary evaluation and setting a baseline, the samples were divided into 4 groups. In group 1, the samples were root planned using a manual curette. The group 2 samples were prepared with an ultrasonic scaler. In group 3, after scaling with hand instrumentation, the roots were treated with a Smart 1240D plus Er:YAG laser and in group 4, the roots were prepared with ultrasonic scaler and subsequently treated with an Er:YAG laser. Root surface roughness was then measured by a profilometer (MahrSurf M300+RD18C system) under controlled laboratory conditions at a temperature of $25^{\circ}C$ and 41% humidity. The data were analyzed statistically using analysis of variance and a t-test (P<0.05). Results: Significant differences were detected in terms of surface roughness and surface distortion before and after treatment. The average reduction of the surface roughness after treatment in groups 1, 2, 3, and 4 was 1.89, 1.88, 1.40, and 1.52, respectively. These findings revealed no significant differences among the four groups. Conclusions: An Er:YAG laser as an adjunct to traditional scaling and root planning reduces root surface roughness. However, the surface ultrastructure is more irregular than when using conventional methods.

Studies on the properties of electrochromic films and the effect of migration barrier (Electrochromic 막의 특성과 물질이동 방지막의 효과에 대한 연구)

  • 황하룡;백지흠;허증수;이덕동;임정옥;장동식
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • After manufacturing the electrochromic device (structure: ITO glass/$WO_3$/electrolyte/$V_2O_5$/ITO;glass) by using of sol-gel process and evaporation, optical properties and migration effect were investigated. The result shows that electrochromic device with heat treated (at water vapor ambient, $500^{\circ}C$, 1 hour) sol-gel coated $WO_3$ and $V_2O_5$ films had the highest transmittance variance. Electrochromic devices are based on the reversible insertion of guest atoms into structure of the host solid. But after cyclic operation, we find that the tungsten in $WO_3$ film and the indium in ITO film were migrated with each other. For the purpose of blocking migration, tungsten barrier film is inserted between ITO and $WO_3$ film. The result of cyclic voltamogram and the Auger depth profile show that the peak separation of cyclic voltamogram is reduced to below 1/10 and we could effectively block the indium and tungsten migration that is caused by flow of Li ions.

  • PDF

Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing

  • Seong-keun, Yoo;Ye-Hyeon, Jo;In-Sung Luke, Yeo;Hyung-In, Yoon;Jae-Hyun, Lee;Jin-Soo, Ahn;Jung-Suk, Han
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.335-345
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence.

Dentinal tubule penetration of sodium hypochlorite in root canals with and without mechanical preparation and different irrigant activation methods

  • Renata Aqel de Oliveira;Theodoro Weissheimer;Gabriel Barcelos So ;Ricardo Abreu da Rosa ;Matheus Albino Souza;Rodrigo Goncalves Ribeiro ;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.1.1-1.11
    • /
    • 2023
  • Objectives: This study evaluated the dentinal penetration depth of 2.5% sodium hypochlorite (NaOCl) in root canals with and without preparation and different irrigant activation protocols. Materials and Methods: Sixty-three bovine mandibular incisors were randomly allocated to 6 groups (n = 10): G1, preparation + conventional needle irrigation (CNI); G2, preparation + passive ultrasonic irrigation (PUI); G3, preparation + Odous Clean (OC); G4, no preparation + CNI; G5, no preparation + PUI; G6, no preparation + OC; and CG (negative control; n = 3). Samples were filled with crystal violet for 72 hours. Irrigant activation was performed. Samples were sectioned perpendicularly along the long axis, 3 mm and 7 mm from the apex. Images of the root thirds of each block were captured with a stereomicroscope and analyzed with an image analysis software. One-way analysis of variance, followed by the Tukey post hoc test, and the Student's t-test were used for data analysis, with a significance level of 5%. Results: The NaOCl penetration depth was similar when preparation was performed, regardless of the method of irrigation activation (p > 0.05). In the groups without preparation, G6 showed greater NaOCl penetration depth (p < 0.05). The groups without preparation had a greater NaOCl penetration depth than those with preparation (p = 0.0019). Conclusions: The NaOCl penetration depth was similar in groups with root canal preparation. Without root canal preparation, OC allowed deeper NaOCl penetration. The groups without preparation had greater NaOCl penetration than those undergoing root canal preparation.

Biological Activities of Calcium Polyphosphate (Calcium polyphosphate의 생물학적 활성도에 관한 연구)

