• Title/Summary/Keyword: Blind Conditions

Search Result 132, Processing Time 0.026 seconds

The Influences of Pulsed Electromagnetic Field Treatment Following Experimentally Induced Delayed-Onset Muscle Soreness in Biceps Brachii (펄스자기장이 위팔 두갈래근의 지연성 근육통에 미치는 영향)

  • Kang, Sun-Young;Park, Joo-Hee;Jeon, Hye-Seon;Lee, Hyun-Sook
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • Delayed onset muscle soreness (DOMS) is a painful condition that arises from exercise-induced muscle damage after unaccustomed physical activities. Various therapeutic interventions have been applied to reduce the intensity and duration of DOMS-related symptoms. Recently, pulsed electromagnetic field (PEMF) intervention has been introduced as an alternative noninvasive treatment for DOMS. This randomized, double-blind, placebo-controlled experiment was conducted to examine the effects of PEMF therapy on DOMS in elbow flexors at 24, 48, and 72 hours after the experimental DOMS induction. Thirty healthy volunteers ($23{\pm}2.4$ yrs, $175{\pm}5.7$ cm, and $74{\pm}7.8$ kg) participated in this study. Each was randomly assigned to a PEMF or placebo group. On the first day, DOMS was induced in the elbow flexors by repeated isokinetic motions at low ($60^{\circ}/s$) and fast ($120^{\circ}/s$) speeds in all subjects. Thereafter, the PEMF group received 15-min daily treatment with a PEMF device. The placebo group received sham treatment of the same duration. Overall, PEMF application was more effective than the sham treatment in reducing the physiological symptoms associated with the DOMS including perceived soreness, median frequency, and electromechanical delay of the surface electromyography. In addition, median frequency and isokinetic peak torque of the PEMF group recovered to the pre-DOMS induction level earlier than the placebo group. In conclusion, this study suggests that PEMF can be applied as a new recovery strategy in reducing DOMS symptoms. Further experiments are required to examine the effect of the PEMF treatment on different types of exercise conditions and to determine the optimal treatment dosage and duration in a real clinical setting.

An Architectural Study on the Improvement of Energy Efficiency of Public Institution - Focused on Public Office Buildings Remodeling of Passive Design Elements - (공공기관 에너지 효율등급 향상을 위한 적용 설계요소에 관한 연구 - 공공청사 리모델링시 패시브 디자인요소를 중심으로 -)

  • Cho, Jung-Chul;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.114-120
    • /
    • 2012
  • There are lots of buildings which were built before the Legislation on building energy rating system. Remodeling of the buildings would be required for an improvement of the building energy rating system was enforced by the government. In the Passive Building Design, Elements which will be used for the remodeling are Insulation, Window, External venetian blind, Heat exchanger. The Purpose of this study is to indicate a Method for the improvement of Energy saving by an analysis of Construction Cost, Cost Evaluation, Energy performance Efficiency in applied design elements. In this study, the remodeling of existing public buildings to improve energy efficiency rating was applied to extract the elements of design-specific energy performance, efficiency, and the application of the designs that has been analyzed. The results were as follows: applying the design-specific cost-effective investment that represents the economy (investment efficiency/%) surveyed the average insulation(7.0%), triple glazed windows(10.1%), double glazed windows(12.1%), external shading(24.5%), and Heat(77.2%) were analyzed in order to be more efficient. Analysis of the basis of information on the existing public buildings to improve energy efficiency rating for the remodeling depending on driving conditions at a degree of individual difference. The main effect, however, depending on economic investment, design elements, heat exchangers, external awning, double glazed windows, triple glazed windows, insulation, is recommended as review of the order shall be determined.

  • PDF

A Clinical Trial about Anti-anxiety and Anti-stress Effect of a modified formula consisted with Several Herbs (발아현미와 수종한약재 추출액의 스트레스 및 불안상태 개선 효과에 대한 임상연구)

