• Title/Summary/Keyword: Biomedical engineering

Search Result 7,053, Processing Time 0.037 seconds

The Correlation Between Sensory Integration Function and Scholar Achievement in the Lower Classes Children (저학령기 아동의 감각통합 기능과 학업성취도간의 상관관계)

  • Shin, Joong-Il;Choi, Yung-Gun;Jang, Woo-Heuk;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Objective : The purpose of this study is to provide reference to functional level of sensory integration of in the low-grads school age, based on the Clinical Observation of Motor and Postural Skills (COMPS) and to examine correlation between the function of sensory integration and academic achievement. Method : Two schools ("J" and "S") have been selected indiscriminately among 56 elementary schools located in Gimhae-si, GyeongNam and then one class from each school was voluntarily chosen among all second-grade classes of the schools. The total number of students in those two classes was 69 (34 boys and 35 girls). Subjects had no developmental problem and no history of referral regarding neurological conditions. Three skilled researchers administrated the COMPS together, and each researcher executed two sub-items of the COMPS. As result of the academic achievement, score data of midterm- and final-exam in the spring semester were collected. The scores of 'Korean language' and 'Math', common examination subjects in both schools, were utilized for data analysis in this study. Results : Statically, there was no significant correlation between the COMPS Weighted Scores and any academic achievements. In a dispersion graphic analysis, however, the total achievement showed significant negative-correlation with the area of 'Rapid Forearm Rotation' and significant positive-correlation with the area of 'Supine Flexion'. In terms of the Math achievement, there are significant negative-correlation with rapid forearm rotation and asymmetrical tonic neck reflex, and significant positive-correlation with the area of 'Supine Flexion'. Students with higher score of the Korean language showed a tendency to get higher Weighted Score and Minus Adjustment Score, and those with lower score of the Math showed a tendency to get higher COMPS scores in all area except the area of 'Supine Flexion'. There was a statically significant difference in the COMPS scores depend on the age among general characteristics. As student older, all COMPS scores, except those in the area of 'Slow Motion' and 'Supine Flexion, were higher. Conclusions : There is somehow reliable correlation between sensory integration function and academic achievement although no statistical significance found in this study. The information from this study may contribute to initiate developing a normative-reference to screen earlier and more alertly sensory integration dysfunctions for school-age children. Further study is recommended trying to find out more reliable matter regarding low grade- schooler's academic achievement.

  • PDF

A Study on the Cognition of Rehabilitation Practitioners Working at Community Rehabilitation Centers Toward Sensory Integration Therapy (장애인복지관에 근무하는 재활전문가들의 감각통합치료에 대한 인식조사)

  • Hwang, Ki-Cheol;Chang, Moon-Young;Ro, Hyo-Lyun
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.6 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • Objective : The purpose of this study is to investigate awareness of rehabilitation practitioners working at community wellness centers regarding the sensory integration (SI) therapy. Methods : 121 rehabilitation practitioners working at community wellness centers, located in Seoul Gyeonggi, Daegu Gyeongbuk and Busan Ulsan, participated in a questionnaire survey to examine their awareness of SI therapy. The questionnaire constructed based on four elements of the information about SI therapy; SI therapy's purpose, target population and technical process, and the qualification of SI therapist. Correlations between general characteristics and the four awareness elements of SI information were explored. The level of recognition on SI therapy were examined in various perspective such as 'have heard', 'means of the recognition', 'easiness of getting information', 'recognition of necessity of SI therapy', 'willing to participate in professional education course' and 'opinions for improving recognition'. Result : There is significant difference in awareness of the all four elements of SI informations depends on several general characteristics; practitioner's clinical field, location of the center, whether SI service has been provided or not at the center, whether the practitioner carry out SI therapy, and the practitioner's clinical experience in SI therapy. Specially, the recognition of occupational therapists is relatively high compared other rehabilitation practitioners. In terms of level of recognition, most rehabilitation practitioners(96.7%) are well-aware of necessity of sensory integration therapy. 79.4% of the practitioners manifest somewhat of difficulty in getting information related SI therapy. 93.4% of the practitioners are willing to participate in professional education course for SI therapy. Opinion for improving recognition with the most number of people(21) chosen is 'educational revitalization'. Conclusion : Many rehabilitation practitioners working at community wellness centers recognize the necessity of understand SI therapy, but there is uneasiness to get relative and valid information. There are difference awareness of the SI therapy Revitalization of education for SI therapy may provide an opportunity to improve level recognition of rehabilitation practitioners. It is suggested that organ related rehabilitation, there is a need for public relations.

