• Title/Summary/Keyword: Block Diagram

Search Result 208, Processing Time 0.022 seconds

A Study on Plant Training System Platform for the Collaboration Training between Operator and Field Workers (운전자와 현장조업자의 협동훈련을 위한 플랜트 훈련시스템 플랫폼 연구)

  • Lee, Gyungchang;Chung, Kyo-il;Mun, Duhwan;Youn, Cheong
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.420-430
    • /
    • 2015
  • Operator Training Simulators (OTSs) provide macroscopic training environment for plant operation. They are equipped with simulation systems for the emulation of remote monitoring and controlling operations. OTSs typically provide 2D block diagram-based graphic user interface (GUI) and connect to process simulation tools. However, process modeling for OTSs is a difficult task. Furthermore, conventional OTSs do not provide real plant field information since they are based on 2D human machine interface (HMI). In order to overcome the limitation of OTSs, we propose a new type of plant training system. This system has the capability required for collaborative training between operators and field workers. In addition, the system provides 3D virtual training environment such that field workers feel like they are in real plant site. For this, we designed system architecture and developed essential functions for the system. For the verification of the proposed system design, we implemented a prototype training system and performed experiments of collaborative training between one operator and two field workers with the prototype system.

A Study on the Dynamic Reconfiguration Algorithm of Components for Multi-mode SDR Terminal (다중모드 SDR 단말을 위한 동적 컴포넌트 재구성 알고리즘 연구)

  • Kwon, Oh-Jun;Oh, Sang-Chui;Park, Nam-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.9
    • /
    • pp.1277-1285
    • /
    • 2008
  • In this paper, we first design the block diagram of the components for multi-mode SDR terminal based on SCA technology. It support both WIMAX mode and HSDPA mode. Then from the result of the analysis with a real SDR terminal implementation, we analyze which components of it have to be more lightweight. In addition we derive the general formula for the measure of dynamic reconfiguration time on the reconfiguration of the components. Finally we present a dynamic component-level reconfiguration algorithm with 22 stages based on the result of our analysis without violating the interface and procedure of SCA specification.

  • PDF

Direct Current Control Method Based On One Cycle Controller for Double-Frequency Buck Converters

  • Luo, Quanming;Zhi, Shubo;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.410-417
    • /
    • 2012
  • In this paper, a direct current control method based on a one-cycle controller (DCOCC) for double frequency buck converters (DF buck) is proposed. This control method can make the average current through the high frequency and low frequency inductors of a DF buck converter equal. This is similar to the average current control method. However, the design of the loop compensator is much easier when compared with the average current control. Since the average current though the high frequency and low frequency inductors is equivalent, the current stress of the high frequency switches and the switch losses are minimized. Therefore, the efficiency of the DF buck converter is improved. Firstly, the operation principle of DCOCC is described, then the small signal models of a one cycle controller and a DF buck converter are presented based on the state space average method. Eventually, a system block diagram of the DCOCC controlled DF buck is established and the compensator is designed. Finally, simulation and experiment results are given to verify the correction of the theory analysis.

A Study on the Equivalent Model of an External Electrode Fluorescent Lamp Based on Equivalent Resistance and Capacitance Variation

  • Cho, Kyu-Min;Oh, Won-Sik;Moon, Gun-Woo;Park, Mun-Soo;Lee, Sang-Gil
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2007
  • An External Electrode Fluorescent Lamp (EEFL) has longer lifespan, higher power efficiency and higher luminance than a Cold Cathode Fluorescent Lamp (CCFL). Moreover, it is easy to drive them in parallel. Therefore, the EEFL is expected to quickly replace the CCFL in LCD backlight systems. However, the EEFL has more complex characteristics than the CCFL with a resistive component, because it has both a resistive component by plasma and a capacitive component by external electrode. In this paper, values of resistance and capacitance are measured at several power levels and at several operating frequencies. They are expressed by a numeral formula based on a linear approximation that represents the equivalent resistance and capacitance as a function of power. Then we made block diagram of the equivalent circuit model using numerical expressions. Simulation waveforms and experimental results are presented to verify the feasibility of the equivalent model.

신규 가입자망 기술의 경제성 평가를 위한 망 구조모형과 그 응용

  • 류태규;이정동;김태유
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.45-67
    • /
    • 2000
  • Broadband access technologies plays an important role in the national information infrastructure. In the evolution path of the information infrastructure, the relative economics of alternative access technology is the most critical determining factor. In this paper, we discuss the economics of local loop access technologies of existing technologies, such as, ADSL, HFC, and new PLC. To do this, we suggest appropriate configuration of access network system and its associated numerical equations. To modelize access network system and drive the numerical equations, we consider the DS (Double Star) and the T&B (Tree & Brench) architecture and analyse the adequate block diagram of each access system for each technology We introduce the density of subscriber as a key variable and the equation of allocating optimal number of cell in a service area. We analyze the relative economics of local loop architecture in two different situations, that is, urban and rural. From the empirical implementation, we found that for the case of urban area, where the cost of cable and infrastructure is not necessary, there is not much difference in the cost per one subscriber. However, for the case of rural region, we found that there is remarkable difference in the cost per one subscriber among technologies. Therefore we conclude that the economics of local loop architecture is depend on the density of subscriber and existing network infrastructures. we hope that this paper contribute to the optimal technology selection of consmer, technology Providers, and government.

