• Title/Summary/Keyword: Bladder Pressure

Search Result 57, Processing Time 0.026 seconds

Development of an Improved Animal Model of Overactive Bladder: Transperineal Ligation versus Transperitoneal Ligation in Male Rats

  • Kim, Woo Hyun;Bae, Woong Jin;Park, Jung Woo;Choi, Jin Bong;Kim, Su Jin;Cho, Hyuk Jin;Ha, U Syn;Hong, Sung Hoo;Lee, Ji Youl;Hwang, Sung Yeoun;Kim, Sae Woong
    • The World Journal of Men's Health
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2016
  • Purpose: We compared a transperineal ligation model and a transperitoneal ligation model in male rats to determine which animal model of overactive bladder (OAB) was more useful based on cystometrography, estimations of oxidative stress, and measurements of pro-inflammatory cytokine levels. Materials and Methods: Male rats were randomly divided into three groups (n=15 in each): the control group, the transperineal ligation group, and the transperitoneal ligation group. Four weeks after the ligation procedure, cystometrography was performed and oxidative stress, pro-inflammatory cytokine levels, and histologic changes were evaluated. Oxidative stress was assessed by measuring 8-hydroxy-20-deoxyguanosine and superoxide dismutase, and pro-inflammatory cytokine activity was investigated by measuring levels of interleukin (IL)-6, IL-8, and tumor necrosis $factor-{\alpha}$. Results: The transperineal model led to results similar to those observed for the transperitoneal model, namely (1) increased voiding frequency and reductions in the non-voiding contraction interval and the maximal vesical pressure, (2) increased levels of oxidative stress markers, (3) increased pro-inflammatory cytokine levels, and (4) fibrotic changes in the bladder tissue. Conclusions: We suggest that the transperineal procedure can be used as an alternative OAB model in male rats.

An Improved Case Report of Interstitial Cystitis/Bladder Pain Syndrome Treated by Korean Medicine Treatment (한의 복합 치료로 호전된 간질성 방광염/방광통증증후군 1례 : 증례보고)

  • Hwang, Su-In;Yoon, Young-Jin;Park, Jang-Kyung
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.1
    • /
    • pp.82-92
    • /
    • 2021
  • Objectives: The purpose of this study is to report the clinical effectiveness of Korean medicine treatment on interstitial cystitis. Methods: The patient diagnosed with Interstitial cystitis/Bladder pain syndrome (IC/BPS) was treated with Korean medicine treatment during 22 days of hospitalization. The patient received Korean medicine treatment including herbal medicine, acupuncture, pharmacopuncture, moxibustion, cupping and extracorporeal magnetic stimulation therapy. The effect of treatment on IC/BPS was evaluated through the Numeric Rating Scale (NRS), voiding diary, and Interstitial Cystitis Symptom Index/Problem Index (ICSI/ICPI). Results: After the treatment, the clinical symptoms of IC/BPS such as pelvic pain, pelvic pressure, frequent urination and urinary urgency were improved. Also, the patient had better scores in ICSI/ICPI. Conclusions: This case report proved that the Korean medicine treatment may be effective for improving clinical symptoms of IC/BPS. However, a large-scale clinical study is needed in the future to prove the effectiveness of Korean medicine treatment for IC/BPS.

The Effects of Ginseng Saponin on Relaxation of Smooth Muscle in the Lower Urinary Tract and the Corpus Cavernosum (인삼 사포닌이 하부요로와 음경해면체 평활근의 이완작용에 미치는 효과)