  • PDF

Spectral Analysis of Hidden EEG Arousal Activity in Periodic Leg Movements in Sleep without Microarousal (미세각성이 없는 수면중 주기성 사지운동증 뇌파의 스펙트럼 분석)

  • Cyn, Jae-Gong;Seo, Wan-Seok;Oh, Jung-Su;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Objectives: Periodic leg movements in sleep (PLMS) might be subdivided based upon whether or not they are associated with visible EEG microarousals (MA). MA is considered to be responsible for nonrestorative sleep and daytime fatigue. The American Sleep Disorders Association's (ASDA) scoring rules for MA based on visual analysis of the EEG changes suggest that MA should last more than 3 seconds. However, it has been suggested that visual analysis may not detect some changes in EEG activity. This study is aimed at measuring changes in EEG spectra during PLMS without MA in order to better understand the arousing response of PLMS. Methods: Ten drug-free patients (three men and seven women) diagnosed with PLMS by polysomnography were studied. Spectral analysis of the EEG was performed in each patient on 30 episodes of PLMS without MA, chosen randomly across the night in stage 2 non-REM sleep. We applied stricter criteria for MA compared to ASDA, by defining it as a return to alpha and theta frequency lasting at least 1 second. Results: The mean PLMS index was $16.7{\pm}10.0$. The mean PLMS duration was $1.3{\pm}0.7$ seconds. Comparison of 4-second EEG activity both before and after the onset of PLMS without MA using independent t-test showed that the movements were associated with significant increase of relative activity in the delta band (p=0.000) and significant decrease of activity in the alpha (p=0.01) and sigma (p=0.000) bands. No significant decrease in the theta (p=0.05), beta (p=0.129), or gamma (p=0.062) bands was found. Conclusion: PLMS without MA was found to be associated with EEG change characterized by increase in the delta frequency band. This finding seems to be compatible with the hypothesis of an integrative hierarchy of arousal responses of Sforza's. Considering that the subjects had lower PLMS index and shorter PLMS duration than those of the previous study, it is suggested that an even less severe form of PLMS without MA could induce neurophysiologic change, which may potentially be of clinical significance.

  • PDF

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Traumatic Contusion of ICR Mouse Brain by FPI : $^{1}\textrm{H}$ MR Spectroscopic Study (유체타진손상기법에 의한 ICR 쥐의 뇌손상: 자기공명분광법)

  • Park, Chi-Bong;Kim, Hwi-Yool;Jeun, Sin-Soo;Han, Young-Min;Han, Duk-Young;Kang, Young-Woon;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.259-267
    • /
    • 2003
  • In vivo $^1$H magnetic resonance spectroscopy (MRS) at 4.7 T was applied to investigate the cerebral metabolite changes of mice brain before and after experimental brain trauma. In vivo $^1$H MR spectra were acquired from a voxel covering right parietal cortex in normal brain, used as control subjects. After experimental brain trauma using the fluid percussion injury (FPI) method, $^1$H MR spectra were acquired from the same lesion three days after trauma. Metabolite ratios of the injured lesion were compared to those of controls. After trauma, N-acetylaspartate (NAA)/creatine (Cr) ratio, as a neuronal marker was decreased significantly versus controls, indicating neuronal loss. The ratio of NAA/Cr in traumatic brain contusion was 0.90$\pm$0.11, while that in normal control subjects was 1.13$\pm$0.12 (P=0.001). Choline (Cho)/Cr ratio had a tendency to rise in experimental brain contusion (P=0.02). Cho/Cr ratio after trauma was 0.91$\pm$0.17 while that before traumas was 0.76$\pm$0.15. Cho/Cr ratio was increased and this might indicate a inflammatory activity. However, no significant difference of [(glutamate+glutamine) (Glx)]/Cr was established between experimental traumatic brain injury models and normal controls. Lactate (Lac)/Cr ratio was appeared as a sign of shifted posttraumatic energy metabolism and increased versus controls. These findings strongly suggest that in vivo $^1$H MRS may be a useful modality for clinical evaluation of traumatic contusion and could aid in better understanding the neuropathologic process of traumatic contusion induced by FPI. In the present study, in vivo $^1$H MRS was proved to be a useful non-invasive method for in vivo diagnosis and monitoring of posttraumatic metabolism in models of brain contusion.

  • PDF

Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy (근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가)

  • Park, Jeong-Eun;Kim, Kyo-Tae;Choi, Won-Hoon;Lee, Ho;Cho, Sam-Joo;Ahn, So-Hyun;Kim, Jin-Young;Song, Yong-Keun;Kim, Keum-bae;Huh, Hyun-Do;Park, Sung-Kwang
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2015
  • In radiation therapy fields, a brachytherapy is a treatment that kills lesion of cells by inserting a radioisotope that keeps emitting radiation into the body. We currently verify the consistency of radiation treatment plan and dose distribution through film/screen system (F/S system), provide therapy after checking dose. When we check dose distribution, F/S systems have radiation signal distortion because there is low resolution by penumbra depending on the condition of film developed. In this study, We fabricated a $HgI_2$ Semiconductor radiation sensor for base study in order that we verify the real dose distribution weather it's same as plans or not in brachytherapy. Also, we attempt to evaluate the feasibility of QA system by utilizing and evaluating the sensor to brachytherapy source. As shown in the result of detected signal with various source-to-detector distance (SDD), we quantitatively verified the real range of treatment which is also equivalent to treatment plans because only the low signal estimated as scatters was measured beyond the range of treatment. And the result of experiment that we access reproducibility on the same condition of ${\gamma}$-ray, we have made sure that the CV (coefficient of variation) is within 1.5 percent so we consider that the $HgI_2$ sensor is available at QA of brachytherapy based on the result.

