• Title/Summary/Keyword: Block bone

Search Result 235, Processing Time 0.031 seconds

"Over-inlay" block graft and differential morphometry: a novel block graft model to study bone regeneration and host-to-graft interfaces in rats

  • Ghiacci, Giulia;Graiani, Gallia;Ravanetti, Francesca;Lumetti, Simone;Manfredi, Edoardo;Galli, Carlo;Cacchioli, Antonio;Macaluso, Guido Maria;Sala, Roberto
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.220-233
    • /
    • 2016
  • Purpose: The aim of this study was to present new a model that allows the study of the bone healing process, with an emphasis on the biological behavior of different graft-to-host interfaces. A standardized "over-inlay" surgical technique combined with a differential histomorphometric analysis is presented in order to optimize the use of critical-size calvarial defects in pre-clinical testing. Methods: Critical-size defects were created into the parietal bone of 8 male Wistar rats. Deproteinized bovine bone (DBBM) blocks were inserted into the defects, so that part of the block was included within the calvarial thickness and part exceeded the calvarial height (an "over-inlay" graft). All animals were sacrificed at 1 or 3 months. Histomorphometric and immunohistochemical evaluation was carried out within distinct regions of interest (ROIs): the areas adjacent to the native bone (BA), the periosteal area (PA) and the central area (CA). Results: The animals healed without complications. Differential morphometry allowed the examination of the tissue composition within distinct regions: the BA presented consistent amounts of new bone formation (NB), which increased over time ($24.53%{\pm}1.26%$ at 1 month; $37.73%{\pm}0.39%$ at 3 months), thus suggesting that this area makes a substantial contribution toward NB. The PA was mainly composed of fibrous tissue ($71.16%{\pm}8.06%$ and $78.30%{\pm}2.67%$, respectively), while the CA showed high amounts of DBBM at both time points ($78.30%{\pm}2.67%$ and $74.68%{\pm}1.07%$, respectively), demonstrating a slow remodeling process. Blood vessels revealed a progressive migration from the interface with native bone toward the central area of the graft. Osterix-positive cells observed at 1 month within the PA suggested that the periosteum was a source of osteoprogenitor elements. Alkaline phosphatase data on matrix deposition confirmed this observation. Conclusions: The present model allowed for a standardized investigation of distinct graft-to-host interfaces both at vertically augmented and inlay-augmented sites, thus possibly limiting the number of animals required for pre-clinical investigations.

A COMPARATIVE STUDY OF VARIOUS TYPE OF AUTOGENEOUS BONE GRAFT ON THE RABBIT-SKULL DEFECT HEALING (가토 두개골에 이식한 다양한 형태의 자가골에 의한 골성 회복 양상 비교 평가)

  • Choi, So-Young;Lee, Su-Youn;Kim, Jin-Wook;Kim, Chin-Soo;Lee, Sang-Han;Shin, Hong-In;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.428-434
    • /
    • 2008
  • Introduction: Piezosurgery device is one of the most commonly used instrument on the intraoral surgery such as maxillary sinus lift and autogeneous bone graft. Piezosurgery instrument also contains the tips that are manufactured especially for the convenient bone graft, which now many surgeons apply them for collecting bone graft materials in the curettage method for the restoration of skull defects. However, objective data has not been shown concerning the effects about bone graft with using Piezosurgery. Therefore we investigated the effects of Piezosurgery on the rabbit-skull defect healing. Materials & Methods: To investigate the regeneration of the bony defect with various bone graft, 10 adult New Zealand white rabbits (average weight : $2.8{\pm}0.3kg$, about 12weeks) were used. The four circular bony defects measuring 6mm in diameter were made with Piezosurgery device on each rabbit cranial bone. The harvested bone tissues during defect formation were also used for autogeneous bone graft. They were grafted into the defects in a various type; block type (Group 1), particulated type by the bone mill (Group 2), chopped type by curette shaped Piezosurgery tip (Group 3), the defect without any graft was served as control (control group). The animals were sacrificed after 6 weeks and bone regeneration capacity was evaluated histomorphometrically. Result & Conclusion: Autogeneous bone graft harvested using a Piezosurgery instrument showed satisfactory bone regeneration. There was no conspicuous difference bone prepared among by bone mill or Piezosurgery and block bone graft. Therefore, the bone harvested from the intraoral site near the operation field using the piezosurgery device can be a feasible and reliable graft for intraoral bony defects.

A study on assessment of bone mass from aluminum-equivalent image by digital imaging system (디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구)

  • Kim Jin-Soo;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.87-97
    • /
    • 1997
  • The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

  • PDF

The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study (인조골에서 식립 방법이 교정용 미니 임플란트의 기계적 안정성에 미치는 영향에 대한 예비연구)

  • Cho, Il-Sik;Choo, Hye-Ran;Kim, Seong-Kyun;Shin, Yun-Seob;Kim, Duck-Su;Kim, Seong-Hun;Chung, Kyu-Rhim;Huang, John C.
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.354-360
    • /
    • 2011
  • Objective: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. Methods: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. Results: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. Conclusions: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.