  • Jung, Hee-Chang;Oh, Tae-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.52-61
    • /
    • 2006
  • Background: Korean ginseng (KG) has been used as a general tonic, and for voiding dysfunction for a long time in oriental society. However, scientific basic studies on the use of KG, have been rare, especially for voiding and erectile dysfunction. This study was performed to investigate the effects of KG on voiding and erectile function by examining the effects of total saponin (TS) on the bladder, urethral and penile cavernosal smooth muscle. Materials and methods: To examine the effects of TS, NewZeland white rabbits were used to obtain tissue strips from the smooth muscle of the bladder, proximal urethra and corpus cavernosum. Adult Sprague Dawley rats were used to examine the changes in urodynamic findings and penile erection after administration of TS. Results: In proximal urethral strips, the rate of relaxation of the proximal urethra was increased from $9.0{\pm}2.9$ to $33.7{\pm}4.8%$ in a dose-dependent manner when the concentration of TS was added accumulatively from 0.25 mg/ml to 4.0 mg/ml (p<0.05). However, no significant response was observed in the bladder strips within these concentration ranges. For the corpus cavernosal strips, the rate of relaxation ranged from $5.8{\pm}2.1$ to $36.7{\pm}5.8%$, increasing in a dose-dependent manner when TS was increased from 1.0 mg/ml to 4.0 mg/ml (p<0.05). After administration of 0.1 ml of TS (32 mg/ml) in the rat, the bladder pressure was $37.5{\pm}8.5$ mmHg at $52.1{\pm}7.0$ sec. during isovolumetric bladder contraction, showing no significant differences from $35.7{\pm}7.8mmHg$ and $50.7{\pm}7.2$ sec, respectively, before treatment. However, when 0.1 ml of TS (32 mg/ml) was administered, the relative reduction of urethral pressure was $6.9{\pm}0.5mmHg$ at $62{\pm}7.5$ sec, which was significantly higher compared to $4.6{\pm}1.1mmHg$ at $45{\pm}10$ sec before treatment (p<0.05). For the cavernosal injection study, the change in intracavernosal pressure (${\Delta}ICP$) was examined after administering 0.1 ml of TS. The cumulative additions of TS at concentrations from 0.5 mg/ml to 32 mg/ml increased ${\Delta}ICP$ from $1.3{\pm}0.5$ to $21.3{\pm}7.8mmHg$ in a dose-dependent manner (p<0.05). The duration of tumescence was from $0.3{\pm}0.1$ to $5.2{\pm}0.2$ min, showing dose-dependent increase (p<0.05). Furthermore, the cumulative addition of TS at concentrations from 0.5 mg/ml upto 32 mg/ml did not cause any significant change in systemic blood pressure. Conclusion: These results suggest that ginseng improves voiding functions, which is mainly achieved by TS relaxing the proximal urethra, the most important part of the bladder outlet function. In addition, ginseng safely induced a penile erection hemodynamically by relaxing the corpus cavernosum.

  • PDF

Integrated Effect of Non-Invasive Neuromodulation on Bladder Capacity in Traumatic Spinal Cord Injury Patient: Single Case Report

  • Priyanka Dangi;Narkeesh Arumugam;Dinesh Suman
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.86-94
    • /
    • 2024
  • Objective: To evaluate the changes in bladder capacity and storage through non-invasive neuromodulation by application of repetitive Trans magnetic stimulation (rTMS) and genital nerve stimulation (GNS) in traumatic spinal cord survivors. Design: A Single Case Study. Method: The Patient was registered in trail with the clinical trial registry of India (CTRI/2022/05/042431). The Patient was interposed with rTMS on lumbar area, from T11-L4 vertebrae with 1 Hz and the intensity was 20% below that elicited local paraspinal muscular contraction for 13 minutes. GNS was placed over dorsum of the penis with the cathode at the base and anode 2 cm distally at 20 Hz, 200 microseconds, Continuous and biphasic current was delivered and amplitude of stimulation necessary to elicit the genito-anal reflex. For assessment, Neurological examination was done for peri-anal sensation (PAS), voluntary anal contraction (VAC) and bulbocavernous reflex (BCR), deep anal pressure (DAP), and American Spinal Injury Association Impairment Scale (ASIA scale). Outcome assessment was done using Urodynamics, Spinal Cord Independence Measure Scale Version-III (SCIM-III), American Spinal Injury Association Impairment Score (ASIA Score), Beck's Depression Inventory Scale (BDI). The baseline evaluation was taken on Day 0 and on Day 30. Results: The pre-and post-data were collected through ASIA score, SCIM-III, BDI and Urodynamics test which showed significant improvement in bladder capacity and storage outcomes in the urodynamics study across the span of 4 weeks. Conclusion: rTMS along with GNS showed improvement in bladder capacity & storage, on sensory-motor score, in functional independence of individual after SCI.

Blood Pressure Cuff Bladders Tailored For Koreans (한국인 맞춤형 혈압계 커프 블래더)

  • Hwang, Lark Hoon;Park, Woo Sung;Na, Seung Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.822-829
    • /
    • 2013
  • Hypertension is one of the most common clinical diseases, with an increasing prevalence globally. Hypertension triggers various harmful consequences and affects multiple organs. Life-long care may be required in some cases. According to the Korea Center for Disease Control and Prevention, the prevalence of hypertension is gradually increasing. A 2011 survey revealed that 28.9% of Korean adults had hypertension. The prevalence rates were slightly higher among men than women. Accurate measurement of blood pressure(BP) is crucial to classify patients, to identify BP-related risks, and to inform correct treatment. For accurate blood pressure measurement, the use of a cuff bladder size appropriate for the mid-upper arm circumference(MUAC) is essential. Incorrect sized cuff bladder is one of the main causes of equipment error affecting sphygmomanometer accuracy. When commercial sphygmomanometers were examined, the cuff bladders differed from the dimensions specified in the ISO 81060-1:2007 standards. Undercuffing is responsible for a spurious overestimation of BP in patients with large arms leading to overdiagnosis of hypertension, whereas overcuffing (that is, use of relatively large cuffs with small arms), may be responsible for an opposite problem, leading to erroneous underestimation of BP levels. The cuff bladder sizes recommended by the American Heart Association(AHA) are an arm circumference(AC) of 17-25 cm for small-sized adults, AC of 24-32 cm for adults, AC of 32-42 cm for normal-sized adults, and AC of 42-50 cm for obese adults. In contrast, the AC of Korean adults ranges from 23-31 cm, belonging to a single type of adult bladder. Three types of bladders are necessary for Korean adults with an AC of 23-31cm. Hospitals often use one or two differently-sized Western cuffs for adult patients, which can yield inaccurate BP determinations. Cuff bladders with dimensions based on anthropometric reference data obtained from Koreans will aid hospitals to measure BP more accurately.