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Regional Differences of Proteins Expressing in Adipose Depots Isolated from Cows, Steers and Bulls as Identified by a Proteomic Approach

  • Cho, Jin Hyoung;Jeong, Jin Young;Lee, Ra Ham;Park, Mi Na;Kim, Seok-Ho;Park, Seon-Min;Shin, Jae-Cheon;Jeon, Young-Joo;Shim, Jung-Hyun;Choi, Nag-Jin;Seo, Kang Seok;Cho, Young Sik;Kim, MinSeok S.;Ko, Sungho;Seo, Jae-Min;Lee, Seung-Youp;Chae, Jung-Il;Lee, Hyun-Jeong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.8
    • /
    • pp.1197-1206
    • /
    • 2016
  • Adipose tissue in the loin muscle area of beef cattle as a marbling factor is directly associated with beef quality. To elucidate whether properties of proteins involved in depot specific adipose tissue were sex-dependent, we analyzed protein expression of intramuscular adipose tissue (IMAT) and omental adipose tissue (OMAT) from Hanwoo cows, steers, and bulls of Korean native beef cattle by liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analysis, quantitative polymerase chain reaction (PCR) and western blot analysis. Two different adipose depots (i.e. intramuscular and omental) were collected from cows (n = 7), steers (n = 7), or bulls (n = 7). LC-MS/MS revealed a total of 55 and 35 proteins in IMAT and OMAT, respectively. Of the 55 proteins identified, 44, 40, and 42 proteins were confirmed to be differentially expressed in IMAT of cows, steers, and bulls, respectively. In OMAT of cows, steers, and bulls, 33, 33, and 22 were confirmed to be differentially expressed, respectively. Tropomyosin (TPM) 1, TPM 2, and TPM3 were subjected to verification by quantitative PCR and western blot analysis in IMAT and OMAT of Hanwoo cows, steers, and bulls as key factors closely associated with muscle development. Both mRNA levels and protein levels of TPM1, TPM2, and TPM3 in IMAT were lower in bulls compared to in cows or steers suggesting that they were positively correlated with marbling score and quality grade. Our results may aid the regulation of marbling development and improvement of meat quality grades in beef cattle.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Rectal Temperature Maintenance Using a Heat Exchanger of Cardioplegic System in Cardiopulmonary Bypass Model for Rats (쥐 심폐바이패스 모델에서 심정지액 주입용 열교환기를 이용한 직장체온 유지)

  • Choi Se-Hoon;Kim Hwa-Ryong;Paik In-Hyuck;Moon Hyun-Jong;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.505-510
    • /
    • 2006
  • Background: Small animal cardiopulmonary bypass (CPB) model would be a valuable tool for investigating path-ophysiological and therapeutic strategies on bypass. The main advantages of a small animal model include the reduced cost and time, and the fact that it does not require a full scale operating environment. However the rat CPB models have a number of technical limitations. Effective maintenance and control of core temperature by a heat exchanger is among them. The purpose of this study is to confirm the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. Material and Method: The miniature circuit consisted of a reservoir, heat exchanger, membrane oxygenator, roller pump, and static priming volume was 40 cc, Ten male Sprague-Dawley rats (mean weight 530 gram) were divided into two groups, and heat exchanger (HE) group was subjected to CPB with HE from a cardioplegia system, and control group was subjected to CPB with warm water circulating around the reservoir. Partial CPB was conducted at a flow rate of 40 mg/kg/min for 20 min after venous cannulation (via the internal juglar vein) and arterial cannulation (via the femoral artery). Rectal temperature were measured after anesthetic induction, a ter cannulation, 5, 10, 15, 20 min after CPB. Arterial blood gas with hematocrit was also analysed, 5 and 15 min after CPB. Result: Rectal temperature change differed between the two groups (p<0.01). The temperatures of HE group were well maintained during CPB, whereas control group was under progressive hypothermia, Rectal temperature 20 min after CPB was $36.16{\pm}0.32^{\circ}C$ in the HE group and $34.22{\pm}0.36^{\circ}C$ in the control group. Conclusion: We confirmed the effect of rectal temperature maintenance using a heat exchanger of cardioplegia system in cardiopulmonary bypass model for rats. This model would be a valuable tool for further use in hypothermic CPB experiment in rats.