• Title/Summary/Keyword: Biomedical research

Search Result 6,235, Processing Time 0.042 seconds

Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators (교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사)

  • Lee, Mihyeon;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.467-477
    • /
    • 2014
  • The purpose of this study is to offer data base for establishment of dental training x-ray generator based safety usage through surveying real radiation safety management state of radiation worker's in plan of operations that have dental training x-ray generators and use it. For it, comprehensive references were surveyed referring reports of current state of regulation technique development and domestic radiation safety evaluation and nuclear related legislation regarding radiation safety management of dental training x-ray generators. On the basis of it, questionnaires were filled in about respondent's general characteristic radiation safety manager's status current state of radiation safety management and the level of knowledge & consciousness. For the study, the survey was conducted to 224 people of radiation safety managers and university graduates training assistants and full-time professors who can treat dental training x-ray generators in education center. through this survey 95 questionnaires were used as analysis materials except the insufficient and omitted responses. As a method of analysis, the frequency and percentage were figured out with the general characteristics and safety manager's status. Chi-square test for frequency and correlation per question analysis and Pearson correlation analysis for crosslevel correlation were done with current state of radiation safety management and knowledge & consciousness level. As a result, running dental training x-ray generators was dealt with by 20's to 40's who have high education level over post undergraduate degree and major in dental hygienic. In addition, female have higher consciousness level for radiation safety management than male. It shows significal linear relation statistically(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

Multi-Component Relaxation Study of Human Brain Using Relaxographic Analysis (Relaxographic 분석법을 이용한 뇌의 다중 자기이완특성에 관한 연구)

  • Yongmin Chang;Bong Soo Han;Bong Seok Kang;Kyungnyeo Jeon;Kyungsoo Bae;Yong-Sun Kim;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.120-128
    • /
    • 2002
  • Purpose : To demonstrate that the relaxographic method provides additional information such as the distribution of relaxation times and water content which are poentially applicable to clinical medicine. Materials and Methods : First, the computer simulation was performed with the generated relaxation data to verify the accuracy and reliabilility of the relaxographic method (CONTINI). Secondly, in or der to see how well the CONTIN quantifies and resolves the two different ${T_1}$ environments, we calculated the oil to water peak area ratios and identified peak positions of ${T_1}-distribution$ curve of the phantom solutions, which consist of four centrifugal tubes (10 ml) filled with the compounds of 0, 10, 20, 30% of corn oil and distilled water, using CONTIN. Finally, inversion recovery MR images for a volunteer are acquired for each TI ranged from 40 to 1160 msec with TR/TE=2200/20 msec. From the 3 different ROIs (GM, WM, CSF), CONTIN analysis was performed to obtain the ${T_1}$-distribution curves, which gave peak positions and peak area of each ROI location. Results : The simulation result shows that the errors of peak positions were less in the higher peak (centered ${T_1}=600$ msec) than in the lower peak (centered ${T_1}=150$ msec) for all SNR but the errors of peak areas were larger in the higher peak than in the lower peak. The CONTIN analysis of the measured relaxation data of phantoms revealed two peaks between 20 and 60 msec and between 500 and 700 msec. The analysis gives the peak area ratio as oil 10%: oil 20%: oil 30% = 1:1.3:1.9, which is different from the exact ratio, 1:2:3. For human brain, in ROI 3 (CSF), only one component of -distributions was observed whereas in ROI 1(GM) and in ROI 2 (WM) we observed two components of ${T_1}-distribution$. For the WM and CSF there was great agreement between the observed ${T_1}-relaxation$ times and the reported values. Conclusion : we demonstrated that the relaxographic method provided additional information such as the distribution of relaxation times and water content, which were not available in the routine relaxometry and ${T_1}/{T_2}$ mapping techniques. In addition, these additional information provided by relaxographic analysis may have clinical importance.

