A Study on Angle Measurements Using an Optical Fiber
![]() |
Kim, A-Hee
(Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University)
Kim, Ji-Sun (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Oh, Han-Byeol (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Kim, Jun-Sik (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Goh, Bong-Jun (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Lee, Eun-Suk (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Jung, Hyon-Chel (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Choi, Ju-Hyeon (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Baek, Jin-Young (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) Jun, Jae-Hoon (Dept. of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, College of Biomedical and Health Science, Konkuk University) |
1 | S. H. Lee, “Development of a High-Resolution Encoder System Using Dual Optical Encoders,” Journal of the Korean Society for Precision Engineering, vol. 24, no. 9, pp. 76-85, 2007. |
2 | L. Tesio, M. Monzani, R. Gatti, and F. Franchignoni, “Flexible electro goniometers: kinesiological advantages with respect to potentiometric goniometers,” Clinical Biomechanics, vol. 10, no. 5, pp. 275-277, 1995. DOI ScienceOn |
3 | A. Shiratsu and H. J. C. G. Coury,” Reliability and accuracy of different sensors of a flexible electrogoniometer,” Clinical Biomechanics, vol. 18, no. 7, pp. 682-684, 2003. DOI ScienceOn |
4 | S. H. Nam, G. M. Baek, W. S. Jung, “Calibration System for Angular Vibration Using Precision Rotary Encoder,” Acoustical Society of Korea, vol. 33, no. 1, pp. 31-39, 2014. DOI ScienceOn |
5 | H. J. Kwak, J. M. Hwang, J. H. Kim, G. T. Park, “Development and Application of Three-axis Motion Rate Table for Efficient Calibration of Accelerometer and Gyroscope,” Journal of institute of control robotics and systems, vol. 18, no. 7, pp. 632-637, 2012. DOI ScienceOn |
6 | P. Roriz, L. Carvalho, O. Frazã, J. L. Santos, and J. A. Simõs, “From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: A review,” Journal of biomechanics, vol. 47, no. 6, pp. 1251-1261, 2014. DOI |
7 | S. G. Kim, S. H. Shin, D. Jeon, S. H. Hong, H. I. Sim, K. W. Jang, W. J. Yoo, B. Lee, “Fiber-optic Goniometer to Measure Knee Joint Angle for the Diagnosis of Gait Disturbance,” The Transactions of KIEE, vol, 62, no. 7, pp. 1009-1013, 2013. |
8 | G. I. Jung, J. S. Kim, D. H. Hur, H. D. Yu, S. H. Lim, J. H. Choi, J. H. Lee, G. M. Eom, and J. H. Jun, “Angular Displacement Measurement Using Optical Sensor,” The Transaction of KIEE, vol. 60, no. 10, pp. 1959-1965, 2011. |
9 | Al-Abdulwahab SS, Al-Dosry RD, “Hallux valgus and preferred shoe types among young healthy Saudi Arabian females,” Ann Saudi Med, vol. 20 no. 3-4, pp. 319-321, 2000. DOI |
10 | D. B. Chaffin, G. Andersson, and B. J. Martin, “Occupational Biomechanics,” 4th edition, New York:Wiley & Sons, 2006. |
![]() |