  • Kim Lak Hyung;Jang In Soo;Kim Jeong Yun;Song Jeong Mo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.6
    • /
    • pp.1533-1537
    • /
    • 2003
  • This double-blind randomized clinical trial was performed to evaluate the anti-anxiety, anti-stress effect of a modified formula WS-01 consisted with several herbs(Jujubae Fructus. Longanae Arillus. Poria Cocos) and germinated rice. The extract of the formula was administered (p.o) to 24 students and placebo was to 23 students for 4 weeks. STAI-KYZ(Hahn. Hakjisa), ABR2000(Meridian, Korea), CBC, LFT, U/A were checked before and after the administration period. There was no difference between the STAI score of WS-01 and that of placebo group in first test. But the STAI state anxiety score was 5.33±7.33 reduced in WS-01 group and it was 0.52±6.42 increased in placebo group in second test. this result was significant stastically. 10 students in WS-01 group showed improving result, but only 1 student in placebo group showed improving result of ABR2000 test. The result of ABR2000 was analyzed with curve 2, Regulation 2, and graph 1,2,3, because those reflect central nerve system and stressful condition of the body. There was no significant result in first and second CBC, LFT, Urine test. The results of this clinical study suggest that WS-01 has anti-anxiety, anti-stress effect, and it could be applied to various conditions or disorders related with anxiety and stress.

The Analgesic Effects of Transcutaneous Electrical Nerve Stimulation and Interferential Currents on the Experimental Cold Pain Model : Frequency 50 Hz and 100 Hz (실험적 냉각 통증 모델에서 경피신경전기자극과 간섭파전류의 진통 효과 비교 : 주파수 50 Hz과 100 Hz)

  • Bae, Young-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4045-4052
    • /
    • 2012
  • The aim of this single blind intervation study was to compare the analgesic effects of transcutaneous electrical nerve stimulation (TENS) and interferential currents (IFC) on cold-induced pain in healthy volunteers. Sixteen subjects completed six cycles of the cold-induced pain test. During each cycle pain threshold was recorded as the time from immersion of the subject is hand in cold water to the first sensation of pain and pain intensity and unpleasantness ratings were recorded using visual analogue scales. Subjects were randomly allocated to receive each 50 Hz-TENS, 50 Hz-IFC, 100 Hz-TENS and 100 Hz-IFC. Statistical analysis showed that four interventions elevated the cold pain threshold significantly and the difference between interventions was not simply significant. But, no significant differences were identified in pain intensity and unpleasantness ratings. We conclude that there were no differences in the analgesic effects of the four interventions under the present experimental conditions. But, 50 Hz-IFC has been shown to be more comfortable than other interventions.

A Study to Determine the Degree of Difficulties with the Excavation of Corestone Weathering Profiles (핵석지반에서의 굴착난이도 평가방법 연구)

  • Lee, Su-Gon;Lee, Byok-Kyu;Kim, Min-Sung
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.89-99
    • /
    • 2007
  • This paper intends to introduce more objective and qualitative rock mass classification method easily applicable to the excavation of gneissic masses showing corestone weathering profiles. It is proven that corestone weathering profile could be divided with reasonable accuracy into digging, ripping and blasting layers using visual and simple mechanical techniques such as Schmidt hammer rebound test on cut slopes, taking into consideration strength and spacial distribution of corestone, workability and work efficiency of excavation. Also, seismic refraction surveys were employed for shallow investigations (down to $20{\sim}30m$ depth) in corestone weathering profile and conducted across the top of vertical exposures where the underlying geology could be directly inspected. Some discrepancies ($3{\sim}4m$ in average and 6 m occasionally) between the actual and assumed materials with respect to seismic velocities were observed. Thus it can be concluded that field geotechnical mapping and field seismic test should be used together in order to get a relatively good accuracy in assessing likely excavation conditions of corestone weather-ing profiles.

Pain alleviation in patients undergoing cardiac surgery; presternal local anesthetic and magnesium infiltration versus conventional intravenous analgesia: a randomized double-blind study