  • PDF

A Comparative Study on the Effects of Wearing Reverse Geometry Lenses by Degrees of Myopia (근시정도에 따른 역기하렌즈 착용효과에 관한 비교 연구)

  • Yoon, Min-Hwa;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.265-272
    • /
    • 2012
  • Purpose: To compare the results on myopia correction with reverse geometry lenses, effects of wearing reverse geometry lenses were evaluated for the children with low-level and high-level myopia. Methods: The research investigated the corrective effects of having worn reverse geometry lenses for one week, one month, three months and six months on a total of thirty-six persons (sixty-two eyes) between the ages of seven and fifteen, divided into three groups by the degree of their myopia; nineteen eyes(Group One) with myopia of -2.00 D and under, twenty-eight eyes(Group Two) with myopia between -2.25 D and -4 D, and fifteen eyes(Group Three) with myopia of -4.25 D and above; as shown by changes in uncorrected vision and the degree of refraction in the corneal topography, and tested for statistical similarity among the pursued results. Results: After wearing reverse geometry lenses, Group One showed an improvement in vision of 0.5, from 0.45 to 0.95, after one week, and improvements to 0.91 after one month and 1.02 after three months but, after six months, the group's vision regressed to 0.95. Group Two showed an improvement in vision of 0.43, from 0.34 to 0.77, after one week of wearing and to 0.91 after one month, to 0.97 after three months and this was statistically maintained through the remainder of six months. Group Three showed an improvement in vision of 0.55, from 0.15 to 0.7, after wearing for one week, to 0.87 after one month and to 0.91 after three months but saw a regression to 0.86 after six months. The average Sim K (simulated keratometry reading) value for Group One started from $42.84{\pm}1.17D$ and decreased to $41.48{\pm}0.98D$ after one week of wearing and continued declining through three months before increasing during the remainder of six months. Group Two began from $42.91{\pm}1.57D$ and recorded $41.78{\pm}1.58 D$ after one week, continuing the decline through three months before increasing during the remainder of six months. Group Three began at $42.64{\pm}1.64D$ and showed its Sim K value decrease to $40.77{\pm}1.20D$ after one week of wearing, increase after one month and decrease after three months and continue the decline through the remainder of six months. Conclusions: From the results of this study, wearing reverse geometry lenses had myopia-correcting effects after one week of wearing. Although there were variations in the time for such effect to take place but myopia-correcting effects were evident in all test groups.

The Validity and Reliability of 'Computerized Neurocognitive Function Test' in the Elementary School Child (학령기 정상아동에서 '전산화 신경인지기능검사'의 타당도 및 신뢰도 분석)

  • Lee, Jong-Bum;Kim, Jin-Sung;Seo, Wan-Seok;Shin, Hyoun-Jin;Bai, Dai-Seg;Lee, Hye-Lin
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.2
    • /
    • pp.97-117
    • /
    • 2003
  • Objective: This study is to examine the validity and reliability of Computerized Neurocognitive Function Test among normal children in elementary school. Methods: K-ABC, K-PIC, and Computerized Neurocognitive Function Test were performed to the 120 body of normal children(10 of each male and female) from June, 2002 to January, 2003. Those children had over the average of intelligence and passed the rule out criteria. To verify test-retest reliability for those 30 children who were randomly selected, Computerized Neurocognitive Function Test was carried out again 4 weeks later. Results: As a results of correlation analysis for validity test, four of continues performance tests matched with those on adults. In the memory tests, results presented the same as previous research with a difference between forward test and backward test in short-term memory. In higher cognitive function tests, tests were consist of those with different purpose respectively. After performing factor analysis on 43 variables out of 12 tests, 10 factors were raised and the total percent of variance was 75.5%. The reasons were such as: 'sustained attention, information processing speed, vigilance, verbal learning, allocation of attention and concept formation, flexibility, concept formation, visual learning, short-term memory, and selective attention' in order. In correlation with K-ABC to prepare explanatory criteria, selectively significant correlation(p<.0.5-001) was found in subscale of K-ABC. In the test-retest reliability test, the results reflecting practice effect were found and prominent especially in higher cognitive function tests. However, split-half reliability(r=0.548-0.7726, p<.05) and internal consistency(0.628-0.878, p<.05) of each examined group were significantly high. Conclusion: The performance of Computerized Neurocognitive Function Test in normal children represented differ developmental character than that in adult. And basal information for preparing the explanatory criteria could be acquired by searching for the relation with standardized intelligence test which contains neuropsycological background.

