블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성 (Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding)

  • 김기훈;황인성;나운;임주혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content arc satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When, AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

블리딩저감용 AE감수제를 사용한 콘크리트의 블리딩 저감 특성 (Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for Reduction of Bleeding)

  • 김기훈;황인성;나운;임주혁;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.69-72
    • /
    • 2003
  • This study is intended to investigate the fundamental properties of concrete which AE water reducing agent for reduction of bleeding is used, and the properties of bleeding reduction. According to the results, when the adding ratio of AE water reducing agent for reduction of bleeding increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 60 min. When. AE water reducing agent for reduction of bleeding is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for reduction of bleeding. Synthetically, it proves that AE water reducing agent for reduction of bleeding satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

  • PDF

블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성 (Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction)

  • 한천구;황인성;이승훈;김규동
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

단위수량 및 증점제량이 콘크리트의 블리딩에 미치는 영향 (Influence of Unit Water and Viscosity Agents Contents on the Bleeding of Concrete)

  • 김은호;심보길;황인성;전충근;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.232-328
    • /
    • 2001
  • This paper investigates the influences of water content and viscosity agent on the bleeding of concrete. According to test results, fluidity shows decline tendency as water content decreases, and dosage of viscosity agent increases. PEO viscosity agent does not affect the air contents while, MC viscosity agent causes air loss. As for bleeding, bleeding decreases with decrease of water content. As dosage of viscosity agent increase, bleeding decreases, regardless of viscosity kinds. It is thought that viscosity agents have the favorable effect of reducing bleeding, if fluidity and air loss are improved.

  • PDF

블리딩 저감용 AE감수제 개발에 관한 기초적 연구 (A Fundamental Study on the Development of AE Water Reducing Agent for Reduction of Bleeding)

  • 문학용;김한준;김규용;신동인;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.75-78
    • /
    • 2003
  • This study is to investigate the probability to develop the AE Water-reducing agent which can decrease the bleeding by mixing melamine type super-plasticizer(SP) and methyl cellulose(MC) viscosity agent. According to the result, as the mixing ratio of melamine type SP and MC viscosity agent increases, the bleeding is reduced due to a increase of the air content. When the mixing ratio of melamine type SP and MC viscosity agent is 1:2 and 1;3 at the water content of 165kg/$m^3$ and 175kg/$m^3$ respectively, slump and air content are satisfied and bleeding is reduced to some extent, so this is determined as the mixing ratio of AE water reducing agent for reduction of bleeding. It is prove that the developed AE water reducing agent for reduction of bleeding can reduce the amount of bleeding and prohibit the plastic shrinkage crack by slowing down the bleeding speed. Compressive strength of hardened concrete does not make any difference in comparison with plain concrete.

  • PDF

콘크리트의 블리딩에 미치는 혼화제의 영향 (Influence of Chemical Admixture on Bleeding of Concrete)

  • 김은호;황인성;손유신;김규용;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.339-342
    • /
    • 2003
  • This study is intended to investigate the influence of chemical admixture on bleeding of concrete. According to the results, the amount of bleeding with elapse of time does not make much difference in the case of naphthalene type water reducing agent(RN), Naphthalene type high performance water reducing agent(HN) and Melamine type high performance water reducing agent(HM), but it is largest in the case of Polycarbonic acid type high performance water reducing agent(HP). Bleeding speed also is highest in the case of HP in comparison with other chemical admixture. This prove that high performance water reducing agent like HP has little effect on fluidity of concrete, but influences the amount of bleeding more greatly, instead. As properties of hardened concrete, compressive strength makes no difference in the case of RN, HN and HM, but on the other hand, it increases in the case of HP due to a decrease of air content and the large amount of bleeding.

  • PDF

콘크리트의 블리딩에 미치는 배합 및 시공요인의 영향 (Influence of Mixing and Construction Factor on the Bleeding of Concrete)

  • 황인성;김경민;전충근;신병철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.265-268
    • /
    • 2002
  • This study is focused on the influence of mixture and construction factor on bleeding amount of concrete According to the results, Amount of bleeding with mixture factor increases with increase of water contents and W/C. Amount of bleeding with construction factors is larger in the case of placing height of 1m than in the case of placing height of 0 and 0.5m. Amount of bleeding is larger at the temperature of 20℃ than at the temperature of 35℃ and 5℃, and increases in order of vibration compacting, standard lamping and non tamping. Therefore, to reduce bleeding, it is thought that it is profitable to reduce water content within the range that fluidity and workability don't go bad, to lower the placing height and not to do compacting too much.