Dynamic Characteristics of an Antagonistic Actuation with Pneumatic Artificial Muscles (공압형 인공근육을 이용한 상극구동의 동적 특성)

  • Kang, Bong-Soo;Song, Seung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1081-1086
    • /
    • 2009
  • This paper presents dynamic characteristics of pneumatic artificial muscles. Since the actuating performance of a pneumatic muscle is closely related to the input pressure of a pneumatic muscle, the air flow model on a valve orifice and an elastic bladder of the muscle is formulated to estimate precisely the pressure variance of pneumatic muscles during deflating and inflating process. Frequency response experiments are performed with an antagonistic system consisting of two pneumatic muscles and fast pneumatic control valves. Comparing with experimental results, the proposed model yielded good performance in estimating dynamic motions of the antagonistic system as well as the pressure variance of the pneumatic artificial muscles

Usefulness Assessment of Noninvasive Bladder Pressure Measurement for BPH Diagnosis (전립선 비대증 진단에서의 비침습적 방광내압계측 유용성 평가)

  • Jeong, Do-Un;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.865-866
    • /
    • 2006
  • The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfort methods. There for in this study hardware device and computer software have been developed that enables the analysis of the urine flow rate and vesical pressure signal measured during voiding. These signals were recorded simultaneously and transmitted to the PC. For the measurement system evaluation, the model system for the lower urinary system of men was designed. From the evaluation of the model system, vesical pressure was correlated with the occlusion degree. In a pilot study on 5 male subjects, means of standard deviation was 1.06, average error rate was 2.09 and coefficient variation was 2.09.

  • PDF

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

Design of a Multiple Transmit Coil Driver for Implantable Telemetry Devices (원격 생체 측정 장치를 위한 다중 발신 코일 구동 드라이버 설계)

  • Ryu, Young Kee
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.609-614
    • /
    • 2015
  • Implanted telemetry systems provide the ability to monitor different species of animals while they move within their cages. Species monitored include mice, rats, rabbits, dogs, pigs, primates, sheep, horses, cattle, and others. A miniature transmitter implanted in each animal measures one or more parameters. Parameters measured include arterial pressure, intra-pleural pressure, left ventricular pressure, intra-ocular pressure, bladder pressure, ECG, EMG, EEG, EOG, temperature, activity, and other parameters and transmits the data via radio frequency signals to a nearby receiver. Every conventional dedicated transmitter contains one or more sensors, cpu and battery. Due to the expected life of the battery, the measuring time is limited. To overcome these problems, electromagnetic inductive coupling based wireless power transmission technology using multiple transmit coils were proposed, with each coil having a different active area driven by the coil driver. In this research, a parallel resonance based coil driver and serial resonance based coil driver are proposed. From the experiments we see that the parallel coil driver shows better performance under a low impedance and multiple coils configuration. However, the serial coil driver is more efficient for high impedance transmit coils.

Predictors of outcomes after the trans-obturator tape procedure in females with equal severity for stress and urge mixed urinary incontinence

  • Young-Joo Kim
    • Journal of Medicine and Life Science
    • /
    • v.20 no.4
    • /
    • pp.166-171
    • /
    • 2023
  • Mixed urinary incontinence (UI) is common in women. This study aimed to assess the efficacy of anti-incontinence surgery in female patients with equally severe stress UI (SUI) and urge UI (UUI). All patients had equal severity of SUI and UUI. The postoperative cure rate was categorized into the cure group (CG) and failure group (FG). Postoperative satisfaction was categorized into the satisfaction group (SG) and the dissatisfaction group (DG). Statistical significance was set at P<0.05. Ninety patients (SG, 73.3%; DG, 26.7%; CG, 93.3%; FG, 6.7%) were included in the study. In the univariate analysis, body mass index (BMI), total bladder capacity, and overactive bladder symptom score (OABSS) were significantly different between the SG and DG groups. Peak urinary flow, Valsalva leak point pressure (VLPP), and OABSS were significantly different between the CG and FG groups. In the multivariate analysis, OABSS (P=0.001) and BMI (P=0.032) were independent predictors of postoperative satisfaction. VLPP (P=0.023) was the only independent factor associated with the postoperative cure rate. In equal severity of SUI and UUI, VLPP was found to be the only independent factor associated with postoperative cure rates. Higher VLPP values were associated with higher cure rates. BMI and OABSS were identified as independent predictors of postoperative satisfaction, with lower BMI and OABSS associated with higher postoperative satisfaction.