  • PDF

Tissue Engineered Cartilage Formation on Various PLGA Scaffolds (PLGA 종류와 담체의 형성 방법에 따른 인간의 조직공학적 연골형성)

  • 김유미;임종옥;정호윤;박태인;백운이
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.147-153
    • /
    • 2002
  • The purpose of this study was to evacuate the effect of different types of Poly(lactic-co-glycolic acid) (PLGA) scaffolds on the formation of human auricular and septal cartilages. All of the scaffolds were formed in a tubular shape for potential application for artificial trachea or esophagus with either 110,000 g/mol PLGA. 220,000 g/mol PLGA. or a combination of both. In order to maintain the tubular shape in vivo, two methods were used. One method was inserting polyethylene tube at the center of scaffolds made of 110,000 g/mol PLGA. The other method involved combination of the two different molecular weight PLGA's. The inner surface of tubular shaped scaffold made with 110,000 g/mol PLGA was coated with 220,000 9/mol PLGA to give more mechanical rigidity. Elastic cartilage was taken from the ear of a patient aged under 20 nears old and hyaline cartilage was taken from the nasal septum. The chondrocytes were then isolated. After second passage, the chondrocytes were seeded on the PLGA scaffolds followed by in vitro culture for one week. The cells-PLGA scaffold complex were implanted subcutaneously on the back of nude mice for 8 weeks. The tissue engineered cartilages were separated from nude mice and examined histologically after staining with the Hematoxylin Eosin. The morphology of the scaffolds were examined by scanning electron microscopy. The pores were well formed and uniformly distributed in the various PLGA scaffolds. After 8 weeks in vivo culture, cartilage was well formed with 110,000 g/mol PLGA. however lumen had collapsed. In contrast. a minimal amount of neocartilage was formed with 220,000 g/mol PLGA, while the architecture of scaffold and lumen were well preserved. Elastic cartilage formed more neocartilage than hyaline. Hyaline and elastic neocartilage were well formed on 110,000 g/mol PLGA with the polyethylene tube, exhibiting mature chondrocytes and preservation of the tubular shape. It was found that 110,000 g/mol PLGA was more appropriate for cartilage formation but higher molecular weight polymer was necessary to maintain the three dimensional shape of the scaffold.

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

Preparation of guidance documents item by item for one-step evaluation and approval for Medical Devices (의료기기 일괄허가 및 기술문서 심사를 위한 품목별 길라잡이 개발)

  • Kim, Yong-Woo;Shin, Chae-Min;Bang, Ji-Young;Yi, Jung-Yeon;Oh, Hyeon-Joo;Bae, Woo-Jin;Choi, Jin-Man;Lim, Kyung-Mi;Oh, Heon-Jin;Kim, Mi-Young;Hur, Chan-Hoi;Kim, Hyung-Bum;Choi, Min-Yong;Kwak, Ji-Young;Kim, Su-Yeon;Hwang, Sang-Yeon;Youn, Hae-Suk;Hong, Hye-Kyeong;Ahn, So-Young;Lee, Chang-Hyung;Jeong, Jin-Baek;Koo, Ja-Jung;Kang, Se-Gu;Jung, Jae-Hoon;Lim, Kyoung-Taek;Lim, Chang-Keun;Kim, Min-Su;Lee, Seong-Hyi;Lee, Jae-Keun;Park, Ki-Jung
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.280-284
    • /
    • 2010
  • Approvals of medical device increase every year as industry of medical device grows. Therefore KFDA keeps trying to improve approval systems. However, the firms of medical device are in trouble due to regulation amendment, a firm of small size, exchange of the person in charge. The staffs of KFDA increase their work load because applicants of approval of medical device aren't used to writing of document. Therefore the firm of medical device in business have a long term. KFDA develops eight guidance document item by item for one-step evaluation and approval for Medical Devices because applicants of approval of medical device write documents easily. KFDA reviewer can carry on quick reviewing in use of this eight guidances. This guidance are improved on satisfaction of applicants of approval of medical device.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Hypersensitive Large Intestine Syndrome in Hyungsang Medicine (과민성대장증후군의 형상의학적 고찰 -동의보감(東醫寶鑑)을 중심으로-)

