• Title/Summary/Keyword: Bis-EMA

Search Result 8, Processing Time 0.024 seconds

Mechanical properties of composite resins for dental restorative (치과 수복재용 복합레진의 기계적 물성에 대한 연구)

  • Ryu, Ho-Nam;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.35
    • /
    • pp.31-34
    • /
    • 2015
  • The purpose of the study was to investigate the mechanical properties (diametral tensile strength, flexural strength, compressive strength, Vickers hardness) of 4 kinds of composit resins; Bis-GMA based composit, Bis-EMA based composit, Bis-GMA/UDMA based composit, and Bis-EMA/UDMA based composit, The composit resin based Bis-GMA showed stronger mechanical properties than Bis-EMA. It was found that the addition of UDMA to both Bis-GMA based composit and Bis-EMA based composit highly improved mechanical properties. However, the mechanical properties of the composit resins prepared in this study were lower than those of the commercialized products in market(Charmfil flow(Denkist), Quadrant flow(CAVEX)), since the composit resins prepared in this study has much lower inorganic filler content of 43wt% comparing with 50~70wt% inorganic filler content of the commercialized products.

  • PDF

Physical properties of composite resins for dental restorative (치과 수복재용 복합레진의 물리적 특성에 대한 연구)

  • Kim, Ji Yeob;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.35
    • /
    • pp.35-39
    • /
    • 2015
  • One of the purposes of the study was to investigate and compare the physical properties(depth of light cure, degree of conversion, water absorption) of 4 kinds of composit resins prepared in this lab; Bis-GMA based, Bis-EMA based, Bis-GMA/UDMA based, and Bis-EMA/UDMA based composit. Another aim was to compare the physical properties of the composit resins with those of the commercialized products(Charmfil flow(Denkist), Quadrant flow(CAVEX)) in market. All of the composit resins and the commercialized products showed almost same values of the physical properties. It was found that all of the composit resins prepared in this lab satisfied the physical properties specified in ISO 4049.

  • PDF

CORRELATION BETWEEN BIS-GMA : TEGDMA RATIO AND DEGREE OF CONVERSION IN VARIOUS LAYERS OF COMPOSITE AFTER ADDITIONAL HEAT CURING (수종 복합레진 내의 bis-GMA와 TEGDMA의 구성비가 레진 인레이 법에 의한 부가적 열처리시 복합레진의 표면 및 내부의 중합률 변화에 미치는 영향)

  • Park, Seong-Ho;Chung, Chan-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.642-651
    • /
    • 1996
  • The purpose of this study was to evaluate the relationship between monomer compositions and the changes in the degree of conversion in the various layers of composites after additional heat curing. Four types of composites and 3 types of inlay ovens were used in this study. Composite was placed in a 4-mm thick teflon mold, and light cured from the top for 60 seconds. Ten samples were prepared for each composite ; 5 of these were additionally heat cured in an inlay oven as the manufacturer recommended. After light curing or light and heat curing, the samples were sectioned into four parts and assigned to groups A, B, C, or D according to their distance from the light source. These sections were then thinned to 50-$70{\mu}m$, and these wafers were analyzed with a Fourier Transform Infrared Spectrometer(FI-IR) to determine the degree of conversion. A standard baseline technique was used to calculate the degree of conversion. $^{13}C$ NMR spectra of bis-GMA, TEGDMA and bis-EMA, were acquired using a Varian Gemini spectrometer operated at 200 MHz. $CDCl_3$ solvent was used for qualitative analysis. The degree of conversion was affected by bis-GMA : TEGDMA ratio but it seemed to be also affected by other factors. When the composites were heat cured, significant increases in the degree of conversion were noted throughout the samples, but the amount of increase differed between materials. Thus, clinical performance of a heat-treated composite inlay may be different depending on materials.

  • PDF

Structural and Molar Mass Characterization of Commercial Aliphatic Hyperbranched Polyesters

  • Zager, Ema;Huskic, Miroslav;Zigon, Majda
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.114-115
    • /
    • 2006
  • We investigated the effects of annealing on the rearrangement of H-bonding structure and its influence on the thermal and rheological properties of $2^{nd}\;and\;4^{th}$ pseudo-generation aliphatic hyperbranched (HB) polyesters based on 2,2-bis(methylol)propionic acid. During annealing of amorphous HB polyesters, the structure becomes more ordered as a consequence of multiple H-bonds formation between linear sequences. Structure ordering is more pronounced for the lower pseudo-generation HB polyester with low molar mass, low degree of branching and incompletely reacted core hydroxyl groups which greatly increases the possibility for multiple H-bond interactions.