  • PDF

고성능감수제 종류에 따른 유도화콘크리트의 Bleeding특성 (A Study on the Bleeding Property of Flowed Concrete Due to Different Types of High Range Water Reducing Admixtures)

  • 김기수;하재담;김동석;신규연;유규홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.321-326
    • /
    • 1997
  • Recently, High Range Water Reducing Admixture be used increasingly in other to improve the demanded properties (fluidity, strength, durability etc.) and workability in concrete. These kinds of agent govern quality characteristics (air content, setting time, slump, bleeding etc) by the difference of its dispersing mechanism and performance in manufacture of flowed concrete. Accordingly, in this study, for the purpose of high quality construction in site, the comparative experiment of dispersing ability due to commercially available three types of agent were carried out in paste, mortar and concrete using tow types of cement (I, V). In conclusion, the bleeding reduction by the dispersing ability of agents was verified in the fresh properties of flowed concrete with sea water resistance.

  • PDF

Water jet 사용시의 구강청결 효과에 관한 임상적 조사연구 (A Clinical Study on Effect of Mouth Cleaning by Use of Water jet)

  • 김용성;김경민;신승철
    • 보건교육건강증진학회지
    • /
    • 제11권1호
    • /
    • pp.85-94
    • /
    • 1994
  • The purpose of this study is to provide a guide for selection of oral hygiene devices for nations and establishing valid indication of recently popularized water jet. The author has divided 36 persons into general, orthodontic, periodontal patients according to their oral hygiene state, and then evaluated the degree or decrease in plaque indices and gingival bleeding indices. The obtained results were as follows. 1. When both manual toothbrush and water jet were used together by three kind of patients, significant decreases in plaque index were observed in all patients, after 4 weeks compared with ordinary toothbrushing only(p<0.05). 2. When both oral hygiene devices were used together by three kind of patients, significant decreases in gingival bleeding index were observed in all patients after 4 weeks compared with ordinary toothbrushing only(p<0.05). 3. Singificant differences of the average gingival bleeding index & plaque index among three kind of patients were observed(p<0.05). 4. Therefore, it is concluded that for effective oral hygiene care. water jet can be recommendable to general patients, especially to orthodontic or periodontal patients.

  • PDF

열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석 (An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.512-520
    • /
    • 2020
  • 개방형 지중열교환기(SCW)는 수직 밀페형 지중열교환기에 비해 높은 용량과 효율을 갖고 있어 최근에 우리나라에서 많이 보급되고 있는 추세이다. SCW형 지중열교환기의 여러 설계 및 운전변수 중 블리딩 운전이 지중 열전도율, 보어홀 열저항 등 열성능 개선에 가장 효과가 큰 것으로 보고되고 있다. 본 연구에서는 SCW형 지중열교환기가 설치된 현장의 열응답시험 결과를 기반으로 블리딩해석 모델을 정립하고 블리딩율 및 지하수 유입수의 위치변화가 SCW형 지중열교환기 열성능에 미치는 영향을 수치해석을 통하여 고찰하였다. 해석결과 지하수가 지중열교환기 상부에서 유입될 경우 지중열교환기 순환수의 시간에 따른 온도증가는 블리딩율이 증가함에 따라 낮아지는 경향을 보였으며, 지중 열전도율은 30% 블리딩율에서 179% 증가하는 결과를 보였다. 반면에 지하수가 지중열교환기 하부에서 유입될 경우 지중열교환기 순환수는 지중과 먼저 열교환을 한 후 유입수와 하단에서 혼합되기 때문에 지중열교환기 순환수의 온도증가는 상부 유입의 경우보다 적으며 블리딩율이 약 10%를 초과하면 일정하게 유지되는 경향을 보였다.