  • Choi Byung-Tae;Choi Yung-Hyun;Han Jin-Soo;Lee Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1129-1136
    • /
    • 2005
  • The writer reports the conclusions gained from study about the cause of the hypersensitive large intestine syndrome with Dongeuibogam as the central figure through researching the disharmony among Body Essence, Vital Energy, Mentality, and Blood, mutual action of five viscera and six bowels, and external shapes. The hypersensitive large intestine syndrome is generally chronic and recurred in many cases, so it is more efficacious than symptomatic to treat according to find the contradictions of individual shapes. The shapes and cases suffering frequently the hypersensitive large intestine syndrome are Gi-kwa and Sin-kwa, having a long nose, having a bruised spot on Triple warmer, man with inclined mouth, Taeeum type, man with congested fluids, man with colic symptoms. The hypersensitive large intestine syndrome in Oriental medicine is recognized of diarrhea, constipation, abdominal pain, abdominal distention and fullness caused by seven emotions. In Dongeuibogam it can be found out the similarity in depressive symptoms due to disorder of Gi, stagnation of Gi, dysphasia due to disorder of Gi, diarrhea due to disorder of Gi, fullness of due to Gi, diarrhea due to phlegm-retention, retention of undigested food, immoderate drinking, hypo-function of the spleen, or deficiency, abdominal pain from colic symptom, and difficulty in defecation and urination, internal injury, diarrhea due to weakness and fatigue. If the Jung, Gi, Sin, and Hyul composed the human body is broken harmony, the function of large intestinal transmission would be fallen, so similar symptoms like the hypersensitive large intestine syndrome are gotten. Especially Gi-kwa suffers diarrhea, constipation abdominal pain, and abdominal distention and fullness due to depressive symptoms from disorder of Seven emotions or Seven Gi. And Sin-kwa suffers from the hypersensitive large intestine syndrome due to emotional restlessness having an influence on rhythmic movement of abdomen. Examining between five viscera and six bowels and the hypersensitive large intestine syndrome, Liver cannot disperse well having influence on mutual relation of Liver-Large intestine, Heart reduces the function of defecation and urination not to control the seven emotions, Lung having exterior and interior relation with intestine has an influence on primordial energy and let the main symptoms occur, Spleen circulating the body fluid let the main symptoms occur due to malfunction of circulation, Kidney locating in lower part of the body has deep connection with intestine, so let the disorder. Urinary bladder is connected with intestine in moisture metabolism, Stomach is connected in receive and transmission, Small intestine is connected in absorption and excretion, from small intestine pain disturbing the abdominal movement, Samcho managing the catharsis of lower heater if declined its function causes the hypersensitive large intestine syndrome. The colic symptoms of Front private parts which disorder in lower abdomen give rise to abdominal pains, difficulty in defecation and urination due to Cold are similar to the hypersensitive large intestine syndrome. The treatments of applying the shapes of colic syndrome advocated by Master Park can be efficacious cure in clinic. Researching after the clinical cases of Master Park advocating Hyungsang medicine, we came to know that plenty of prescriptions of internal injury are applied and take good effects.

Temporal Variations of Cerebrovascular Diseases in a University Hospital (일개 대학병원을 대상으로 한 뇌혈관질환의 시간적 변동양상)

  • Lee, Mi-Yon;Lee, Sang-Bock;Lee, Jun-Hang;Lee, Sam-Yul;Lee, Tae-Soo;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • Background: Cerebrovascular diseases are known to show different patterns of incidence among regions and races. Therefore, it is very important to determine the incidence pattern of a specific area in order to diagnose, treat and prevent cerebrovascular diseases. The objective of the present study is to analyze quantitatively the incidence ratios of hemorrhagic and ischemic cerebrovascular diseases by season, by gender and by age. Methods: The subjects of this study were 1603 patients hospitalized for hemorrhagic or ischemic cerebrovascular diseases at the Department of Neurosurgery or the Department of Neurology of a University Hospital. Statistical analysis of data used Excel 2003 of Microsoft, and t-test was conducted using ORIGIN 6.0 of MICROCAL. Results: In the subjects, the incidence ratios of hemorrhagic and ischemic cerebrovascular diseases for four years, the period of this research, were 38.55% and 61.45%, respectively. The mean and standard deviation of age when hemorrhagic cerebrovascular diseases occurred were 58.20 and 12.60, respectively, and the percentages of subjects in their 40s, 50s, 60s and 70s were all around 20%. On the contrary, the mean and standard deviation of age when ischemic cerebrovascular diseases occurred were 65.01 and 13.59, respectively. The average age of patients with ischemic cerebrovascular diseases was older than that of patients with hemorrhagic brain diseases, and the percentages of those in their 60s, 70s and 80s were 15.53%, 37.06% and 27.72%, respectively. The season when hemorrhagic cerebrovascular diseases appeared most frequently was winter, which was followed by summer, spring and autumn. The season when hemorrhagic cerebrovascular diseases appeared most frequently was spring, which was followed by summer, winter and autumn. Conclusions: In this study, the incidence rates of hemorrhagic and ischemic cerebrovascular diseases were 38.55% and 61.45%, showing the rising percentage of ischemic cerebrovascular diseases. For making adequate prevention and disease control plans, it is considered necessary to make a long-term epidemiological investigation of cerebrovascular diseases.

  • PDF