  • Seol, Yang-Jo;Lee, Jae-Il;Lee, Yong-Moo;Lim, Yoon-Tak;Kim, Seok-Young;Ku, Young;Rhyu, In-Chul;Hahm, Byung-Do;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.213-231
    • /
    • 2000
  • 이 연구의 목적은 다공성의 CPP 내부에 쥐의 장골의 골수에서 유래된 세포를 접종하고 3차 원적으로 배양하여 CPP가 골 형성을 위한 조직공학의 지지체로 적용가능한가를 연구하는 것과 Calcium PolyPhosphate(CPP)의 돌연변이 유발성을 검사하는 것이다. 무수 ($Ca(H_2PO_4)$)를 condensation하여 무결정의 ($Ca(PO_3)$)를 얻고 이를 용융하고 냉각시킨 후 분쇄하여 Calcium polyphosphate(CPP) powder를 얻었다. 다공성의 CPP는 5% $SiO_2$를 첨가하여 sponge 형태로 $450-550{\mu}m$ 소공의 크기를 가지는 것과(CPP-45ppi) $200-300{\mu}m$의 소공의 크기를 가지는 것(CCP-60ppi) 2가지로 제작하였다. 각각의 CPP matrices는 $5mm{\times}5mm{\times}1mm$의 블록 형태로 만들었다. 체중 100g 내외의 백서에서 장골(femur, tibia)을 채취하여 백서의 장골 골수 세포를 분리하여 배양한 후 24well에 CPP block을 넣고 CPP block 당 $10^5$개의 배양한 세포를 접종하였다. 배양 1, 7, 14, 및 21 일째에 각 well에서 trypsin EDTA를 이용하여 2회 반복하여 cell을 분리하였고, 원심분리한 후 hemacytometer로 측정하였다. 또, 45ppi와 60ppi, 그 리 고 Tissue Culture Polystyrene(control group)에 접종, 배양된 세포들의 염기성 인산분해효소활성도를 배양 7, 14, 및 21 일째에 각각 측정하였다. 각 기간별로 배양된 세포-CPP 혼합체내에서 세포의 부착 및 증식과 형성된 조직의 3차원적 형태를 관찰하기 위하여 주사전자현미경하에서의 관찰하였다. CPP의 돌연변이 유발성 검사 (mutagenicity test)를 위해 hypoxanthine-guanine phosphoribosyl transferase(HPRT) assay를 하였다. NIH3T3 cell line과 CHO-K1 cell line으로 각각 $1000{\mu}g/m{\ell}$, $100{\mu}g/m{\ell}$, $10{\mu}g/m{\ell}$ 그리고 $1{\mu}g/m{\ell}$의 CPP 농도에서 측정하였다. 통계적 분석을 위해서 모든 측정은 각군당 4개체 이상 시험하였고, 각 측정값은 평균값${\pm}$표준편차로 나타내었다. 각 군간의 통계적 유의성 검정을 위해서 Analysis of variance(ANOVA)를 이용하였고 Tukey의 방법으로 사후분석을 실시하였다. 제작된 CPP matrices 소공들이 서로간에 연결이 잘 되어있는 형태였다. 두 가지로 제조된 CPP(45ppi와 60ppi) 모두에서 세포의 부착이 잘 일어났고, 부착된 세포의 분열도 잘 일어났다. 2 가지의 CPP 모두에서 7, 14, 21일째의 세포 수는 1일째에 비해 유의성 있게 증가하였다(P<0.01). 3차원적 구조인 Calcium PolyPhosphate에서 배양한 세포는 24well dish(tissue culture polystyrene)에서 평면적으로 배양한 대조군의 세포에서 보다 염기성 인산분해효소 (Alkaline Phosphatase)를 유의성 있게 높게 나타냈다. 주사전자현미경에서 세포-CPP 혼합체를 관찰한 결과, CPP block에 세포들이 잘부착되어 있었고, 시간이 지남에 따라 세포가 여러 층을 형성하면서 뭉치는 현상을 보였다. 또, HPRT assay 결과 , Calcium PolyPhosphate는 돌연변이 유발성을 보이지 않았다. 이상의 결과로 볼 때 CPP에는 세포부착이 잘 일어나고, 지지체 상에서 세포의 분열도 활발하게 일어나므로 골조직을 위한 조직공학의 우수한 지지체가 될 수 있을 것으로 사료된다.

  • PDF

Convergence Study on the Development and Material Property of Wax for Surface Conservation of Iron Alloy Outdoor Sculpture (야외 철제 조각 작품 표면 보존용 왁스의 개발 및 재료 특성에 관한 융합 연구)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.151-160
    • /
    • 2018
  • Waxes currently used as a coating material to preserve surfaces of outdoor iron sculptures tend to face lower coating strength and efflorescence due to the aging from air pollution and acid rains. Consequently, they are subjected to repeated corrosions shortly after the treatment. And the sculptures face the problem losing their original nature because of the changes of colors and lusters, so this convergence study aims at developing wax with better performance than the existing materials. For this reason, the study identified the effects of physical property using the environmental experiments such as the tests of salt spray and gas corrosion as well as the analysis of luster level and thermo-gravimetry. As this study result, the developed ISC wax showed the excellent blocking effect from salt water and coating durability more than five times compared with the existing waxes, better acid resistance by two-four times, sun block effect by 2-10 times, improved luster variance by 3-16 times, improved thermo-stability and durability by 0.5-5 times, and therefore demonstrating far better coating effect than the existing waxes. In the light of these findings, this study contributes for this new development which can replace the existing waxes used so far in order to preserve the outdoor iron sculptures.

Robust Image Fusion Using Stationary Wavelet Transform (정상 웨이블렛 변환을 이용한 로버스트 영상 융합)

  • Kim, Hee-Hoon;Kang, Seung-Hyo;Park, Jea-Hyun;Ha, Hyun-Ho;Lim, Jin-Soo;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1181-1196
    • /
    • 2011
  • Image fusion is the process of combining information from two or more source images of a scene into a single composite image with application to many fields, such as remote sensing, computer vision, robotics, medical imaging and defense. The most common wavelet-based fusion is discrete wavelet transform fusion in which the high frequency sub-bands and low frequency sub-bands are combined on activity measures of local windows such standard deviation and mean, respectively. However, discrete wavelet transform is not translation-invariant and it often yields block artifacts in a fused image. In this paper, we propose a robust image fusion based on the stationary wavelet transform to overcome the drawback of discrete wavelet transform. We use the activity measure of interquartile range as the robust estimator of variance in high frequency sub-bands and combine the low frequency sub-band based on the interquartile range information present in the high frequency sub-bands. We evaluate our proposed method quantitatively and qualitatively for image fusion, and compare it to some existing fusion methods. Experimental results indicate that the proposed method is more effective and can provide satisfactory fusion results.