  • PDF

A Study on High Efficiency Vector Controlled Induction Motor Drive System (고효율 벡터제어 유도전동식 구동 시트템에 관한 연구)

  • Kim, Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1174-1182
    • /
    • 1990
  • A hgih efficiency and good dynamic performance drive system of an induction motor is presented in this paper using vector control technique. If the induction motor is driven under light loads with rated flux, the iron loss is excessively large compared with the copper loss, resulting in poor motor efficiency. High efficiency drive of an induction motor can be achieved by adjusting the flux level which leads the total motor loss to be a minimum value. Generally reducing the flux degrades the dynamic performance, but the dynamic performance of the proposed system is also maintained high. If the d-axis is coincident with rotor flux phasor in synchronous rotating reference frame, the stator current can be decoupled as flux component and torque component. At steady state, the developed motor torque is proportional to the product of the flux and torque component. The combination of the two components minimizing the motor loss could be found with numerical method. As the procedure to obtain the optimal combination is too hard, it is found experimentally. The system block diagram is suggested for maximum efficiency control. The proposed system is studied through digital simulation and verified with experiment. The experimental results show the possiblity of a high efficiency drive with good dynamic performance of maximum efficiency control.

  • PDF

A Study on Integrated SE Process for the Development of the Railway Systems with Safety Assessment Included (철도 시스템 개발에서 시스템공학 프로세스와 안전성 평가를 동시에 고려한 통합 프로세스에 관한 연구)

  • Yoon, Jae-Han;Lee, Jae-Chon;Hong, Seon-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.438-443
    • /
    • 2007
  • This paper proposes an integrated SE process for the development of railway systems with safety assessment included. Although the safety assessment process must be performed with SE process properly with good coordination, the interfaces between the two processes have not been clear. Thus, in many of safety critical system developments in Korea, it is difficult to assess safety in proper development phase. The process model proposed in this paper is based on both the concept of system life cycle and the repetitive use of SE process. In each of development phases, appropriate safety assessment methods are described. Also the evaluation of the integrated system incorporating safety factors is described. The resultant process model is expressed by the Enhanced Functional Flow Block Diagram (EFFBD) using a CASE tool. The model also allows timeline analysis for identifying activity flow and data flow, resulting in the effective management of process. In conclusion, the integrated process enable both the SE process and safety assessment process to cooperate with each other from early development phase throughout the whole system life cycle.

Development of PSCAD User-defined Model for the Simulation of a PV Array (PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발)

  • Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

On the Development of Preventive Electrical Safety Plan Using Operation Concept Document (시스템 운용 개념서 활용을 통한 예방적 전기안전 계획서 개발에 관한 연구)

  • Lee, Byoung-Gil;Lee, Jae-Chon;Shin, Heung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.73-81
    • /
    • 2008
  • The current electrical safety plan developed for the national electricity system has been playing an important role in handling a variety of electrical accidents. However, it can be more effective to prevent or reduce those accidents if a preventive electrical safety plan is available. In this paper, an approach to developing the safety plan is described. We first discuss the contents that should be included in the plan. Noting that an effective plan requires the system level consideration of all the factors affecting the safety issues, an operation concept document (OCD) is considered. The OCD can allow us to understand the behavior of the safety system based on the operation environment, the system functions, the performance requirements, all at the system level of the safety system. Thus, the OCD can be useful in developing the safety plan. A detailed description then follows on how the OCD is developed for the electrical safety system under study. Finally, we discuss how the developed OCD can be used in deriving the preventive electrical safety plan.

A Study on the Risk Reduction Method for Liquid Rocket Test Facility (액체로켓 시험설비에서의 위험감소 방법)

  • Lee Jung-Ho;Kim Yong-Wook;Bershadskiy V. A.;Kang Sun-Il;Cho Sang-Yeon;Oh Seung-Hyub
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.120-126
    • /
    • 2005
  • The method of decreasing the ecological risk for the LRE(Liquid Rocket Engine) test is developed, working on the cryogenic oxidizer and the high-boiling fuel(Kerosene). This Method is based on the study that contains a technical solution method and an accident occurrence range for decreasing of accident probability and damage. This paper contains schematic on the all risk circumstance bring to accident, block-diagram for an accident growth process in case of the propellant leakage, technical solution method and risk reduction evaluation method. It will be used to alternative method for the risk reduction of complex technical systems.