Vertical and Horizontal Ridge Augmentation Using Autogenous Tooth Bone Graft Materials: Case Report (자가치아골이식재를 이용한 치조능 수직 및 수평증대술: 증례보고)

  • Kim, Young-Kyun;Kim, Su-Gwan;Um, In-Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.2
    • /
    • pp.166-170
    • /
    • 2011
  • Horizontal and vertical ridge augmentation was performed using autogenous tooth bone graft block and powder in 44-year old male patient. Excellent bony healing was obtained 2~4 months after ridge augmentation. Implant treatment was performed successfully.

Subtalar Distraction Bone Block Arthrodesis (Five Cases) (거골하 신연 골편 관절 유합술)

  • Yoo, Chong-Il;Eun, Il-Soo;Jung, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.101-106
    • /
    • 2004
  • Purpose: To determine the efficacy of the SDBBA (Subtalar distraction bone block arthrodesis) procedure on patients with late complication of intra-articular calcaneal fractures including subtalar joint arthritis and anterior ankle impingement syndrome. Materials and Methods: Five cases in which the SDBBA procedure was implemented were followed for more than one year. All five patients were male with an average age of 56. Clinically, the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score and the pain score were assessed. Radiographically, the talocalcaneal height and the talar inclination angle were determined. Results: All five patients achieved subtalar joint fusion. The average pre-operative AOFAS score was 22.8 scores (range, 8-32 scores). At last follow-up, these scores improved to an average of 72.4 scores (range, 64-82 scores). The average pre-operative pain score was 8.2 scores (range, 7-10 scores). At last follow-up, these scores improved to an average of 13.2 (range, 12-15 scores). The average pre-operative talocalcaneal height was 72.8 mm (range, 70-77 mm), average post-operative talocalcaneal height improved to 79.8 mm (range, 78-84 mm). At final follow-up, these measurement was slightly decreased to average 78.6 mm (range, 74-83 mm). The average pre-operative talar inclination angle was 13.2 degrees (range, 12-15 degrees), average post-operative talar inclination angle improvedto 19.2 degrees (range, 15-24 degrees). At final follow-up, these measurement was slightly decreased to average 18.6 degrees (range, 12-24 degrees). Four patients achieved successful outcomes. One patient developed a wound infection with subsequent sural neuropathy as well as collapse of the bone graft. Conclusion: This study shows that the SDBBA procedure successfully restores the talocalcaneal height and tibio-talar relationship. This procedure is useful in surgically managed patients with talo-calcaneal height loss and anterior ankle impingement syndrome due to the late complications of calcaneal intra-articular fractures.

  • PDF

AN EXPERIMENTAL STUDY OF THE EFFECTS OF BONE WAX ON THE MOUSE FEMORAL BONE DEFECTS (백서 대퇴골 결손부에 매식된 밀랍지혈제의 조직반응에 관한 실험적 연구)

  • kim, Jang-Yun;Han, Kyung-Su;Um, In-Woong;Chung, Ho-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-236
    • /
    • 1992
  • This study was to designed to evaluate the reactions of mouse femoral bone to bone wax. In sixteen mice with a strain of I. C. R. mouse weighed approximately 300 to 850g 2.0~2.0mm sized bone defects were created by drilling. Half of mice were inserted by bone wax and the remainder serving as control without bone wax application. The mice were sacrificed 1, 2, 6, 8 weeks after operation and block specimens were prepared for light microscopy examination. The results obtained were as follows. 1. Histologic features of tissue reaction to bone wax were the presence of inflammatory cell infiltration and multinucleated giant cell. 2. Bone ear healing from the created margin were markedly impaired by the application of bone wax 3. New bone formation was markedly decreased in bone wax application.

  • PDF

BONE GRAFT PROCEDURE WITH ENDOSSEOUS IMPLANTS : A REVIEW OF THE LITERATURE (골유착성 임프란트와 관련된 골 이식술에 대한 문헌 고찰)

  • Moon, Se-Ki;Chung, Ho-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.533-539
    • /
    • 2000
  • Recent development of dental implantology has taken an interest in the bone graft procedure. This is a review of literature, published from 1994 to November 1999. This study is provided by MEDLINE search. In this study, 718 patients received 829 graft with placing 2,677 endosseous implants. In mandible, nonvascularized or vascularized block bone grafts provided better results(success rate 95.2%) than particulate grafts(83.6%). But in maxilla, particulate grafts provided better results(93.7%, 86.2%) and more cases especially in sinus elevation. There were many cases using autogenous bone graft and revealed good results, but allogenic or alloplastic bone graft materials also were used by many surgeons.

  • PDF

THE ROLE OF THE PERIOSTEUM IN IMPLANTATION OF TOOTHASH AND PLASTER OF PARIS IN THE RATS;AN EXPERIMENTAL STUDY (백서에서 치아 회분말과 치과용 연석고의 혼합매식술시 골막의 역할;실험적 연구)

  • Kim, Su-Gwan;Yeo, Hwan-Ho;Cho, Jae-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.3
    • /
    • pp.319-331
    • /
    • 1997
  • The purpose of this study was to evaluate the bone-forming capacity of the periosteum in calvaria of rats. The experiment was carried out in 49 rats. We exposed the calvaria and made 1㎝ diameter round full thickness defect at both sides of calvaria. In the left calvarial bone serving as control, the periosteum was removed after implantation of block, while in the right calvarial bone the periosteum remained intact as an experimental site. The histologic examination of bone response was performed after 1-, 2-, 4-, 6-,8-, 12-, 24-week implantation in calvaria of rats. We could observe the periosteal preservation favorably influenced the bone formation.

  • PDF