  • Kamel, Emad Zarief;Abd-Elshafy, Sayed Kaoud;Sayed, Jehan Ahmed;Mostafa, Mohammed Mahmoud;Seddik, Mohamed Ismail
    • The Korean Journal of Pain
    • /
    • v.31 no.2
    • /
    • pp.93-101
    • /
    • 2018
  • Background: Magnesium is one of the effective, safe local anesthetic adjuvants that can exert an analgesic effect in conditions presenting acute and chronic post-sternotomy pain. We studied the efficacy of continuous infusion of presternal magnesium sulfate with bupivacaine for pain relief following cardiac surgery. Methods: Ninety adult patients undergoing valve replacement cardiac surgery randomly allocated into three groups. In all patients; a presternal catheter was placed for continuous infusion of either 0.125% bupivacaine and 5% magnesium sulfate (3 ml/h for 48 hours) in group 1, or 0.125% bupivacaine only in the same rate in group 2, versus conventional intravenous paracetamol and ketorolac in group 3. Rescue analgesia was iv $25{\mu}g$ fentanyl. Postoperative Visual Analog Scale (VAS) and fentanyl consumption during the early two postoperative days were assessed. All patients were followed up over two months for occurrence of chronic post-sternotomy pain. Results: VAS values showed high significant differences during the first 48 hours with the least pain scale in group 1 and significantly least fentanyl consumption ($30.8{\pm}7{\mu}g$ in group 1 vs. $69{\pm}18{\mu}g$ in group 2, and $162{\pm}3$ in group 3 respectively). The incidence of chronic pain has not differed between the three groups although it was more pronounced in group 3. Conclusions: Continuous presternal bupivacaine and magnesium infusion resulted in better postoperative analgesia than both presternal bupivacaine alone or conventional analgesic groups.

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

A Study on Environmental Pollution Issues in Fireworks Display (불꽃놀이의 환경오염 측면에 관한 연구)

  • Ahn, Myung-Seog;Lee, Jin-Ho;Shin, Chang-Young
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.45-51
    • /
    • 2008
  • Fireworks display is called as younwha in korean, pokjuk in chinese, hanabi in japanese and fireworks display in English. Fireworks is a kind of art calling as engineering art program that presents its artistic sense by making up light, sound, heat, form, smoke, smoke screen, time delay and kinetic energy etc. which are made by combustion and deflagrations of explosives. Korea's fireworks skill is world class. In 1980s, we already developed the skills. After 2010 year, It would develop as Nano-biotechnology considering its environmental safety passing by 1990s' grow fully step. After pleasant fireworks, it requires a environmental pollution control measure, ability of emergency state control, management of storing place, a blind shell and waste disposal and citizenship elevation etc. This paper indicated around fireworks the present conditions, environmental pollution buzz, direction of development and plan.

Study on Installation of Sector Lights for the Establishment of Safe Navigation Environment in Busan Port (부산항 안전항해환경 조성을 위한 지향등 설치방안 연구)

  • JEONG, Hae-Sang;LEE, Jong-Cheol;KIM, Jeong-Rok;GUG, Seung-Gi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.87-88
    • /
    • 2019
  • Leading Lights and Sector Lights provide a navigable channel, heading reference and a visual indication. Mariners can take easily a reference bearing or line of position. The Busan North Port needed to install a sector light to resolve blind sections because of Busan Port Redevelopment Project D-1 Block Construction Plan. And also the busan new port needed to install a sector light to give safety indication because navigation conditions will be changed due to removal of the to-island. For this reason, design development was made for installation of sector lights. In addition, the results of design development were compared with the AtoN simulation and verified. This paper is expected to be very useful for installing Sector Lights to guide the vessel to port safely in Korea.

  • PDF

An Artificial Intelligence Method for the Prediction of Near- and Off-Shore Fish Catch Using Satellite and Numerical Model Data

  • Yoon, You-Jeong;Cho, Subin;Kim, Seoyeon;Kim, Nari;Lee, Soo-Jin;Ahn, Jihye;Lee, Eunjeong;Joh, Seongeok;Lee, Yang-Won
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.1
    • /
    • pp.41-53
    • /
    • 2020
  • The production of near- and off-shore fisheries in South Korea is decreasing due to rapid changes in the fishing environment, particularly including higher sea temperature in recent years. To improve the competitiveness of the fisheries, it is necessary to provide fish catch information that changes spatiotemporally according to the sea state. In this study, artificial intelligence models that predict the CPUE (catch per unit effort) of mackerel, anchovies, and squid (Todarodes pacificus), which are three major fish species in the near- and off-shore areas of South Korea, on a 15-km grid and daily basis were developed. The models were trained and validated using the sea surface temperature, rainfall, relative humidity, pressure,sea surface wind velocity, significant wave height, and salinity as input data, and the fish catch statistics of Suhyup (National Federation of Fisheries Cooperatives) as observed data. The 10-fold blind test results showed that the developed artificial intelligence models exhibited accuracy with a corresponding correlation coefficient of 0.86. It is expected that the fish catch models can be actually operated with high accuracy under various sea conditions if high-quality large-volume data are available.