• 제목/요약/키워드: Biomedical Parameter

검색결과 263건 처리시간 0.024초

Enhancement of Blood Compatibility of Albumin-Immobilized Polyurethane

  • Gyu Ha Ryu;Don
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권4호
    • /
    • pp.269-274
    • /
    • 1992
  • In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.raph.

  • PDF

생체내 포도당 동태의 등가회로모델 (Equivalent Circuit Model of Glucose Kinetics)

  • Yun, Jang-H.;Kim, Min-Chong
    • 대한의용생체공학회:의공학회지
    • /
    • 제2권1호
    • /
    • pp.31-38
    • /
    • 1981
  • The objective of the present study was to develop an equivalent circuit model of glucose kinetics including the hepatic glucose balance functions which were neglected in the previous compartmental models. Using this circuit model, the insulin resistivity parameter and hepatic glucose sensitivity parameter were estimated in optimal fitting of the model based data of glucose and insulin concentration to the reported clinical intravenous glucose tolerance test(IVGTT) data in normal and diabetic subjects. The addition of the hepatic function in the model has improved the overall performance of the simulation. Also, the computed tissue insulin resistivity and the hepatic glucose sensitivity are shown to be significant in distinguishin four clinical groups of normal and diabetic groups.

  • PDF

유동장내 길이가 다른 두 개의 리간드가 부착된 입자-세포간 상호작용 (Interaction between Particle with Dual Ligand and Cell under Flow)

  • 윤정현;이세영
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권2호
    • /
    • pp.71-80
    • /
    • 2022
  • The interaction between dual-ligand decorated particle-based delivery system and target cell under shear flow is predicted using probability model developed. We assumed the two kinds of ligand are decorated on the surface of the particle with 10% length difference. Fixed with other biophysical parameters, a study on the particle-cell interaction for the different non-specific interaction parameter is performed. To induce the firm adhesion, short ligand-receptor should be engaged. Also, it is shown that the rational design of ligand-receptor interaction, including receptor number, specific interaction parameter, kinds of ligand-receptor, etc., should be considered.

3D 내시경 영상시컨스의 MPEG-2 코딩 효율에 관한 연구 (A Study on the MPEG-2 Coding Performance of 3D Endoscopic Image Sequence)

  • 송철규;이영묵;이상민;김원기;이제호;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.84-87
    • /
    • 1997
  • In this study, for the coding of stereoscopic video sequence, two approaches are presented based on simulcast mathod and sidefield image format. The field sequential method for stereoscopic visualization have been specified. Also, camera parameter and shooting conditions for each test sequence are studied. Coding method based on sidefield format structure revealed better performance over simulcast in PSNR.

  • PDF

다변수 근신경 자극 시스템을 위한 전기자극 펄스 발생기의 설계 (Design of an Electrical Pulse Generator for the Multi-parameter Neuromuscular Stimulation System)

  • 고경록;김희찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.165-166
    • /
    • 1998
  • A multi-parameter neuro muscular electrical simulator (NMES) system was developed to be used to find the optimal parameter condition in obtaining maximum muscle power and minimal fatigue. Since the performance of NMES is mainly determined by the characteristic of its output-stage circuit, we implemented 3 different circuits and compared output characteristics of them. Three amplifier circuits are; 1) a resonant switching converter, 2) a linear amplifier with a transformer, and 3) a step-up DC/DC converter with a high-voltage linear amplifier. Experimental results showed that the step up DC/DC converter with a high-voltage linear amplifier has the best performance.

  • PDF

Open Circuit Fault Diagnosis Using Stator Resistance Variation for Permanent Magnet Synchronous Motor Drives

  • Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.985-990
    • /
    • 2013
  • This paper proposes a novel fault diagnosis scheme using parameter estimation of the stator resistance, especially in the case of the open-phase faults of PMSM drives. The stator resistance of PMSMs can be estimated by the recursive least square (RLS) algorithm in real time. Fault diagnosis is achieved by analyzing the estimated stator resistance of each phase according to the fault condition. The proposed fault diagnosis scheme is implemented without any extra devices. Moreover, the estimated parameter information can be used to improve the control performance. The feasibility of the proposed fault diagnosis scheme is verified by simulation and experimental results.

초음파를 이용한 골절치유과정의 정량적 평가기법 (Quantitative Evaluation Technique for Healing Fractured Bones Using Ultrasound)

  • 최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.359-366
    • /
    • 1995
  • The parameter, B/A, quantifies nonlinearity of the pressure-density relationship of propagation medium. This study investigated quantitative evaluation technique for healing fractured bones using this ultrasonic nonlinear parameter, B/A, obtained by the second harmonic amplitude method. A series of fundamental experiments were performed on cylinder phantoms made of aluminium, which demonstrated potential capability of nonlinear parameter B/A in the diagnosis of healing fractured bones using ultrasound.

  • PDF

광섬유를 이용한 각도 측정 연구 (A Study on Angle Measurements Using an Optical Fiber)

  • 김아희;김지선;오한별;김준식;고봉준;이은숙;정현철;최주현;백진영;전재훈
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.605-611
    • /
    • 2015
  • The measurement and analysis of angular change have been studied in many fields. This study developed an angle measurement technique with optical fiber and photodiode. The position and attached angle of photodiode were investigated to find the proper combination of parameter. The results showed that the increased measuring range was achieved when the position of detector was away from the center of rotation. Inverse mathematical model was used to obtain angular changes with an optical fiber. The applications of this study include in optical sensor, joint angle measurement, and sport science.

FUZZY Gain Tuning of PI Speed Controller Depending on Afterloads In Total Artificially Heart

  • 최정훈;최원우;최재순;엄경식;;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.156-160
    • /
    • 1997
  • In this paper, the control scheme is proposed that PI controller parameter used for TAH speed control is adapted by fuzzy logic method using only the motor current waveform. By scheduling PI parameters, minimization of the vibration and the energy consumption and overcoming AoP loads becomes possible. In in vitro tests experimental results show our approach is a good scheme that is adapted to changing afterloads well.

  • PDF

상완이두근의 등장성 운동시 근피로인자로서 표면근전도의 저주파수대역 선정에 관한 연구 (A Study on Low Frequency Band Selection as a Fatigue Parameter in Surface EMG during Isotonic Exercise of Biceps Brachii Muscle)

  • 이상식;이기영
    • Journal of Biosystems Engineering
    • /
    • 제36권4호
    • /
    • pp.285-289
    • /
    • 2011
  • Muscle fatigue is characterized as a progressive increase in discomfort arising from the active muscle at moderate load levels are maintained. The median frequency is the most commonly used as a parameter to describe muscle fatigue. However, the estimate of the median frequency is difficult to indicate muscle fatigue because of its high standard deviation and instability. This paper investigates the power changes of the appropriate low frequency band as a fatigue parameter in EMG during isotonic exercise. To select the appropriate band, linear regression lines are employed to calculate the slopes and the coefficient of determination. Three females and seven males volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until their exhaustion. The results of experiment shows that the power changes of the selected low frequency band (15~45 Hz) have linear slopes and high determinant coefficients. Therefore, this fatiguing parameter using the power changes of the low frequency band is valid to measure the state of muscular fatigue.