  • PDF

Optimal combination of 3-component photoinitiation system to increase the degree of conversion of resin monomers (레진 모노머의 중합전환률 증가를 위한 3종 중합개시 시스템의 적정 비율)

  • Kim, Chang-Gyu;Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.313-323
    • /
    • 2011
  • Objectives: This study investigated the optimal combination of 3-component photoinitiation system, consisting of CQ, p-octyloxy-phenyl-phenyl iodonium hexafluoroantimonate (OPPI), and 2-dimethylaminoethyl methacrylate (DMAEMA) to increase the degree of conversion of resin monomers, and analyze the effect of the ratio of the photoinitiator to the co-initiator. Materials and Methods: Each photoinitiators (CQ and OPP) and co-initiator (DMAEMA) were mixed in three levels with 0.2 wt.% (low concentration, L), 1.0 wt.% (medium concentration, M), and 2.0 wt.% (high concentration, H). A total of nine groups using the Taguchi method were tested according to the following proportion of components in the photoinitiator system: LLL, LMM, LHH, MLM, MMH, MHL, HLH, HML, HHM. Each monomer was polymerized using a quartz-tungsten-halogen curing unit (Demetron 400, USA) for 5, 20, 40, 60, 300 sec and the degree of conversion (DC) was determined at each exposure time using FTIR. Results: Significant differences were found for DC values in groups. MMH group and HHM group exhibited greater initial DC than the others. No significant difference was found with the ratio of the photoinitiators (CQ, OPPI) to the co-initiator (DMAEMA). The concentrations of CQ didn't affect the DC values, but those of OPPI did strongly. Conclusions: MMH and HHM groups seem to be best ones to get increased DC. MMH group is indicated for bright, translucent color and HHM group is good for dark, opaque colored-resin.

Effect of CQ-amine ratio on the degree of conversion in resin monomers with binary and ternary photoinitiation systems

  • Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.96-103
    • /
    • 2012
  • Objectives: This study evaluated the effect of camphorquinone (CQ)-amine ratio on the C=C double bond conversion of resins with binary and ternary photoinitiation systems. Materials and Methods: Two monomer mixtures (37.5 Bis-GMA/37.5 Bis- EMA/25 TEGDMA) with binary systems (CQ/DMAEMA in weight ratio, group A [0.5/1.0] and B [1.0/0.5]) and four mixtures with ternary system (CQ/OPPI/DMAEMA, group C [0.1/1.0/0.1], D [0.1/1.0/ 0.2], E [0.2/1.0/0.1] and F [0.2/1.0/0.2]) were tested: 1 : 2 or 2 : 1 CQ-amine ratio in binary system, while 1 : 1 ratio was added in ternary system. The monomer mixture was cured for 5, 20, 40, and 300 sec with a Demetron 400 curing unit (Demetron). After each exposure time, degree of conversion (DC) was estimated using Fourier transform infrared (FTIR) spectrophotometer (Nicolet 520, Nicolet Instrument Corp.). The results were analyzed by ANOVA followed by Scheffe test, with p = 0.05 as the level of significance. Results: DC (%) was expressed in the order of curing time (5, 20, 40, and 300 sec). Group A ($14.63{\pm}10.42$, $25.23{\pm}6.32$, $51.62{\pm}2.69$, $68.52{\pm}2.77$); Group B ($4.04{\pm}6.23$, $16.56{\pm}3.38$, $37.95{\pm}2.79$, $64.48{\pm}1.21$); Group C ($16.87{\pm}5.72$, $55.47{\pm}2.75$, $60.83{\pm}2.07$, $68.32{\pm}3.31$); Group D ($23.77{\pm}1.64$, $61.05{\pm}1.82$, $65.13{\pm}2.09$, $71.87{\pm}1.17$); Group E ($28.66{\pm}2.92$, $56.68{\pm}1.33$, $60.66{\pm}1.17$, $68.78{\pm}1.30$); Group F ($39.74{\pm}6.31$, $61.07{\pm}2.58$, $64.22{\pm}2.29$, $69.94{\pm}2.15$). Conclusion: All the monomers with ternary photoinitiation system showed higher DC than the ones with binary system, until 40 sec. Concerning about the effect of CQ-amine ratio on the DC, group A converted into polymer more than group B in binary system. However, there was no significant difference among groups with ternary system, except group C when cured for 5 sec only.

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

MICROLEAKAGE OF THE EXPERIMENTAL COMPOSITE RESIN WITH THREE COMPONENT PHOTOINITIATOR SYSTEMS (3종 광중합개시제를 함유한 실험용 복합레진의 미세누출도)

  • Kim, Ji-Hoon;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2009
  • This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 ${\mu}m$) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/$cm^2$. Teeth were thermocycled fivehundred times between $50^{\circ}C$and $550^{\circ}C$for 30s at each temperature. Electrical conductivity (${\mu}A$) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (${\mu}A$)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.