• 제목/요약/키워드: Blade Holder

검색결과 4건 처리시간 0.021초

깊은 홈 및 절단가공용 드로우어웨이식 초경공구 시스템의 설계에 관한 연구 (A Study on the Design of Throw-away Cutting Tool System for Deep Grooving or Cut-off Machining)

  • 김형철;이우영;남궁석
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.123-130
    • /
    • 1996
  • The procedure on the design of a new tungsten cabide throw-away cutting tool system for deep grooving or cut-off machining is suggested. For relieving the maximum stress level at the corner radius of the blade holder, the finite element method is used. Also the pulling test device is proposed for measuring the holding force of the insert between the blade holder and the insert considering the materials in contact and configuration parameters of the holder.

  • PDF

금형 구조부 가공을 위한 CAM 시스템 안정성 조사 (Review of Safety for CAM System in Mold Structure Manching)

  • 김형만;김종걸
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2006년도 추계공동학술대회
    • /
    • pp.239-254
    • /
    • 2006
  • In mold structure machining, tool interference is a phenomenon which results from a collision between a blade of tool and a workpiece. Also tool collision is a phenomenon which results from a collision of holder with the object to be machined. These phenomena not only cause damages to mold and tool but also increase machining time and cost. To detect a collision of a tool to mold structure, first of all, the mold structure and a tool must be defined with famous geometric models such CSG, B-rep, and Voxel. A tool is defined as a combination of the blade, the shank, and the holder. This thesis reviews various collision detection algorithms using z-map and computer 3D graphic collision detection algorithms for the tool in machining a mold structure.

  • PDF

Standby Mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 관한 연구 (A Study on the Flame Pattern and the Electrical Properties of Electric Outlet Fired at Standby Mode)

  • 최충석;송길목;김형래;김향곤;김동욱;김동우
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.39-44
    • /
    • 2002
  • Standby mode에서 출화된 콘센트의 화염 패턴 및 전기적 특성에 대해서 분석하였다 탄화 패턴을 분석한 결과 불꽃은 약 50~70cm 정도 방사되었다. 가연물에 착화된 후 약 150sec 경과하였을 때 온도가 약 $300^{\circ}c$까지 상승했으며, 화염은 ceiling jet을 형성하며 급속도로 확산되었다. 트래킹은 극간의 최단거리를 형성하며 이루어졌으며 저항 값은 약 100~300$\Omega$을 나타냈다. 칼받이를 금속 현미경으로 분석한 결과 정상 부분은 비정질 구조를 나타냈으나, 트래킹에 의해 소손된 부분은 수지상 조직(dendrite structure)과 보이드(void)가 고르게 분포되어 있음을 알 수 있다. 용융된 칼받이를 SEM 및 EDX로 분석한 결고 ㅏ정상 부분과 용융된 부분의 구조와 조성 변화에 차이가 있다.

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.